The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Phosphenes produced by electrical stimulation of human occipital cortex, and their application to the development of a prosthesis for the blind
Open accessAbstract
1. To explore the feasibility of a visual prosthesis for the blind, human visual cortex has been stimulated during a series of surgical procedures on conscious volunteers undergoing other occipital lobe surgery. 2. Area no. 17 seems the most effective locus for such stimulation, at least in sighted or recently hemianopic patients. 3. Changes in electrode size and configuration, or in stimulus parameters, have little effect on subjective sensation. 4. Thresholds do vary depending on parameters, but not electrode size, and these effects have been studied. 5. Painful effects are associated with stimulation of the dura, but not of the calcarine artery and associated vessels. 6. Stimulation of a single electrode usually produces one phosphene, whose size ranges from tiny punctate sensations like ‘a star in the sky’ up to a large coin at arm's length. Very large elongated phosphenes, like those seen by Brindley's second patient, have not been reported despite the number of patients, electrodes, and combinations of stimulus parameters tested. These large phosphenes may be an effect of prolonged blindness. 7. Stimulation substantially above threshold may produce a second conjugate phosphene, inverted about the horizontal meridian. 8. Stimulation of a single electrode may also produce multiple phosphenes with no differential threshold. 9. Chromatic effects and/or phosphene flicker may, or may not occur. This can vary from point to point on the same patient. 10. Phosphenes fade after 10–15 sec of continuous stimulation. 11. All phosphenes move proportionately with voluntary eye movements, within the accuracy of our mapping techniques. 12. Brightness modulation can easily be achieved by changing pulse amplitude. 13. The position of phosphenes in the visual field corresponds only roughly with expectations based on classical maps showing the projection of the visual field onto the cortex. 14. Patients can usually discriminate phosphenes produced by 1 mm 2 electrodes on 3 mm centres, although this seems to be close to the limit of resolution. 15. Patterns of up to four phosphenes produced by four electrodes have been recognized. However, a variety of complex interactions have been reported. 16. Multiple phosphenes are co‐planar, although patients are unable to estimate their distance. 17. Phosphenes appear immediately when stimulation is begun, and disappear immediately upon cessation of stimulation. 18. Future work must concentrate on blind volunteers to explore possible differences in subjective sensation produced after prolonged blindness, and to explore more complex pattern presentation which requires substantial periods of time with any given patient.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Furthermore, in contrast to the assumptions of our model, interactions between simultaneous stimulation of multiple electrodes can have an effect on the phosphene size and sometimes lead to unexpected percepts (Fernández et al., 2021; Dobelle and Mladejovsky, 1974; Bak et al., 1990).”
From Towards biologically plausible phosphene simulation for the differentiable optimization of visual cortical prostheses (2024) · cites this paper as Dobelle and Mladejovsky, 1974
In the citing paper
“They showed that visual percepts (phosphenes) could be evoked by electrical stimulation of the visual cortex via an array of electrodes implanted on the surface of a subject's visual cortex.”
From Visual percepts evoked with an intracortical 96-channel microelectrode array inserted in human occipital cortex (2021) · cites this paper as [4]
In the citing paper
“This 2-point resolution is closer than the 500 μ m resolution reported previously with a single electrode pair of gold wire electrodes (10), and about 5 times closer than has been achieved with surface electrodes (2-5, 7).”
From Visual percepts evoked with an intracortical 96-channel microelectrode array inserted in human occipital cortex (2021) · cites this paper as [4]
In the citing paper
“However, there were also some problems, such as the induction of epileptic seizures and the appearance of pain due to meningeal or scalp stimulation.”
From Toward Long-Term Communication With the Brain in the Blind by Intracortical Stimulation: Challenges and Future Prospects (2020) · cites this paper as Dobelle and Mladejovsky, 1974
In the citing paper
“Increasing the electrode density increases the risk of having a stimulation cross-talk and current summation when neighbouring electrodes are activated simultaneously.”
From Three-dimensional multilayer concentric bipolar electrodes restrict spatial activation in optic nerve stimulation (2022) · cites this paper as [7]
Citations
Cites
Wiesel, T. N., & Hubel, D. H. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.6.1029 · Cited by 1,598
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
The topography and variability of the primary visual cortex in man
Stensaas, S. S., Eddington, D. K., & Dobelle, W. H. (1974) · Journal of neurosurgery · doi:10.3171/jns.1974.40.6.0747 · Cited by 420
Self-citationLibet, B., Alberts, W. W., Wright, E. W., Delattre, L. D., Levin, G., & FEINSTEIN, B. (1964) · Journal of Neurophysiology · doi:10.1152/jn.1964.27.4.546 · Cited by 319
Structural changes in the area striata of the mouse after enucleation
Valverde, F. (1968) · Experimental Brain Research · doi:10.1007/bf00235903 · Cited by 286
The decline of potassium permeability during extreme hyperpolarization in frog skeletal muscle
Almers, W. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009929 · Cited by 135
The variability of the human striate cortex.
