Modulation strategy to operate the dual active bridge DC-DC converter under soft switching in the whole operating range
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
A new modulation strategy that allows operating the dual active bridge (DAB) dc-dc converter under soft switching in the whole operating range is proposed. This strategy is ruled by imposing a certain modulation index in one of the two bridges and a phase shift between the transformer primary and secondary voltages. Moreover, the proposed algorithm reduces the reactive power and thus reducing the converter conduction losses. An experimental prototype was implemented and some experimental results are presented to validate the theoretical analysis. The experimental results reveal that the overall efficiency of the DAB topology can be improved up to 20% by implementing the proposed modulation strategy instead of the conventional one.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535
Instantaneous Power Theory and Applications to Power Conditioning
Akagi, H., Watanabe, E. H., & Aredes, M. (2007) · Wiley eBooks · doi:10.1002/0470118938 · Cited by 2,234
Performance characterization of a high-power dual active bridge DC-to-DC converter
Kheraluwala, M. N., Gascoigne, R. W., Divan, D. M., & Baumann, E. D. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.175280 · Cited by 1,496
Bai, H., & Mi, C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005103 · Cited by 1,121
Liserre, M., Sauter, T., & Hung, J. (2010) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2010.935861 · Cited by 1,054
A Bidirectional DC–DC Converter for an Energy Storage System With Galvanic Isolation
Inoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.909248 · Cited by 780
Inoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889939 · Cited by 669
Switching Control Strategy to Minimize Dual Active Bridge Converter Losses
Oggier, G. G., GarcÍa, G. O., & Oliva, A. R. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2020902 · Cited by 514
Self-citationTransformer-Coupled Multiport ZVS Bidirectional DC–DC Converter With Wide Input Range
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915129 · Cited by 478
Krismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 2×
“The DAB topology using the conventional modulation strategy (CMS) can operate under soft switching, thus minimizing the power semiconductor switching losses, but only within a reduced range of operation, depending on the voltage conversion ratio and on the output current [4], [14], [15].”
BackgroundMethod
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932
“Then the circulating power and current stress are increased, which result in great loss in power devices and magnetic components and low efficiency of converter [16], [19]–[23].”
BackgroundExtreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
“In [103], the DPS is adopted to achieve ZVS under full load range.”
MethodClosed Form Solution for Minimum Conduction Loss Modulation of DAB Converters
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2157976 · Cited by 635
Generalized Average Modeling of Dual Active Bridge DC–DC Converter
Qin, H., & Kimball, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2165734 · Cited by 557
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Optimal ZVS Modulation of Single-Phase Single-Stage Bidirectional DAB AC–DC Converters
Everts, J., Krismer, F., Van den Keybus, J., Driesen, J., & Kolar, J. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2292026 · Cited by 501
Huang, J., Wang, Y., Li, Z., & Lei, W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2543182 · Cited by 501
Tong, A., Hang, L., Li, G., Jiang, X., & Gao, S. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2692276 · Cited by 455
Zhao, B., Song, Q., & Liu, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2189586 · Cited by 406
Minimum-Current-Stress Scheme of Dual Active Bridge DC-DC Converter With Unified-phase-shift Control
Hou, N., Song, W., & wu, M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2521410 · Cited by 369
Khalid, M. R., Khan, I. A., Hameed, S., Asghar, M. S. J., & Ro, J. (2021) · IEEE Access · doi:10.1109/access.2021.3112189 · Cited by 353
Rodriguez, A., Vazquez, A., Lamar, D. G., Hernando, M. M., & Sebastian, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309853 · Cited by 352
Zhao, B., Song, Q., Liu, W., & Sun, W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2210374 · Cited by 345
Zhao, B., Song, Q., & Liu, W. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2210563 · Cited by 325
High-Power Bidirectional DC–DC Converter for Aerospace Applications
Naayagi, R. T., Forsyth, A. J., & Shuttleworth, R. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2184771 · Cited by 305
“Although various modes of operation of the DAB converter have been presented recently [20], [26], [28] for highpower operation, the square-wave mode is supposedly the best operating mode.”
MethodHossain, M. Z., Rahim, N. A., & Selvaraj, J. A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.017 · Cited by 305
Bidirectional Onboard Chargers for Electric Vehicles: State-of-the-Art and Future Trends
Wouters, H., & Martinez, W. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3319996 · Cited by 280
A Bidirectional LLC Resonant Converter With Automatic Forward and Backward Mode Transition
Jiang, T., Zhang, J., Wu, X., Sheng, K., & Wang, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2307329 · Cited by 264
A High-Efficiency High-Density Wide-Bandgap Device-Based Bidirectional On-Board Charger
Li, B., Li, Q., Lee, F. C., Liu, Z., & Yang, Y. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2845846 · Cited by 259
“For the isolated dc/dc stage, the dual active bridge dc/dc converter can only achieve ZVS under heavy load [14], and the control becomes very complex when ZVS is desired under light load condition [15].”
