Responses of neurones of the rat suprachiasmatic nucleus to retinal illumination under photopic and scotopic conditions
Open accessThe DOI matches its Crossref record.
Abstract
We have examined the responses of neurones in the suprachiasmatic nuclei (SCN) of the rat to retinal illumination under photopic and scotopic conditions to identify the types of photoreceptor input to these nuclei. The majority of visually responsive SCN neurones studied under dark adaptation received rod input (48 of 52, 92 %). The action spectrum conformed to the sensitivity of rhodopsin, with maximal sensitivity at around 505 nm. When also studied under light adaptation, most visually responsive SCN neurones (20 out of 26, 77 %) responded to input from cones. The action spectra conformed to the spectrum of green cone opsin, with a main sensitivity peak at 510 nm and a significant secondary peak in the near‐ultraviolet region of the spectrum. The frequency of spontaneous activity was typically low under scotopic conditions (range 0.2‐17.2 Hz) and higher under photopic conditions (range 0.6‐40 Hz) for any given neurone. The most common response under scotopic conditions was an ‘on‐excitation’ (32 of 48, 62.5 %), which changed under photopic conditions to an on‐excitation followed by a more prominent off‐inhibition. Responses also changed due to endogenous ultradian cycles. Depending on the phase, responses could be altogether absent and even reverted from excitation to inhibition on opposite phases of a cycle. Ultradian cycles had a circadian dependence and were most common at around the light phase:dark phase (L:D) and D:L transition points of the circadian cycle. Under photopic conditions, SCN neurones showed rhythmic electrical activity, with a preferred firing interval that had a value between 18 and 39 ms. This rhythmic activity was probably the result of endogenous subthreshold membrane potential oscillations. In conclusion, light acting either via rod or cone pathways could have powerful, opposing actions on SCN neurones. These actions were state dependent. The presence of these neuronal responses suggests a role for rod and cone photoreceptors in SCN function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Phototransduction by retinal ganglion cells that set the circadian clock
Berson, D. M., Dunn, F. A., & Takao, M. (2002) · Science · doi:10.1126/science.1067262 · Cited by 3,629
Hattar, S., Liao, H.-W., Takao, M., Berson, D. M., & Yau, K.-W. (2002) · Science · doi:10.1126/science.1069609 · Cited by 2,734
Action Spectrum for Melatonin Regulation in Humans: Evidence for a Novel Circadian Photoreceptor
Brainard, G. C., Hanifin, J. P., Greeson, J. M., Byrne, B., Glickman, G., Gerner, E., & Rollag, M. D. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-16-06405.2001 · Cited by 1,930
Physiology of Circadian Entrainment
Golombek, D. A., & Rosenstein, R. E. (2010) · Physiological Reviews · doi:10.1152/physrev.00009.2009 · Cited by 1,096
Central projections of melanopsin‐expressing retinal ganglion cells in the mouse
Hattar, S., Kumar, M., Park, A., Tong, P., Tung, J., Yau, K., & Berson, D. M. (2006) · Journal of Comparative Neurology · doi:10.1002/cne.20970 · Cited by 996
“Electrophysiological and behavioral evidence strongly suggests that conventional rod and cone photoreceptors can drive SCN unit responses and circadian phase shifts (Aggelopoulos and Meissl, 2000; Panda et al, 2002, 2003; Ruby et al., 2002; Lucas et al., 2003; Hattar et al, 2003).”
