Corneal biomechanics – a review
Open accessThe DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
Purpose: In recent years, the interest in corneal biomechanics has strongly increased. The material properties of the cornea determine its shape and therefore play an important role in corneal ectasia and related pathologies. This review addresses the molecular origin of biomechanical properties, models for their description, methods for their characterisation, techniques for their modification, and computational simulation approaches. Recent findings: Recent research has focused on developing non‐contact techniques to measure the biomechanical properties in vivo , on determining structural and molecular abnormalities in pathological corneas, on developing and optimising techniques to reinforce the corneal tissue and on the computational simulation of surgical interventions. Summary: A better understanding of corneal biomechanics will help to improve current refractive surgeries, allow an earlier diagnosis of ectatic disorders and a better quantification of treatments aiming at reinforcing the corneal tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
Luce, D. A. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.10.044 · Cited by 1,311 · cited 1×
“The ocular response analyser 67 was the first device that tried to related the dynamic deformation response of the cornea with biomechanical parameters.”
TENDON INJURY AND TENDINOPATHY: HEALING AND REPAIR
SHARMA, P., & MAFFULLI, N. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200501000-00030 · Cited by 1,074
Wollensak, G., Spoerl, E., & Seiler, T. (2003) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(03)00407-3 · Cited by 1,024 · cited 1×
“For elastic testing, a slowly increasing load is applied (stress-strain diagram).(49) For viscoelastic testing, a one-step load is applied and maintained constant until the end of the test (stress-relaxation test), or a one-step dis placement is applied and maintained constant (creep test).”
Induction of Cross-links in Corneal Tissue
Spoerl, E., Huhle, M., & Seiler, T. G. (1998) · Experimental Eye Research · doi:10.1006/exer.1997.0410 · Cited by 980 · cited 1×
“Corneal cross-linking (CXL) treatment Corneal cross-linking 102,103 is a photodynamic method that is based on the generation of oxygen radicals by means of riboflavin and UV-A irradiation.”
Collagen crosslinking with riboflavin and ultraviolet-A light in keratoconus: Long-term results
Raiskup-Wolf, F., Hoyer, A., Spoerl, E., & Pillunat, L. E. (2008) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2007.12.039 · Cited by 946 · cited 1×
“CXL has been shown to stabilise corneal ectasia on the long-term.(106) In an ex vivo study,(49) corneal stiffness increased by 329% in human and by 72% in por cine corneas after CXL treatment.”
Safety of UVA-Riboflavin Cross-Linking of the Cornea
Spoerl, E., Mrochen, M., Sliney, D., Trokel, S., & Seiler, T. (2007) · Cornea · doi:10.1097/ico.0b013e3180334f78 · Cited by 809
Increased resistance of crosslinked cornea against enzymatic digestion
Spoerl, E., Wollensak, G., & Seiler, T. G. (2004) · Current Eye Research · doi:10.1080/02713680490513182 · Cited by 709 · cited 1×
“Other enzymes that have been applied in this context are collagenases and trypsin.(87) Although using selective enzymatic digestion would allow studying the impact of certain ECM components on the resulting biomechanical properties, these studies are still outstanding.”
Brillouin, L. (1922) · Annales de Physique · doi:10.1051/anphys/192209170088 · Cited by 678
Proteoglycan-fibrillar collagen interactions
Scott, J. E. (1988) · Biochemical Journal · doi:10.1042/bj2520313 · Cited by 676
Confocal Brillouin microscopy for three-dimensional mechanical imaging
Scarcelli, G., & Yun, S. H. (2008) · Nature Photonics · doi:10.1038/nphoton.2007.250 · Cited by 539 · cited 1×
“In 2008, Scarcelli et al. 62 presented the first scanning system that allowed to measure the cross-section of intraocular and crystalline lenses.”
Biomechanics and wound healing in the cornea
Dupps, W. J., & Wilson, S. E. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.03.015 · Cited by 510 · cited 1×
“22,96 Nevertheless, it has been shown that the largest post-surgical change in biomechanical parameters occurs within 1 week after surgery.”
