CoChat

Epidermal thickness assessed by optical coherence tomography and routine histology: preliminary results of method comparison

Gambichler, T, Boms, S, Stücker, M, Kreuter, A, Moussa, G, Sand, M, Altmeyer, P, Hoffmann, K · 2006 · Journal of the European Academy of Dermatology and Venereology
Cited by 73

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background Optical coherence tomography (OCT) is a promising non‐invasive imaging technique for studying the epidermis and upper dermis in vivo. As proposed previously by Welzel et al. (J Am Acad Dermatol 1997; 37: 958–963), distance measurements between the entrance peak and the second peak of the A‐scan seem to correspond to epidermal thickness (ET). However, there is a lack of systematic studies comparing OCT with histology. Methods Sixteen healthy subjects were included in this pilot study. OCT assessments were conducted on the upper back. To determine ET by OCT, the distance between the entrance peak and the second peak of the A‐scan was calculated (ET‐OCT). After OCT measurement a 4 mm punch biopsy was taken on each subject from the same site previously assessed. The maximum thickness of the epidermis (ET‐Histo) was determined microscopically using routine histological slices (formalin‐paraffin technique, haematoxylin–eosin staining). Correlation and agreement between the two methods were assessed by means of the Pearson correlation procedure and Bland–Altman plots, respectively. Results ET‐Histo was 79.4 ± 21.9 µm, including a stratum corneum thickness of 20 ± 12.1 µm. OCT measurements resulted in an ET of 106 ± 15.4 µm. No correlation between ET‐Histo and ET‐OCT was observed (r = 0.29, P = 0.27). There was a considerable lack of agreement between histology and OCT measurements as expressed in a high bias of 26.63 µm [95% confidence interval (CI) 14.49–38.77]. Furthermore, the lower 95% limits of agreement were −18.03 µm (95% CI −37.11 to 1.05) and the upper 95% limits of agreement were 71.28 µm (95% CI 52.2–90.36) indicating that ET‐OCT may be 71.28 µm above or 18.03 µm below ET‐Histo. Conclusions Our preliminary data suggest that the above‐described OCT algorithm is probably not a valid measure for the evaluation of ET. The second peak of the A‐scan seems not to correspond to the dermo‐epidermal junction zone, but rather to fibrous structures in the upper dermis. Nevertheless, further systematic comparison studies between OCT and histology are warranted, using different OCT algorithms for ET determination and cryopreparation, which has a higher reliability than the formalin‐paraffin technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1468-3083.2006.01629.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Research works printed but not linked: 23

  1. 10.1111/j.1365-2133.1973.tb03007.x · DOI · Paper page
  2. 10.1111/j.1600-0846.1998.tb00106.x · DOI
  3. 10.1515/bmte.2003.48.5.116 · DOI · Paper page
  4. Gambichler T, 2003, Bioengineering of the skin: non‐invasive methods for the evaluation of efficacy, Trends Clin Exp Dermatol, 1, 32
  5. 10.1016/j.jdermsci.2005.07.006 · DOI · Paper page
  6. 10.1117/1.1645795 · DOI · Paper page
  7. GambichlerT BomsS StuckerMet al.Acute skin alterations following ultraviolet radiation investigated by optical coherence tomography and histology.Arch Dermatol Res2005;297:218–225. · DOI
  8. 10.1016/S0190-9622(97)70072-0 · DOI · Paper page
  9. 10.1111/j.1365-2133.2004.05810.x · DOI
  10. 10.1007/s00403-003-0390-y · DOI · Paper page
  11. 10.1002/1098-2353(2000)13:6<429::AID-CA6>3.0.CO;2-5 · DOI
  12. 10.1111/j.1600-0846.1999.tb00120.x · DOI
  13. 10.1034/j.1600-0846.2000.006001006.x · DOI · Paper page
  14. 10.1111/j.1600-0846.2004.00038.x · DOI · Paper page
  15. 10.1111/1523-1747.ep12701670 · DOI · Paper page
  16. 10.1046/j.1523-1747.1999.00795.x · doi:10.1046/j.1523-1747.1999.00795.x
  17. 10.1111/j.1600-0846.2004.00067.x · DOI
  18. 10.1159/000247302 · doi:10.1159/000247302
  19. 10.1111/1523-1747.ep12606215 · DOI · Paper page
  20. 10.1046/j.0909-752x.2001.10297.x · DOI · Paper page
  21. 10.1002/ar.1090860406 · DOI
  22. 10.1364/OPEX.12.005760 · DOI
  23. 10.1117/1.2039086 · DOI · Paper page

Cited by

Metadata

Authors
Gambichler, T., Boms, S., Stücker, M., Kreuter, A., Moussa, G., Sand, M., Altmeyer, P., & Hoffmann, K.
Venue
Journal of the European Academy of Dermatology and Venereology
Publisher
Wiley
Published
2006-06-09
Volume
20
Issue
7
Pages
791-795
ISSN
  • 0926-9959 (ISSN-L)
  • 1468-3083
OpenAlex
W2048805191
Cited by
73
References
4
FWCI
3.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.