EEG source localization in focal epilepsy: Where are we now?
The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Abstract
Summary: Electroencephalographic source localization (ESL) by noninvasive means is an area of renewed interest in clinical epileptology. This has been driven by innovations in the computer‐assisted modeling of dipolar and distributed sources for the investigation of focal epilepsy; a process fueled by the ever‐increasing computational power available to researchers for the analysis of scalp EEG recordings. However, demonstration of the validity and clinical utility of these mathematically derived source modeling techniques has struggled to keep pace. This review evaluates the current clinical “fitness’ of ESL as applied to the focal epilepsies by examining some of the key studies performed in the field, with emphasis given to clinical work published in the last five years. In doing so, we discuss why ESL techniques have not made an impact on routine epilepsy practice, underlining some of the current problems and controversies in the field. We conclude by examining where ESL currently sits alongside magnetoencephalography and combined EEG‐functional magnetic resonance imaging in the investigation of focal epilepsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“However, MEGbased modeling has an inherent bias for superficial sources because the magnetic field decays very rapidly from scalp surface (Hamalainen et al., 1993).”
BackgroundPascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Fiber tracking: principles and strategies – a technical review
Mori, S., & van Zijl, P. C. M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.781 · Cited by 2,024
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
Electroencephalography: Basic Principles, Clinical Applications and Related Fields
Torres, F. (1983) · Archives of Neurology · doi:10.1001/archneur.1983.04050030085025 · Cited by 1,812
Presurgical evaluation of epilepsy
Rosenow, F. (2001) · Brain · doi:10.1093/brain/124.9.1683 · Cited by 1,669
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
The Variability of Human, BOLD Hemodynamic Responses
Aguirre, G. K., Zarahn, E., & D'Esposito, M. (1998) · NeuroImage · doi:10.1006/nimg.1998.0369 · Cited by 1,215
Basic Mechanisms of the Epilepsies.
(1970) · Annals of Internal Medicine · doi:10.7326/0003-4819-72-6-969_2 · Cited by 1,105
A standardized boundary element method volume conductor model
Fuchs, M., Kastner, J., Wagner, M., Hawes, S., & Ebersole, J. S. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00030-5 · Cited by 999
Vergleichende Lokalisationslehre der Grosshirnrinde
Jelliffe (1910) · The Journal of Nervous and Mental Disease · doi:10.1097/00005053-191012000-00013 · Cited by 767
Current Practice of Clinical Electroencephalography.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-92-4-582_3 · Cited by 732
Vergleichende Lokalisationslehre der Großhirnrinde
Brodmann, K. (1909) · Cited by 705
Principles of spatial analysis
Lehmann, D. (1987) · Medical Entomology and Zoology · Cited by 507
Engineering in Medicine and Biology Society, 2006.
Nambakhsh, Ahmadian, A., Ghavami, M., Dilmaghani, R., & Karimifard, S. (2006) · Cited by 458
Methods of Analysis of Brain Electrical and Magnetic Signals
Gevins, A. S., & Rémond, A. (1987) · Medical Entomology and Zoology · Cited by 451
Linear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436
Why Does Cerebral Cortex Fissure and Fold?
