Virtual clinical trials in medical imaging: a review
Open accessThe DOI matches its Crossref record; 190 of the 190 references it cites were found in a registry or an index.
Abstract
The accelerating complexity and variety of medical imaging devices and methods have outpaced the ability to evaluate and optimize their design and clinical use. This is a significant and increasing challenge for both scientific investigations and clinical applications. Evaluations would ideally be done using clinical imaging trials. These experiments, however, are often not practical due to ethical limitations, expense, time requirements, or lack of ground truth. Virtual clinical trials (VCTs) (also known as in silico imaging trials or virtual imaging trials) offer an alternative means to efficiently evaluate medical imaging technologies virtually. They do so by simulating the patients, imaging systems, and interpreters. The field of VCTs has been constantly advanced over the past decades in multiple areas. We summarize the major developments and current status of the field of VCTs in medical imaging. We review the core components of a VCT: computational phantoms, simulators of different imaging modalities, and interpretation models. We also highlight some of the applications of VCTs across various imaging modalities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332 · cited 1×
“18,19 20 – 22 If successful, such algorithms can replace the time-consuming manual meth-ods previously used in the phantom development process.”
MethodThe UK Biobank resource with deep phenotyping and genomic data
Bycroft, C., Freeman, C., Petkova, D., Band, G., Elliott, L. T., Sharp, K., Motyer, A., Vukcevic, D., Delaneau, O., O’Connell, J., et al. (2018) · Nature · doi:10.1038/s41586-018-0579-z · Cited by 8,876
Geant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946 · cited 1×
“The large MCNP 11 and Geant4 MC software packages, 154 which were originally designed for high-energy physics and nuclear energy research, have also been applied to PET and SPECT simulation.”
MethodRadiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084 · cited 1×
“267 – 269.”
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
Artificial intelligence in radiology
Hosny, A., Parmar, C., Quackenbush, J., Schwartz, L. H., & Aerts, H. J. W. L. (2018) · Nature Reviews Cancer · doi:10.1038/s41568-018-0016-5 · Cited by 3,803
Bloch, F. (1946) · Physical Review · doi:10.1103/physrev.70.460 · Cited by 3,676
Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
Jensen, J. A., & Svendsen, N. B. (1992) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.139123 · Cited by 2,493 · cited 2×
“Because propagation is not directly modeled, field II 199 can only simulate homogeneous media although it can apply frequency-dependent attenuation.”
BackgroundMethodk-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields
Treeby, B. E., & Cox, B. T. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3360308 · Cited by 2,337
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258 · cited 1×
“267 – 269.”
Multimodal population brain imaging in the UK Biobank prospective epidemiological study
Miller, K. L., Alfaro-Almagro, F., Bangerter, N. K., Thomas, D. L., Yacoub, E., Xu, J., Bartsch, A. J., Jbabdi, S., Sotiropoulos, S. N., Andersson, J. L. R., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4393 · Cited by 2,020 · cited 1×
“12 To 15 – 17 Image registration methods have also been used to more efficiently create phantom populations.”
MethodDesign and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822
Verification and Validation in Scientific Computing
Oberkampf, W. L., & Roy, C. J. (2010) · doi:10.1017/cbo9780511760396 · Cited by 1,556 · cited 1×
“The goal is to identify the sources of uncertainties and determine how much they influence the final performance measure by repeating simulations while perturbing these parameters and examining the results.(368) Such studies can enhance the confidence in the VCT predictions and thus offer validation confidence.”
Background4D XCAT phantom for multimodality imaging research
Segars, W. P., Sturgeon, G., Mendonca, S., Grimes, J., & Tsui, B. M. W. (2010) · Medical Physics · doi:10.1118/1.3480985 · Cited by 1,287 · cited 1×
“For surface-based models, 7,72 the transformations are applied to the surface control or vertex points defining the objects.”
