Frequency Analysis of the Tuned Mass Damper
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The damping properties of the viscous tuned mass damper are characterized by dynamic amplification analysis as well as identification of the locus of the complex natural frequencies. Optimal damping is identified by a combined analysis of the dynamic amplification of the motion of the structural mass as well as the relative motion of the damper mass. The resulting optimal damper parameter is about 15% higher than the classic value, and results in improved properties for the motion of the damper mass. The free vibration properties are characterized by analyzing the locus of the natural frequencies in the complex plane. It is demonstrated that for optimal frequency tuning the damping ratio of both vibration modes are equal and approximately half the damping ratio of the applied damper, when the damping is below a critical value corresponding to a bifurcation point. This limiting value corresponds to maximum modal damping and serves as an upper limit for damping to be applied in practice.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Optimum absorber parameters for various combinations of response and excitation parameters
Warburton, G. B. (1982) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290100304 · Cited by 1,043
Passive energy dissipation systems in structural engineering
Crewe, A. (1998) · Structural Safety · doi:10.1016/s0167-4730(97)00034-9 · Cited by 1,015
Passive Energy Dissipation Systems in Structural Engineering
Dargush, G. F., & Soong, T. T. (1997) · Medical Entomology and Zoology · Cited by 880
The Theory of the Dynamic Vibration Absorber
Ormondroyd, J., & Den Hartog, J. P. (1928) · Transactions of the American Society of Mechanical Engineers · doi:10.1115/1.4058553 · Cited by 779
Asami, T., Nishihara, O., & Baz, A. M. (2002) · Journal of Vibration and Acoustics · doi:10.1115/1.1456458 · Cited by 405
A Note on the Damped Vibration Absorber
Brock, J. E. (1946) · Journal of Applied Mechanics · doi:10.1115/1.4009588 · Cited by 356
Richards, K. L. (2017) · CRC Press eBooks · doi:10.1201/9781315367514-9 · Cited by 88
Cited by
Marian, L., & Giaralis, A. (2014) · Probabilistic Engineering Mechanics · doi:10.1016/j.probengmech.2014.03.007 · Cited by 828
“Further, a semi-empirical “optimum” design procedure has been established by Den Hartog [3] and Brock [4] to “tune” the damping and stiffness properties for an a priori specified mass of this spring-mass-damper attachment such that the peak displacement of harmonically excited undamped SDOF primary structures is minim…”
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
“A frequency analysis of the TMD system as studied by Krenk (2005) , wherein it was demonstrated that he classic frequency tuning leads to equal damping ratio of the wo vibration modes of the combined system.”
MethodVibration suppression of structures using tuned mass damper technology: A state-of-the-art review
Yang, F., Sedaghati, R., & Esmailzadeh, E. (2022) · Journal of Vibration and Control · doi:10.1177/1077546320984305 · Cited by 306
“Krenk (2005) presented the frequency analysis of the TMD system to realize the effectiveness of the TMD system.”
BackgroundOffshore Wind Turbine Load Reduction Employing Optimal Passive Tuned Mass Damping Systems
Stewart, G., & Lackner, M. (2013) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2013.2260825 · Cited by 219
“Even for an idealized one-degree-of-freedom structure, the optimal tuning for the spring and damper is dictated by a complex function [18].”
BackgroundPassive non-linear targeted energy transfer and its applications to vibration absorption: A review
Lee, Y. S., Vakakis, A. F., Bergman, L. A., McFarland, D. M., Kerschen, G., Nucera, F., Tsakirtzis, S., & Panagopoulos, P. N. (2008) · Proceedings of the Institution of Mechanical Engineers, Part K: Journal of Multi-body Dynamics · doi:10.1243/14644193jmbd118 · Cited by 157
Marian, L., & Giaralis, A. (2017) · City Research Online (City University London) · doi:10.12989/sss.2017.19.6.665 · Cited by 131
“…equipped with the classical TMD are applicable for the TMDI as well: one needs only to replace the attached TMD mass, by the sum of the attached mass and the inertance, as required in the various expressions derived for the classical TMD (e.g., Den Hartog 1956, Krenk 2005, Salvi and Rizzi 2016).”