Welker, W. (1990) · Cerebral Cortex · doi:10.1007/978-1-4615-3824-0_1 · Cited by 425
Intracranial EEG Substrates of Scalp EEG Interictal Spikes
Tao, J. X., Ray, A., Hawes‐Ebersole, S., & Ebersole, J. S. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.11404.x · Cited by 424
Epileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
Basic mechanisms of the epilepsies
Merlis, J. K. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90055-6 · Cited by 385
Liu, A. K., Belliveau, J. W., & Dale, A. M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.15.8945 · Cited by 384
Menendez, R. G. D. P., Andino, S. G., Lantz, G., Michel, C. M., & Landis, T. (2001) · Brain Topography · doi:10.1023/a:1012944913650 · Cited by 348
Alarcon, G., Guy, C. N., Binnie, C. D., Walker, S. R., Elwes, R. D., & Polkey, C. E. (1994) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.57.4.435 · Cited by 319
Mapping human brain function with MEG and EEG: methods and validation
Darvas, F., Pantazis, D., Kucukaltun-Yildirim, E., & Leahy, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.014 · Cited by 310
EEG-triggered functional MRI of interictal epileptiform activity in patients with partial seizures
Krakow, K., Woermann, F. G., Symms, M. R., Allen, P. J., Lemieux, L., Barker, G. J., Duncan, J. S., & Fish, D. R. (1999) · Brain · doi:10.1093/brain/122.9.1679 · Cited by 305
Magnetic brain source imaging of focal epileptic activity: a synopsis of 455 cases
Stefan, H. (2003) · Brain · doi:10.1093/brain/awg239 · Cited by 304
Acquiring simultaneous EEG and functional MRI
Goldman, R. I., Stern, J. M., Engel, J., & Cohen, M. S. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00456-9 · Cited by 284
Combining EEG and fMRI: A multimodal tool for epilepsy research
Gotman, J., Kobayashi, E., Bagshaw, A. P., Bénar, C., & Dubeau, F. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20577 · Cited by 280
Seeck, M., Lazeyras, F., Michel, C. M., Blanke, O., Gericke, C. A., Ives, J., Delavelle, J., Golay, X., Haenggeli, C. A., de Tribolet, N., et al. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00017-0 · Cited by 259
Spatial sampling and filtering of EEG with spline Laplacians to estimate cortical potentials
Srinivasan, R., Nunez, P. L., Tucker, D. M., Silberstein, R. B., & Cadusch, P. J. (1996) · Brain Topography · doi:10.1007/bf01186911 · Cited by 244
Gloor, P. (1985) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-198510000-00002 · Cited by 244
Improving source reconstructions by combining bioelectric and biomagnetic data
Fuchs, M., Wagner, M., Wischmann, H.-A., Köhler, T., Theißen, A., Drenckhahn, R., & Buchner, H. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00046-7 · Cited by 239
Bagshaw, A. P., Aghakhani, Y., Bénar, C., Kobayashi, E., Hawco, C., Dubeau, F., Pike, G. B., & Gotman, J. (2004) · Human Brain Mapping · doi:10.1002/hbm.20024 · Cited by 227
The temporopolar cortex plays a pivotal role in temporal lobe seizures
Chabardès, S., Kahane, P., Minotti, L., Tassi, L., Grand, S., Hoffmann, D., & Benabid, A. L. (2005) · Brain · doi:10.1093/brain/awh512 · Cited by 209
Barkley, G. L., & Baumgartner, C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200305000-00002 · Cited by 202
The Electric Field of an Eccentric Dipole in a Homogeneous Spherical Conducting Medium
WILSON, F. N., & BAYLEY, R. H. (1950) · Circulation · doi:10.1161/01.cir.1.1.84 · Cited by 192
Phillips, C., Rugg, M. D., & Friston, K. J. (2002) · NeuroImage · doi:10.1006/nimg.2002.1143 · Cited by 191
128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision
Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200403000-00001 · Cited by 183
Negative BOLD responses to epileptic spikes
Kobayashi, E., Bagshaw, A. P., Grova, C., Dubeau, F., & Gotman, J. (2006) · Human Brain Mapping · doi:10.1002/hbm.20193 · Cited by 177
Defining Epileptogenic Foci: Past, Present, Future
Ebersole, J. S. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199711000-00003 · Cited by 173
Lantz, G., Spinelli, L., Seeck, M., de Peralta Menendez, R. G., Sottas, C. C., & Michel, C. M. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200309000-00003 · Cited by 170
