The DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.
Role of ventilation in airborne transmission of infectious agents in the built environment ? a multidisciplinary systematic review
Abstract
There have been few recent studies demonstrating a definitive association between the transmission of airborne infections and the ventilation of buildings. The severe acute respiratory syndrome (SARS) epidemic in 2003 and current concerns about the risk of an avian influenza (H5N1) pandemic, have made a review of this area timely. We searched the major literature databases between 1960 and 2005, and then screened titles and abstracts, and finally selected 40 original studies based on a set of criteria. We established a review panel comprising medical and engineering experts in the fields of microbiology, medicine, epidemiology, indoor air quality, building ventilation, etc. Most panel members had experience with research into the 2003 SARS epidemic. The panel systematically assessed 40 original studies through both individual assessment and a 2-day face-to-face consensus meeting. Ten of 40 studies reviewed were considered to be conclusive with regard to the association between building ventilation and the transmission of airborne infection. There is strong and sufficient evidence to demonstrate the association between ventilation, air movements in buildings and the transmission/spread of infectious diseases such as measles, tuberculosis, chickenpox, influenza, smallpox and SARS. There is insufficient data to specify and quantify the minimum ventilation requirements in hospitals, schools, offices, homes and isolation rooms in relation to spread of infectious diseases via the airborne route. PRACTICAL IMPLICATION: The strong and sufficient evidence of the association between ventilation, the control of airflow direction in buildings, and the transmission and spread of infectious diseases supports the use of negatively pressurized isolation rooms for patients with these diseases in hospitals, in addition to the use of other engineering control methods. However, the lack of sufficient data on the specification and quantification of the minimum ventilation requirements in hospitals, schools and offices in relation to the spread of airborne infectious diseases, suggest the existence of a knowledge gap. Our study reveals a strong need for a multidisciplinary study in investigating disease outbreaks, and the impact of indoor air environments on the spread of airborne infectious diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modelling disease outbreaks in realistic urban social networks
Eubank, S., Guclu, H., Anil Kumar, V. S., Marathe, M. V., Srinivasan, A., Toroczkai, Z., & Wang, N. (2004) · Nature · doi:10.1038/nature02541 · Cited by 2,090
Zhong, N., Zheng, B., Li, Y., Poon, L., Xie, Z., Chan, K., Li, P., Tan, S., Chang, Q., Xie, J., et al. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14630-2 · Cited by 1,579
Self-citationPrinciples and Practice of Infectious Diseases
Larson, H. E. (1980) · Journal of Clinical Pathology · doi:10.1136/jcp.33.9.907-a · Cited by 1,276
Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus
Yu, I. T. S., Li, Y., Wong, T. W., Tam, W., Chan, A. T., Lee, J. H. W., Leung, D. Y. C., & Ho, T. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032867 · Cited by 1,256
Self-citationThe Sverdlovsk Anthrax Outbreak of 1979
Meselson, M., Guillemin, J., Hugh-Jones, M., Langmuir, A., Popova, I., Shelokov, A., & Yampolskaya, O. (1994) · Science · doi:10.1126/science.7973702 · Cited by 1,006
Daisey, J. M., Angell, W. J., & Apte, M. G. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00153.x · Cited by 977
AIRBORNE SPREAD OF MEASLES IN A SUBURBAN ELEMENTARY SCHOOL
RILEY, E. C., MURPHY, G., & RILEY, R. L. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112560 · Cited by 932
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876 · cited 1×
“1990; Rossi et al., 1991; Seppanen et al., 1999; Sundell, 2004; Wargocki et al., 2002), particularly concerning building-related illnesses (Kroenke, 1998; Menzies and Bourbeau, 1997) or sick building syndrome (Kreiss, 1990; Redlich et al., 1997; Sherin, 1993), little is known about the impact of…”
BackgroundEdlin, B. R., Tokars, J. I., Grieco, M. H., Crawford, J. T., Williams, J., Sordillo, E. M., Ong, K. R., Kilburn, J. O., Dooley, S. W., Castro, K. G., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199206043262302 · Cited by 861
De, N., Rs, K., Rl, L., Chrismon, J. H., Merritt, R., Da, A., & Giovino, G. A. (1994) · PubMed · Cited by 797
Redlich, C. A., Sparer, J., & Cullen, M. R. (1997) · The Lancet · doi:10.1016/s0140-6736(96)07220-0 · Cited by 759
Building ventilation: theory and measurement
(1997) · Choice Reviews Online · doi:10.5860/choice.35-2135 · Cited by 734
Transmission of the Severe Acute Respiratory Syndrome on Aircraft
Olsen, S. J., Chang, H.-L., Cheung, T. Y.-Y., Tang, A. F.-Y., Fisk, T. L., Ooi, S. P.-L., Kuo, H.-W., Jiang, D. D.-S., Chen, K.-T., Lando, J., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031349 · Cited by 719
Social and environmental risk factors in the emergence of infectious diseases
Weiss, R. A., & McMichael, A. J. (2004) · Nature Medicine · doi:10.1038/nm1150 · Cited by 704
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
On the history of indoor air quality and health
Sundell, J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00273.x · Cited by 613
Self-citationAN OUTBREAK OF INFLUENZA ABOARD A COMMERCIAL AIRLINER
MOSER, M. R., BENDER, T. R., MARGOLIS, H. S., NOBLE, G. R., KENDAL, A. P., & RITTER, D. G. (1979) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112781 · Cited by 605
WELLS, W. F. (1934) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a118097 · Cited by 602
Estimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 549
Transmission of infectious diseases during commercial air travel
Mangili, A., & Gendreau, M. A. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71089-8 · Cited by 535
Indirect health effects of relative humidity in indoor environments.
