Recommendations for Blood Pressure Measurement in Humans: An AHA Scientific Statement from the Council on High Blood Pressure Research Professional and Public Education Subcommittee
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Ten years have passed since the last version of the American Heart Association (AHA) blood pressure (BP) measurement recommendations,1 during which time there have been major changes in the ways in which BP is measured in clinical practice and research; hence this document represents a major revision of previous versions.2 BP determination continues to be one of the most important measurements in clinical medicine, and still one of the most inaccurately performed. The gold standard for clinical BP measurement has always been readings taken by a trained health care provider using a mercury sphygmomanometer and the Korotkoff sound technique. There is increasing evidence, however, that this procedure may lead to the misclassification of large numbers of individuals as hypertensive, and fail to diagnose other individuals whose BP may be normal in the clinic setting but elevated at other times. There are three reasons for this: 1) inaccuracies in the methods, some of which are avoidable; 2) the inherent variability of BP; and 3) the tendency for BP to increase in the presence of a physician (the so-called "white coat effect"). Numerous surveys have shown that physicians and other health care providers rarely follow established guidelines for BP measurement, but when they do, the readings they get correlate more closely with more objective measures of BP than the usual clinic readings. It is generally agreed that conventional clinic readings, when made correctly, are a surrogate marker for a patient's true BP, which is conceived as the average level over prolonged periods of time, and which is thought to be the most important component of BP in determining its adverse effects. Usual clinic readings give a poor estimate of this, not only because of poor technique, but also because they typically consist only of one or two individual measurements, and the beat-to-beat BP variability is such that a small number of readings may only give a crude estimate of the average level. The recognition of these limitations of traditional clinic readings has led to two parallel developments: first, increasing use of measurements out of the clinic, which avoids the unrepresentative nature of the clinic setting and also allows for an increased number of readings; and second, the increased use of automated devices, which are being used both in and out of the office setting. This decreased reliance on traditional readings has been accelerated by the fact that mercury is being banned in many countries, although there is still uncertainty as to what will replace it. Several dimensions of BP are associated with an increased risk of vascular disease. Clinic-based measurements that predict vascular disease include systolic and diastolic BP as well as mean arterial pressure and pulse pressure. Several studies have attempted to tease apart the relative importance of these measurements.3,4 Despite evolving interest in pulse pressure, the best available evidence still supports the use of systolic and diastolic BPs to classify individuals. As adults age, systolic BP tends to rise and diastolic BP tends to fall. When the average systolic BP is ≥140 and diastolic BP is <90 the patient is classified as having ISH. The increased pulse pressure (systolic − diastolic) and systolic pressure predict risk and determine treatment.5 In older children and young adults, more often males, the combination of rapid growth in height and very elastic arteries accentuates the normal amplification of the pressure wave between the aorta and brachial artery, resulting in a high systolic pressure in the brachial artery, but normal diastolic and mean pressures. The aortic systolic pressure is normal, however. This can be suspected from pulse wave analysis.6 More commonly in some younger adults, IDH is defined as systolic BP <140 and diastolic BP ≥90. Although diastolic pressure is generally believed to be the best predictor of risk in patients under the age of 50, some prospective studies of isolated diastolic hypertension have indicated that the prognosis may be benign.7 This topic remains controversial. WCH is commonly defined as a persistently elevated average office BP of >140/90 and an average awake ambulatory reading of <135/85 mm Hg, and occurs in about 15%–20% of people with stage 1 hypertension.8 Patients with WCH may progress to sustained hypertension and need to be followed carefully with office and out-of-office measurements of BP. Treatment with antihypertensive drugs may lower the office BP but does not change the ambulatory measurements.9 Somewhat less frequent than WCH, but more problematic to detect, is the converse condition—normal BP in the office and elevated BPs elsewhere, e.g., at work or at home. There is some evidence that such patients have more target organ damage and are at higher risk than subjects who are normotensive all the time.10 In a small number of elderly patients, the peripheral muscular arteries become very rigid, such that the