Changes in Collagen Orientation and Distribution in Keratoconus Corneas
Meek, K. M., Tuft, S. J., Huang, Y., Gill, P. S., Hayes, S., Newton, R. H., & Bron, A. J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1253 · Cited by 509
Human Corneal Anatomy Redefined
Dua, H. S., Faraj, L. A., Said, D. G., Gray, T., & Lowe, J. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.01.018 · Cited by 471 · cited 1×
“The pre-descemet membrane, also known as Dua’s layer, has been discovered only recently.(23) Due to its mechanical strength, it is has been postulated to contribute significantly to corneal stiffness.”
Atopy and keratoconus: a multivariate analysis
Bawazeer, A. M. (2000) · British Journal of Ophthalmology · doi:10.1136/bjo.84.8.834 · Cited by 419
Assessment of Corneal Biomechanical Properties and Their Variation with Age
Elsheikh, A., Wang, D., Brown, M., Rama, P., Campanelli, M., & Pye, D. (2007) · Current Eye Research · doi:10.1080/02713680601077145 · Cited by 394 · cited 1×
“While eye-rubbing has been associated to keratoconus, 41,42 ageing 43,44 and smoking 45,46 have both been reported to stiffen the corneal tissue and to reduce the incidence of keratoconus.”
Reinstein, D. Z., Archer, T. J., & Randleman, J. B. (2013) · Journal of Refractive Surgery · doi:10.3928/1081597x-20130617-03 · Cited by 354 · cited 1×
“134 Further simulations could show that the refractive outcome after LASIK depends on the inherent corneal stiffness – not only on the amount of tissue ablated, 135 and that tonome-try underestimates the actual IOP following PRK or LASIK surgery.”
Ocular Rigidity in Living Human Eyes
Pallikaris, I. G., Kymionis, G. D., Ginis, H. S., Kounis, G. A., & Tsilimbaris, M. K. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0162 · Cited by 301 · cited 1×
“For in vivo measurements, Pal-likaris et al. 59 developed a protocol, where the whole eye is inflated during surgery and the corresponding rise in IOP measured in order to determine ocular rigidity.”
The parameters of the porcine eyeball
Sanchez, I., Martin, R., Ussa, F., & Fernandez-Bueno, I. (2011) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-011-1617-9 · Cited by 298 · cited 1×
“In view of anatomical differences only a less developed or absent Bowman’s membrane 114 – 116 and a higher corneal thickness (666 l m centrally) 117 becomes apparent in the porcine cornea.”
Scarcelli, G., Kling, S., Quijano, E., Pineda, R., Marcos, S. C., & Yun, S. H. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-11387 · Cited by 285
Self-citationCigarette Smoking is Negatively Associated With Keratoconus
Spoerl, E., Raiskup-Wolf, F., Kuhlisch, E., & Pillunat, L. E. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080901-18 · Cited by 280 · cited 1×
“While eye-rubbing has been asso ciated to keratoconus,(41,42) ageing(43,44) and smoking(45,46) have both been reported to stiffen the corneal tissue and to reduce the incidence of keratoconus.(45) Eye-rubbing induces ocular trauma and may trigger inflammation increasing the degradation of the ECM.”
Optical coherence elastography for tissue characterization: a review
Wang, S., & Larin, K. V. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400108 · Cited by 270 · cited 1×
“Therefore, more recently, non-contact elastography based on OCT imaging has been developed.(84) Because light has less impact on the corneal tissue than ultrasound, lowamplitude elastics waves need to be induced using a differ ent source.”
The Cascade Hypothesis of Keratoconus
Cristina Kenney, M., & Brown, D. J. (2003) · Contact Lens and Anterior Eye · doi:10.1016/s1367-0484(03)00022-5 · Cited by 254 · cited 1×
“A susceptibility to keratoconus has been reported with Trisomy 21, Leber’s congential amaurosis, Ehler-Danlos syndrome and osteogenesis imperfecta.(33) The latter two diseases directly affect collagen synthesis, and the corneal ectasia potentially arises from an instable collagen network.”
