Microneedles: an emerging transdermal drug delivery system
The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Abstract
Objectives: One of the thrust areas in drug delivery research is transdermal drug delivery systems (TDDS) due to their characteristic advantages over oral and parenteral drug delivery systems. Researchers have focused their attention on the use of microneedles to overcome the barrier of the stratum corneum. Microneedles deliver the drug into the epidermis without disruption of nerve endings. Recent advances in the development of microneedles are discussed in this review for the benefit of young scientists and to promote research in the area. Key findings: Microneedles are fabricated using a microelectromechanical system employing silicon, metals, polymers or polysaccharides. Solid coated microneedles can be used to pierce the superficial skin layer followed by delivery of the drug. Advances in microneedle research led to development of dissolvable/degradable and hollow microneedles to deliver drugs at a higher dose and to engineer drug release. Iontophoresis, sonophoresis and electrophoresis can be used to modify drug delivery when used in concern with hollow microneedles. Microneedles can be used to deliver macromolecules such as insulin, growth hormones, immunobiologicals, proteins and peptides. Microneedles containing ‘cosmeceuticals’ are currently available to treat acne, pigmentation, scars and wrinkles, as well as for skin tone improvement. Summary: Literature survey and patents filled revealed that microneedle-based drug delivery system can be explored as a potential tool for the delivery of a variety of macromolecules that are not effectively delivered by conventional transdermal techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Current status and future potential of transdermal drug delivery
Prausnitz, M. R., Mitragotri, S., & Langer, R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1304 · Cited by 1,462
Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.002 · Cited by 1,026
Dissolving microneedles for transdermal drug delivery
Lee, J. W., Park, J.-H., & Prausnitz, M. R. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.048 · Cited by 968
Dissolving polymer microneedle patches for influenza vaccination
Sullivan, S. P., Koutsonanos, D. G., del Pilar Martin, M., Lee, J. W., Zarnitsyn, V., Choi, S.-O., Murthy, N., Compans, R. W., Skountzou, I., & Prausnitz, M. R. (2010) · Nature Medicine · doi:10.1038/nm.2182 · Cited by 948
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
Coated microneedles for transdermal delivery
Gill, H. S., & Prausnitz, M. R. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.017 · Cited by 765
Transdermal drug delivery: overcoming the skin’s barrier function
Naik, A., Kalia, Y. N., & Guy, R. H. (2000) · Pharmaceutical Science & Technology Today · doi:10.1016/s1461-5347(00)00295-9 · Cited by 720
Effect of Microneedle Design on Pain in Human Volunteers
Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R. (2008) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31816778f9 · Cited by 701
Transdermal skin delivery: Predictions for humans from in vivo, ex vivo and animal models☆
GODIN, B., & TOUITOU, E. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.07.004 · Cited by 675
Langer, R. (2001) · Science · doi:10.1126/science.1063273 · Cited by 579
Lack of Pain Associated with Microfabricated Microneedles
Kaushik, S., Hord, A. H., Denson, D. D., McAllister, D. V., Smitra, S., Allen, M. G., & Prausnitz, M. R. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200102000-00041 · Cited by 576
Transdermal Delivery of Insulin Using Microneedles in Vivo
Martanto, W., Davis, S. P., Holiday, N. R., Wang, J., Gill, H. S., & Prausnitz, M. R. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000029282.44140.2e · Cited by 521