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
National High Blood Pressure Education Program Working Group on High Blood Pressure in Children and Adolescents (2004) · PEDIATRICS · doi:10.1542/peds.114.2.s2.555 · Cited by 6,938
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Self-citationPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Self-citationIs Pulse Pressure Useful in Predicting Risk for Coronary Heart Disease?: The Framingham Heart Study
Franklin, S. S., Khan, S. A., Wong, N. D., Larson, M. G., & Levy, D. (1999) · Circulation · doi:10.1161/01.cir.100.4.354 · Cited by 1,759
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationStaessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Human blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C., Flack, J., Frohlich, E. D., Hill, M., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,591
Self-citationFranklin, S. S., Larson, M. G., Khan, S. A., Wong, N. D., Leip, E. P., Kannel, W. B., & Levy, D. (2001) · Circulation · doi:10.1161/01.cir.103.9.1245 · Cited by 1,390
The Consensus Committee of the American Autonomic Society and the American Academy of Neurology (1996) · Neurology · doi:10.1212/wnl.46.5.1470 · Cited by 1,243
Prognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
OʼBrien, E., Pickering, T., Asmar, R., Myers, M., Parati, G., Staessen, J., Mengden, T., Imai, Y., Waeber, B., Palatini, P., et al. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00002 · Cited by 744
Self-citationSesso, H. D., Stampfer, M. J., Rosner, B., Hennekens, C. H., Gaziano, J. M., Manson, J. E., & Glynn, R. J. (2000) · Hypertension · doi:10.1161/01.hyp.36.5.801 · Cited by 599
Blood pressure control by home monitoring: meta-analysis of randomised trials
Cappuccio, F. P., Kerry, S. M., Forbes, L., & Donald, A. (2004) · BMJ · doi:10.1136/bmj.38121.684410.ae · Cited by 509
Relation Between Nocturnal Decline in Blood Pressure and Mortality The Ohasama Study
Ohkubo, T. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00274-4 · Cited by 491
Recommendations for the use of home (self) and ambulatory blood pressure monitoring
Pickering, T. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00341-x · Cited by 472
Self-citationRedon, J., Campos, C., Narciso, M. L., Rodicio, J. L., Pascual, J. M., & Ruilope, L. M. (1998) · Hypertension · doi:10.1161/01.hyp.31.2.712 · Cited by 420
Cardiovascular Outcome in White-Coat Versus Sustained Mild Hypertension: A 10-Year Follow-Up Study
Khattar, R. S., Senior, R., & Lahiri, A. (1998) · Circulation · doi:10.1161/01.cir.98.18.1892 · Cited by 299
Fagard, R. H., Staessen, J. A., Thijs, L., Gasowski, J., Bulpitt, C. J., Clement, D., de Leeuw, P. W., Dobovisek, J., Jääskivi, M., Leonetti, G., et al. (2000) · Circulation · doi:10.1161/01.cir.102.10.1139 · Cited by 285
Rogers, M. A. M., Small, D., Buchan, D. A., Butch, C. A., Stewart, C. M., Krenzer, B. E., & Husovsky, H. L. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-11-200106050-00008 · Cited by 246
Kario, K., Shimada, K., Schwartz, J. E., Matsuo, T., Hoshide, S., & Pickering, T. G. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01325-0 · Cited by 220
Self-citationOhkubo, T., Imai, Y., Tsuji, I., Nagai, K., Ito, S., Satoh, H., & Hisamichi, S. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.255 · Cited by 206
Task Force II: Blood pressure measurement and cardiovacular outcome
Staessen, J. A., Asmar, R., De Buyzere, M., Imai, Y., Parati, G., Shimada, K., Stergiou, G., Redón, J., & Verdecchia, P. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200112000-00016 · Cited by 187
Oscillometric blood pressure measurement: progress and problems
van Montfrans, G. A. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200112000-00004 · Cited by 175
Little, P., Barnett, J., Barnsley, L., Marjoram, J., Fitzgerald-Barron, A., & Mant, D. (2002) · BMJ · doi:10.1136/bmj.325.7358.254 · Cited by 171
Task Force V: White-coat hypertension
Pickering, T. G., Coats, A., Mallion, J. M., Mancia, G., & Verdecchia, P. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199912000-00006 · Cited by 150
Self-citationSpurious systolic hypertension of youth: fit young men with elastic arteries
Mahmud, A., & Feely, J. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)03255-7 · Cited by 144
Effect of Vertical Displacement of the Arm on Indirect Blood-Pressure Measurement
Mitchell, P. L., Parlin, R. W., & Blackburn, H. (1964) · New England Journal of Medicine · doi:10.1056/nejm196407092710204 · Cited by 125
Comparison of performance of various sphygmomanometers with intra-arterial blood-pressure readings.
Hunyor, S. N., Flynn, J. M., & Cochineas, C. (1978) · BMJ · doi:10.1136/bmj.2.6131.159 · Cited by 122
Effects of Anesthesia on Cardiovascular Control Mechanisms
Vatner, S. F. (1978) · Environmental Health Perspectives · doi:10.1289/ehp.7826193 · Cited by 118
Comparing compliance patterns between randomized treatments
Vrijens, B., & Goetghebeur, E. (1997) · Controlled Clinical Trials · doi:10.1016/s0197-2456(96)00235-8 · Cited by 114
Does self-measurement of blood pressure improve patient compliance in hypertension?
