Adaptive Droop Control Applied to Voltage-Source Inverters Operating in Grid-Connected and Islanded Modes
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
This paper proposes a novel control for voltage-source inverters with the capability to flexibly operate in grid-connected and islanded modes. The control scheme is based on the droop method, which uses some estimated grid parameters such as the voltage and frequency and the magnitude and angle of the grid impedance. Hence, the inverter is able to inject independently active and reactive power to the grid. The controller provides a proper dynamics decoupled from the grid-impedance magnitude and phase. The system is also able to control active and reactive power flows independently for a large range of impedance grid values. Simulation and experimental results are provided in order to show the feasibility of the control proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Guerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Self-citationYuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993175 · Cited by 896
Control Strategy for Flexible Microgrid Based on Parallel Line-Interactive UPS Systems
Guerrero, J. M., Vasquez, J. C., Matas, J., Castilla, M., & de Vicuna, L. G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009274 · Cited by 788
Self-citationDesign, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723
Yuan, X., Allmeling, J., Merk, W., & Stemmler, H. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883122 · Cited by 663
Wireless-Control Strategy for Parallel Operation of Distributed-Generation Inverters
Guerrero, J. M., Matas, J., Garcia De Vicunagarcia De Vicuna, L., Castilla, M., & Miret, J. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882015 · Cited by 662
Self-citationHigh-Performance Stand-Alone Photovoltaic Generation System
Wai, R.-J., Wang, W.-H., & Lin, C.-Y. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.896049 · Cited by 453
Distributed Intelligent Energy Management System for a Single-Phase High-Frequency AC Microgrid
Chakraborty, S., Weiss, M. D., & Simoes, M. G. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888766 · Cited by 413
High-Quality Power Generation Through Distributed Control of a Power Park Microgrid
Prodanovic, M., & Green, T. C. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882019 · Cited by 341
Cited by
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Self-citationControl of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Self-citationSynchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Hierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
Lu, X., Guerrero, J. M., Sun, K., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2266419 · Cited by 1,049
Self-citationLow-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution
Kakigano, H., Miura, Y., & Ise, T. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2077682 · Cited by 995
Review of Power Sharing Control Strategies for Islanding Operation of AC Microgrids
Han, H., Hou, X., Yang, J., Wu, J., Su, M., & Guerrero, J. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2434849 · Cited by 988
Self-citationKanchev, H., Lu, D., Colas, F., Lazarov, V., & Francois, B. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2119451 · Cited by 985
Review of Active and Reactive Power Sharing Strategies in Hierarchical Controlled Microgrids
Han, Y., Li, H., Shen, P., Coelho, E. A. A., & Guerrero, J. M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2569597 · Cited by 808
Self-citationMultiple Distributed Generator Placement in Primary Distribution Networks for Loss Reduction
Hung, D. Q., & Mithulananthan, N. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112316 · Cited by 794
Dong, D., Wen, B., Boroyevich, D., Mattavelli, P., & Xue, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334665 · Cited by 709
Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter
Dannehl, J., Liserre, M., & Fuchs, F. W. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2081952 · Cited by 648
Alajmi, B. N., Ahmed, K. H., Finney, S. J., & Williams, B. W. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2090903 · Cited by 635
Control for Grid-Connected and Intentional Islanding Operations of Distributed Power Generation
Balaguer, I. J., Lei, Q., Yang, S., Supatti, U., & Peng, F. Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049709 · Cited by 622
A Review on Microgrids’ Challenges & Perspectives
Saeed, M. H., Fangzong, W., Kalwar, B. A., & Iqbal, S. (2021) · IEEE Access · doi:10.1109/access.2021.3135083 · Cited by 539
Control Techniques in AC, DC, and Hybrid AC–DC Microgrid: A Review
Sahoo, S. K., Sinha, A. K., & Kishore, N. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2786588 · Cited by 534
A review of droop control techniques for microgrid
Tayab, U. B., Roslan, M. A. B., Hwai, L. J., & Kashif, M. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.028 · Cited by 512
Distributed Adaptive Droop Control for DC Distribution Systems
Nasirian, V., Davoudi, A., Lewis, F. L., & Guerrero, J. M. (2014) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2350458 · Cited by 477
Self-citationHierarchical Control of Intelligent Microgrids
Vasquez, J., Guerrero, J., Miret, J., Castilla, M., & Garcia de Vicuna, L. (2010) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2010.938720 · Cited by 471
Self-citationD'Arco, S., & Suul, J. A. (2013) · 2013 IEEE Grenoble Conference · doi:10.1109/ptc.2013.6652456 · Cited by 443
Breaking the Hierarchy: Distributed Control and Economic Optimality in Microgrids