Gs, B. (1972) · PubMed · Cited by 93
A Prosthesis for the Deaf Based on Cortical Stimulation
Dobelle, W. H., Stensaas, S. S., Mladejovsky, M. G., & Smith, J. B. (1973) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348947308200404 · Cited by 83
Self-citationExperimental visual prosthesis
Donaldson, P. E. K. (1973) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1973.0061 · Cited by 58
Brindley, G. S. (1970) · PubMed Central · Cited by 38
Flagged first, then by citations
Cited by
Sorted by citations
Items 201–300 of 470
Tehovnik, E. J., Slocum, W. M., & Schiller, P. H. (2005) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2005.04454.x · Cited by 19
Li, W. (2009) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/amk6-ta42 · Cited by 19
Cai, C., Li, L., Li, X., Chai, X., Sun, J., Lu, Y., Sui, X., Chen, P., & Ren, Q. (2008) · Documenta Ophthalmologica · doi:10.1007/s10633-008-9157-2 · Cited by 18
Mechanisms of phosphenes in irradiated patients
Mathis, T., Vignot, S., Leal, C., Caujolle, J., Maschi, C., Mauget‐Faÿsse, M., Kodjikian, L., Baillif, S., Hérault, J., & Thariat, J. (2017) · Oncotarget · doi:10.18632/oncotarget.18719 · Cited by 19
An Animal Model of Auditory Cortex Prostheses
Scheich, H., & Breindl, A. (2002) · Audiology and Neurotology · doi:10.1159/000058309 · Cited by 18
A Survey of Vision Aids for the Blind
Liu, J., & Sun, X. (2006) · World Congress on Intelligent Control and Automation · doi:10.1109/wcica.2006.1713189 · Cited by 17
Excitation of visual cortex neurons by local intracortical microstimulation
Ronner, S. F., & Lee, B. G. (1983) · Experimental Neurology · doi:10.1016/0014-4886(83)90270-4 · Cited by 18
Normann, R. A., Campbell, P. K., & Jones, K. E. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1991.114805 · Cited by 18
Reading Pixelized Paragraphs of Chinese Characters Using Simulated Prosthetic Vision
Zhao, Y., Lü, Y., Zhao, J., Wang, K., Ren, Q., Wu, K., & Chai, X. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-5293 · Cited by 18
Tiwari, A., & Talwekar, R. H. (2018) · IETE Journal of Research · doi:10.1080/03772063.2017.1417750 · Cited by 17
Troyk, P. R., & Cogan, S. F. (2007) · Springer eBooks · doi:10.1007/0-306-48610-5_1 · Cited by 17
In defense of type materialism
Hill, C. S. (1984) · Synthese · doi:10.1007/bf00869337 · Cited by 17
Neural stimulation: Clinical and laboratory experiences
Pudenz, R. H. (1993) · Surgical Neurology · doi:10.1016/0090-3019(93)90190-c · Cited by 17
Microstimulation of V1 delays visually guided saccades: a parametric evaluation of delay fields
Tehovnik, E. J., & Slocum, W. M. (2006) · Experimental Brain Research · doi:10.1007/s00221-006-0625-1 · Cited by 17
Kim, C., & Wise, K. D. (1997) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.634656 · Cited by 17
Neurophysiological considerations for visual implants
Meikle, S. J., & Wong, Y. T. (2022) · Brain Structure and Function · doi:10.1007/s00429-021-02417-2 · Cited by 15
Paraskevoudi, N., & Pezaris, J. S. (2021) · Scientific Reports · doi:10.1038/s41598-021-86996-4 · Cited by 16
Song, X., Qiu, S., Shivdasani, M. N., Zhou, F., Liu, Z., Ma, S., Chai, X., Chen, Y., Cai, X., Guo, T., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5b18 · Cited by 17
Recognition of Objects in Simulated Irregular Phosphene Maps for an Epiretinal Prosthesis
Lü, Y., Wang, J., Wu, H., Li, L., Cao, X., & Chai, X. (2013) · Artificial Organs · doi:10.1111/aor.12174 · Cited by 16
Current Status of Artificial Vision by Electrocortical Stimulation
Girvin, J. P. (1988) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100027207 · Cited by 16
Functional reorganization of primary visual cortex induced by electrical stimulation in the cat
Warren, D. J., & Normann, R. A. (2004) · Vision Research · doi:10.1016/j.visres.2004.09.021 · Cited by 16
The Neuronal Basis of Motion Perception