BackgroundThe circadian visual system, 2005
Morin, L. P., & Allen, C. N. (2006) · Brain Research Reviews · doi:10.1016/j.brainresrev.2005.08.003 · Cited by 784
Strange vision: ganglion cells as circadian photoreceptors
Berson, D. (2003) · Trends in Neurosciences · doi:10.1016/s0166-2236(03)00130-9 · Cited by 546
A Broad Role for Melanopsin in Nonvisual Photoreception
Gooley, J. J., Lu, J., Fischer, D., & Saper, C. B. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-18-07093.2003 · Cited by 480
Effect of Light on Human Circadian Physiology
Duffy, J. F., & Czeisler, C. A. (2009) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2009.01.004 · Cited by 472
Gooley, J. J., Rajaratnam, S. M. W., Brainard, G. C., Kronauer, R. E., Czeisler, C. A., & Lockley, S. W. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000741 · Cited by 447
A model of phototransduction by the human circadian system
Rea, M. S., Figueiro, M. G., Bullough, J. D., & Bierman, A. (2005) · Brain Research Reviews · doi:10.1016/j.brainresrev.2005.07.002 · Cited by 379
Distinct Contributions of Rod, Cone, and Melanopsin Photoreceptors to Encoding Irradiance
Lall, G. S., Revell, V. L., Momiji, H., Al Enezi, J., Altimus, C. M., Güler, A. D., Aguilar, C., Cameron, M. A., Allender, S., Hankins, M. W., et al. (2010) · Neuron · doi:10.1016/j.neuron.2010.04.037 · Cited by 293
Rea, M. S., Figueiro, M. G., Bierman, A., & Bullough, J. D. (2010) · Journal of Circadian Rhythms · doi:10.1186/1740-3391-8-2 · Cited by 279
“For example, Aggelopolous and Meissl [37] suggest that there are multiple neural pathways providing input to the SCN in rats.”
BackgroundGanguly, S., Coon, S. L., & Klein, D. C. (2002) · Cell and Tissue Research · doi:10.1007/s00441-002-0579-y · Cited by 275
McDougal, D. H., & Gamlin, P. D. (2010) · Vision Research · doi:10.1016/j.visres.2009.10.012 · Cited by 273
Vandewalle, G., Schmidt, C., Albouy, G., Sterpenich, V., Darsaud, A., Rauchs, G., Berken, P.-Y., Balteau, E., Degueldre, C., Luxen, A., et al. (2007) · PLoS ONE · doi:10.1371/journal.pone.0001247 · Cited by 273
Synaptic influences on rat ganglion‐cell photoreceptors
Wong, K. Y., Dunn, F. A., Graham, D. M., & Berson, D. M. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.133751 · Cited by 267
Light as a circadian stimulus for architectural lighting
Rea, M., & Figueiro, M. (2018) · Lighting Research & Technology · doi:10.1177/1477153516682368 · Cited by 264
Calcium Imaging Reveals a Network of Intrinsically Light-Sensitive Inner-Retinal Neurons
Sekaran, S., Foster, R. G., Lucas, R. J., & Hankins, M. W. (2003) · Current Biology · doi:10.1016/s0960-9822(03)00510-4 · Cited by 234
In Search of the Pathways for Light-Induced Pacemaker Resetting in the Suprachiasmatic Nucleus
Meijer, J. H., & Schwartz, W. J. (2003) · Journal of Biological Rhythms · doi:10.1177/0748730403018003006 · Cited by 226
“Extracellular single-unit recordings show that 32% and 38% of SCN neurons are lightresponsive in the rat and hamster, respectively (Groos and Mason, 1980; Meijer et al., 1986; Kim and Dudek, 1993; Cui and Dyball, 1996; Jiang et al., 1997; Aggelopoulos and Meissl, 2000).”
BackgroundVetter, C., Pattison, P. M., Houser, K., Herf, M., Phillips, A. J. K., Wright, K. P., Skene, D. J., Brainard, G. C., Boivin, D. B., & Glickman, G. (2022) · LEUKOS · doi:10.1080/15502724.2021.1872383 · Cited by 222
“The retinohypothalamic tract (RHT) is responsible for carrying light information from the retina to the suprachiasmatic nuclei (SCN) in the hypothalamus.”
ResultInfluentialPhotoreceptor Adaptation in Intrinsically Photosensitive Retinal Ganglion Cells
Wong, K. Y., Dunn, F. A., & Berson, D. M. (2005) · Neuron · doi:10.1016/j.neuron.2005.11.016 · Cited by 213
Lucas, R. J., Lall, G. S., Allen, A. E., & Brown, T. M. (2012) · Progress in brain research · doi:10.1016/b978-0-444-59427-3.00001-0 · Cited by 195
Non-rod, non-cone photoreception in the vertebrates
Foster, R. G., & Hankins, M. W. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00036-8 · Cited by 192
Morin, L. P., Blanchard, J. H., & Provencio, I. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10881 · Cited by 184
“Cells in the SCN and OPT have been reported to respond to rod- and conemediated inputs (Aggelopoulos and Meissl, 2000; Lucas et al., 2001b).”