MethodSelf-citationBloch Equations with Diffusion Terms
Torrey, H. C. (1956) · Physical Review · doi:10.1103/physrev.104.563 · Cited by 1,216
Initial MCNP6 Release Overview
Goorley, T., James, M., Booth, T., Brown, F., Bull, J., Cox, L. J., Durkee, J., Elson, J., Fensin, M., Forster, R. A., et al. (2012) · Nuclear Technology · doi:10.13182/nt11-135 · Cited by 1,181 · cited 1×
“These phantoms are advantageous in that they can be directly input into some commonly used Monte Carlo (MC) simulation codes [e.g., Geometry and Tracking (Geant4), 9 Monte Carlo N-Particle (MCNP6), 10 and Particle and Heavy-Ion Transport code System (PHITS) 11 ].”
MethodStejskal, E. O. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1696526 · Cited by 894 · cited 1×
“176 Several solvers have been proposed in the literature.”
BackgroundJan, S., Benoit, D., Becheva, E., Carlier, T., Cassol, F., Descourt, P., Frisson, T., Grevillot, L., Guigues, L., Maigne, L., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/001 · Cited by 794
Thrall, J. H., Li, X., Li, Q., Cruz, C., Do, S., Dreyer, K., & Brink, J. (2018) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2017.12.026 · Cited by 710
MRI simulation-based evaluation of image-processing and classification methods
Kwan, R. K.-S., Evans, A. C., & Pike, G. B. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.816072 · Cited by 709 · cited 1×
“In the studies by Kwan 330 and Aubert-Broche, 331 they developed a simulator to quantitatively evaluate image analysis methods in brain MRI under different imaging conditions by varying scan parameters.”
BackgroundAn accurate method for computer‐generating tungsten anode x‐ray spectra from 30 to 140 kV
Boone, J. M., & Seibert, J. A. (1997) · Medical Physics · doi:10.1118/1.597953 · Cited by 706
Automatic Multi-Organ Segmentation on Abdominal CT With Dense V-Networks
Gibson, E., Giganti, F., Hu, Y., Bonmati, E., Bandula, S., Gurusamy, K., Davidson, B., Pereira, S. P., Clarkson, M. J., & Barratt, D. C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2806309 · Cited by 697
Ws, S., Hl, F., Mr, F., & Warner, G. G. (1969) · PubMed · Cited by 627
Birch, R., & Marshall, M. (1979) · Physics in Medicine & Biology · doi:10.1088/0031-9155/24/3/002 · Cited by 512 · cited 1×
“For the x-ray source, models of the polyenergetic spectrum 85 – 100 and focal spot shape and size 101 – 104 are essential.”
BackgroundDevelopment of General-Purpose Particle and Heavy Ion Transport Monte Carlo Code
IWASE, H., NIITA, K., & NAKAMURA, T. (2002) · Journal of Nuclear Science and Technology · doi:10.1080/18811248.2002.9715305 · Cited by 507 · cited 1×
“These phantoms are advantageous in that they can be directly input into some commonly used Monte Carlo (MC) simulation codes [e.g., Geometry and Tracking (Geant4), 9 Monte Carlo N-Particle (MCNP6), 10 and Particle and Heavy-Ion Transport code System (PHITS) 11 ].”
MethodThe Generalized Contrast-to-Noise Ratio: A Formal Definition for Lesion Detectability
Rodríguez-Molares, A., Rindal, O. M. H., D’hooge, J., Måsøy, S., Austeng, A., Bell, M. A. L., & Torp, H. G. (2019) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2019.2956855 · Cited by 498
Realistic reference phantoms: An ICRP/ICRU joint effort
(2009) · Annals of the ICRP · doi:10.1016/j.icrp.2009.09.001 · Cited by 496 · cited 1×
“325,326 For diagnostic imaging purposes, the results are useful in setting guidelines for the maximum allowable injected dose for the best possible image quality while protecting patients from the harmful effects of radiation, especially to critical organs that are most sensitivity to radiation.”
