Abstract
Background: The implantable cardioverter defibrillator (ICD) is the first‐line treatment for primary and secondary prevention of sudden cardiac death. A subgroup of patients experience psychological distress postimplant, and no clear evidence base exists regarding how best to address patients’ needs. The aim of this critical review is to provide an overview of behavioral interventions in ICD patients to date, and to delineate directions for future research using lessons learned from the ongoing RISTA and WEBCARE trials. Methods: We searched the PubMed and PsycInfo databases to identify reports of behavioral trials targeting distress and related factors in ICD patients published between 1980 and April 2012. Results: We identified 17 trials for the review. Generally, compared to usual care, behavioral interventions were associated with reduced anxiety and depression and improved physical functioning, with effect sizes ranging from small to moderate‐large (0.10–1.79 for anxiety; 0.23–1.20 for depression). Important limitations were small sample sizes and potential selection bias, hampering generalizability of the results. In addition to a need for larger trials, experiences from the RISTA and WEBCARE trials suggest that intervention trials tailored to the individual patient may be the way forward. Conclusions: Behavioral interventions show promise with respect to reducing distress in ICD patients. Large‐scale intervention trials targeted to the individual needs and preferences of patients are warranted, as a “one size fits all” approach is unlikely to work for all ICD patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moher, D. (2001) · JAMA · doi:10.1001/jama.285.15.1987 · Cited by 2,545
Randomized Trials or Observational Tribulations?
Pocock, S. J., & Elbourne, D. R. (2000) · New England Journal of Medicine · doi:10.1056/nejm200006223422511 · Cited by 550
Computer‐Aided Psychotherapy for Anxiety Disorders: A Meta‐Analytic Review
Cuijpers, P., Marks, I. M., van Straten, A., Cavanagh, K., Gega, L., & Andersson, G. (2009) · Cognitive Behaviour Therapy · doi:10.1080/16506070802694776 · Cited by 429
Kessler, D., Lewis, G., Kaur, S., Wiles, N., King, M., Weich, S., Sharp, D. J., Araya, R., Hollinghurst, S., & Peters, T. J. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61257-5 · Cited by 387
Davidson, K. W., Rieckmann, N., Clemow, L., Schwartz, J. E., Shimbo, D., Medina, V., Albanese, G., Kronish, I., Hegel, M., & Burg, M. M. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2010.29 · Cited by 350
Self-citationMagyar-Russell, G., Thombs, B. D., Cai, J. X., Baveja, T., Kuhl, E. A., Singh, P. P., Montenegro Braga Barroso, M., Arthurs, E., Roseman, M., Amin, N., et al. (2011) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2011.02.014 · Cited by 267
Internet-Based Treatment for Adults with Depressive Symptoms: Randomized Controlled Trial
Warmerdam, L., van Straten, A., Twisk, J., Riper, H., & Cuijpers, P. (2008) · Journal of Medical Internet Research · doi:10.2196/jmir.1094 · Cited by 255
Pedersen, S. S., van Domburg, R. T., Theuns, D. A. M. J., Jordaens, L., & Erdman, R. A. M. (2004) · Psychosomatic Medicine · doi:10.1097/01.psy.0000132874.52202.21 · Cited by 207
Self-citationBehavioral Activation Is an Evidence-Based Treatment for Depression
Sturmey, P. (2009) · Behavior Modification · doi:10.1177/0145445509350094 · Cited by 185
The short-term effects of a hostility-reduction intervention on male coronary heart disease patients
Gidron, Y., Davidson, K., & Bata, I. (1999) · Health Psychology · doi:10.1037/0278-6133.18.4.416 · Cited by 136
Risk of Ventricular Arrhythmia After Implantable Defibrillator Treatment in Anxious Type D Patients
van den Broek, K. C., Nyklíček, I., van der Voort, P. H., Alings, M., Meijer, A., & Denollet, J. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.043 · Cited by 110
Irvine, J., Firestone, J., Ong, L., Cribbie, R., Dorian, P., Harris, L., Ritvo, P., Katz, J., Newman, D., Cameron, D., et al. (2011) · Psychosomatic Medicine · doi:10.1097/psy.0b013e31820afc63 · Cited by 103
Prevention of implantable defibrillator shocks by cognitive behavioral therapy: A pilot trial
Chevalier, P., Cottraux, J., Mollard, E., Sai, N., Brun, S., Burri, H., Restier, L., & Adeleine, P. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.10.007 · Cited by 81
Piotrowicz, K., Noyes, K., Lyness, J. M., McNitt, S., Andrews, M. L., Dick, A., Hall, W. J., Moss, A. J., & Zareba, W. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl485 · Cited by 68