BackgroundWeise, N. D., Castelino, G., Basu, K., & Mohan, N. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293112 · Cited by 223
“Duty cycle modulation of only one/single H-Bridge (SHBM) was first introduced in [29] and extensively studied in [9], [30], and [31].”
BackgroundClosed-Loop Control of DC–DC Dual-Active-Bridge Converters Driving Single-Phase Inverters
Qin, H., & Kimball, J. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2257859 · Cited by 212
Xue, F., Yu, R., & Huang, A. Q. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2686307 · Cited by 199
“This type of modulation is called triangular current mode modulation or extended phase-shift modulation [10], [11].”
BackgroundWen, H., Xiao, W., & Su, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2316229 · Cited by 179
“PSPWM Phase-shift plus pulsewidth modulation.”
BackgroundInfluentialZhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2271511 · Cited by 178
“The authors in [5]–[7], [21] and [22] proposed a family of hybrid optimized control algorithm for the IBDC to improve the circulating current characteristics, decrease current stress, enhance power transmission capacity and so on.”
Closed-Form Solution for Efficient ZVS Modulation of DAB Converters
Everts, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2633507 · Cited by 175
“, as in [2], [3], [7], [13], and [14].”
High-Efficiency SiC-Based Isolated Three-Port DC/DC Converters for Hybrid Charging Stations
Dao, N. D., Lee, D.-C., & Phan, Q. D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2975124 · Cited by 174
He, P., Mallik, A., Sankar, A., & Khaligh, A. (2019) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2018.2881276 · Cited by 154
“Among different existing DC-DC conversion circuit topologies, dual active bridge (DAB) [6], [7] and CLLC converters [7]–[13] have received significant attention due to their simple and symmetric structure on both sides of the high-frequency (HF) transformer.”
BackgroundMinimum-RMS-current operation of asymmetric dual active half-bridge converters with and without ZVS
Chakraborty, S., & Chattopadhyay, S. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2613874 · Cited by 72
A Critical Review on Charging Technologies of Electric Vehicles
Shahjalal, M., Shams, T., Tasnim, M. N., Ahmed, M. R., Ahsan, M., & Haider, J. (2022) · Energies · doi:10.3390/en15218239 · Cited by 66
“…strategies have been proposed to reduce the reactive current in the active bridges such as pulse-width modulation (PWM) with phase shift [49–52] and triangular and trapezoidal modulation Although the topology reduces the capacitor requirements of traditional DAB topology, the additional…”
BackgroundA bidirectional three-phase push–pull converter with dual asymmetrical PWM method
Kwon, M., Park, J., & Choi, S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2431273 · Cited by 47
3.3kW CLLC converter with synchronous rectification for plug-in electric vehicles
Zou, S., Lu, J., Mallik, A., & Khaligh, A. (2017) · 2017 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.2017.8101708 · Cited by 39
“Therefore, researchers have proposed an improved DAB control strategy in [8] to improve efficiency, through implementing a modified modulation index in one of the two bridge legs and a phase shift between the primary and secondary voltages.”
BackgroundBidirectional converter for high-efficiency fuel cell powertrain
Fardoun, A. A., Ismail, E. H., Sabzali, A. J., & Al-Saffar, M. A. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2013.10.122 · Cited by 38
Nonlinear $C_{oss}-V_{DS}$ Profile Based ZVS Range Calculation for Dual Active Bridge Converters
Liu, B., Davari, P., & Blaabjerg, F. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3003248 · Cited by 35
“, currentbased method [7], [8] and energy-based method [9].”
MethodHigh efficiency wide range bidirectional DC/DC converter for OBCM application
Liu, G., Li, D., Zhang, J. Q., & Jia, M. L. (2014) · 2014 International Power Electronics and Application Conference and Exposition · doi:10.1109/peac.2014.7038075 · Cited by 16
Metadata
- Authors
- Oggier, G. G., Garcia, G. O., & Oliva, A. R.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2011-04
- Volume
- 26
- Issue
- 4
- Pages
- 1228-1236
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2138700137
- Cited by
- 498
- References
- 21
- FWCI
- 11.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.