Polymer Microneedles for Controlled-Release Drug Delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-0028-9 · Cited by 493
Micro-scale devices for transdermal drug delivery
Arora, A., Prausnitz, M. R., & Mitragotri, S. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.08.032 · Cited by 464
Donnelly, R. F., Majithiya, R., Singh, T. R. R., Morrow, D. I. J., Garland, M. J., Demir, Y. K., Migalska, K., Ryan, E., Gillen, D., Scott, C. J., et al. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0169-8 · Cited by 417
Enhancement of transdermal drug delivery via synergistic action of chemicals
Karande, P., & Mitragotri, S. (2009) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2009.08.015 · Cited by 399
Transdermal delivery of desmopressin using a coated microneedle array patch system
Cormier, M., Johnson, B. L., Ameri, M., Nyam, K., LIBIRAN, L., Zhang, D. D., & Daddona, P. E. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.04.003 · Cited by 388
Matriano, J. A., Cormier, M., Johnson, J., Young, W. A., Buttery, M., Nyam, K., & Daddona, P. E. (2002) · Pharmaceutical Research · doi:10.1023/a:1013607400040 · Cited by 373
Kinetics of skin resealing after insertion of microneedles in human subjects
Gupta, J., Gill, H. S., Andrews, S. N., & Prausnitz, M. R. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.05.021 · Cited by 342
Microneedle array for transdermal biological fluid extraction and in situ analysis
Mukerjee, E. V., Collins, S. D., Isseroff, R. R., & Smith, R. L. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.11.008 · Cited by 340
Microfabricated Microneedles for Gene and Drug Delivery
McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.289 · Cited by 335
Van Damme, P., Oosterhuis-Kafeja, F., Van der Wielen, M., Almagor, Y., Sharon, O., & Levin, Y. (2009) · Vaccine · doi:10.1016/j.vaccine.2008.10.077 · Cited by 331
Clinical administration of microneedles: skin puncture, pain and sensation
Haq, M. I., Smith, E., John, D. N., Kalavala, M., Edwards, C., Anstey, A., Morrissey, A., & Birchall, J. C. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9208-1 · Cited by 329
Coating Formulations for Microneedles
Gill, H. S., & Prausnitz, M. R. (2007) · Pharmaceutical Research · doi:10.1007/s11095-007-9286-4 · Cited by 318
In vivo assessment of safety of microneedle arrays in human skin
Bal, S. M., Caussin, J., Pavel, S., & Bouwstra, J. A. (2008) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.06.016 · Cited by 303
Intradermal vaccine delivery: Will new delivery systems transform vaccine administration?
Lambert, P. H., & Laurent, P. E. (2008) · Vaccine · doi:10.1016/j.vaccine.2008.03.095 · Cited by 302
Coated Microneedles for Drug Delivery to the Eye
Jiang, J., Gill, H. S., Ghate, D., McCarey, B. E., Patel, S. R., Edelhauser, H. F., & Prausnitz, M. R. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0066 · Cited by 286
Badran, M. M., Kuntsche, J., & Fahr, A. (2009) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.12.008 · Cited by 276
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267
Chu, L. Y., Choi, S.-O., & Prausnitz, M. R. (2010) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22140 · Cited by 259
Kim, Y.-C., Quan, F.-S., Compans, R. W., Kang, S.-M., & Prausnitz, M. R. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.10.013 · Cited by 255
Thomas, B. J., & Finnin, B. C. (2004) · Drug Discovery Today · doi:10.1016/s1359-6446(04)03180-0 · Cited by 245
Daddona, P. E., Matriano, J. A., Mandema, J., & Maa, Y.-F. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0192-9 · Cited by 234
Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro
Donnelly, R. F., Singh, T. R. R., Tunney, M. M., Morrow, D. I. J., McCarron, P. A., O’Mahony, C., & Woolfson, A. D. (2009) · Pharmaceutical Research · doi:10.1007/s11095-009-9967-2 · Cited by 227
Verbaan, F. J., Bal, S. M., van den Berg, D. J., Groenink, W. H. H., Verpoorten, H., Lüttge, R., & Bouwstra, J. A. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.11.009 · Cited by 227
Super-short solid silicon microneedles for transdermal drug delivery applications
Wei-Ze, L., Mei-Rong, H., Jian-Ping, Z., Yong-Qiang, Z., Bao-Hua, H., Ting, L., & Yong, Z. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.01.024 · Cited by 217
WIDERA, G., JOHNSON, J., KIM, L., LIBIRAN, L., NYAM, K., DADDONA, P., & CORMIER, M. (2006) · Vaccine · doi:10.1016/j.vaccine.2005.09.049 · Cited by 208
In vitro transdermal delivery of therapeutic antibodies using maltose microneedles
Li, G., Badkar, A., Nema, S., Kolli, C. S., & Banga, A. K. (2009) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.10.008 · Cited by 205
Chen, H., Zhu, H., Zheng, J., Mou, D., Wan, J., Zhang, J., Shi, T., Zhao, Y., Xu, H., & Yang, X. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.05.031 · Cited by 202
Shawgo, R. S., Richards Grayson, A. C., Li, Y., & Cima, M. J. (2002) · Current Opinion in Solid State and Materials Science · doi:10.1016/s1359-0286(02)00032-3 · Cited by 185
Donnelly, R. F., Morrow, D. I. J., McCarron, P. A., Woolfson, A. D., Morrissey, A., Juzenas, P., Juzeniene, A., Iani, V., McCarthy, H. O., & Moan, J. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.05.002 · Cited by 173
Two-Layered Dissolving Microneedles for Percutaneous Delivery of Peptide/Protein Drugs in Rats
Fukushima, K., Ise, A., Morita, H., Hasegawa, R., Ito, Y., Sugioka, N., & Takada, K. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0097-7 · Cited by 171
Clinical microneedle injection of methyl nicotinate: stratum corneum penetration
Sivamani, R. K., Stoeber, B., Wu, G. C., Zhai, H., Liepmann, D., & Maibach, H. (2005) · Skin Research and Technology · doi:10.1111/j.1600-0846.2005.00107.x · Cited by 171
A microneedle roller for transdermal drug delivery
Park, J.-H., Choi, S.-O., Seo, S., Choy, Y. B., & Prausnitz, M. R. (2010) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2010.07.001 · Cited by 166
Qiu, Y., Gao, Y., Hu, K., & Li, F. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.04.019 · Cited by 160
Processing difficulties and instability of carbohydrate microneedle arrays
Donnelly, R. F., Morrow, D. I. J., Singh, T. R. R., Migalska, K., McCarron, P. A., O'Mahony, C., & Woolfson, A. D. (2009) · Drug Development and Industrial Pharmacy · doi:10.1080/03639040902882280 · Cited by 159
A passive MEMS drug delivery pump for treatment of ocular diseases
Lo, R., Li, P.-Y., Saati, S., Agrawal, R. N., Humayun, M. S., & Meng, E. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9313-9 · Cited by 158
Microneedle arrays for the transcutaneous immunization of diphtheria and influenza in BALB/c mice
Ding, Z., Verbaan, F. J., Bivas‐Benita, M., Bungener, L. B., Huckriede, A. L. W., van den Berg, D., Kersten, G. F. A., & Bouwstra, J. A. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.01.025 · Cited by 155
Self-dissolving microneedles for the percutaneous absorption of EPO in mice
Ιtο, Y., Yoshimitsu, J., Shiroyama, K., Sugioka, N., & Takada, K. (2006) · Journal of drug targeting · doi:10.1080/10611860600785080 · Cited by 151
Controlled transdermal delivery of model drug compounds by MEMS microneedle array
Xie, Y., Xu, B., & Gao, Y. (2005) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2005.03.001 · Cited by 146
Geometrical effects in mechanical characterizing of microneedle for biomedical applications
Aggarwal, P., & Johnston, C. R. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.04.024 · Cited by 138