Biomechanical properties of human and porcine corneas
Elsheikh, A., Alhasso, D., & Rama, P. (2008) · Experimental Eye Research · doi:10.1016/j.exer.2008.02.006 · Cited by 253 · cited 1×
“118,119 Nevertheless – considering their abundant availability – porcine eyes are widely accepted as a model for biomechanical studies of the cornea.”
Biomechanical Characterization of Keratoconus Corneas Ex Vivo With Brillouin Microscopy
Scarcelli, G., Besner, S., Pineda, R., & Yun, S. H. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14450 · Cited by 250 · cited 1×
“Meanwhile, Brillouin microscopy has also been applied to perform measure ments in human eyes in vivo,(63) to quantify the stiffening effect of cross-linking(64) and to identify weakened regions in keratoconus corneas.(65) The Brillouin modulus M0 of an untreated porcine cornea roughly falls between 2.”
Meek, K. M., & Boote, C. (2009) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2009.06.005 · Cited by 247 · cited 1×
“12 Orthogonal orientation provides the highest visual acuity and is expected to best maintain the corneal shape, followed by vertical orientation (marmoset, horse, cow) before circumferential orientation (pig, rabbit mouse).”
Pandolfi, A., & Holzapfel, G. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2982251 · Cited by 245
A model for the human cornea: constitutive formulation and numerical analysis
Pandolfi, A., & Manganiello, F. (2006) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-005-0014-x · Cited by 239 · cited 1×
“For inflation experiments, the comparison of model predictions and experimental measurements could previously confirm a good performance.(125,126)”
Collagens and proteoglycans of the corneal extracellular matrix
Michelacci, Y. M. (2003) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2003000800009 · Cited by 236 · cited 1×
“It is generally understood that keratan sulfate proteoglycans regulate the diameter of collagen fibrils, while dermatan sulfate proteoglycans determine the interfibrillar spacing and lamellar adhesion properties.(1) GAGs interfere with collagen electrostatically only(2) and therefore hardly affect nucleation or growth…”
Corneal Deformation Measurement Using Scheimpflug Noncontact Tonometry
Hon, Y., & Lam, A. K. C. (2013) · Optometry and Vision Science · doi:10.1097/opx.0b013e318279eb87 · Cited by 235
High-Resolution Quantitative Imaging of Cornea Elasticity Using Supersonic Shear Imaging
Tanter, M., Touboul, D., Gennisson, J.-L., Bercoff, J., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2021471 · Cited by 234 · cited 3×
“82 For the measurement of the corneal tissue, contact with a coupling liquid is needed.”
Regional elastic performance of the human cornea
Hjortdal, J. Ø. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00152-2 · Cited by 231 · cited 1×
“For ex vivo measurements, corneal button and whole eye inflation set ups were designed, where either the displacement of mercury droplets, 55 graphite flakes, 56 the corneal apex 57 or curvature changes 58 were recorded.”
Corneal Biomechanical Metrics and Anterior Segment Parameters in Mild Keratoconus
Fontes, B. M., Ambrósio, R., Jardim, D., Velarde, G. C., & Nosé, W. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2009.09.023 · Cited by 230
Proteoglycans and collagen fibre organization in human corneoscleral tissue
Borcherding, M. S., Blacik, L. J., Sittig, R. A., Bizzell, J. W., Breen, M., & Weinstein, H. G. (1975) · Experimental Eye Research · doi:10.1016/0014-4835(75)90057-3 · Cited by 226 · cited 1×
“The amount of acidic GAGs directly correlates with the degree of collagen fibre organi sation along the human corneal stroma.(5,6) Differences in GAG and PG composition are concomi tant with physiological modifications.”