InfluentialStructural control and vibration issues in wind turbines: A review
Xie, F., & Aly, A.-M. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2019.110087 · Cited by 159
Zilletti, M., Elliott, S. J., & Rustighi, E. (2012) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2012.04.023 · Cited by 158
“4 H∞ Minimisation of relative displacement A1max = x1 xst max A2max = x1 − x2 xst max Minimisation of displacement of the main mass and relative displacement Krenk 2005 [17] ζopt = μ 2(1 + μ)”
BackgroundMethodCables interconnected with tuned inerter damper for vibration mitigation
Sun, L., Hong, D., & Chen, L. (2017) · Engineering Structures · doi:10.1016/j.engstruct.2017.08.009 · Cited by 152
Nonlinear magnetic vibration absorber for passive control of a multi–storey structure
Lo Feudo, S., Touzé, C., Boisson, J., & Cumunel, G. (2019) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2018.09.007 · Cited by 136
Closed-form solutions for the optimal design of inerter-based dynamic vibration absorbers
Barredo, E., Ortega, A. B., Colín-Ocampo, J., Penagos, V. M., Abúndez‐Pliego, A., Valdés, L. G. V., Meza, V., Cruz, R. H., & Mayén, J. (2018) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2018.05.025 · Cited by 140
Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Rahimi, F., Aghayari, R., & Samali, B. (2020) · Civil Engineering Journal · doi:10.28991/cej-2020-03091571 · Cited by 138
“A frequency analysis of the TMD system was studied by [36, 37], wherein it displayed that the ancient frequency tuning causes to equal damping ratio of the two vibration modes of the Hybrid system.”
BackgroundActive tuned mass damper for damping of offshore wind turbine vibrations
Brodersen, M. L., Bjørke, A.-S., & Høgsberg, J. (2016) · Wind Energy · doi:10.1002/we.2063 · Cited by 135
“Together with the expression in (19) the expression above in (26) gives the optimum frequency and damper tuning for the ATMD, while for gk = gc = 0 the optimum frequency and damper tuning of the passive TMD is recovered [25].”
BackgroundResultInfluentialTuned mass-damper-inerter (TMDI) for suppressing edgewise vibrations of wind turbine blades
Zhang, Z., & Fitzgerald, B. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2020.110928 · Cited by 132
“Optimal frequency tuning According to the classical TMD theory [7, 11], around ω0 there are two excitation frequencies ωM and ωN where the dynamic amplifications are independent of the TMD damping ratio ζd.”
BackgroundMethodOptimal configurations for a linear vibration suppression device in a multi-storey building
Zhang, S. Y., Jiang, J. Z., & Neild, S. (2017) · Structural Control and Health Monitoring · doi:10.1002/stc.1887 · Cited by 123
“The classical method of choosing the damping ratio is based on the tuning method proposed by Den-Hartog [4] and others [5–8], and Krenk characterised the damping properties of the TMD and identified the optimal damping by analysing the motion of the structural mass as well as the relative motion of the damper mass in…”
MethodTuned mass absorber on a flexible structure
Krenk, S., & Høgsberg, J. (2013) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2013.11.029 · Cited by 123
Self-citationTuned mass absorbers on damped structures under random load
Krenk, S., & Høgsberg, J. (2008) · Probabilistic Engineering Mechanics · doi:10.1016/j.probengmech.2007.04.004 · Cited by 115
Self-citationZhang, Z., Chen, J., & Li, J. (2013) · Structure and Infrastructure Engineering · doi:10.1080/15732479.2013.792098 · Cited by 109
“By linearising the equation of motion of the BVAstructure integrated system, the parametric optimisation of this damping device could be carried out based on the well-known optimisation procedures for the TMD (Den Hartog, 1956; Krenk, 2005).”
MethodInfluentialWeber, F., Boston, C., & Maślanka, M. (2011) · Smart Materials and Structures · doi:10.1088/0964-1726/20/1/015012 · Cited by 97
Krenk, S., & Høgsberg, J. (2016) · Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.2015.0718 · Cited by 91
Self-citationImproved inerter-based vibration absorbers
Alotta, G., & Failla, G. (2020) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2020.106087 · Cited by 92
Kong, X., Li, H., & Wu, C. (2017) · Nonlinear Dynamics · doi:10.1007/s11071-017-3906-2 · Cited by 90
Tuned Mass Damper optimization for the mitigation of human-induced vibrations of pedestrian bridges
Tubino, F., & Piccardo, G. (2014) · Meccanica · doi:10.1007/s11012-014-0021-z · Cited by 77
“More recently, Krenk [12] identified optimum damping by a combined analysis of the dynamic amplification of the motion of the structure as well as the relative motion of the damper.”