OH, J., PARK, H., Do, K., Han, M. S., Hyun, D.-H., Kim, C.-G., Kim, C.-G., Lee, S., Hwang, S., & Shin, S. H. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.02.009 · Cited by 138
Rapid Intradermal Delivery of Liquid Formulations Using a Hollow Microstructured Array
Burton, S. A., Ng, C.-Y., Simmers, R., Moeckly, C., Brandwein, D., Gilbert, T., Johnson, N., Brown, K., Alston, T., Prochnow, G., et al. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0177-8 · Cited by 130
In-plane single-crystal-silicon microneedles for minimally invasive microfluid systems
Paik, S., Byun, S., Lim, J.-M., Park, Y., Lee, A., Chung, S. H., Chang, J., Chun, K., & Cho, D. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2003.12.029 · Cited by 129
In Vitro and In Vivo Characterization of MEMS Microneedles
Teo, M. A. L., Shearwood, C., Ng, K. C., Lu, J., & Moochhala, S. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-6171-y · Cited by 128
Microneedle Insertion Force Reduction Using Vibratory Actuation
Yang, M., & Zahn, J. D. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000042046.07678.2e · Cited by 128
Dean, C. H., Alarcon, J. B., Waterston, A. M., Draper, K., EARLY, R. J., Guirakhoo, F., Monath, T. P. C., & Mikszta, J. A. (2005) · Human Vaccines · doi:10.4161/hv.1.3.1797 · Cited by 121
Fabrication of a micro needle for a trace blood test
Oka, K., Aoyagi, S., Arai, Y., Isono, Y., Hashiguchi, G., & Fujita, H. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(01)00872-x · Cited by 117
Transdermal microneedles for drug delivery applications
Teo, A. L., Shearwood, C., Ng, K. C., Lu, J., & Moochhala, S. (2006) · Materials Science and Engineering B · doi:10.1016/j.mseb.2006.02.008 · Cited by 116
Silicon microneedle electrode array with temperature monitoring for electroporation
Wilke, N., Hibert, C., O’Brien, J., & Morrissey, A. (2005) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2005.05.017 · Cited by 113
Chen, B., Wei, J., & Iliescu, C. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.11.013 · Cited by 113
Laurent, P. E., Bourhy, H., Fantino, M., Alchas, P., & Mikszta, J. A. (2010) · Vaccine · doi:10.1016/j.vaccine.2010.06.062 · Cited by 101
The Use of Silicon Microfabrication Technology in Painless Blood Glucose Monitoring
Smart, W. H., & Subramanian, K. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050501961 · Cited by 101
Stability Kinetics of Influenza Vaccine Coated onto Microneedles During Drying and Storage
Kim, Y., Quan, F., Compans, R. W., Kang, S., & Prausnitz, M. R. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0134-6 · Cited by 96
Bal, S. M., Slütter, B., van Riet, E., Kruithof, A. C., Ding, Z., Kersten, G. F. A., Jiskoot, W., & Bouwstra, J. A. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.11.018 · Cited by 96
Microneedle Arrays Permit Enhanced Intradermal Delivery of a Preformed Photosensitizer
Donnelly, R. F., Morrow, D. I. J., McCarron, P. A., Woolfson, A. D., Morrissey, A., Juzenas, P., Juzeniene, A., Iani, V., McCarthy, H. O., & Moan, J. E. (2008) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.2008.00417.x · Cited by 91
Microfabricated microneedle with porous tip for drug delivery
Ji, J., Tay, F. E. H., Miao, J., & Iliescu, C. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/012 · Cited by 81
Ashraf, M. W., Tayyaba, S., Nisar, A., Afzulpurkar, N., Bodhale, D. W., Lomas, T., Poyai, A., & Tuantranont, A. (2010) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-010-9100-5 · Cited by 80
Continuous On-Chip Micropumping for Microneedle Enhanced Drug Delivery
Zahn, J. D., Deshmukh, A. A., Pisano, A. P., & Liepmann, D. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000042047.83433.96 · Cited by 78
Current aspects of formulation efforts and pore lifetime related to microneedle treatment of skin