Multiple Source Analysis of Interictal Spikes: Goals, Requirements, and Clinical Value
Scherg, M., Bast, T., & Berg, P. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00003 · Cited by 160
Utilization of magnetoencephalography results to obtain favourable outcomes in epilepsy surgery
Fischer, M. J. M. (2004) · Brain · doi:10.1093/brain/awh333 · Cited by 159
Epileptic Spikes: Magnetoencephalography versus Simultaneous Electrocorticography
Oishi, M., Otsubo, H., Kameyama, S., Morota, N., Masuda, H., Kitayama, M., & Tanaka, R. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.10702.x · Cited by 158
Reliability of dipole models of epileptic spikes
Merlet, I., & Gotman, J. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00062-5 · Cited by 143
EEG Source Imaging in Pediatric Epilepsy Surgery: A New Perspective in Presurgical Workup
Sperli, F., Spinelli, L., Seeck, M., Kurian, M., Michel, C. M., & Lantz, G. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00550.x · Cited by 137
EEG localization accuracy improvements using realistically shaped head models
Cuffin, B. N. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.486287 · Cited by 137
Zumsteg, D., Friedman, A., Wieser, H. G., & Wennberg, R. A. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.07.319 · Cited by 135
Magnetoencephalography in Neurosurgery
Mäkelä, J. P., Forss, N., Jääskeläinen, J. E., Kirveskari, E., Korvenoja, A., & Paetau, R. (2006) · Neurosurgery · doi:10.1227/01.neu.0000232762.63508.11 · Cited by 119
Magnetoencephalography/Magnetic Source Imaging in the Assessment of Patients with Epilepsy
Ebersole, J. S. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb04533.x · Cited by 118
Zumsteg, D., Friedman, A., Wennberg, R. A., & Wieser, H. G. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.08.009 · Cited by 117
Non-invasive localization of the epileptogenic focus by EEG dipole modeling
Ebersole, J. S. (1994) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1994.tb05179.x · Cited by 117
Does magnetoencephalography add to scalp video-EEG as a diagnostic tool in epilepsy surgery?
Pataraia, E., Simos, P. G., Castillo, E. M., Billingsley, R. L., Sarkari, S., Wheless, J. W., Maggio, V., Maggio, W., Baumgartner, J. E., Swank, P. R., et al. (2004) · Neurology · doi:10.1212/01.wnl.0000115122.81621.fe · Cited by 117
Development of Volume Conductor and Source Models to Localize Epileptic Foci
Fuchs, M., Wagner, M., & Kastner, J. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e318038fb3e · Cited by 108
Noninvasive Localization of Epileptogenic Foci by EEG Source Modeling
Ebersole, J. S. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb01531.x · Cited by 104
Spike voltage topography and equivalent dipole localization in complex partial epilepsy
Ebersole, J. S., & Wade, P. B. (1990) · Brain Topography · doi:10.1007/bf01128858 · Cited by 98
Does magnetoencephalography add to scalp video-EEG as a diagnostic tool in epilepsy surgery?
Lüders, H. O., & Iwasaki, M. (2004) · Neurology · doi:10.1212/wnl.63.10.1987 · Cited by 97
Boor, R., Jacobs, J., Hinzmann, A., Bauermann, T., Scherg, M., Boor, S., Vučurević, G., Pfleiderer, C., Kutschke, G., & Stoeter, P. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.11.272 · Cited by 90
MAGNETOENCEPHALOGRAPHY IN NEUROSURGERY
Mäkelä, J. P., Forss, N., Jääskeläinen, J. E., Kirveskari, E., Korvenoja, A., & Paetau, R. (2007) · Neurosurgery · doi:10.1227/01.neu.0000279212.23010.82 · Cited by 88
Nayak, D. S., Valentı́n, A., Alarcón, G., Seoane, J. J. G., Brunnhuber, F., Juler, J., Polkey, C. E., & Binnie, C. D. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.01.009 · Cited by 86
Continuous Source Imaging of Scalp Ictal Rhythms in Temporal Lobe Epilepsy
Assaf, B. A., & Ebersole, J. S. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb01201.x · Cited by 85
Barkley, G. L. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.12.011 · Cited by 84
Clinical Application of Dipole Models in the Localization of Epileptiform Activity
Ebersole, J. S., & Hawes‐Ebersole, S. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31803ece13 · Cited by 82