MethodRafferty, E. A., Park, J. M., Philpotts, L. E., Poplack, S. P., Sumkin, J. H., Halpern, E. F., & Niklason, L. T. (2012) · Radiology · doi:10.1148/radiol.12120674 · Cited by 481 · cited 2×
“The results of the VCT were compared with data reported by Rafferty et al.(293) To”
ResultBoone, J. M., Fewell, T. R., & Jennings, R. J. (1997) · Medical Physics · doi:10.1118/1.598100 · Cited by 452
Realistic CT simulation using the 4D XCAT phantom
Segars, W. P., Mahesh, M., Beck, T. J., Frey, E. C., & Tsui, B. M. W. (2008) · Medical Physics · doi:10.1118/1.2955743 · Cited by 412
Self-citationAddition of a channel mechanism to the ideal-observer model
Myers, K. J., & Barrett, H. H. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.002447 · Cited by 400 · cited 1×
“Frequency domain computation is more practical when a smaller number of images are available, enabling practical comparison of image quality across patients, abnormalities, and imaging systems, further expandable to cross-system and cross-modality comparisons.(227,263,264) They, however, are restricted to conditions o…”
BackgroundUnified SNR analysis of medical imaging systems
Wagner, R. F., & Brown, D. G. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/6/001 · Cited by 387 · cited 1×
“Frequency domain computation is more practical when a smaller number of images are available, enabling practical comparison of image quality across patients, abnormalities, and imaging systems, further expandable to cross-system and cross-modality comparisons.(227,263,264) They, however, are restricted to conditions o…”
BackgroundGeometric skinning with approximate dual quaternion blending
Kavan, L., Collins, S., Žára, J., & O'Sullivan, C. (2008) · ACM Transactions on Graphics · doi:10.1145/1409625.1409627 · Cited by 385 · cited 1×
“81 – 83 In addition to positioning, certain breast imaging modalities, such as mammography and tomosynthesis, also require the patient to undergo varying degrees of breast compression.”
BackgroundXu, X. G., Chao, T. C., & Bozkurt, A. (2000) · Health Physics · doi:10.1097/00004032-200005000-00003 · Cited by 364
The German National Cohort: aims, study design and organization
German National Cohort (GNC) Consortium (2014) · European Journal of Epidemiology · doi:10.1007/s10654-014-9890-7 · Cited by 364
Badal, A., & Badano, A. (2009) · Medical Physics · doi:10.1118/1.3231824 · Cited by 358
A VISUAL DISCRIMINATION MODEL FOR IMAGING SYSTEM DESIGN AND EVALUATION
LUBIN, J. (1995) · Vision Models for Target Detection and Recognition · doi:10.1142/9789812831200_0010 · Cited by 325
Abbey, C. K., & Barrett, H. H. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.000473 · Cited by 324
k-t SPARSE: High frame rate dynamic MRI exploiting spatio-temporal sparsity
Lustig, M. S., Santos, J. M., Donoho, D. L., & Pauly, J. M. (2006) · Cited by 313
k‐t PCA: Temporally constrained k‐t BLAST reconstruction using principal component analysis
Pedersen, H., Kozerke, S., Ringgaard, S., Nehrke, K., & Kim, W. Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22052 · Cited by 294
Byra, M., Styczynski, G., Szmigielski, C., Kalinowski, P., Michałowski, Ł., Paluszkiewicz, R., Ziarkiewicz-Wróblewska, B., Zieniewicz, K., Sobieraj, P., & Nowicki, A. (2018) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-018-1843-2 · Cited by 294
Automated measurement of fetal head circumference using 2D ultrasound images
van den Heuvel, T. L. A., de Bruijn, D., de Korte, C. L., & Ginneken, B. V. (2018) · PLOS ONE · doi:10.1371/journal.pone.0200412 · Cited by 280
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
A new improved version of the realistic digital brain phantom
Aubert-Broche, B., Evans, A. C., & Collins, L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.052 · Cited by 275 · cited 1×
“In the studies by Kwan 330 and Aubert-Broche, 331 they developed a simulator to quantitatively evaluate image analysis methods in brain MRI under different imaging conditions by varying scan parameters.”
