A Method for Attenuation Correction in Radionuclide Computed Tomography
The DOI matches its Crossref record.
Abstract
The development of algorithms for Radionuclide Computed Tomography (RCT) is complicated by the presence of attenuation of gamma-rays inside the body. Some of the existing RCT reconstruction algorithms apply approximation formulas to the projection data for attenuation correction, while others take attenuation into account through some iterative procedures. The drawbacks of these algorithms are that the approximation formulas commonly used are generally inadequate and the iterative procedures are usually very time-consuming. The method for attenuation correction in RCT, which we propose, applied a simple, effective two-step procedure to the uncorrected image. In this procedure the filtered back-projection algorithm is used for its fast speed. A simple mathematical basis and description of the procedure together with some illustrative computer results are given in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
A practical method for position-dependent Compton-scatter correction in single photon emission CT
Ogawa, K., Harata, Y., Ichihara, T., Kubo, A., & Hashimoto, S. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97591 · Cited by 616
Fessler, J. A., & Rogers, W. L. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.535846 · Cited by 518
Malison, R. T., Price, L. H., Berman, R., van Dyck, C. H., Pelton, G. H., Carpenter, L., Sanacora, G., Owens, M. J., Nemeroff, C. B., Rajeevan, N., et al. (1998) · Biological Psychiatry · doi:10.1016/s0006-3223(98)00272-8 · Cited by 496
Seibyl, J. P., Marchek, K. L., Quinlan, D., Sheff, K., Zoghbi, S., Zea‐Ponce, Y., Baldwin, R. M., Fussell, B., Smith, E. O., Charney, D. S., et al. (1995) · Annals of Neurology · doi:10.1002/ana.410380407 · Cited by 467
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
European Journal of Nuclear Medicine and Molecular Imaging
(2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/259.1619-7089 · Cited by 430
Iterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Mountz, J. M., Bradley, L. A., Modell, J. G., Alexander, R. W., Triana‐Alexander, M., Aaron, L. A., Stewart, K. E., AlarcóN, G. S., & Mountz, J. D. (1995) · Arthritis & Rheumatism · doi:10.1002/art.1780380708 · Cited by 387
[ 123 I]β-CIT SPECT imaging assessment of the rate of Parkinson’s disease progression
Marek, K., Innis, R., van Dyck, C., Fussell, B., Early, M., Eberly, S., Oakes, D., & Seibyl, J. (2001) · Neurology · doi:10.1212/wnl.57.11.2089 · Cited by 347
Ficaro, E. P., Fessler, J. A., Shreve, P. D., Kritzman, J. N., Rose, P. A., & Corbett, J. R. (1996) · Circulation · doi:10.1161/01.cir.93.3.463 · Cited by 313
EANM Dosimetry Committee guidelines for bone marrow and whole-body dosimetry
Hindorf, C., Glatting, G., Chiesa, C., Lindén, O., & Flux, G. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1422-4 · Cited by 297
Buck, A. K., Nekolla, S., Ziegler, S., Beer, A., Krause, B. J., Herrmann, K., Scheidhauer, K., Wester, H.-J., Rummeny, E. J., Schwaiger, M., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.050195 · Cited by 282
Computerized tomography with X-ray, emission, and ultrasound sources
Kak, A. C. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11440 · Cited by 264
Voxel-level comparison of arterial spin-labeled perfusion MRI and FDG-PET in Alzheimer disease
Chen, Y., Wolk, D. A., Reddin, J. S., Korczykowski, M., Martinez, P. M., Musiek, E. S., Newberg, A. B., Julin, P., Arnold, S. E., Greenberg, J. H., et al. (2011) · Neurology · doi:10.1212/wnl.0b013e31823a0ef7 · Cited by 259
Micro-CT of rodents: State-of-the-art and future perspectives
Clark, D. P., & Badea, C. T. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.05.011 · Cited by 229
“function [150]; then, the micro-CT volume is blurred with a 3D Gaussian kernel to match the resolution of the micro-PET image.”
Unmatched projector/backprojector pairs in an iterative reconstruction algorithm
Zeng, G. L., & Gullberg, G. T. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.870265 · Cited by 228
“Unmatched projector/backprojector pairs have been investigated and used in image reconstruction [1]–[6].”
BackgroundMethodRole of DAT‐SPECT in the diagnostic work up of Parkinsonism
Scherfler, C., Schwarz, J., Antonini, A., Grosset, D., Valldeoriola, F., Marek, K., Oertel, W., Tolosa, E., Lees, A. J., & Poewe, W. (2007) · Movement Disorders · doi:10.1002/mds.21505 · Cited by 219
Review and current status of SPECT scatter correction
Hutton, B. F., Buvat, I., & Beekman, F. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/14/r01 · Cited by 217
“Attenuation correction strategies include simple multiplicative correction based on knowledge of the attenuation coefficients and hence the average attenuation factor for photons originating from a given location (Chang 1978).”
BackgroundQuantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality
Bailey, D. L., & Willowson, K. P. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2542-4 · Cited by 196
“A more advanced approach is to employ the Chang algorithm using measured attenuation coefficients rather than assuming a constant homogeneous attenuation value [3].”
