CoChat

Impact of Patient–General Practitioner Short-Messages-Based Interaction on the Control of Hypertension in a Follow-up Service for Low-to-Medium Risk Hypertensive Patients: A Randomized Controlled Trial

Carrasco, M.P., Salvador, C.H., Sagredo, P.G., Marquez-Montes, J., de Mingo, M.A.G., Fragua, J.A., Rodriguez, M.C., Garcia-Olmos, L.M., Garcia-Lopez, F., Carrero, A.M., Monteagudo, J.L. · 2008 · IEEE Transactions on Information Technology in Biomedicine
Cited by 72

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

The evaluation in real-life settings of services for the follow-up and control of hypertensive patients is a complex intervention, which still needs analysis of the roles, tasks, and resources involved in the basic items: patient, healthcare professional, and the interaction between the two. To evaluate the impact of patient-general practitioner (GP) short-messages-based interaction, isolated from other items, on the degree of hypertension control in the follow-up of medium-to-low-risk patients in primary care, a randomized controlled trial has been performed: 38 GPs enrolled 285 hypertensive patients who recorded the results of self-blood-pressure (BP) monitoring, heart rate, and body weight, and completed an optional questionnaire in an identical manner over a six-month period. The telemedicine group (TmG) sent the data to a telemedicine-based system that enabled patient-GP interaction; the control group (CG) recorded the data on paper and could only deliver it to their GP personally in the routine visits. In the TmG, the results were better, but not significantly so, for: 1) degree of hypertension control, in terms of the percentage of uncontrolled hypertensives at the final visit (TmG versus CG: 31.7% versus 35.6%; p = 0.47); 2) reduction in hypertension during follow-up, comparing measurements (performed by a professional) at the initial and final visits of systolic BP (15.5 versus 11.9; p = 0.13) and diastolic BP (9.6 versus 4.4; p = 0.40); and 3) adherence to the protocol within compliance levels of interest in a real-life follow-up service: >>50% (84.8% versus 73.3%) and >>25% (92.4.8% versus 75.4%) ( p = 0.053). Other factors such as average values of self-measured systolic BP, diastolic BP and heart rate, acceptability of the protocol, and median number of consultations and hospital admissions were similar in both groups. Outcomes show that, taken alone, the patient-GP short-messages-based interaction has very little impact on the degree of hypertension control in patients with this profile. In complex interventions, to discriminate the impact of each of its components in isolation will enable us to design an efficient follow-up service, little demanding in terms of healthcare professional dedication, and optimized in other basic aspects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/titb.2008.926429

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Research works printed but not linked: 33

  1. 10.1097/01.mbp.0000217996.19839.70 · DOI · Paper page
  2. nakamoto, 2004, blood pressure monitoring by cellular telephone in patients on continuous ambulatory peritoneal dialysis, Adv Perit Dial, 20, 105
  3. 10.1258/135763306777488753 · DOI
  4. 10.1097/00126097-200202000-00014 · doi:10.1097/00126097-200202000-00014
  5. 10.1258/135763302320939239 · DOI · Paper page
  6. 10.1089/tmj.2006.12.363 · DOI · Paper page
  7. 10.1016/j.ijmedinf.2006.05.041 · DOI
  8. 10.1097/00126097-200202000-00016 · DOI · Paper page
  9. 10.1097/01.hjh.0000194117.96979.13 · DOI · Paper page
  10. pascual, 2004, technical and functional description of the airmed-cardio-platform, presented at the 10th Med Conf Med Biol Eng MEDICON Health Telematics, 6
  11. 10.1007/s11906-006-0079-7 · DOI
  12. 10.1136/bmj.38121.684410.AE · DOI · Paper page
  13. 10.1016/j.amjhyper.2005.05.017 · DOI · Paper page
  14. 10.1016/S0895-7061(98)00241-6 · DOI · Paper page
  15. 10.1001/archinte.159.22.2689 · DOI · Paper page
  16. myers, 2004, current status of ambulatory blood pressure monitoring, Can J Cardiol, 20, 1424
  17. 10.1136/bmj.38558.393669.E0 · DOI · Paper page
  18. 10.1258/135763306777889046 · DOI · Paper page
  19. 10.1186/1471-2458-6-257 · DOI
  20. 10.1109/TITB.2004.840067 · DOI · Paper page
  21. 10.1097/00004872-200306000-00001 · DOI · Paper page
  22. 10.1038/sj.jhh.1001903 · DOI · Paper page
  23. 10.1258/1357633011936147 · DOI · Paper page
  24. 10.1038/sj.jhh.1001584 · DOI
  25. 10.1097/00004872-200311000-00002 · DOI · Paper page
  26. 10.2165/00044011-200626080-00002 · DOI
  27. 10.1111/j.1524-6175.2006.04872.x · DOI · Paper page
  28. 10.7326/0003-4819-134-11-200106050-00008 · DOI · Paper page
  29. 10.1016/0895-7061(95)00353-3 · DOI · Paper page
  30. 10.1109/TITB.2008.910750 · DOI · Paper page
  31. 10.1097/01.mbp.0000209073.30708.e1 · DOI · Paper page
  32. 10.1258/1357633054461705 · DOI · Paper page
  33. 10.1007/s11906-996-0020-0 · DOI

Cited by

Metadata

Authors
Carrasco, M. P., Salvador, C. H., Sagredo, P. G., Marquez-Montes, J., de Mingo, M. A. G., Fragua, J. A., Rodriguez, M. C., Garcia-Olmos, L. M., Garcia-Lopez, F., Carrero, A. M., & Monteagudo, J. L.
Venue
IEEE Transactions on Information Technology in Biomedicine
Published
2008-11
Volume
12
Issue
6
Pages
780-791
ISSN
1089-7771 (ISSN-L)
OpenAlex
W2113216509
Cited by
72
References
9
FWCI
3.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.