Newsome, W. T., & Salzman, C. D. (2007) · Novartis Foundation symposium · doi:10.1002/9780470514412.ch11 · Cited by 16
Estimating Phosphene Locations Using Eye Movements of Suprachoroidal Retinal Prosthesis Users
Titchener, S. A., Goossens, J., Kvansakul, J. G. S., Nayagam, D. A. X., Kolic, M., Baglin, E. K., Ayton, L. N., Abbott, C. J., Luu, C. D., Barnes, N. M., et al. (2023) · Translational Vision Science & Technology · doi:10.1167/tvst.12.3.20 · Cited by 15
Gene-agnostic approaches to treating inherited retinal degenerations
Chew, L. A., & Iannaccone, A. (2023) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2023.1177838 · Cited by 16
Central nervous system microstimulation: Towards selective micro-neuromodulation
Urdaneta, M. E., Koivuniemi, A. S., & Otto, K. J. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.012 · Cited by 16
A penetrating, cortical electrode array: design considerations
Normann, R. A. (2002) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.1990.142258 · Cited by 15
Surface stimulation of the brain with a prototype array for a visual cortex prosthesis
Chowdhury, V., Morley, J. W., & Coroneo, M. T. (2004) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2003.12.010 · Cited by 15
Electrical Microstimulation of Visual Cerebral Cortex Elevates Psychophysical Detection Thresholds
Cone, J. J., Ni, A. M., Ghose, K., & Maunsell, J. H. R. (2018) · eneuro · doi:10.1523/eneuro.0311-18.2018 · Cited by 13
Rules governing perception of multiple phosphenes by human observers
Bosking, W., Foster, B., Sun, P., Beauchamp, M., & Yoshor, D. (2018) · doi:10.1101/302547 · Cited by 11
Visual cortical prosthesis: an electrical perspective
Pio‐Lopez, L., Poulkouras, R., & Depannemaecker, D. (2021) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2021.1907468 · Cited by 15
Mechanisms of electrical stimulation in eye diseases: A narrative review
Liu, J., Andre, K. H., So, K., Lee, V. W. H., & Chiu, K. (2022) · Advances in Ophthalmology Practice and Research · doi:10.1016/j.aopr.2022.100060 · Cited by 14
Lohmann, T., Kanda, H., Morimoto, T., Endo, T., Miyoshi, T., Nishida, K., Kamei, M., Walter, P., & Fujikado, T. (2015) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-015-3104-1 · Cited by 14
Intracortical Microstimulation Parameters Dictate the Amplitude and Latency of Evoked Responses
Watson, M., Dancause, N., & Sawan, M. (2015) · Brain stimulation · doi:10.1016/j.brs.2015.10.008 · Cited by 17
Microstimulation of V1 affects the detection of visual targets: manipulation of target contrast
Tehovnik, E. J., & Slocum, W. M. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-2306-x · Cited by 14
Assessing the efficacy of visual prostheses by decoding ms-LFPs: application to retinal implants
Cottaris, N. P., & Elfar, S. D. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026007 · Cited by 14
Improvement in reading performance through training with simulated thalamic visual prostheses
Rassia, K. E. K., & Pezaris, J. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-31435-0 · Cited by 13
The impact of synchronous versus asynchronous electrical stimulation in artificial vision
Moleirinho, S., Whalen, A. J., Fried, S. I., & Pezaris, J. S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abecf1 · Cited by 14
Psychophysics testing of bionic vision image processing algorithms using an FPGA Hatpack
Josh, H., Mann, C., Kleeman, L., & Lui, W. L. D. (2013) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2013.6738319 · Cited by 13
A REVIEW OF RETINAL PROSTHESIS APPROACHES
Kiên, T. T., Maul, T., & Andrzej Bargiela, A. (2012) · International Journal of Modern Physics Conference Series · doi:10.1142/s2010194512005272 · Cited by 13
Phosphene Mapping Techniques for Visual Prostheses
Stronks, H. C., & Dagnelie, G. (2011) · Springer eBooks · doi:10.1007/978-1-4419-0754-7_19 · Cited by 13
[Electrical stimulation of the visual system. From empirical approach to visual prostheses].
