The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
Open accessAbstract
In the presence of metal implants, metal artifacts are introduced to x-ray computed tomography CT images. Although a large number of metal artifact reduction (MAR) methods have been proposed in the past decades, MAR is still one of the major problems in clinical x-ray CT. In this paper, we develop a convolutional neural network (CNN)-based open MAR framework, which fuses the information from the original and corrected images to suppress artifacts. The proposed approach consists of two phases. In the CNN training phase, we build a database consisting of metal-free, metal-inserted and pre-corrected CT images, and image patches are extracted and used for CNN training. In the MAR phase, the uncorrected and pre-corrected images are used as the input of the trained CNN to generate a CNN image with reduced artifacts. To further reduce the remaining artifacts, water equivalent tissues in a CNN image are set to a uniform value to yield a CNN prior, whose forward projections are used to replace the metal-affected projections, followed by the FBP reconstruction. The effectiveness of the proposed method is validated on both simulated and real data. Experimental results demonstrate the superior MAR capability of the proposed method to its competitors in terms of artifact suppression and preservation of anatomical structures in the vicinity of metal implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892
Deep Convolutional Neural Network for Inverse Problems in Imaging
Jin, K. H., McCann, M. T., Froustey, E., & Unser, M. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2713099 · Cited by 2,529
MatConvNet: Convolutional Neural Networks for MATLAB
Vedaldi, A., & Lenc, K. (2015) · Proceedings of the 23rd ACM international conference on Multimedia · doi:10.1145/2733373.2807412 · Cited by 2,444
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
Chen, H., Zhang, Y., Kalra, M. K., Lin, F., Chen, Y., Liao, P., Zhou, J., & Wang, G. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2715284 · Cited by 1,866
Self-citationGenerative Adversarial Networks for Noise Reduction in Low-Dose CT
Wolterink, J. M., Leiner, T., Viergever, M. A., & Isgum, I. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2708987 · Cited by 1,037
aLow-dose CT via convolutional neural network
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000679 · Cited by 755
Self-citationReduction of CT artifacts caused by metallic implants.
Kalender, W. A., Hebel, R., & Ebersberger, J. (1987) · Radiology · doi:10.1148/radiology.164.2.3602406 · Cited by 751
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
Low-Dose X-ray CT Reconstruction via Dictionary Learning
Xu, Q., Yu, H., Mou, X., Zhang, L., Hsieh, J., & Wang, G. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2195669 · Cited by 690
Self-citationMatConvNet - Convolutional Neural Networks for MATLAB
Vedaldi, A., & Lenc, K. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1412.4564 · Cited by 578
Wang, G. (2016) · IEEE Access · doi:10.1109/access.2016.2624938 · Cited by 455
LEARN: Learned Experts’ Assessment-Based Reconstruction Network for Sparse-Data CT
Chen, H., Zhang, Y., Chen, Y., Zhang, J., Zhang, W., Sun, H., Lv, Y., Liao, P., Zhou, J., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2805692 · Cited by 433
Self-citationIterative deblurring for CT metal artifact reduction
Wang, G., Snyder, D. L., O'Sullivan, J. A., & Vannier, M. W. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538943 · Cited by 409
Kachelrieß, M., Watzke, O., & Kalender, W. A. (2001) · Medical Physics · doi:10.1118/1.1358303 · Cited by 311
Metal streak artifacts in X-ray computed tomography: a simulation study
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775600 · Cited by 311
Metal Artifact Reduction in CT: Where Are We After Four Decades?