BackgroundMethodInfluentialSuppression of vortex-induced high-mode vibrations of a cable-damper system by an additional damper
Di, F., Sun, L., & Chen, L. (2021) · Engineering Structures · doi:10.1016/j.engstruct.2021.112495 · Cited by 73
Nagarajaiah, S., Chen, L., & Wang, M. (2022) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0003472 · Cited by 72
The optimal design of dynamic systems with negative stiffness inertial amplifier tuned mass dampers
Chowdhury, S., Banerjee, A., & Adhikari, S. (2022) · Applied Mathematical Modelling · doi:10.1016/j.apm.2022.10.011 · Cited by 67
Dynamic analogy between an electromagnetic shunt damper and a tuned mass damper
Zhu, S., Shen, W., & Qian, X. (2013) · Smart Materials and Structures · doi:10.1088/0964-1726/22/11/115018 · Cited by 66
“Krenk (2005) proved that the optimal frequency enables the two complex loci of natural frequencies to meet at a bifurcation point.”
BackgroundTwelve Lectures on Structural Dynamics
Preumont, A. J. (2013) · Solid mechanics and its applications · doi:10.1007/978-94-007-6383-8 · Cited by 64
Passive vibration control: a structure–immittance approach
Zhang, S. Y., Jiang, J. Z., & Neild, S. A. (2017) · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rspa.2017.0011 · Cited by 63
Optimal tuning of the tuned mass damper (TMD) for rotating wind turbine blades
Zhang, Z. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2020.110209 · Cited by 63
Load Reduction of Floating Wind Turbines using Tuned Mass Dampers
Stewart, G. M. (2012) · Scholarworks (University of Massachusetts Amherst) · doi:10.7275/2232309 · Cited by 63
Closed-form formulas for the optimal pole-based design of tuned mass dampers
Bisegna, P., & Caruso, G. (2012) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2012.01.005 · Cited by 60
Tumkur, R. K. R., Calderer, R., Masud, A., Pearlstein, A. J., Bergman, L. A., & Vakakis, A. F. (2013) · Journal of Fluids and Structures · doi:10.1016/j.jfluidstructs.2013.03.008 · Cited by 60
Feedback control unit with an inerter proof-mass electrodynamic actuator
Zilletti, M. (2016) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2016.01.035 · Cited by 59
Balanced calibration of resonant shunt circuits for piezoelectric vibration control
Høgsberg, J., & Krenk, S. (2012) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x12455727 · Cited by 52
“The design procedure is inspired by the analysis in Krenk (2005) for the mechanical tuned mass damper.”
BackgroundMethodSelf-citationCalibration of piezoelectric RL shunts with explicit residual mode correction
Høgsberg, J., & Krenk, S. (2016) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2016.08.028 · Cited by 51
“The tuning of resonant dampers dates back to the analysis of the mechanical tuned mass damper [7], for which the classic frequency response calibration based on identical amplitudes at two neutral frequencies implies equal damping of the two modes associated with the targeted vibration form, [8].”
BackgroundInfluentialSelf-citationSeismic protection of land-based wind turbine towers using the tuned inerter damper
Alotta, G., Biondo, C., Giaralis, A., & Failla, G. (2023) · Structures · doi:10.1016/j.istruc.2023.03.004 · Cited by 50
Parameter optimization and structural design of tuned mass damper for shanghai centre tower
Lü, X., & Chen, J. (2010) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.649 · Cited by 50
“Deriving analytical formulas of optimal system parameters have been studied in Bakrez and Jangid (2007), Krenk (2005) and Soong et al. (1997), etc.”