Uhlig, C. E., Taneri, S., Benner, F. P., & Gerding, H. (2001) · PubMed · doi:10.1007/s003470170031 · Cited by 15
Intracortical microstimulation of neurons in the visual cortex of the cat
Ronner, S. F., Foote, W. E., & Pollen, D. A. (1981) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(81)90067-5 · Cited by 13
Postmortem investigation of a human cortical visual prosthesis that was implanted for 36 years
Towle, V. L., Pytel, P., Lane, F., Plass, J., Frim, D. M., & Troyk, P. R. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9d11 · Cited by 11
Monte Carlo simulation of quantum Zeno effect in the brain
Georgiev, D. D. (2014) · International Journal of Modern Physics B · doi:10.1142/s0217979215500393 · Cited by 12
Learning to Recognize Visual Objects With Microstimulation in Inferior Temporal Cortex
Kawasaki, K., & Sheinberg, D. L. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90247.2008 · Cited by 12
Study of Tactile Perception Based on Phosphene Positioning Using Simulated Prosthetic Vision
Chai, X., Zhang, L., Li, W., Shao, F., Yang, K., & Ren, Q. (2007) · Artificial Organs · doi:10.1111/j.1525-1594.2007.00469.x · Cited by 12
Normann, R. A., Campbell, P. K., & Li, W. P. (1988) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1988.94953 · Cited by 12
Borda, E., Gaillet, V., Airaghi Leccardi, M. J. I., Zollinger, E. G., Moreira, R. C., & Ghezzi, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6d7e · Cited by 11
A Mixed Integer Linear Programming Approach to Electrical Stimulation Optimization Problems
Abouelseoud, G., Abouelseoud, Y., Shoukry, A., Ismail, N. E., & Mekky, J. F. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2789380 · Cited by 11
Lane, F. J., Nitsch, K. P., & Troyk, P. R. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146610 · Cited by 11
Miyamoto, S., Suematsu, N., Umehira, Y., Hayashida, Y., & Yagi, T. (2017) · Scientific Reports · doi:10.1038/s41598-017-14303-1 · Cited by 11
Four technologies that could transform the treatment of blindness
Makin, S. J. (2019) · Nature · doi:10.1038/d41586-019-01107-8 · Cited by 11
Toward the development of a color visual prosthesis
Towle, V. L., Pham, T. D., McCaffrey, M., Allen, D., & Troyk, P. R. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd520 · Cited by 10
Transkorneale Elektrostimulation bei Patienten mit Morbus Stargardt
Röck, T., Schatz, A., Naycheva, L., Gosheva, M., Pach, J., Wilhelm, B., Peters, T. M., Bartz‐Schmidt, K. U., Zrenner, E., Willmann, G., et al. (2013) · Der Ophthalmologe · doi:10.1007/s00347-012-2749-y · Cited by 11
Perspectives of optic nerve prostheses
Lane, F. J., Nitsch, K. P., HUYCK, M. H., Troyk, P. R., & Schug, K. (2014) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2014.961178 · Cited by 11
Srivastava, N., & Troyk, P. R. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259987 · Cited by 11
Humayun, M. S., & Lee, S. Y. (2022) · Ophthalmology Retina · doi:10.1016/j.oret.2022.04.009 · Cited by 10
Thalamic Visual Prosthesis Project
Kyada, M. J., Killian, N. J., & Pezaris, J. S. (2016) · Springer eBooks · doi:10.1007/978-3-319-41876-6_14 · Cited by 10
Silicon Valley new focus on brain computer interface: hype or hope for new applications?