Arundel, A. V., Sterling, E. M., Biggin, J. H., & Sterling, T. D. (1986) · Environmental Health Perspectives · doi:10.1289/ehp.8665351 · Cited by 525
Booth, T. F., Kournikakis, B., Bastien, N., Ho, J., Kobasa, D., Stadnyk, L., Li, Y., Spence, M., Paton, S., Henry, B., et al. (2005) · The Journal of Infectious Diseases · doi:10.1086/429634 · Cited by 425
Self-citationWargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Self-citationRole of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong
Li, Y., Huang, X., Yu, I. T. S., Wong, T. W., & Qian, H. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00317.x · Cited by 414
Self-citationTransmission of Multidrug-Resistant Mycobacterium tuberculosis during a Long Airplane Flight
Kenyon, T. A., Valway, S. E., Ihle, W. W., Onorato, I. M., & Castro, K. G. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604113341501 · Cited by 357
Impact of air filtration on nosocomial aspergillus infections
Sherertz, R. J., Belani, A., Kramer, B. S., Elfenbein, G. J., Weiner, R. S., Sullivan, M. L., Thomas, R. G., & Samsa, G. P. (1987) · The American Journal of Medicine · doi:10.1016/0002-9343(87)90902-8 · Cited by 333
Cough-generated Aerosols of Mycobacterium tuberculosis: A New Method to Study Infectiousness
Fennelly, K. P., Martyny, J. W., Fulton, K. E., Orme, I. M., Cave, D. M., & Heifets, L. B. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200308-1101oc · Cited by 327
Cole, E. C., & Cook, C. E. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70046-x · Cited by 317
Riley, R. L., MILLS, C. C., O'Grady, F., SULTAN, L. U., Wittstadt, F. B., & Shivpuri, D. (1962) · PubMed · doi:10.1164/arrd.1962.85.4.511 · Cited by 313
An Epidemic of Pneumococcal Disease in an Overcrowded, Inadequately Ventilated Jail
Hoge, C. W., Reichler, M. R., Dominguez, E. A., Bremer, J. C., Mastro, T. D., Hendricks, K. A., Musher, D. M., Elliott, J. A., Facklam, R. R., & Breiman, R. F. (1994) · New England Journal of Medicine · doi:10.1056/nejm199409083311004 · Cited by 271
Cluster of SARS among Medical Students Exposed to Single Patient, Hong Kong
Wong, T.-W., Lee, C.-K., Tam, W., Lau, J. T.-F., Yu, T.-S., Lui, S.-F., Chan, P. K. S., Li, Y., Bresee, J. S., Sung, J. J. Y., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030452 · Cited by 265
Self-citationAirborne Transmission of Chickenpox in a Hospital
Leclair, J. M., Zaia, J. A., Levin, M. J., Congdon, R. G., & Goldmann, D. A. (1980) · New England Journal of Medicine · doi:10.1056/nejm198002213020807 · Cited by 263
Airborne Infection: Theoretical Limits of Protection Achievable by Building Ventilation
Nardell, E. A., Keegan, J., Cheney, S. A., & Etkind, S. C. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.2.302 · Cited by 261
Survival Characteristics of Airborne Human Coronavirus 229E
Ijaz, M. K., Brunner, A. H., Sattar, S. A., Nair, R. C., & Johnson-Lussenburg, C. M. (1985) · Journal of General Virology · doi:10.1099/0022-1317-66-12-2743 · Cited by 254
Nosocomial transmission of tuberculosis in a hospital unit for HIV-infected patients
Sw, D. (1992) · JAMA · doi:10.1001/jama.267.19.2632 · Cited by 253
Measles Outbreak in a Pediatric Practice: Airborne Transmission in an Office Setting
Bloch, A. B., Orenstein, W. A., Ewing, W. M., Spain, W. H., Mallison, G. F., Herrmann, K. L., & Hinman, A. R. (1985) · Pediatrics · doi:10.1542/peds.75.4.676 · Cited by 237
The Airborne Transmission of Infection in Hospital Buildings: Fact or Fiction?