BackgroundPhotoresponse diversity among the five types of intrinsically photosensitive retinal ganglion cells
Zhao, X., Stafford, B. K., Godin, A. L., King, W. M., & Wong, K. Y. (2014) · The Journal of Physiology · doi:10.1113/jphysiol.2013.262782 · Cited by 178
“…the master circadian pacemaker (Berson et al. 2002; Hattar et al. 2006), is consistent with the high sensitivity of SCN neurons to dim light (Aggelopoulos & Meissl, 2000), the low-intensity threshold for circadian photoentrainment (Butler & Silver, 2011) and the ability of rods to drive…”
BackgroundMelanopsin-Dependent Nonvisual Responses: Evidence for Photopigment Bistability In Vivo
Mure, L. S., Rieux, C., Hattar, S., & Cooper, H. M. (2007) · Journal of Biological Rhythms · doi:10.1177/0748730407306043 · Cited by 176
Dumitrescu, O. N., Pucci, F. G., Wong, K. Y., & Berson, D. M. (2009) · Journal of Comparative Neurology · doi:10.1002/cne.22158 · Cited by 174
Photons, Clocks, and Consciousness
Brainard, G. C., & Hanifin, J. P. (2005) · Journal of Biological Rhythms · doi:10.1177/0748730405278951 · Cited by 172
“Under normal photopic and scotopic conditions, a study showed that light-induced activation of retinal rods and cones has potent contrasting effects on rat SCN neurons (Aggelopoulos and Meissl, 2000).”
BackgroundInfluentialSchmidt, T. M., Taniguchi, K., & Kofuji, P. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00062.2008 · Cited by 170
Alerting effects of light are sensitive to very short wavelengths
Revell, V. L., Arendt, J., Fogg, L. F., & Skene, D. J. (2006) · Neuroscience Letters · doi:10.1016/j.neulet.2006.01.032 · Cited by 166
Circadian Photoentrainment in Mice and Humans
Foster, R. G., Hughes, S., & Peirson, S. N. (2020) · Biology · doi:10.3390/biology9070180 · Cited by 164
Age-Related Changes in Acute and Phase-Advancing Responses to Monochromatic Light
Sletten, T. L., Revell, V. L., Middleton, B., Lederle, K. A., & Skene, D. J. (2009) · Journal of Biological Rhythms · doi:10.1177/0748730408328973 · Cited by 137
“In addition, there is growing support that the classical rod and cone photoreceptors also contribute to the NIF light responses in rodents (Aggelopoulos and Meissl 2000; Belenky et al., 2003; Lucas et al., 2003), nonhuman primates (Dacey et al.”
BackgroundPhotic Entrainment of the Circadian System
Ashton, A., Foster, R., & Jagannath, A. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23020729 · Cited by 106
“This finding is consistent with the observation that rods drive electrical responses in light-sensitive SCN neurons under low light conditions [22].”
ResultIn synch but not in step: Circadian clock circuits regulating plasticity in daily rhythms
Evans, J. A., & Gorman, M. R. (2016) · Neuroscience · doi:10.1016/j.neuroscience.2016.01.072 · Cited by 49
“Further, light does not indiscriminately excite all SCN neurons; instead, photic stimuli activate only ∼25% of SCN neurons and inhibit a smaller population (Meijer et al., 1986, Jiao et al., 1999, Aggelopoulos and Meissl, 2000, Nakamura et al., 2004 and Brown et al., 2011).”
Metadata
- Authors
- Aggelopoulos, N. C., & Meissl, H.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2000-02
- Volume
- 523
- Issue
- 1
- Pages
- 211-222
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1972391438
- Cited by
- 143
- References
- 0
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.