Zhang, G., Chen, S., Goldoni, S., Calder, B. W., Simpson, H. C., Owens, R. T., McQuillan, D. J., Young, M. F., Iozzo, R. V., & Birk, D. E. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m806590200 · Cited by 224 · cited 1×
“Studies on decorin-null mice presented a disrupted collagen fibril structure and organisation especially in the posterior cornea.(109) Crystallography analysis of corneal samples with a truncated decorin mutation confirmed this finding.”
Identification of Biomechanical Properties of the Cornea: The Ocular Response Analyzer
Terai, N., Raiskup, F., Haustein, M., Pillunat, L. E., & Spoerl, E. (2012) · Current Eye Research · doi:10.3109/02713683.2012.669007 · Cited by 223 · cited 1×
“The ocular response analyser(67) was the first device that tried to related the dynamic deformation response of the cornea with biomechanical parameters.(68) It measures the pressure difference between the inward and outward applanation, the so-called corneal hysteresis.”
The mechanical properties of the rabbit and human cornea
Jue, B., & Maurice, D. M. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90135-1 · Cited by 222 · cited 2×
“50 Recently, our group has established a corneal biome-chanics model in the mouse eye.”
InfluentialComputational modeling of mechanical anisotropy in the cornea and sclera
Pinsky, P. M., van der Heide, D., & Chernyak, D. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.10.048 · Cited by 220 · cited 1×
“…inverse modelling needs to be performed: Either the IOP-induced stress is computed step-wise until the initial stress state of the cornea is determined, 124 or the provoked deformation is calculated step-wise and subtracted from the stressed geometry in order to obtain the stress-free geometry.”
Comparative study of corneal strip extensometry and inflation tests
Elsheikh, A., & Anderson, K. (2005) · Journal of The Royal Society Interface · doi:10.1098/rsif.2005.0034 · Cited by 217
In vivo Brillouin optical microscopy of the human eye
Scarcelli, G., & Yun, S. H. (2012) · Optics Express · doi:10.1364/oe.20.009197 · Cited by 216 · cited 1×
“Meanwhile, Brillouin microscopy has also been applied to perform measurements in human eyes in vivo , 63 to quantify the stiffening effect of cross-linking 64 and to identify weakened regions in keratoconus corneas.”
Thermal and Biomechanical Parameters of Porcine Cornea
Kampmeier, J., Radt, B., Birngruber, R., & Brinkmann, R. (2000) · Cornea · doi:10.1097/00003226-200005000-00020 · Cited by 210
Boote, C., Dennis, S., Newton, R. H., Puri, H., & Meek, K. M. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0131 · Cited by 209
Roles of lumican and keratocan on corneal transparency
Kao, W. W.-Y., & Liu, C.-Y. (2002) · Glycoconjugate Journal · doi:10.1023/a:1025396316169 · Cited by 207
Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties
Ambrósio Jr, R., Ramos, I., Luz, A., Faria, F. C., Steinmueller, A., Krug, M., Belin, M. W., & Roberts, C. J. (2013) · Revista Brasileira de Oftalmologia · doi:10.1590/s0034-72802013000200005 · Cited by 205
Roy, A. S., Dupps, W. J., & Roberts, C. J. (2014) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2013.08.065 · Cited by 204
Age-Related Differences in the Elasticity of the Human Cornea
Knox Cartwright, N. E., Tyrer, J. R., & Marshall, J. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4798 · Cited by 194
Full-field deformation of bovine cornea under constrained inflation conditions
Boyce, B. L., Grazier, J. M., Jones, R. E., & Nguyen, T. D. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.011 · Cited by 191
Pradhan, K. R., Reinstein, D. Z., Carp, G. I., Archer, T. J., Gobbé, M., & Gurung, R. (2013) · Journal of Refractive Surgery · doi:10.3928/1081597x-20131021-07 · Cited by 186 · cited 2×
“This unintended flattening acts contrary to the desired central steepening, and might explain why only 50% of the expected refractive correction were achieved after SMILE lenticule implantation.(112)”
Corneal Biomechanical Changes after Collagen Cross-Linking from Porcine Eye Inflation Experiments
Kling, S., Remon, L., Pérez‐Escudero, A., Merayo-Llovés, J., & Marcos, S. C. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-4536 · Cited by 183
Self-citationRoy, A. S., & Dupps, W. J. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-7395 · Cited by 182 · cited 1×
“Several in silico (computational) studies have predicted the weakening profile of a cornea presenting keratectasia(127) and the expected response to CXL treatment.(123,127) These simulations could confirm the clinically observed topographic flattening after CXL,(127) but showed important inter-patient variability indi…”
Advanced glycation end products in diabetic corneas.