Mitrasinovic, S., Brown, A. P. Y., Schaefer, A. T., Chang, S. D., & Appelboom, G. (2018) · F1000Research · doi:10.12688/f1000research.15726.1 · Cited by 10
Current Status of Research on Providing Sight to the Blind by Electrical Stimulation of the Brain
Dobelle, W. H. (1977) · Journal of Visual Impairment & Blindness · doi:10.1177/0145482x7707100702 · Cited by 10
Self-citationde Ruyter van Steveninck, J., Nipshagen, M., van Gerven, M., Güçlü, U., Güçlüturk, Y., & van Wezel, R. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad357d · Cited by 8
Local field potential phase modulates neural responses to intracortical electrical stimulation
Allison-Walker, T. J., Ann Hagan, M., Chiang Price, N. S., & Tat Wong, Y. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176186 · Cited by 9
Grani, F., Soto‐Sánchez, C., Doblado, A. R., López-Peco, R., González-López, P., & Fernández, E. (2025) · Science Advances · doi:10.1126/sciadv.adv8846 · Cited by 10
Neural mechanisms underlying intracortical microstimulation for sensory restoration
Hughes, C. L., Chen, X., Grill, W. M., & Kozai, T. D. Y. (2026) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01583-6 · Cited by 11
Raising the stakes for cortical visual prostheses
Beauchamp, M. S., Bosking, W. H., Oswalt, D. N., & Yoshor, D. (2021) · Journal of Clinical Investigation · doi:10.1172/jci154983 · Cited by 9
Rat behavioral model for high-throughput parametric studies of intracortical microstimulation
Koivuniemi, A. S., Regele, O. B., Brenner, J. H., & Otto, K. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091859 · Cited by 9
Muramatsu, S., Toda, M., Nishikawa, J., & Tateno, T. (2019) · Brain Research · doi:10.1016/j.brainres.2019.146312 · Cited by 8
Vanishing senses—restoration of sensory functions by electronic implants
Rosahl, S. K. (2004) · Poiesis & Praxis · doi:10.1007/s10202-003-0057-y · Cited by 9
Design considerations for the brain-machine interface
Joseph, A. B. (1985) · Medical Hypotheses · doi:10.1016/0306-9877(85)90124-0 · Cited by 9
Multichannel surface recordings on the visual cortex: implications for a neuroprosthesis
Chelvanayagam, D. K., Vickery, R. M., Kirkcaldie, M., Coroneo, M. T., & Morley, J. W. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/003 · Cited by 9
Tehovnik, E. J., & Slocum, W. M. (2009) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2009.06810.x · Cited by 8
An Image Processing Approach for Blind Mobility Facilitated Through Visual Intracortical Stimulation
Mohammadi, H. M., Ghafar‐Zadeh, E., & Sawan, M. (2012) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01421.x · Cited by 8
Augmentation of Sensorimotor Functions with Neural Prostheses
Lebedev, M. (2016) · Russian Agency for Digital Standardization · doi:10.20388/omp2016.003.0035 · Cited by 8
Transkorneale Elektrostimulation bei primärem Offenwinkelglaukom
Röck, T., Naycheva, L., Willmann, G., Wilhelm, B., Peters, T. M., Zrenner, E., Bartz‐Schmidt, K. U., Gekeler, F., & Schatz, A. (2016) · Der Ophthalmologe · doi:10.1007/s00347-016-0415-5 · Cited by 8
Activation of single cells in cat visual cortex by electrical stimulation of the cortical surface
Ronner, S. F., Foote, W. E., & Feldon, S. E. (1980) · Experimental Neurology · doi:10.1016/0014-4886(80)90005-9 · Cited by 8
FPGA based visual prosthesis device for testing visual perception on non human primates
Srivastava, N., Troyk, P. R., & Bradley, D. (2007) · IEEE International Conference on Electro Information Technology · doi:10.1109/eit.2007.4374463 · Cited by 8
van der Grinten, M., de Ruyter van Steveninck, J., Lozano, A., Pijnacker, L., Rückauer, B., Roelfsema, P., van Gerven, M., van Wezel, R., Güçlü, U., & Güçlütürk, Y. (2022) · doi:10.1101/2022.12.23.521749 · Cited by 39
BRAIN-COMPUTER INTERFACE FOR THE AUGMENTATION OF BRAIN FUNCTIONS
Lebedev, M. (2016) · Science and Innovations in Medicine · doi:10.35693/2500-1388-2016-0-3-11-27 · Cited by 7
Cortical layering disrupts multi-electrode current steering
Meikle, S. J., Hagan, M. A., Price, N. S. C., & Wong, Y. T. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acdaf7 · Cited by 7
Visual Prostheses: Neuroengineering Handbook
Guo, T., Shivdasani, M. N., Tsai, D., Ayton, L. N., Rathbun, D. L., & Lovell, N. H. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_31-2 · Cited by 7
Lee, S. W., & Fried, S. I. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0019 · Cited by 5