Beggs, C. B. (2003) · Indoor and Built Environment · doi:10.1177/1420326x03012001002 · Cited by 220
Infectious Disease Outbreaks in Nursing Homes: An Unappreciated Hazard for Frail Elderly Persons
Strausbaugh, L. J., Sukumar, S. R., & Joseph, C. L. (2003) · Clinical Infectious Diseases · doi:10.1086/368197 · Cited by 218
Wehrle, P. F., Posch, J. L., Richter, K. H., et al. (1970) · PubMed · Cited by 212
Hospital Ventilation and Risk for Tuberculous Infection in Canadian Health Care Workers
Menzies, D., Fanning, A., Yuan, L., FitzGerald, J. M., & and the Canadian Collaborative Group in Nosocomial Transmission of TB* (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-10-200011210-00010 · Cited by 212
Coronado, V. G., Beck-Sague, C. M., Hutton, M. D., Davis, B. J., Nicholas, P., Villareal, C., Woodley, C. L., Kilburn, J. O., Crawford, J. T., Frieden, T. R., et al. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/168.4.1052 · Cited by 200
Transmission of viral respiratory infections in the home
GOLDMANN, D. A. (2000) · The Pediatric Infectious Disease Journal · doi:10.1097/00006454-200010001-00002 · Cited by 196
Li, Y., Duan, S., Yu, I. T. S., & Wong, T. W. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00318.x · Cited by 194
Self-citationThe Epidemiology of Tuberculosis Infection in a Closed Environment
Houk, V. N., Baker, J. H., Sorensen, K., & Kent, D. C. (1968) · Archives of Environmental Health: An International Journal · doi:10.1080/00039896.1968.10665011 · Cited by 190
Nosocomial Spread of Viral Disease
Aitken, C., & Jeffries, D. J. (2001) · Clinical Microbiology Reviews · doi:10.1128/cmr.14.3.528-546.2001 · Cited by 189
An Outbreak of Airborne Nosocomial Varicella
Gustafson, T. L., Lavely, G. B., Brawner, E. R., Hutcheson, R. H., Wright, P. F., & Schaffner, W. (1982) · Pediatrics · doi:10.1542/peds.70.4.550 · Cited by 185
The Aerobiological Pathway of Microorganisms
Cox, C. S. (1988) · 1988 · doi:10.1515/9783112581803-016 · Cited by 181
Menzies, D., & Bourbeau, J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199711203372107 · Cited by 167
Nosocomial Transmission of Tuberculosis Associated with a Draining Abscess
Hutton, M. D., Stead, W. W., Cauthen, G. M., Bloch, A. B., & Ewing, W. M. (1990) · Journal of Infectious Diseases · doi:10.1093/infdis/161.2.286 · Cited by 163
Tuberculosis Outbreak in a General Hospital: Evidence for Airborne Spread of Infection
Ehrenkranz, N. J., & KICKLIGHTER, J. L. (1972) · Annals of Internal Medicine · doi:10.7326/0003-4819-77-3-377 · Cited by 162
Detection of Airborne Rhinovirus and Its Relation to Outdoor Air Supply in Office Environments
Myatt, T. A., Johnston, S. L., Zuo, Z., Wand, M., Kebadze, T., Rudnick, S., & Milton, D. K. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-760oc · Cited by 161
Airborne Transmission of Measles in a Physician's Office
Remington, P. (1985) · JAMA · doi:10.1001/jama.1985.03350350068022 · Cited by 149
Molecular epidemiology of the novel coronavirus that causes severe acute respiratory syndrome
Guan, Y., Peiris, J., Zheng, B., Poon, L. L. M., Chan, K., Zeng, F., Chan, C. W. M., Chan, M., Chen, J. D., Chow, K., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(03)15259-2 · Cited by 144
Temporal-Spatial Analysis of Severe Acute Respiratory Syndrome among Hospital Inpatients
Yu, I. T. S., Wong, T. W., Chiu, Y. L., Lee, N. L. S., & Li, Y. (2005) · Clinical Infectious Diseases · doi:10.1086/428735 · Cited by 128