Milewski, M., Brogden, N. K., & Stinchcomb, A. L. (2010) · Expert Opinion on Drug Delivery · doi:10.1517/17425241003663228 · Cited by 78
Jin, C. Y., Han, M. H., Lee, S. E., & Choi, Y. H. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9337-1 · Cited by 76
Wang, P.-C., Wester, B. A., Rajaraman, S., Paik, S., Kim, S.-H., & Allen, M. G. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333317 · Cited by 74
In vivovisualization of microneedle conduits in human skin using laser scanning microscopy
Bal, S. M., Kruithof, A. C., Liebl, H., Tomerius, M., Bouwstra, J. A., Lademann, J. M., & Meinke, M. C. (2010) · Laser Physics Letters · doi:10.1002/lapl.200910134 · Cited by 67
Transdermal drug delivery by in-skin electroporation using a microneedle array
Yan, K., Todo, H., & Sugibayashi, K. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.06.052 · Cited by 66
In vivo evaluation of a microneedle-based miniature syringe for intradermal drug delivery
Häfeli, U. O., Mokhtari, A. M., Liepmann, D., & Stoeber, B. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9311-y · Cited by 64
Morefield, G. L., Tammariello, R. F., Purcell, B. K., Worsham, P. L., Chapman, J. L., Smith, L. A., Alarcon, J. B., Mikszta, J. A., & Ulrich, R. G. (2008) · Journal of Immune Based Therapies and Vaccines · doi:10.1186/1476-8518-6-5 · Cited by 61
In vitro permeation of a pegylated naltrexone prodrug across microneedle-treated skin
Milewski, M., Reddy, Y. T., Ghosh, P., Crooks, P. A., & Stinchcomb, A. L. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.05.034 · Cited by 54
Wu, X., Todo, H., & Sugibayashi, K. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2006.02.046 · Cited by 54
Effect of microneedle on the pharmacokinetics of ketoprofen from its transdermal formulations
So, J.-W., Park, H.-H., Lee, S. E., Kim, D., Shin, S., & Cho, C. (2009) · Drug Delivery · doi:10.1080/10717540802518082 · Cited by 47
Andrianov, A. K., Marin, A., & DeCollibus, D. P. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0133-7 · Cited by 45
Bioneedles as alternative delivery system for hepatitis B vaccine
Hirschberg, H. J. H. B., van de Wijdeven, G. G. P., Kraan, H., Amorij, J., & Kersten, G. F. A. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.06.028 · Cited by 41
Bioneedles™ as vaccine carriers
Hirschberg, H. J. H. B., van de Wijdeven, G. G. P., Kelder, A. B., van den Dobbelsteen, G. P. J. M., & Kersten, G. F. A. (2008) · Vaccine · doi:10.1016/j.vaccine.2008.02.067 · Cited by 34
You, S.-K., Noh, Y., Park, H.-H., Han, M., Lee, S. E., Shin, S., & Cho, C. (2009) · Journal of drug targeting · doi:10.3109/10611860903115274 · Cited by 31
Opportunities and challenges in vaccine delivery
Carstens, M. G. (2008) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.11.004 · Cited by 19
Zhang, S., Qin, G., Wu, Y., Gao, Y., Qiu, Y., Li, F., & Bai, X. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0109-7 · Cited by 17
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Alkilani, A., McCrudden, M. T., & Donnelly, R. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7040438 · Cited by 1,147
Recent advances in transdermal drug delivery systems: a review
Jeong, W. Y., Kwon, M., Choi, H. E., & Kim, K. S. (2021) · Biomaterials Research · doi:10.1186/s40824-021-00226-6 · Cited by 593
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Aldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Metadata
- Authors
- Bariya, S. H., Gohel, M. C., Mehta, T. A., & Sharma, O. P.
- Venue
- Journal of Pharmacy and Pharmacology
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-01-01
- Volume
- 64
- Issue
- 1
- Pages
- 11-29
- ISSN
- 0022-3573 (ISSN-L)
- 2042-7158
- OpenAlex
- W1573570351
- Cited by
- 455
- References
- 87
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.