Line-field confocal optical coherence tomography for high-resolution noninvasive imaging of skin tumors
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
An optical technique called line-field confocal optical coherence tomography (LC-OCT) is introduced for high-resolution, noninvasive imaging of human skin in vivo. LC-OCT combines the principles of time-domain optical coherence tomography and confocal microscopy with line illumination and detection using a broadband laser and a line-scan camera. LC-OCT measures the echo-time delay and amplitude of light backscattered from cutaneous microstructures through low-coherence interferometry associated with confocal spatial filtering. Multiple A-scans are acquired simultaneously while dynamically adjusting the focus. The resulting cross-sectional B-scan image is produced in real time at 10 frame / s. With an isotropic spatial resolution of ∼1 μm, the LC-OCT images reveal a comprehensive structural mapping of skin at the cellular level down to a depth of ∼500 μm. LC-OCT has been applied to the imaging of various skin lesions, in vivo, including carcinomas and melanomas. LC-OCT images are found to strongly correlate with conventional histopathological images. The use of LC-OCT as an adjunct tool in medical practice could significantly improve clinical diagnostic accuracy while reducing the number of biopsies of benign lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
Diagnostic accuracy of dermoscopy
Kittler, H., Pehamberger, H., Wolff, K., & Binder, M. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00679-4 · Cited by 1,349 · cited 1×
“On the other hand, ∼20% of all skin cancers (including roughly a third of melanomas) are missed at an early stage.(6) Given these”
BackgroundIn vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
Epidemiological trends in skin cancer
Apalla, Z., Lallas, A., Sotiriou, E., Lazaridou, E., & Ioannides, D. (2017) · Dermatology Practical & Conceptual · doi:10.5826/dpc.0702a01 · Cited by 628
Optical coherence tomography in dermatology: a review
Welzel, J. (2001) · Skin Research and Technology · doi:10.1034/j.1600-0846.2001.007001001.x · Cited by 621
Koenig, K., & Riemann, I. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1577349 · Cited by 535
Pellacani, G., Guitera, P., Longo, C., Avramidis, M., Seidenari, S., & Menzies, S. (2007) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5700993 · Cited by 452
Optical coherence tomography of the human skin
Welzel, J., Lankenau, E., Birngruber, R., & Engelhardt, R. (1997) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(97)70072-0 · Cited by 442
Full-field optical coherence microscopy
Beaurepaire, E., Boccara, A. C., Lebec, M., Blanchot, L., & Saint-Jalmes, H. (1998) · Optics Letters · doi:10.1364/ol.23.000244 · Cited by 433
Efficient nonlinear algorithm for envelope detection in white light interferometry
Larkin, K. G. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.000832 · Cited by 417
Interferometric synthetic aperture microscopy
Ralston, T. S., Marks, D. L., Scott Carney, P., & Boppart, S. A. (2007) · Nature Physics · doi:10.1038/nphys514 · Cited by 408
Ultrahigh-resolution full-field optical coherence tomography
Dubois, A., Grieve, K., Moneron, G., Lecaque, R., Vabre, L., & Boccara, C. (2004) · Applied Optics · doi:10.1364/ao.43.002874 · Cited by 394
Self-citationHigh-resolution optical coherence tomography over a large depth range with an axicon lens
Ding, Z., Ren, H., Zhao, Y., Nelson, J. S., & Chen, Z. (2002) · Optics Letters · doi:10.1364/ol.27.000243 · Cited by 367
PODOLEANU, A. G. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03619.x · Cited by 348
Guitera, P., Pellacani, G., Crotty, K. A., Scolyer, R. A., Li, L.-X. L., Bassoli, S., Vinceti, M., Rabinovitz, H., Longo, C., & Menzies, S. W. (2010) · Journal of Investigative Dermatology · doi:10.1038/jid.2010.84 · Cited by 306
Lee, K.-S., & Rolland, J. P. (2008) · Optics Letters · doi:10.1364/ol.33.001696 · Cited by 240
Ulrich, M., Braunmuehl, T., Kurzen, H., Dirschka, T., Kellner, C., Sattler, E., Berking, C., Welzel, J., & Reinhold, U. (2015) · British Journal of Dermatology · doi:10.1111/bjd.13853 · Cited by 160
Optical coherence microscopy for deep tissue imaging of the cerebral cortex with intrinsic contrast