Self-citationAirborne infection : transmission and control
Riley, R. L., & O'Grady, F. (1961) · University of Michigan Library Repository · Cited by 123
Airborne Transmission of Influenza Virus Infection in Mice
Schulman, J. L., & Kilbourne, E. D. (1962) · Nature · doi:10.1038/1951129a0 · Cited by 119
Tang, J. W.-T., Eames, I., Li, Y., Taha, Y., Wilson, P., Bellingan, G. J., Ward, K. N., & Breuer, J. (2005) · Journal of Hospital Infection · doi:10.1016/j.jhin.2005.05.017 · Cited by 113
Self-citation-, D. K., Haji, T. C., Keer, V., Hawkey, P. M., Duncanson, V., & Flower, E. (1998) · Journal of Hospital Infection · doi:10.1016/s0195-6701(98)90326-7 · Cited by 111
The numbers and the sites of origin of the droplets expelled during expiratory activities.
Jp, D. (1945) · PubMed Central · Cited by 106
Lack of SARS Transmission among Public Hospital Workers, Vietnam
Hà, L. D., Bloom, S. A., Hien, N. Q., Maloney, S. A., Quynh, L. T., Leitmeyer, K. C., Anh, B. H., Reynolds, M. G., Montgomery, J. M., Comer, J. A., et al. (2004) · Emerging infectious diseases · doi:10.3201/eid1002.030707 · Cited by 105
Aircraft Cabin Air Recirculation and Symptoms of the Common Cold
Zitter, J. (2002) · JAMA · doi:10.1001/jama.288.4.483 · Cited by 93
Elender, F., Bentham, G., & Langford, I. H. (1998) · Social Science & Medicine · doi:10.1016/s0277-9536(97)00178-0 · Cited by 85
Report of an outbreak: nursing home architecture and influenza-A attack rates
Drinka, P. J., Krause, P., Schilling, M., Miller, B. A., Shult, P., & Gravenstein, S. (1996) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1996.tb01859.x · Cited by 77
The Relative Efficacy of Respirators and Room Ventilation in Preventing Occupational Tuberculosis
Fennelly, K. P., & Nardell, E. A. (1998) · Infection Control and Hospital Epidemiology · doi:10.1086/647719 · Cited by 76
Fraser, V. J., Johnson, K. M., Primack, J., Jones, M., Medoff, G., & Dunagan, W. C. (1993) · Infection Control and Hospital Epidemiology · doi:10.1086/646654 · Cited by 74
Airborne Infection withBacillus anthracis—from Mills to Mail
Fennelly, K. P., Davidow, A. L., Miller, S. L., et al. (2004) · Emerging infectious diseases · doi:10.3201/eid1006.020738 · Cited by 73
Langmuir, A. D. (1980) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1980.tb18903.x · Cited by 68
Myatt, T. A., Johnston, S. L., Rudnick, S. N., & Milton, D. K. (2003) · BMC Public Health · doi:10.1186/1471-2458-3-5 · Cited by 68
PART I. KEYNOTE ADDRESS: EPIDEMIOLOGY OF AIRBORNE INFECTION
Langmuir, A. D. (1961) · Bacteriological Reviews · doi:10.1128/br.25.3.173-181.1961 · Cited by 61
Airborne Contagion and Air Hygiene: An Ecological Study of Droplet Infection
(1957) · Tubercle · doi:10.1016/s0041-3879(57)80076-2 · Cited by 58
The Investigation of a Tuberculosis Outbreak in the Closed Environment of a U.S. Navy Ship, 1987
DiStasio, A. J., & Trump, D. H. (1990) · Military Medicine · doi:10.1093/milmed/155.8.347 · Cited by 55
Cotterill, S., Evans, R., & Fraise, A. P. (1996) · Journal of Hospital Infection · doi:10.1016/s0195-6701(96)90147-4 · Cited by 51
Mastorides, S., Oehler, R. L., Greene, J. N., Sinnott, J. T., Kranik, M., & Sandin, R. L. (1999) · CHEST Journal · doi:10.1378/chest.115.1.19 · Cited by 51
An Evaluation of Hospital Special-Ventilation-Room Pressures
Rice, N., Streifel, A. J., & Vesley, D. (2001) · Infection Control and Hospital Epidemiology · doi:10.1086/501819 · Cited by 47