Kaji, Y., Usui, T., Oshika, T., Matsubara, M., Yamashita, H., Araie, M., Murata, T., Ishibashi, T., Nagai, R., Horiuchi, S., et al. (2000) · PubMed · Cited by 180
A microstructurally-based finite element model of the incised human cornea
Pinsky, P. M., & Datye, D. V. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90169-n · Cited by 159 · cited 1×
“Several years ago, computer models addressed the potential of myopic and astigmatic correction by incision surgery.(129,130) More recently, simulations are applied to estimate the long-term impact of laser ablative surgery: PRK surgery showed to increase the corneal stress by approx.”
Biomechanical properties of the keratoconic cornea: a review
Vellara, H. R., & Patel, D. V. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12211 · Cited by 159
Biomechanical Modeling of Refractive Corneal Surgery
Alastrué, V., Calvo, B., Peña, E., & Doblaré, M. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2132368 · Cited by 152
Corneal cross‐linking – a review
Meek, K. M., & Hayes, S. (2013) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12032 · Cited by 149 · cited 1×
“Corneal cross-linking (CXL) treatment Corneal cross-linking 102,103 is a photodynamic method that is based on the generation of oxygen radicals by means of riboflavin and UV-A irradiation.”
Oestrogen-induced changes in biomechanics in the cornea as a possible reason for keratectasia
Spoerl, E., Zubaty, V., Raiskup-Wolf, F., & Pillunat, L. E. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.124388 · Cited by 146 · cited 1×
“Oestrogen administration to ex vivo corneas reduces the biomechanical stiffness by 36%.(40)”
Dawson, D. G., Grossniklaus, H. E., McCarey, B. E., & Edelhauser, H. F. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080101-16 · Cited by 144
The architecture of the corneal stroma
BRON, A. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.379 · Cited by 143 · cited 1×
“9 Also, in large animals with high corneal thicknesses – such as cows, pigs or humans – the KS-GAG proportion reaches up to 60 – 70%, 9 while in small animals, such as mice, KS is completely absent.”
Depth-Dependent Transverse Shear Properties of the Human Corneal Stroma
Petsche, S. J., Chernyak, D., Martiz, J., Levenston, M. E., & Pinsky, P. M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8611 · Cited by 141 · cited 1×
“15 Collagen organisation is disturbed in certain degrading pathologies such as keratoconus, 16 demonstrating their importance for maintaining corneal shape.”
Understanding the Importance of IOP Variables in Glaucoma: A Systematic Review
Sultan, M. B., Mansberger, S. L., & Lee, P. P. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2009.05.001 · Cited by 128 · cited 1×
“An accurate measurement of the intraocular pressure (IOP) is essential in the diagnosis of glaucoma.(100) Due to limited accessibility of the posterior chamber, the IOP is typically measured via the cornea.”