VAZQUEZ, L. D., CONTI, J. B., & SEARS, S. F. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02787.x · Cited by 51
Kuhl, E. A., Sears, S. F., Vazquez, L. D., & Conti, J. B. (2009) · Journal of Cardiovascular Nursing · doi:10.1097/jcn.0b013e31819c143d · Cited by 34
Research works printed but not linked: 38
- 10.7326/0003-4819-138-6-200303180-00007 · DOI · Paper page
- 10.1016/j.jacc.2006.07.010 · DOI · Paper page
- 10.1016/j.ijcard.2011.10.092 · DOI
- 10.1001/archpsyc.65.11.1324 · DOI · Paper page
- 10.1093/europace/euq154 · DOI · Paper page
- 10.1136/heart.87.5.488 · DOI · Paper page
- 10.1002/(SICI)1520-6394(1999)9:4<163::AID-DA3>3.0.CO;2-B · DOI · Paper page
- 10.1016/j.hrtlng.2004.10.002 · DOI
- 10.1002/clc.4960260303 · DOI · Paper page
- 10.1037/a0024701 · DOI · Paper page
- 10.1093/europace/eun073 · DOI · Paper page
- 10.1111/j.1540-8159.2009.02641.x · DOI
- 10.1093/europace/euq296 · DOI · Paper page
- 10.1037/a0028018 · DOI · Paper page
- 10.1186/1471-2261-9-56 · DOI · Paper page
- 10.1111/j.1540-8159.2007.00905.x · DOI · Paper page
- 10.1097/PSY.0b013e3181c932d4 · DOI · Paper page
- 10.1186/1745-6215-10-120 · DOI · Paper page
- Cohen J, 1988, Statistical Power Analysis for the Behavioral Sciences
- 10.1097/PSY.0b013e3181d9bcec · DOI · Paper page
- 10.1111/j.1540-8159.2009.02495.x · DOI · Paper page
- 10.1111/j.1540-8159.2004.00691.x · DOI · Paper page
- 10.1136/heart.89.2.155 · DOI · Paper page
- 10.1111/j.1540-8159.2000.tb00826.x · DOI · Paper page
- 10.1136/hrt.2007.129890 · DOI · Paper page
- 10.1111/j.1540-8159.2007.00773.x · DOI · Paper page
- 10.1348/1359107041557039 · DOI · Paper page
- 10.1111/j.1540-8159.2005.09500.x · DOI · Paper page
- Badger JM, 1989, Observations of a support group for automatic implantable cardioverter‐defibrillator recipients and their spouses, Heart Lung, 18, 238
- Edelman S, 2007, Educational intervention for patients with automatic implantable cardioverter defibrillators, Aust J Adv Nurs, 24, 26
- Molchany CA, 1994, The psychosocial effects of support group intervention on AICD recipients and their significant others, Prog Cardiovasc Nurs, 9, 23
- 2001, ENRICHD Investigators. Enhancing Recovery in Coronary Heart Disease (ENRICHD) study intervention: Rationale and design, Psychosom Med, 63, 747
- 10.1016/j.hrtlng.2006.02.004 · DOI
- 10.1097/00005650-200108000-00005 · DOI · Paper page
- 10.1207/S15324796ABM2603_01 · DOI · Paper page
- 10.1161/CIRCULATIONAHA.104.508663 · DOI · Paper page
- 10.1111/j.0889-7204.2002.00613.x · DOI
- Sneed NV, 1997, The effect of psychosocial nursing intervention on the mood state of patients with implantable cardioverter defibrillators and their caregivers, Prog Cardiovasc Nurs, 12, 4
Cited by
Habibović, M., Cuijpers, P., Alings, M., van der Voort, P., Theuns, D., Bouwels, L., Herrman, J.-P., Valk, S., & Pedersen, S. (2014) · Journal of Medical Internet Research · doi:10.2196/jmir.2809 · Cited by 47
“One possible explanation for this is the lack of well-designed, validated, randomized controlled trials (RCTs), leaving us with insufficient knowledge for the establishment of a sufficient evidence base to inform clinical practice [14].”
Self-citationHabibović, M., Denollet, J., Cuijpers, P., Spek, V. R. M., van den Broek, K. C., Warmerdam, L., van der Voort, P. H., Herrman, J.-P., Bouwels, L., Valk, S. S. D., et al. (2014) · Psychosomatic Medicine · doi:10.1097/psy.0000000000000096 · Cited by 38
Self-citationLANG, S., BECKER, R., WILKE, S., HARTMANN, M., HERZOG, W., & LÖWE, B. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12276 · Cited by 36
Habibović, M., Denollet, J., Cuijpers, P., van der Voort, P. H., Herrman, J.-P., Bouwels, L., Valk, S. D. A., Alings, M., Theuns, D. A. M. J., & Pedersen, S. S. (2017) · Health Psychology · doi:10.1037/hea0000451 · Cited by 26
Self-citationPedersen, S. S., Skovbakke, S. J., Wiil, U. K., Schmidt, T., dePont Christensen, R., Brandt, C. J., Sørensen, J., Vinther, M., Larroudé, C. E., Melchior, T. M., et al. (2018) · BMC Cardiovascular Disorders · doi:10.1186/s12872-018-0872-7 · Cited by 18
Self-citation
Metadata
- Authors
- HABIBOVIĆ, M., BURG, M. M., & PEDERSEN, S. S.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2013-02-25
- Volume
- 36
- Issue
- 5
- Pages
- 578-590
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1541339089
- Cited by
- 48
- References
- 16
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.