MethodZhang, Z., & Larsen, T. G. (2020) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2020.115827 · Cited by 50
A nonlinear piezoelectric shunt absorber with a 2:1 internal resonance: Theory
Shami, Z. A., Giraud-Audine, C., & Thomas, O. (2022) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.108768 · Cited by 50
Chatziathanasiou, G. M., Chrysochoidis, N. A., Rekatsinas, C. S., & Saravanos, D. A. (2022) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2022.117222 · Cited by 49
Generalization of the Den Hartog model and rule-of-thumb formulas for optimal tuned mass dampers
Argenziano, M., Faiella, D., Carotenuto, A. R., Mele, E., & Fraldi, M. (2022) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2022.117213 · Cited by 47
Optimized design of multiple tuned mass dampers for vibration control of offshore wind turbines
McNamara, D. A., Pandit, A. R., & Malekjafarian, A. (2024) · Ocean Engineering · doi:10.1016/j.oceaneng.2024.117912 · Cited by 47
Auto-parametric semi-trivial and post-critical response of a spherical pendulum damper
Náprstek, J., & Fischer, C. (2009) · Computers & Structures · doi:10.1016/j.compstruc.2008.11.015 · Cited by 47
“Let us refer papers [4–6] where basic dynamics, frequency analysis and later optimization of the system and its response are discussed.”
BackgroundBerardengo, M., Cigada, A., Manzoni, S., & Vanali, M. (2015) · Shock and Vibration · doi:10.1155/2015/704265 · Cited by 46
“The first twomethodologies discussed here are based on standard tuning criteria ([29, 30]) for the TMDdevices, while the third one is based on considerations on the shape ofTzw as function of the electrical damping ξp.”
BackgroundMethodResultInfluentialResonant Vibration Control of Three-Bladed Wind Turbine Rotors
Krenk, S., Svendsen, M. N., & Høgsberg, J. (2012) · AIAA Journal · doi:10.2514/1.j051164 · Cited by 46
Self-citationInvestigation and optimization of a pre‐stressed tuned mass damper for wind turbine tower
Liu, G., Lei, Z., & Wang, H. (2021) · Structural Control and Health Monitoring · doi:10.1002/stc.2894 · Cited by 45
“Consequently, the generated equivalent acceleration using Equation (27) will be centralized; that is, the mean will be removed, and thus, the mean of the final equivalent acceleration is zero.”
Zhang, Z. (2022) · Renewable Energy · doi:10.1016/j.renene.2022.08.121 · Cited by 45
DYNAMIC ANALYSIS OF STRUCTURES WITH MULTIPLE TUNED MASS DAMPERS
Lewandowski, R., & Grzymisławska, J. (2009) · Journal of Civil Engineering and Management · doi:10.3846/1392-3730.2009.15.77-86 · Cited by 45
“For example, in his excellent paper Krenk (2005) derived a new formula for the TMD optimal damping coefficient.”
Closed-form optimum tuning formulas for passive Tuned Mass Dampers under benchmark excitations
Salvi, J., & Rizzi, E. (2016) · Smart Structures and Systems · doi:10.12989/sss.2016.17.2.231 · Cited by 45
Closed-form optimal calibration of a tuned liquid column damper (TLCD) for flexible structures
Chen, B., Zhang, Z., & Hua, X. (2021) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2021.106364 · Cited by 44
“(16b) are reduced to the following second-order differential equations: which are exactly the EOMs of the classic SDOF-TLCD system (classic 2-DOF system with background flexibility ignored).”
BackgroundMethodResultInfluentialEqual modal damping design for a family of resonant vibration control formats
Krenk, S., & Høgsberg, J. (2012) · Journal of Vibration and Control · doi:10.1177/1077546312446796 · Cited by 44
“When using the special properties of the four roots illustrated in Figure 2, the following expression is obtained for the damping ratio (Krenk, 2005)”
BackgroundMethodSelf-citationClosed-form optimization of tuned mass-damper-inerter (TMDI) in flexible structures
Zhang, Z., Chen, B., & Hua, X. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.106554 · Cited by 43
Xu, S., Fang, G., Zhang, M., Øiseth, O. A., Zhao, L., & Ge, Y. (2023) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2023.110857 · Cited by 43
Richiedei, D., Tamellin, I., & Trevisani, A. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09583-w · Cited by 43
“[40] Primary mass displacement and the relative displacement f”
BackgroundEnhancement of a dynamic vibration absorber by means of an electromagnetic shunt
Auleley, M., Thomas, O., Giraud-Audine, C., & Mahé, H. (2020) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x20957097 · Cited by 42
“…fixed point method, analogous to the resistive case, for which two fixed point are obtained (labelled (F1,G1) for the DVA and (F2,G2) for the RCshunt in Figure 5) (Connor and Laflamme, 2014; Hartog, 1956; Inoue et al., 2008; Krenk, 2005; Liu and Liu, 2005; Thomas et al., 2012; Zhou et al., 2019).”