Corneal Viscoelastic Properties from Finite-Element Analysis of In Vivo Air-Puff Deformation
Kling, S., Békési, N., Dorronsoro, C., Pascual, D., & Marcos, S. C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104904 · Cited by 125 · cited 2×
“This kind of viscoelastic definition has been applied in a study to retrieve biomechanical parameters from air-puff deformation.(54)”
Self-citationHydration dependent biomechanical properties of the corneal stroma
Hatami-Marbini, H., & Etebu, E. (2013) · Experimental Eye Research · doi:10.1016/j.exer.2013.07.016 · Cited by 124 · cited 1×
“…corneal hydration not only affects its trans-parency, but also its elastic modulus: the more hydrated the corneal tissue, the lower its elastic modulus, 17,18 which potentially arises from an altered collagen attachment to the proteoglycans an/or glycosaminoglycans based on their ionic interaction.”
Pregnancy-induced Progression of Keratoconus
Bïlgïhan, K., Hondur, A., Sül, S., & Ozturk, S. (2011) · Cornea · doi:10.1097/ico.0b013e3182068adc · Cited by 113 · cited 2×
“Also, pregnancy 36 – 38 and pathologi-cally-reduced levels of thyroid hormones 39 have been reported in context with the onset or progression of corneal ectasia.”
Is There an Association between Diabetes and Keratoconus?
Kuo, I. C., Broman, A. T., Pirouzmanesh, A., & MELIA, M. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.10.009 · Cited by 109 · cited 1×
“24,25 Also, diabetes has a protective effect on the incidence rate 26 and severity 27 of degrading corneal diseases such as keratoconus.”
Comparative Study of Fibrillar Collagen Arrangement in the Corneas of Primates and Other Mammals
Hayes, S., Boote, C., Lewis, J., Sheppard, J., Abahussin, M., Quantock, A. J., Purslow, C., Votruba, M., & Meek, K. M. (2007) · The Anatomical Record · doi:10.1002/ar.20613 · Cited by 108 · cited 3×
“Most species present a lower corneal stiffness and a higher viscoelastic creep behaviour than humans, which might be attributed to differences in the fibrillar collagen arrangement.(11) For ex vivo experiments, freshly enucleated porcine corneas are often used(49,58,64,70,87,88,111) because of their similar anatomy co…”
InfluentialAssessment of the epithelium's contribution to corneal biomechanics
Elsheikh, A., Alhasso, D., & Rama, P. (2007) · Experimental Eye Research · doi:10.1016/j.exer.2007.12.002 · Cited by 107
Structural and biochemical aspects of keratan sulphate in the cornea
Quantock, A. J., Young, R. D., & Akama, T. O. (2009) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-009-0228-7 · Cited by 102 · cited 1×
“Keratan sulfate proteoglycans are generally understood to stabilise colla gen fibrils on the short-range, while chondroitin sulfate/ dermatan sulfate proteoglycans stabilize several fibrils as far as lamellae.(10) Therefore, a decrease in chondroitin sul fate proteoglycans potentially weakens the cornea and facilita…”
Han, Z., Aglyamov, S. R., Li, J., Singh, M., Wang, S., Vantipalli, S., Wu, C., Liu, C., Twa, M. D., & Larin, K. V. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.2.020501 · Cited by 102 · cited 1×
“The elastic moduli determined by optical coherence elastography are in the range of 60 kPa for untreated porcine corneal samples.(86)”
Roy, A. S., Kurian, M., Matalia, H. P., & Shetty, R. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.04.010 · Cited by 99
Roy, A. S., & Dupps, W. J. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4002934 · Cited by 93 · cited 1×
“25%,(131) while LASIK surgery was predicted to induce a 55% corneal weakening.(132) A comparison between LASIK and SmILE refractive surgery concluded that SmILE increases the corneal stress to a lesser amount than LASIK,(133) which also has been suggested theoretically.”
Viscoelastic shear properties of the corneal stroma
Hatami-Marbini, H. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.11.019 · Cited by 91 · cited 1×
“53 Another possibility to define viscoelastic properties is to use an n -element Prony series.”