Rutala, W. A., Jones, S. M., Worthington, J., et al. (1995) · Infection Control and Hospital Epidemiology · doi:10.1086/647136 · Cited by 46
Wan, G., Lu, S.-C., & Tsai, Y.-H. (2004) · American Journal of Infection Control · doi:10.1016/s0196-6553(03)00090-7 · Cited by 36
Institutional Control Measures for Tuberculosis in the Era of Multiple Drug Resistance
Bates, J. H., & Nardell, E. A. (1995) · CHEST Journal · doi:10.1378/chest.108.6.1690 · Cited by 36
Commissioning operating theatres
Holton, J., & Ridgway, G. L. (1993) · Journal of Hospital Infection · doi:10.1016/0195-6701(93)90019-v · Cited by 32
Detection of Mycobacterium tuberculosis complex by PCR in hospital air samples
Vadrot, C., Bex, V., Mouilleseaux, A., Squinazi, F., & Darbord, J. C. (2004) · Journal of Hospital Infection · doi:10.1016/j.jhin.2004.04.026 · Cited by 30
Delays in the Application of Outbreak Control Prophylaxis for Influenza a in a Nursing Home
Drinka, P. J., Krause, P. F., Nest, L. J., Gravenstein, S., Goodman, B., & Shult, P. A. (2002) · Infection Control and Hospital Epidemiology · doi:10.1086/501978 · Cited by 25
Johanning, E., Auger, P. L., & Reijula, K. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804093381514 · Cited by 18
Report of an Outbreak: Nursing Home Architecture and Influenza‐A Attack Rates: Update
Drinka, P. J., Krause, P. F., Nest, L. J., & Tyndall, D. (2004) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2004.52230_6.x · Cited by 14
Indoor infection in a modern building.
SHIGEMATSU, I., & Minowa, M. (1985) · PubMed · Cited by 9
Detection of AirborneMycobacterium tuberculosisby Air Filtration and Polymerase Chain Reaction
Mastorides, S., Oehler, R. L., Greene, J. N., Sinnott, J. T., & Sandin, R. L. (1997) · Clinical Infectious Diseases · doi:10.1086/516953 · Cited by 6
Human health and air conditioning systems.
Rossi, G., Corsico, A. G., Roggeri, A., & Moscato, G. (1991) · PubMed · Cited by 5
Cited by
Airborne transmission of respiratory viruses
Wang, C. C., Prather, K. A., Sznitman, J., Jimenez, J. L., Lakdawala, S. S., Tufekci, Z., & Marr, L. C. (2021) · Science · doi:10.1126/science.abd9149 · Cited by 1,543
A Review of the Research Literature on Evidence-Based Healthcare Design
Ulrich, R. S., Zimring, C., Zhu, X., DuBose, J., Seo, H.-B., Choi, Y.-S., Quan, X., & Joseph, A. (2008) · HERD: Health Environments Research & Design Journal · doi:10.1177/193758670800100306 · Cited by 1,421
How can airborne transmission of COVID-19 indoors be minimised?
Morawska, L., Tang, J. W., Bahnfleth, W., Bluyssen, P. M., Boerstra, A., Buonanno, G., Cao, J., Dancer, S., Floto, A., Franchimon, F., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105832 · Cited by 1,343
Self-citationTransmissibility and transmission of respiratory viruses
Leung, N. H. L. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-021-00535-6 · Cited by 890
Recognition of aerosol transmission of infectious agents: a commentary
Tellier, R., Li, Y., Cowling, B. J., & Tang, J. W. (2019) · BMC Infectious Diseases · doi:10.1186/s12879-019-3707-y · Cited by 746
Self-citation
Metadata
- Authors
- Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., Sleigh, A. C., Su, H.-J. J., Sundell, J., Wong, T. W., & Yuen, P. L.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2007-02
- Volume
- 17
- Issue
- 1
- Pages
- 2-18
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2158731622
- Cited by
- 1,055
- References
- 85
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.