Edmonds, D., Foerster, E. H., Groth, H., Greminger, P., Siegenthaler, W. E., & Vetter, W. (1985) · PubMed · Cited by 104
Task Force V: White-coat hypertension
Pickering, T. G., Coats, A., Mallion, J. M., Mancia, G., & Verdecchia, P. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199900460-00006 · Cited by 104
Self-citation(1996) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(96)00206-7 · Cited by 90
The prognostic value of ambulatory blood pressure monitoring in treated hypertensive patients.
Perloff, D. L., Sokolow, M., & Cowan, R. (1991) · PubMed · Cited by 63
Isolated Diastolic Hypertension
Pickering, T. G. (2003) · The Journal of Clinical Hypertension · doi:10.1111/j.1524-6175.2003.02840.x · Cited by 55
Self-citationThe effect of crossing legs on blood pressure: a randomized single-blind cross-over study
Peters, G. L., Binder, S. K., & Campbell, N. R. C. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199900420-00007 · Cited by 55
Graves, J. W., Tibor, M., Murtagh, B., Klein, L., & Sheps, S. G. (2004) · Blood Pressure Monitoring · doi:10.1097/00126097-200402000-00004 · Cited by 55
Self-citationInfluence of the arm position on intra-arterial blood pressure measurement
Netea, R., Bijlstra, P. J., Lenders, J., Smits, P., & Thien, T. A. (1998) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000479 · Cited by 53
Measurement of blood pressure—a routine test in need of standardization
Thulin, T., Andersson, G., & Scherstén, B. (1975) · Postgraduate Medical Journal · doi:10.1136/pgmj.51.596.390 · Cited by 51
Imai, Y., Ohkubo, T., Tsuji, I., Nagai, K., Satoh, H., Hisamichi, S., & Abe, K. (1996) · Institutional Repositories DataBase (IRDB) · Cited by 39
Ambulatory monitoring and self-monitoring of blood pressure during pregnancy
Waugh, J. J. S., Halligan, A., & Shennan, A. H. (2000) · Blood Pressure Monitoring · doi:10.1097/00126097-200002000-00002 · Cited by 30
Verapmil and Nitrendipine in Hypertensive Patients Resistant to Betablocker
Edmonds, D., Foerster, E. C., Groth, H., Siegenthaler, W. E., & Vetter, W. (1985) · Journal of Hypertension · doi:10.1097/00004872-198508000-00033 · Cited by 27
Characterization of auscultatory gaps with wideband external pulse recording.
Blank, S. G., West, J. E., Müller, F., Pecker, M. S., Laragh, J. H., & Pickering, T. G. (1991) · Hypertension · doi:10.1161/01.hyp.17.2.225 · Cited by 23
Self-citation
Cited by
Schouten, J., Wit, F. W., Stolte, I. G., Kootstra, N. A., van der Valk, M., Geerlings, S. E., Prins, M., Reiss, P., for the AGEhIV Cohort Study Group, Reiss, P., et al. (2014) · Clinical Infectious Diseases · doi:10.1093/cid/ciu701 · Cited by 752
Macdougall, I. C., Bircher, A. J., Eckardt, K.-U., Obrador, G. T., Pollock, C. A., Stenvinkel, P., Swinkels, D. W., Wanner, C., Weiss, G., Chertow, G. M., et al. (2016) · Kidney International · doi:10.1016/j.kint.2015.10.002 · Cited by 482
He, J., Zhang, Y., Xu, T., Zhao, Q., Wang, D., Chen, C.-S., Tong, W., Liu, C., Xu, T., Ju, Z., et al. (2014) · JAMA · doi:10.1001/jama.2013.282543 · Cited by 452
Singh, A. K., Farag, Y. M., Mittal, B. V., Subramanian, K. K., Reddy, S. R. K., Acharya, V. N., Almeida, A. F., Channakeshavamurthy, A., Ballal, H. S., P, G., et al. (2013) · BMC Nephrology · doi:10.1186/1471-2369-14-114 · Cited by 420
Piper, M. A., Evans, C. V., Burda, B. U., Margolis, K. L., O'Connor, E., & Whitlock, E. P. (2015) · Annals of Internal Medicine · doi:10.7326/m14-1539 · Cited by 380
Metadata
- Authors
- Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J. W., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J.
- Venue
- The Journal of Clinical Hypertension
- Publisher
- Wiley
- Published
- 2005-02
- Volume
- 7
- Issue
- 2
- Pages
- 102-109
- ISSN
- 1524-6175 (ISSN-L)
- 1751-7176
- OpenAlex
- W2053840916
- Cited by
- 436
- References
- 44
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.