Topographic and biomechanical differences between hyperopic and myopic laser in situ keratomileusis
Qazi, M. A., Roberts, C. J., Mahmoud, A. M., & Pepose, J. S. (2005) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2004.10.043 · Cited by 89
Changes of Corneal Biomechanics With Keratoconus
Wolffsohn, J. S., Safeen, S., Shah, S., & Laiquzzaman, M. (2012) · Cornea · doi:10.1097/ico.0b013e318243e42d · Cited by 87 · cited 2×
“In contrast, the ECM of the keratoconic cornea is dispro-portionally degraded leading to a loss of collagen fibril orientation, 16 biomechanical weakening 29 – 32 and out-bulging of the cornea into a conical shape.”
Corneal biomechanical characteristics in patients with diabetes mellitus
Kotecha, A., Oddone, F., Sinapis, C., Elsheikh, A., Sinapis, D., Sinapis, A., & Garway‐Heath, D. F. (2010) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2010.08.027 · Cited by 87 · cited 1×
“24,25 Also, diabetes has a protective effect on the incidence rate 26 and severity 27 of degrading corneal diseases such as keratoconus.”
Finite element simulations of laser refractive corneal surgery
Pandolfi, A. M., Fotia, G., & Manganiello, F. (2008) · Engineering With Computers · doi:10.1007/s00366-008-0102-5 · Cited by 87
Altered antigenicity of keratan sulfate proteoglycan in selected corneal diseases.
Funderburgh, J. L., Funderburgh, M. L., Rodrigues, M. M., Krachmer, J. H., & Conrad, G. W. (1990) · PubMed · Cited by 78
Corneal Thickness in Pigs Measured by Ultrasound Pachymetry In Vivo
Faber, C., Scherfig, E., Prause, J. U., & Sørensen, K. E. (2014) · Scandinavian journal of laboratory animal science · doi:10.23675/sjlas.v35i1.139 · Cited by 74
Acute keratoconus induced by hypothyroxinemia during pregnancy
Gatzioufas, Z., & Thanos, S. (2008) · Journal of Endocrinological Investigation · doi:10.1007/bf03345600 · Cited by 73 · cited 1×
“Also, pregnancy 36 – 38 and pathologi-cally-reduced levels of thyroid hormones 39 have been reported in context with the onset or progression of corneal ectasia.”
Scott, J. E., & HAIGH, M. (1988) · PubMed Central · Cited by 71
Kling, S., & Marcos, S. C. (2013) · Journal of Refractive Surgery · doi:10.3928/1081597x-20130617-08 · Cited by 70
Self-citationNumerical modelling of corneal biomechanical behaviour
Elsheikh, A., & Wang, D. (2006) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840600976013 · Cited by 69 · cited 1×
“125,126 Corneal ectasia and corneal cross-linking Numerical simulations might be a helpful tool to predict the individual success rate of CXL in stopping progression of ectasia, but also to predict the associated corneal re-shaping and hence refractive changes.”
Evaluating Corneal Collagen Organization Using High-Resolution Nonlinear Optical Macroscopy
Jester, J. V., Winkler, M., Jester, B. E., Nien, C., Chai, D., & Brown, D. J. (2010) · Eye & Contact Lens: Science & Clinical Practice · doi:10.1097/icl.0b013e3181ee8992 · Cited by 64
Jay, L., Brocas, A., Singh, K., Kieffer, J. C., Brunette, I., & Ozaki, T. (2008) · Optics Express · doi:10.1364/oe.16.016284 · Cited by 64 · cited 1×
“In view of anatomical differences only a less developed or absent Bowman’s membrane 114 – 116 and a higher corneal thickness (666 l m centrally) 117 becomes apparent in the porcine cornea.”