MethodOn the optimal design and robustness of spatially distributed tuned mass dampers
da Costa, M. M. A., Castello, D. A., Magluta, C., & Roitman, N. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.107289 · Cited by 42
Resonant inerter based vibration absorbers on flexible structures
Krenk, S. (2019) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2018.11.038 · Cited by 41
“The classic design procedure in terms of properties of the dynamic amplification curve was replaced by a root locus based procedure by Krenk [7], where it was demonstrated that the classic equal amplification of two fixed points is equivalent to two roots with equal damping, and the damping ratio was determined by a d…”
BackgroundMethodInfluentialSelf-citationTuned mass damper on a damped structure
Fang, H., Liu, L., Zhang, D., & Wen, M. (2019) · Structural Control and Health Monitoring · doi:10.1002/stc.2324 · Cited by 41
“H1 x ð Þ 0 1⁄4 0 ⇒ H1 x ð Þ j j(2) 0 1⁄4 2 H1 x ð Þ‖H1 x ð Þ j j 1⁄4 0: (21)”
On a combination of ground-hook controllers for semi-active tuned mass dampers
Viet, L. D., Nghi, N. B., Hieu, N. N., Hung, D. T., Linh, N. N., & Hung, L. X. (2014) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-014-0109-3 · Cited by 40
Høgsberg, J., & Krenk, S. (2014) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2014.12.006 · Cited by 40
“Details concerning the construction and form of this characteristic equation can be found in reference [26].”
BackgroundMethodInfluentialSelf-citationH2 optimal vibration control using inertial actuators and a comparison with tuned mass dampers
Alujević, N., Zhao, G., Depraetere, B., Sas, P., Pluymers, B., & Desmet, W. (2014) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2014.04.038 · Cited by 40
Sweeping shunted electro-magnetic tuneable vibration absorber: Design and implementation
Turco, E., & Gardonio, P. (2017) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2017.06.035 · Cited by 40
Larsen, T. G., Zhang, Z., & Høgsberg, J. (2021) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2021.116144 · Cited by 39
“263 The triple-root bifurcation point is associated with the maximum modal damping ratio attainable when the equal modal damping condition is fulfilled [34].”
BackgroundMethodInfluentialZhang, Z. (2021) · Engineering Structures · doi:10.1016/j.engstruct.2021.113524 · Cited by 38
Optimised semi-active tuned mass damper with acceleration and relative motion feedbacks
Maślanka, M. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.05.025 · Cited by 37
Linear control strategies for damping of flexible structures
Høgsberg, J., & Krenk, S. (2005) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2005.09.014 · Cited by 37
Self-citationLi, Y., Park, S., Jiang, J. Z., Lackner, M. A., Neild, S. A., & Ward, I. (2020) · Wind Energy · doi:10.1002/we.2544 · Cited by 35
Targeted energy transfer in a vibro-impact cubic NES: Description of regimes and optimal design
Wu, Z., Paredes, M., & Seguy, S. (2022) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2022.117425 · Cited by 34
Gardonio, P., & Turco, E. (2019) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2019.03.015 · Cited by 33
A two-degree-of-freedom tuned mass damper for offshore wind turbines on floating spar supports
Laface, V., Alotta, G., Failla, G., Ruzzo, C., & Arena, F. (2022) · Marine Structures · doi:10.1016/j.marstruc.2021.103146 · Cited by 32
Crane sway reduction using Coriolis force produced by radial spring and damper
Viet, L. D. (2015) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-015-0211-1 · Cited by 31
“In the present paper, the conditions of double poles [20, 21] are considered as the optimal conditions to obtain a closed form of the optimal parameters.”
MethodToftekær, J. F., Benjeddou, A., & Høgsberg, J. (2019) · Mechanics of Advanced Materials and Structures · doi:10.1080/15376494.2018.1549297 · Cited by 31
“For this, the principle of equal modal damping is applied; initially, the latter was introduced for the mecha nic l tuned mass damper in [19] and subsequently proposed for pole placement calibration of a r esonant series RL shunt [1].”