Gjesteby, L., De Man, B., Jin, Y., Paganetti, H., Verburg, J., Giantsoudi, D., & Wang, G. (2016) · IEEE Access · doi:10.1109/access.2016.2608621 · Cited by 290
An iterative approach to the beam hardening correction in cone beam CT
Hsieh, J., Molthen, R. C., Dawson, C. A., & Johnson, R. H. (2000) · Medical Physics · doi:10.1118/1.598853 · Cited by 280
Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
Bal, M., & Spies, L. (2006) · Medical Physics · doi:10.1118/1.2218062 · Cited by 234
Lemmens, C., Faul, D., & Nuyts, J. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.929103 · Cited by 194
Empirical beam hardening correction (EBHC) for CT
Kyriakou, Y., Meyer, E., Prell, D., & Kachelrieß, M. (2010) · Medical Physics · doi:10.1118/1.3477088 · Cited by 171
Metal artifact reduction in x‐ray computed tomography (CT) by constrained optimization
Zhang, X., Wang, J., & Xing, L. (2011) · Medical Physics · doi:10.1118/1.3533711 · Cited by 165
CT sinogram‐consistency learning for metal‐induced beam hardening correction
Park, H. S., Lee, S. M., Kim, H. P., Seo, J. K., & Chung, Y. E. (2018) · Medical Physics · doi:10.1002/mp.13199 · Cited by 141
Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction
Wang, G., Vannier, M. W., & Cheng, P. (1999) · Microscopy and Microanalysis · doi:10.1017/s1431927699000057 · Cited by 140
Prell, D., Kyriakou, Y., Beister, M., & Kalender, W. A. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/21/009 · Cited by 130
A Segmentation-Based Method for Metal Artifact Reduction
Yu, H., Zeng, K., Bharkhada, D., et al. (2007) · Academic Radiology · doi:10.1016/j.acra.2006.12.015 · Cited by 90
Self-citationDeep learning methods to guide CT image reconstruction and reduce metal artifacts
Gjesteby, L., Yang, Q., Xi, Y., Zhou, Y., Zhang, J., & Wang, G. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2254091 · Cited by 87
Deep learning methods for CT image-domain metal artifact reduction
Gjesteby, L., Yang, Q., Xi, Y., Claus, B. E. H., Jin, Y., Man, B. D., Wang, G., & Shan, H. (2017) · Developments in X-Ray Tomography · doi:10.1117/12.2274427 · Cited by 83
A hybrid metal artifact reduction algorithm for x‐ray CT
Zhang, Y., Yan, H., Jia, X., Yang, J. Q., Jiang, S. B., & Mou, X. (2013) · Medical Physics · doi:10.1118/1.4794474 · Cited by 82
Self-citationLow-dose CT restoration via stacked sparse denoising autoencoders
Liu, Y., & Zhang, Y. (2018) · Neurocomputing · doi:10.1016/j.neucom.2018.01.015 · Cited by 82
Self-citationAn experimental survey of metal artefact reduction in computed tomography
Mouton, A., Megherbi, N., Slambrouck, K. V., Nuyts, J. L., & Breckon, T. P. (2013) · Journal of X-Ray Science and Technology · doi:10.3233/xst-130372 · Cited by 76
Efficient CT Metal Artifact Reduction Based on Fractional‐Order Curvature Diffusion
Zhang, Y., Pu, Y., Hu, J., Liu, Y., Chen, Q., & Zhou, J. (2011) · Computational and Mathematical Methods in Medicine · doi:10.1155/2011/173748 · Cited by 36
Self-citationStacked competitive networks for noise reduction in low-dose CT
Du, W., Chen, H., Wu, Z., Sun, H., Liao, P., & Zhang, Y. (2017) · PLoS ONE · doi:10.1371/journal.pone.0190069 · Cited by 25
Self-citationBeam hardening correction for fan-beam CT imaging with multiple materials
Zhang, Y., Mou, X., & Tang, S. (2010) · doi:10.1109/nssmic.2010.5874473 · Cited by 19
Self-citationHegazy, M. A. A., Cho, M. H., & Lee, S. Y. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0240-8 · Cited by 18
Machine-learning-based nonlinear decomposition of CT images for metal artifact reductionPreprint
Park, H. S., Lee, S. M., Kim, H. P., et al. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1708.00244 · Cited by 15
Metal artifact reduction based on the combined prior imagePreprint
Zhang, Y., & Mou, X. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1408.5198 · Cited by 11
Self-citation
Cited by
Solving inverse problems using data-driven models
Arridge, S., Maass, P., Öktem, O., & Schönlieb, C.-B. (2019) · Acta Numerica · doi:10.1017/s0962492919000059 · Cited by 686
Willemink, M. J., & Noël, P. B. (2019) · European Radiology · doi:10.1007/s00330-018-5810-7 · Cited by 603
Deep learning for tomographic image reconstruction
Wang, G., Ye, J. C., & De Man, B. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-00273-z · Cited by 531
A gentle introduction to deep learning in medical image processing
Maier, A., Syben, C., Lasser, T., & Riess, C. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.12.003 · Cited by 515
Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects
Koetzier, L. R., Mastrodicasa, D., Szczykutowicz, T. P., van der Werf, N. R., Wang, A. S., Sandfort, V., van der Molen, A. J., Fleischmann, D., & Willemink, M. J. (2023) · Radiology · doi:10.1148/radiol.221257 · Cited by 427
Metadata
- Authors
- Zhang, Y., & Yu, H.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2018-06
- Volume
- 37
- Issue
- 6
- Pages
- 1370-1381
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2753044865
- Cited by
- 493
- References
- 37
- FWCI
- 16.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.