Dorfler, F., Simpson-Porco, J. W., & Bullo, F. (2016) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2015.2459391 · Cited by 440
Dynamic Stability of a Microgrid With an Active Load
Bottrell, N., Prodanovic, M., & Green, T. C. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2241455 · Cited by 416
A Maximum Power Point Tracking Technique for Partially Shaded Photovoltaic Systems in Microgrids
Alajmi, B. N., Ahmed, K. H., Finney, S. J., & Williams, B. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2168796 · Cited by 404
A survey on control of electric power distributed generation systems for microgrid applications
Bouzid, A. M., Guerrero, J. M., Cheriti, A., Bouhamida, M., Sicard, P., & Benghanem, M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.01.016 · Cited by 401
Self-citationMicrogrid stability: Classification and a review
Shuai, Z., Sun, Y., Shen, Z. J., Tian, W., Tu, C., Li, Y., & Yin, X. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.201 · Cited by 368
Improvement of Frequency Regulation in VSG-Based AC Microgrid Via Adaptive Virtual Inertia
Hou, X., Sun, Y., Zhang, X., Lu, J., Wang, P., & Guerrero, J. M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2923734 · Cited by 367
Self-citationCritical Review on PV MPPT Techniques: Classical, Intelligent and Optimisation
Bollipo, R. B., Mikkili, S., & Bonthagorla, P. K. (2020) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2019.1163 · Cited by 343
Zhou, T., & Francois, B. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046580 · Cited by 339
General aspects, hierarchical controls and droop methods in microgrids: A review
Planas, E., Gil-de-Muro, A., Andreu, J., Kortabarria, I., & Martínez de Alegría, I. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.09.032 · Cited by 318
A Control Strategy for Islanded Microgrids With DC-Link Voltage Control
Vandoorn, T. L., Meersman, B., Degroote, L., Renders, B., & Vandevelde, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2095044 · Cited by 296
Micallef, A., Apap, M., Spiteri-Staines, C., Guerrero, J. M., & Vasquez, J. C. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2291912 · Cited by 281
Self-citationA brief review on microgrids: Operation, applications, modeling, and control
Shahgholian, G. (2021) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12885 · Cited by 280
Distributed Control for Autonomous Operation of a Three-Port AC/DC/DS Hybrid Microgrid
Wang, P., Jin, C., Zhu, D., Tang, Y., Loh, P. C., & Choo, F. H. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2347913 · Cited by 263
Wind Turbine Power Coefficient Analysis of a New Maximum Power Point Tracking Technique
Xia, Y., Ahmed, K. H., & Williams, B. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2206332 · Cited by 256
Ahn, S.-J., Park, J.-W., Chung, I.-Y., Moon, S.-I., Kang, S.-H., & Nam, S.-R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2047736 · Cited by 252
D'Arco, S., Suul, J. A., & Fosso, O. B. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2354732 · Cited by 233
Overview of AC Microgrid Controls with Inverter-Interfaced Generations
Hossain, M., Pota, H., Issa, W., & Hossain, M. (2017) · Energies · doi:10.3390/en10091300 · Cited by 205
“To improve power sharing performance and line impedance mismatches, extra loops, such as reactive current loop and on-line reactive power offset estimator, are incorporated in [102,121].”
Catalán, P., Wang, Y., Arza, J., & Chen, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3234221 · Cited by 197
“including droop-based grid-forming control [270], power synchronization loop [271], virtual synchronous machine [243], and direct power control (DPC) [272].”
BackgroundTah, A., & Das, D. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2535264 · Cited by 191
Distribution System Harmonic Compensation Methods: An Overview of DG-Interfacing Inverters
Li, Y. W., & He, J. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2295421 · Cited by 184
“Also, the VCM in microgrid operation enables the use of droop control for load demand sharing without communications among the DG systems [14]–[17], [34].”
MethodVoltage and Frequency Regulation of Microgrid With Battery Energy Storage Systems
Zhao, H., Hong, M., Lin, W., & Loparo, K. A. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2741668 · Cited by 166
“To overcome the difficulty, the conventional droop method has been modified with virtual frame transformation [8], virtual output impedance [9] and virtual droop curve [10] that consider system network model and operational parameters.”
MethodZamani, M. A., Yazdani, A., & Sidhu, T. S. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2205713 · Cited by 161
Mohammed, N., Ravanji, M. H., Zhou, W., & Bahrani, B. (2023) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2022.3223976 · Cited by 129
He, L., & Yu, S. (2024) · IEEE Open Access Journal of Power and Energy · doi:10.1109/oajpe.2024.3360854 · Cited by 15
“Note that the P-f droop scheme is used instead of the P-ϕ droop scheme, as the f reference can be easily fixed at nominal values, while the initial phase angle of the PCC voltage cannot be known by the inverter [41].”
BackgroundMethod
Metadata
- Authors
- Vasquez, J. C., Guerrero, J. M., Luna, A., Rodriguez, P., & Teodorescu, R.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-10
- Volume
- 56
- Issue
- 10
- Pages
- 4088-4096
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2162535598
- Cited by
- 629
- References
- 16
- FWCI
- 40.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.