MethodSalvi, J., & Giaralis, A. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/744/1/012082 · Cited by 31
A semi-active shunted piezoelectric tuned mass damper for robust vibration control
Chatziathanasiou, G. M., Chrysochoidis, N. A., & Saravanos, D. A. (2021) · Journal of Vibration and Control · doi:10.1177/10775463211026487 · Cited by 30
“More recently, Høgsberg (2019) reported a theoretical investigation of the root loci of a 3-DOF system, consisting of a structural mass, the absorber mass, and an RL shunted ideal piezoelectric element, and used the principal of equal damping (Høgsberg and Krenk, 2012; Krenk, 2005) to determine the optimal parameters…”
BackgroundMethodOptimal calibration of a tuned liquid column damper (TLCD) for rotating wind turbine blades
Chen, B., Zhang, Z., Hua, X., & Basu, B. (2021) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2021.116565 · Cited by 30
A grounded inerter-based oscillating TMD for suppressing harmonic and random vibrations
Barredo, E., Zhao, Z., Mazón-Valadez, C., Mendoza-Larios, J. G., & Maldonado, I. A. (2023) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2023.108438 · Cited by 30
Zilletti, M., Gardonio, P., & Elliott, S. J. (2014) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2014.04.036 · Cited by 30
“2 of passive tuneable vibration absorbers have been proposed by many researchers and a vast literature can be found on this topic [2-12].”
BackgroundOptimal resonant control of flexible structures
Krenk, S., & Høgsberg, J. (2009) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2009.01.031 · Cited by 30
Self-citationClosed-form optimal design of the tuned inerter damper (TID) connecting adjacent flexible buildings
Zhang, Z., Li, X., Chen, B., & Hua, X. (2024) · Engineering Structures · doi:10.1016/j.engstruct.2023.117419 · Cited by 29
Piezoelectric-shunt-based approach for multi-mode adaptive tuned mass dampers
Manzoni, S., Berardengo, M., Boccuto, F., & Vanali, M. (2023) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2023.110537 · Cited by 28
Integrated tuned vibration absorbers: A theoretical study
Gardonio, P., & Zilletti, M. (2013) · The Journal of the Acoustical Society of America · doi:10.1121/1.4824123 · Cited by 28
Ship roll control and power absorption using a U-tube anti-roll tank
Alujević, N., Ćatipović, I., Malenica, Š., Senjanović, I., & Vladimir, N. (2019) · Ocean Engineering · doi:10.1016/j.oceaneng.2018.12.007 · Cited by 28
“Even when applying different optimisation criteria on other types of oscillation absorber systems (Iwata, 1982; Krenk, 2005; Miller et al., 1985; Nishihara and Asami, 2002; Yamaguchi, 1988; Zilletti et al., 2012) the optimum natural frequency ratio close to unity has been obtained.”
BackgroundMethodVibration control by piezoelectric proof-mass absorber with resistive-inductive shunt
Høgsberg, J. (2019) · Mechanics of Advanced Materials and Structures · doi:10.1080/15376494.2018.1551587 · Cited by 28
“Therefore, the energy harvesting system analyzed in for example [11] is seemingly of the same order as for vibration control of structure by the classic tuned mass damper (TMD) [12, 13].”
BackgroundMethodInfluentialInerter dampers with linear hysteretic damping for cable vibration control
Sun, L., Sun, J., Nagarajaiah, S., & Chen, L. (2021) · Engineering Structures · doi:10.1016/j.engstruct.2021.113069 · Cited by 27
“Here following the method in [52] and [50], an approximate numerical method is proposed to determine the optimal damping effect of a TIDH on a taut cable and the corresponding damper parameters.”
Optimal design of a tunable electromagnetic shunt damper for dynamic vibration absorber
Sun, R., Wong, W. O., & Li, C. (2022) · Mechatronics · doi:10.1016/j.mechatronics.2022.102763 · Cited by 27
A comparison of robustness and performance of linear and nonlinear Lanchester dampers
Vakilinejad, M., Grolet, A., & Thomas, O. (2020) · Nonlinear Dynamics · doi:10.1007/s11071-020-05512-x · Cited by 27
Magnetically tuned mass dampers for optimal vibration damping of large structures
Bourquin, F., Caruso, G., Peigney, M., & Siegert, D. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/8/085009 · Cited by 26
“The curves resemble the well-known behaviour of classical TMDs mounted on harmonically excited structures [25].”