Practical considerations in the positioning of EEG electrodes
Binnie, C. D., Dekker, E., Smit, A., & Linden, G. V. D. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90010-4 · Cited by 81
Dipole localization in patients with epilepsy using the relistically shaped head model
Roth, B. J., Ko, D., von Albertini-Carletti, I., Scaffidi, D., & Sato, S. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95111-5 · Cited by 80
Merlet, I., & Gotman, J. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00458-8 · Cited by 79
Lantz, G., Menéndez, R. G. D. P., Andino, S. L. G., & Michel, C. M. (2001) · Brain Topography · doi:10.1023/a:1012996930489 · Cited by 72
An evaluation of dipole reconstruction accuracy with spherical and realistic head models in MEG
Cheylus, A., Yvert, B., Bertrand, O., & Pernier, J. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00174-1 · Cited by 70
Ictal Source Localization in Presurgical Patients With Refractory Epilepsy
Boon, P., D’Havé, M., Vanrumste, B., Hoey, G. V., Vonck, K. E. J., Walleghem, P. V., Caemaert, J., Achten, E., & Reuck, J. D. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200210000-00009 · Cited by 67
Confidence limits of dipole source reconstruction results
Fuchs, M., Wagner, M., & Kastner, J. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.01.019 · Cited by 64
Gevins, A. S. (1993) · Brain Topography · doi:10.1007/bf01128684 · Cited by 60
A Study of the Electrical Fields at the Surface of the Head
Brazier, M. A. B. (1966) · American Journal of EEG Technology · doi:10.1080/00029238.1966.11080676 · Cited by 57
Temporal Epileptogenesis: Localizing Value of Scalp and Subdural Interictal and Ictal EEG Data
Blume, W. T., Holloway, G. M., & Wiebe, S. (2001) · Epilepsia · doi:10.1046/j.1528-1157.2001.02700.x · Cited by 56
Electroencephalographic signs employed in the location of ruptured intracranial arterial aneurysms
Margerison, J. H., Binnie, C. D., & McCaul, I. R. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90166-5 · Cited by 50
Noninvasive Methods for Evaluating the Localization and Propagation of Epileptic Activity
Gotman, J. (2003) · Epilepsia · doi:10.1111/j.0013-9580.2003.12003.x · Cited by 39
Ha, K., Youn, T., Kong, S. W., Park, H.-J., Ha, T. H., Kim, M. S., & Kwon, J. S. (2003) · Brain Topography · doi:10.1023/a:1023910108759 · Cited by 26
Electric Fields and Currents in Biological Tissue
Nunez, P. L., & Srinivasan, R. (2006) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195050387.003.0004 · Cited by 11
Serullas, M. (1829) · The Philosophical Magazine · doi:10.1080/14786442908675152 · Cited by 6
Cited by
Towards the utilization of EEG as a brain imaging tool
Michel, C. M., & Murray, M. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.039 · Cited by 738
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
The standardized EEG electrode array of the IFCN
Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C., He, B., & Beniczky, S. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.254 · Cited by 489
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
“A recent comprehensive review (Plummer et al., 2008) suggests that electric source imaging deserves a place in the routine work-up of patients with localization-related epilepsy.”
BackgroundElectrophysiological Imaging of Brain Activity and Connectivity—Challenges and Opportunities
He, B., Yang, L., Wilke, C., & Yuan, H. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2139210 · Cited by 300
“Studies conducted in epilepsy centers worldwide have yielded reasonably good source detection rates of the epileptic foci, and have converged to the conclusion that EEG/MEG dipole localization would provide critical additional information for the presurgical planning in epilepsy patients [6], [17]–[19].”
Background
Metadata
- Authors
- Plummer, C., Harvey, A. S., & Cook, M.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2007-10-17
- Volume
- 49
- Issue
- 2
- Pages
- 201-218
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2082261920
- Cited by
- 252
- References
- 80
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.