Introduction to Visual Prostheses
Fernández, E., & Normann, R. A. (2016) · Europe PMC (PubMed Central) · Cited by 7
A proposed intracortical visual prosthesis image processing system
Srivastava, N., & Troyk, P. R. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1615667 · Cited by 7
Interfacing microsystems and biological systems
Dario, P., & Carrozza, M. C. (2002) · International Symposium on Micro-NanoMechatronics and Human Science · doi:10.1109/mhs.1995.494219 · Cited by 7
Development and Experimental Basis for the Future of Prosthetic Vision
Allen, P. J., & Ayton, L. N. (2020) · Springer eBooks · doi:10.1007/978-981-15-7644-7_33 · Cited by 6
Hernández-Sebastián, N., Carpio-Verdín, V. M., Ambriz-Vargas, F., Morales-Morales, F., Lara, A. B., Buenrostro-Jáuregui, M. H., Bojorges-Valdez, E., & Barrientos-García, B. (2023) · Micromachines · doi:10.3390/mi14111999 · Cited by 6
The Bionic Eye: Retinal Prostheses
Park, R. I. (2004) · International Ophthalmology Clinics · doi:10.1097/00004397-200404440-00011 · Cited by 6
Lee, S. W. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3033491 · Cited by 7
Hayashida, Y., Umehira, Y., Takatani, K., Shigetoshi, F., Kameda, S., Kamata, T., Khan, A. U., Takeuchi, Y., Imai, M., & Yagi, T. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318690 · Cited by 6
Dispersion and Accuracy of Simulated Phosphene Positioning Using Tactile Board
Zhang, L., Chai, X., Ling, S., Fan, J., Yang, K., & Ren, Q. (2009) · Artificial Organs · doi:10.1111/j.1525-1594.2009.00826.x · Cited by 6
Applications of neural control in humans
Hambrecht, F. T. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363436 · Cited by 6
Evaluation of micro-electrocorticographic electrodes for electrostimulation
Wilks, S. J., Koivuniemi, A. S., Thongpang, S., Williams, J. C., & Otto, K. J. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333178 · Cited by 6
Commentary: Injecting Instructions into Premotor Cortex
Lebedev, M., & Ossadtchi, A. E. (2018) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2018.00065 · Cited by 6
Grill, W. M., & Kirsch, R. F. (1999) · Wiley eBooks · doi:10.1002/047134608x.w1424 · Cited by 6
Bayesian optimization of cortical neuroprosthetic vision using perceptual feedback
Küçükoğlu, B., Soo, L., Leeftink, D., Grani, F., Soto‐Sánchez, C., Güçlü, U., van Gerven, M. A. J., & Fernández, E. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adeae9 · Cited by 5
Yang, G., Pang, B., Gong, H., Qiu, Y., Gong, C., Zhou, S., Zheng, Q., Wang, Z., Bu, T., Xu, S., et al. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2533145123 · Cited by 5
Threshold analysis of a quasimonopolar stimulation paradigm in visual prosthesis
Matteucci, P. B., Chen, S. C., Dodds, C. W. D., DokosNigel, S., Lovell, N. H., & Suaning, G. J. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346594 · Cited by 5
Saliency-guided neural prosthesis for visual attention: Design and simulation
Yoshida, M., & Veale, R. (2013) · Neuroscience Research · doi:10.1016/j.neures.2013.07.007 · Cited by 5
Rock Art and the Neurovisual Bases of Subjective Visual Phenomena
Watson, B. (2012) · Time and Mind · doi:10.2752/175169712x13276628335168 · Cited by 5
The Use of Electrotherapeutics in Ophthalmology
Luu, K.-Y., Zhao, M., & Mannis, M. J. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2019.11.011 · Cited by 5
Metadata
- Authors
- Dobelle, W. H., & Mladejovsky, M. G.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1974-12
- Volume
- 243
- Issue
- 2
- Pages
- 553-576
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- PMC
- PMC1330721
- OpenAlex
- W2018103408
- Cited by
- 468
- References
- 11
- Citations by year
- 2026: 12 · 2025: 12 · 2024: 7 · 2023: 14 · 2022: 20 · 2021: 16 · 2020: 19 · 2019: 11 · 2018: 17 · 2017: 11 · 2016: 19 · 2015: 17 · 2014: 15 · 2013: 25 · 2012: 22
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Keywords
- phosphenes, visual prosthesis, visual cortex stimulation, occipital lobe, blind patients, area 17, electrode configuration, stimulation threshold, brightness modulation, electrode spacing, hemianopia
- MeSH terms
- Adult, Aged, Arteriovenous Malformations, Astrocytoma, Blindness, Electric Stimulation, Electrodes, Eye Movements, Female, Humans, Male, Meningioma, Methods, Middle Aged, Occipital Lobe, Pain, Pulse, Vision, Ocular, Visual Cortex, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review