CoChat

Trace determination of lead in lipsticks and hair dyes using microwave‐assisted dispersive liquid–liquid microextraction and graphite furnace atomic absorption spectrometry

Sharafi, K., Fattahi, N., Pirsaheb, M., Yarmohamadi, H., Fazlzadeh Davil, M. · 2015 · International Journal of Cosmetic Science
Cited by 61

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Synopsis: Objective: A novel microwave‐assisted dispersive liquid–liquid microextraction (MADLLME) technique according to the solidification of a floating organic droplet (SFO) and graphite furnace atomic absorption spectrometry (GFAAS) used for the extraction and determination of lead ions in lipsticks and hair dyes made in different countries. Lipstick and hair dye samples of different brands and colours were collected from local market in Kermanshah, Iran. Methods: After sample treatment with microwave‐assisted acid digestion, an appropriate mixture of acetone, 1‐undecanol and diethyl dithiophosphoric acid was injected rapidly into the aqueous sample containing lead ions, and as a result, cloudy mixture was formed. After centrifugation, the test tube was cooled for few minutes. The solidified 1‐undecanol on top of the solution was transferred into a suitable vial and injected into the analytical instrument. Results: Under the optimum experimental conditions (extraction solvent: 30 μL of 1‐undecanol; disperser solvent: 500 μL of acetone; ligand concentration: 0.15% (v/v); pH: ~1.5 and without salt added), the enhancement factor of 96 was obtained. The calibration graphs were linear in the range of 0.3–50 μg kg−1 with a correlation coefficient (r2) more than 0.995. The detection limit was 0.1 μg kg−1. Consequently, the developed method was successfully applied to extract and determine lead ions in the lipsticks and hair dyes, and favourable results were obtained. The proposed method which applied in cosmetics showed excellent relative recoveries (90–109.7%) with relative standard deviations <8.3% (n = 3) for all samples. Conclusion: The study revealed that the concentration of lead found in lipsticks and hair dyes on the Kermanshah market is far below the recommended limits as applied in Germany (20 mg kg−1) and Canada (10 mg kg−1) and confirmed that very low levels of lead are technically available in the final cosmetic products.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/ics.12221

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Research works printed but not linked: 22

  1. 10.1016/j.talanta.2012.09.021 · DOI
  2. 10.1016/j.microc.2011.10.008 · DOI · Paper page
  3. 10.1016/j.jhazmat.2009.11.045 · DOI
  4. 10.1289/ehp.6941 · DOI · Paper page
  5. 10.1016/j.chroma.2008.10.041 · DOI
  6. 10.1016/j.yrtph.2009.02.005 · DOI · Paper page
  7. Hepp N.M., 2009, Determination of total lead in lipstick: development and validation of a microwave‐assisted digestion, inductively coupled plasma–mass spectrometric method, J. Cosmet. Sci., 60, 405
  8. Besecker K.D., 1998, A simple closed‐vessel nitric acid digestion method for cosmetic samples, Atom. Spectros., 19, 48
  9. 10.1016/j.jhazmat.2009.10.069 · DOI · Paper page
  10. 10.1016/j.sab.2009.03.002 · doi:10.1016/j.sab.2009.03.002
  11. 10.1016/j.talanta.2005.08.027 · DOI
  12. 10.1016/j.jhazmat.2006.09.075 · DOI
  13. 10.1039/b204367j · DOI
  14. 10.1111/ics.12023 · doi:10.1111/ics.12023
  15. 10.1016/j.jhazmat.2008.03.100 · DOI
  16. 10.1016/j.sab.2008.09.018 · DOI
  17. 10.1007/s13738-013-0294-5 · DOI
  18. 10.1016/j.talanta.2010.02.035 · DOI
  19. 10.1016/j.talanta.2007.11.009 · DOI
  20. 10.1016/j.talanta.2012.05.063 · DOI · Paper page
  21. 10.1016/j.aca.2008.01.020 · DOI
  22. 10.1016/j.jpba.2012.11.047 · DOI

Cited by

Metadata

Authors
Sharafi, K., Fattahi, N., Pirsaheb, M., Yarmohamadi, H., & Fazlzadeh Davil, M.
Venue
International Journal of Cosmetic Science
Publisher
Wiley
Published
2015-05-04
Volume
37
Issue
5
Pages
489-495
ISSN
  • 0142-5463 (ISSN-L)
  • 1468-2494
OpenAlex
W2066025574
Cited by
61
References
6
FWCI
7.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Trace determination of lead in lipsticks and hair dyes using microwave‐assisted dispersive liquid–liquid microextraction and graphite furnace atomic absorption spectrometry. https://app.cochat.ai/papers/10.1111/ics.12221
The paper
Sharafi, K., Fattahi, N., Pirsaheb, M., Yarmohamadi, H., & Fazlzadeh Davil, M. (2015). Trace determination of lead in lipsticks and hair dyes using microwave‐assisted dispersive liquid–liquid microextraction and graphite furnace atomic absorption spectrometry. International Journal of Cosmetic Science. https://doi.org/10.1111/ics.12221

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.