InfluentialAn attenuated projector-backprojector for iterative SPECT reconstruction
Gullberg, G. T., Huesman, R. H., Malko, J. A., Pelc, N. J., & Budinger, T. F. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/8/004 · Cited by 173
Cognitive impairment in chronic obstructive pulmonary disease
Antonelli Incalzi, R., Marra, C., Giordano, A., Calcagni, M. L., Cappa, A., Basso, S., Pagliari, G., & Fuso, L. (2003) · Journal of Neurology · doi:10.1007/s00415-003-1005-4 · Cited by 172
Munley, M. T., Marks, L. B., Scarfone, C., Sibley, G. S., Patz, E. F., Turkington, T. G., Jaszczak, R. J., Gilland, D. R., Anscher, M. S., & Coleman, R. E. (1999) · Lung Cancer · doi:10.1016/s0169-5002(99)00005-7 · Cited by 171
“11/cm [16].”
Reduced Striatal Dopamine Transporters in People with Internet Addiction Disorder
Hou, H., Jia, S., Hu, S., Fan, R., Sun, W., Sun, T., & Zhang, H. (2012) · Journal of Biomedicine and Biotechnology · doi:10.1155/2012/854524 · Cited by 165
Lee, J. S., Kim, B. N., Kang, E., Lee, D. S., Kim, Y. K., Chung, J., Lee, M. C., & Cho, S. C. (2005) · Human Brain Mapping · doi:10.1002/hbm.20067 · Cited by 134
Dopamine transporter binding in Gilles de la Tourette syndrome
Müller-Vahl, K. R., Berding, G., Brücke, T., Kolbe, H., Meyer, G. J., Hundeshagen, H., Dengler, R., Knapp, W. H., & Emrich, H. M. (2000) · Journal of Neurology · doi:10.1007/pl00007806 · Cited by 95
“12/cm [5].”
Kim, C.-H., Koo, M.-S., Cheon, K.-A., Ryu, Y.-H., Lee, J.-D., & Lee, H.-S. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1245-7 · Cited by 82
Age-related decline in nicotinic receptor availability with [123I]5-IA-85380 SPECT
Mitsis, E. M., Cosgrove, K. P., Staley, J. K., Bois, F., Frohlich, E. B., Tamagnan, G. D., Estok, K. M., Seibyl, J. P., & van Dyck, C. H. (2009) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2007.12.008 · Cited by 65
Makedonov, I., Black, S. E., & MacIntosh, B. J. (2013) · European Journal of Neurology · doi:10.1111/j.1468-1331.2012.03785.x · Cited by 62
“Ellipses were fitted to the approximate location of the outline of the head in each transaxial image, and a calculated attenuation correction was applied [18].”
MethodHerold, N., Uebelhack, K., Franke, L., Amthauer, H., Luedemann, L., Bruhn, H., Felix, R., Uebelhack, R., & Plotkin, M. (2006) · Journal of Neural Transmission · doi:10.1007/s00702-005-0429-7 · Cited by 61
Jia, S., Wang, W., Liu, Y., & Wu, Z. (2005) · Addiction Biology · doi:10.1080/13556210500222456 · Cited by 29
[99mTc]TRODAT-1/[123I]IBZM SPECT studies of the dopaminergic system in Tourette syndrome
Hwang, W.-J., Yao, W.-J., Fu, Y.-K., & Yang, A.-S. (2008) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2007.04.006 · Cited by 29
ANÇEVIĆ, V., ALAVI, A., SOUDER, E., MOZLEY, P. D., GUR, R. E., BÉNARD, F., & MUNZ, D. L. (2000) · Clinical Nuclear Medicine · doi:10.1097/00003072-200008000-00005 · Cited by 29
Amen, D. G., Harris, W. S., Kidd, P. M., Meysami, S., & Raji, C. A. (2017) · Journal of Alzheimer s Disease · doi:10.3233/jad-170281 · Cited by 25
“During image acquisition, Chang attenuation correction was performed [18].”
Chou, Y.-H., Hsieh, W.-C., Chen, L.-C., Lirng, J.-F., & Wang, S.-J. (2016) · Journal of Affective Disorders · doi:10.1016/j.jad.2015.10.056 · Cited by 23
Schizotypy trait and striatal dopamine receptors in healthy volunteers
Chen, K. C., Lee, I. H., Yeh, T. L., Chiu, N. T., Chen, P. S., Yang, Y. K., Lu, R.-B., & Chen, C. C. (2012) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2011.07.003 · Cited by 21
Evaluation of reference tissue model and tissue ratio method for 5-HTT using [123I] ADAM tracer
Yang, B.-H., Wang, S.-J., Chou, Y.-H., Su, T.-P., Chen, S.-P., Lee, J.-S., & Chen, J.-C. (2008) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.02.011 · Cited by 10
Adrenoleukodystrophy: cortical hypoperfusion demonstrated with 99mTc-HMPAO SPECT
Al Suhaili, A. R., Hertecant, J., & Sztriha, L. (1994) · Journal of Child Neurology · doi:10.1177/088307389400900312 · Cited by 4
Metadata
- Authors
- Chang, L.-T.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 1978
- Volume
- 25
- Issue
- 1
- Pages
- 638-643
- ISSN
- 0018-9499 (ISSN-L)
- OpenAlex
- W2060724489
- Cited by
- 1,297
- References
- 0
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.