BackgroundOptimal piezoelectric resistive–inductive shunt damping of plates with residual mode correction
Toftekær, J. F., Benjeddou, A., Høgsberg, J., & Krenk, S. (2018) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x18798953 · Cited by 26
“They are seen to be in good agreement with the frequencies determined by the beam model in Høgsberg and Krenk (2015). The reason for the slightly lower frequencies is mainly due to the omission of the patches bending contribution in the present model.”
BackgroundMethodResultInfluentialSelf-citationYan, B., Zhou, S., Zhao, C., Wang, K., & Wu, C. (2018) · Journal of Aerospace Engineering · doi:10.1061/(asce)as.1943-5525.0000955 · Cited by 26
Optimal control and performance evaluation of an inerter-based point absorber wave energy converter
Sun, T., & Zhang, Z. (2022) · Ocean Engineering · doi:10.1016/j.oceaneng.2022.111883 · Cited by 25
Wielgos, P., & Geryło, R. (2021) · Applied Sciences · doi:10.3390/app11041389 · Cited by 24
A transmissibility-based procedure to estimate the modal properties of an on-board tuned mass damper
Magdaleno, Á., & Lorenzana, A. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.106378 · Cited by 23
Chen, B., Zhang, Z., & Hua, X. (2022) · Structural Control and Health Monitoring · doi:10.1002/stc.3106 · Cited by 23
LRLC-shunted piezoelectric vibration absorber
Berardengo, M., Høgsberg, J., Manzoni, S., Vanali, M., Brandt, A., & Godi, T. (2020) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2020.115268 · Cited by 23
SMA-based adaptive tuned mass dampers: Analysis and comparison
Manzoni, S., Argentino, A., Lucà, F., Berardengo, M., & Vanali, M. (2022) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2022.109883 · Cited by 23
Tuning of vibration absorbers by an effective modal coupling factor
Høgsberg, J., Lossouarn, B., & Deü, J. (2024) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2024.109009 · Cited by 22
“As argued by Krenk and Høgsberg [35], the TID – although model-wise fully equivalent to the TMD – is much more sensitive to modal interaction with other modes because it operates on relative motion of the structure.”
InfluentialThe Behaviour of Mistuned Piezoelectric Shunt Systems and Its Estimation
Berardengo, M., Manzoni, S., & Vanali, M. (2016) · Shock and Vibration · doi:10.1155/2016/9739217 · Cited by 22
“The tuning criterion considered here fixes the values of R and L based on the procedure briefly summarised here below: (i) The trend of |Tzw| is independent of the damping factor of the electrical circuit di at two frequency values ωA and ωB (see the corresponding points A and B in Figure 3(a)) (ω is the circular freq…”
BackgroundMethodEdgewise vibration control of wind turbine blades using negative stiffness TMDs
Sonkusare, V. D., & Bera, K. K. (2025) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2025.110636 · Cited by 21
Wang, M., Chen, J., Sun, F., Nagarajaiah, S., & Du, X. (2024) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4243 · Cited by 21
“Following the procedure suggested by Krenk, 27 a frequency ratio located centrally in the interval between the two fixed points P and Q is determined as: which represents the limit scenario where the infinite damping ratio 𝜁 d the damper constrains the relative motion 𝑋 d of the damper mass, and…”
Influential
Metadata
- Authors
- Krenk, S.
- Affiliations
- Technical University of Denmark (DK)
- Corresponding author
- Krenk, Steen
- ORCID
- Krenk, Steen
- Venue
- Journal of Applied Mechanics
- Publisher
- ASME International
- Published
- 2005-05-15
- Volume
- 72
- Issue
- 6
- Pages
- 936-942
- ISSN
- 0021-8936 (ISSN-L)
- 1528-9036
- OpenAlex
- W1968064524
- Cited by
- 217
- References
- 7
- Citations by year
- 2026: 16 · 2025: 17 · 2024: 16 · 2023: 17 · 2022: 23 · 2021: 25 · 2020: 14 · 2019: 14 · 2018: 8 · 2017: 7 · 2016: 10 · 2015: 11 · 2014: 9 · 2013: 10 · 2012: 10
- FWCI
- 4.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Mechanics (publishedVersion)
- Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Mechanical Engineering › Vibration and Dynamic Analysis
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Engineering and Vibration Analysis
- Keywords
- tuned mass damper, viscous damping, optimal damping, dynamic amplification, complex natural frequencies, frequency tuning, bifurcation, modal damping, structural vibration control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.