Srinivasan, V. J., Radhakrishnan, H., Jiang, J. Y., Barry, S., & Cable, A. E. (2012) · Optics Express · doi:10.1364/oe.20.002220 · Cited by 159
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
Kollias, N., & Stamatas, G. N. (2002) · Journal of Investigative Dermatology Symposium Proceedings · doi:10.1046/j.1523-1747.2002.19635.x · Cited by 158
Clinical Diagnosis of Skin Cancer
Glazer, A. M., Rigel, D. S., Winkelmann, R. R., & Farberg, A. S. (2017) · Dermatologic Clinics · doi:10.1016/j.det.2017.06.001 · Cited by 113
Gabor-based fusion technique for Optical Coherence Microscopy
Rolland, J. P., Meemon, P., Murali, S., Thompson, K. P., & Lee, K. (2010) · Optics Express · doi:10.1364/oe.18.003632 · Cited by 112
Full-Field Optical Coherence Tomography: A New Technology for 3D High-Resolution Skin Imaging
Dalimier, E., & Salomon, D. (2012) · Dermatology · doi:10.1159/000337423 · Cited by 110
Optical Coherence Tomography in the Diagnosis of Skin Cancer
Levine, A., Wang, K., & Markowitz, O. (2017) · Dermatologic Clinics · doi:10.1016/j.det.2017.06.008 · Cited by 94
Histological correlates of optical coherence tomography in non‐melanoma skin cancer
Coleman, A. J., Richardson, T. J., Orchard, G., Uddin, A., Choi, M. J., & Lacy, K. E. (2013) · Skin Research and Technology · doi:10.1111/j.1600-0846.2012.00626.x · Cited by 81
Digital Dermoscopic Monitoring of Atypical Nevi in Patients at Risk for Melanoma
Fuller, S. R., Bowen, G. M., Tanner, B., Florell, S. R., & Grossman, D. (2007) · Dermatologic Surgery · doi:10.1097/00042728-200710000-00006 · Cited by 77
Champin, J., Perrot, J., Cinotti, É., Labeille, B., Douchet, C., Parrau, G., Cambazard, F., Séguin, P., & Alix, T. (2014) · Dermatologic Surgery · doi:10.1111/dsu.12432 · Cited by 73
Self-citationUltrahigh speed spectral-domain optical coherence microscopy
Lee, H., Liu, J. J., Sheikine, Y., Aguirre, A. D., Connolly, J. L., & Fujimoto, J. G. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001236 · Cited by 29
US melanoma prevalence has doubled over past 30 years
McCarthy, M. (2015) · BMJ · doi:10.1136/bmj.h3074 · Cited by 18
Dermoscopy in the era of dermato-oncology: from bed to bench side and retour
Woltsche, N., Schwab, C., Deinlein, T., Hofmann‐Wellenhof, R., & Zalaudek, I. (2016) · Expert Review of Anticancer Therapy · doi:10.1586/14737140.2016.1168700 · Cited by 14
Cited by
Applications and future directions for optical coherence tomography in dermatology*
Wan, B., Ganier, C., Du‐Harpur, X., Harun, N., Watt, F. M., Patalay, R., & Lynch, M. D. (2021) · British Journal of Dermatology · doi:10.1111/bjd.19553 · Cited by 148
Line-Field Confocal Optical Coherence Tomography (LC-OCT) for Skin Imaging in Dermatology
Latriglia, F., Ogien, J., Tavernier, C., Fischman, S., Suppa, M., Perrot, J.-L., & Dubois, A. (2023) · Life · doi:10.3390/life13122268 · Cited by 74
“The LC-OCT technique is based on a combination of OCT and RCM with the illumination of the skin with a focused line of light [23].”
BackgroundMethodInfluentialSelf-citationLentsch, G., Baugh, E. G., Lee, B., Aszterbaum, M., Zachary, C. B., Kelly, K. M., & Balu, M. (2022) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2022.01.016 · Cited by 41
“There are continuous efforts to improve the spatial resolution of OCT (Dubois et al., 2018; Wang et al., 2021), the RCM contrast (Campanella et al.”
BackgroundEvaluating facial dermis aging in healthy Caucasian females with LC-OCT and deep learning
Assi, A., Fischman, S., Lopez, C., Pedrazzani, M., Grignon, G., Missodey, R., Korichi, R., Cauchard, J.-H., Ralambondrainy, S., & Bonnier, F. (2024) · Scientific Reports · doi:10.1038/s41598-024-74370-z · Cited by 13
Le Blay, H., Raynaud, E., Bouayadi, S., Rieux, E., Rolland, G., Saussine, A., Jachiet, M., Bouaziz, J., & Lynch, B. (2024) · Skin Research and Technology · doi:10.1111/srt.13891 · Cited by 12
Metadata
- Authors
- Dubois, A., Levecq, O., Azimani, H., Siret, D., Barut, A., Suppa, M., del Marmol, V., Malvehy, J., Cinotti, E., Rubegni, P., & Perrot, J.-L.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2018-10-23
- Volume
- 23
- Issue
- 10
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2898008100
- Cited by
- 269
- References
- 31
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.