Swelling Pressure and Hydration Behavior of Porcine Corneal Stroma
Hatami-Marbini, H., Etebu, E., & Rahimi, A. (2013) · Current Eye Research · doi:10.3109/02713683.2013.809769 · Cited by 63 · cited 1×
“19 At 666 l m thickness, porcine corneas show a hydration of 3.36 mg H2O /mg dry_weight and a swelling pressure of 52 mmHg. 20”
InfluentialAldahlawi, N. H., Hayes, S., O'Brart, D. P. S., & Meek, K. M. (2015) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2015.10.004 · Cited by 59
Corneal biomechanical evaluation in healthy thin corneas compared with matched keratoconus cases
Fontes, B. M., Ambrósio, R., Velarde, L. G. C., & Nosé, W. (2011) · Arquivos Brasileiros de Oftalmologia · doi:10.1590/s0004-27492011000100003 · Cited by 49 · cited 2×
“78”
Aldahlawi, N. H., Hayes, S., O'Brart, D. P. S., Akhbanbetova, A., Littlechild, S. L., & Meek, K. M. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-18769 · Cited by 44
He, X., & Liu, J. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3439 · Cited by 41
Changes in Corneal Biomechanics and Applanation Tonometry with Induced Corneal Swelling
Lau, W., & Pye, D. C. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6754 · Cited by 38 · cited 1×
“79 However in most studies only minor to no changes could be detected demonstrating the need of a more detailed analysis of the recorded deformation profile.”
Kling, S., Spiru, B., Hafezi, F., & Sekundo, W. (2017) · Journal of Refractive Surgery · doi:10.3928/1081597x-20161221-01 · Cited by 36
Self-citationRole of Decorin Core Protein in Collagen Organisation in Congenital Stromal Corneal Dystrophy (CSCD)
Kamma‐Lorger, C. S., Pinali, C., Martínez, J. C., Harris, J., Young, R. D., Bredrup, C., Crosas, E., Malfois, M., Rødahl, E., Meek, K. M., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0147948 · Cited by 34 · cited 1×
“110 The administration of decorin core protein to a keratoconic cornea therefore might have the potential to re-establish the physiologic collagen structure and halt the progressing ectasia.”
Repeatability of a novel corneal indentation device for corneal biomechanical measurement
Lam, A. K. C., Hon, Y., Leung, L. K. K., & LAM, D. C. C. (2015) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12219 · Cited by 34 · cited 2×
“Lam et al.(60) used a flat surface cylinder to perform indentation measure ments and estimated corneal stiffness from the inward dis placement.”
Lai, T., & Tang, S. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.001494 · Cited by 28
Hammer, A., Kling, S., Boldi, M., Richoz, O., Tabibian, D., Randleman, J. B., & Hafezi, F. (2015) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-17426 · Cited by 27 · cited 1×
“Recently, our group has established a corneal biome chanics model in the mouse eye.(121) We observed a linear stress-strain relation similar to rabbit corneas, which could make the mouse an attractive model for studies addressing the molecular origin of biomechanical parameters.”
Self-citationMetzler, K. M., Roberts, C. J., Mahmoud, A. M., Agarwal, G., & Liu, J. (2016) · Journal of Refractive Surgery · doi:10.3928/1081597x-20160428-08 · Cited by 23 · cited 2×
“111 Compared to CXL with a 72% stiffening in porcine eyes, 49 decorin core treatment does not require de-epithelialisation nor UV irradiation and therefore might be less invasive.”
Modeling Collagen-Proteoglycan Structural Interactions in the Human Cornea
Cheng, X., Hatami-Marbini, H., & Pinsky, P. M. (2012) · Springer eBooks · doi:10.1007/978-94-007-5464-5_2 · Cited by 22
Cited by
Kwok, S., Clayson, K., Hazen, N., Pan, X., Ma, Y., Hendershot, A. J., & Liu, J. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.13.33 · Cited by 19
Metadata
- Authors
- Kling, S., & Hafezi, F.
- Venue
- Ophthalmic and Physiological Optics
- Published
- 2017-01-26
- Volume
- 37
- Issue
- 3
- Pages
- 240-252
- ISSN
- 0275-5408 (ISSN-L)
- 1475-1313
- OpenAlex
- W2582934691
- Cited by
- 194
- References
- 95
- FWCI
- 9.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.