BackgroundBarrett, H. H., Abbey, C. K., & Clarkson, E. W. (1998) · Journal of the Optical Society of America A · doi:10.1364/josaa.15.001520 · Cited by 274
Badano, A., Graff, C. G., Badal, A., Sharma, D., Zeng, R., Samuelson, F. W., Glick, S. J., & Myers, K. J. (2018) · JAMA Network Open · doi:10.1001/jamanetworkopen.2018.5474 · Cited by 235 · cited 2×
“Food and Drug Administration (FDA) compared the performance of DBT and DM with predicate premarket approval data for masses and calcifications based on differences in AUC.(26) In further work, Bakic et al.”
BackgroundMonte Carlo study of a two‐compartment exchange model of diffusion
Fieremans, E., Novikov, D. S., Jensen, J. H., & Helpern, J. A. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1577 · Cited by 233 · cited 1×
“These methods are impractical for tissue models with realistic microstructural complexity, needing many hours (or even days) of processing for single simulations.(191) This”
MethodGeneration of an Anatomically Based Three-Dimensional Model of the Conducting Airways
Tawhai, M. H., Pullan, A. J., & Hunter, P. J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1289457 · Cited by 229
Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization
Segars, W. P., Bond, J., Frush, J., Hon, S., Eckersley, C., Williams, C. H., Feng, J., Tward, D. J., Ratnanather, J. T., Miller, M. I., et al. (2013) · Medical Physics · doi:10.1118/1.4794178 · Cited by 228 · cited 1×
“The XCAT library of adult and pediatric phantoms was created in this manner.(18,19) Recent works have focused on deep learning algorithms for automatic multiorgan image segmentation.”
BackgroundSelf-citationRealistic Analytical Phantoms for Parallel Magnetic Resonance Imaging
Guerquin-Kern, M., Lejeune, L., Pruessmann, K. P., & Unser, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2174158 · Cited by 217 · cited 1×
“Some authors have focused on developing simulated MRI data with emphasis in accurately modeling the geometry while achieving close-form expressions using polyhedral shapes.(181,182) These models, however, assume simplified models of the MR physics, viz.”
BackgroundConvergence and Parameter Choice for Monte-Carlo Simulations of Diffusion MRI
Hall, M. G., & Alexander, D. C. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2015756 · Cited by 215 · cited 1×
“In relationship to diffusion-weighed MRI, recent works employ MC 188,189 and other techniques.”
MethodThe SIMRI project: a versatile and interactive MRI simulator
Benoit-Cattin, H., Collewet, G., Belaroussi, B., Saint-Jalmes, H., & Odet, C. (2005) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2004.09.027 · Cited by 197
Hu, P., Wu, F., Peng, J., Bao, Y., Chen, F., & Kong, D. (2017) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-016-1501-5 · Cited by 194 · cited 1×
“18,19 20 – 22 If successful, such algorithms can replace the time-consuming manual meth-ods previously used in the phantom development process.”
MethodChase, J. G., Preiser, J.-C., Dickson, J. L., Pironet, A., Chiew, Y. S., Pretty, C. G., Shaw, G. M., Benyo, B., Moeller, K., Safaei, S., et al. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0455-y · Cited by 189
Hernandez, A. M., & Boone, J. M. (2014) · Medical Physics · doi:10.1118/1.4866216 · Cited by 182
High‐performance computing MRI simulations
Stöcker, T., Vahedipour, K., Pflugfelder, D., & Shah, N. J. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22406 · Cited by 164 · cited 2×
“Most solvers operate on regular 169,172,177,178 (e.g., Cartesian grids) or irregular 179,180 (e.g., tetrahedral grids) grids.”
BackgroundA three-dimensional breast software phantom for mammography simulation
Bliznakova, K., Bliznakov, Z., Bravou, V, Kolitsi, Z., & Pallikarakis, N. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/22/006 · Cited by 162 · cited 2×
“Several groups have each created phantoms, including those from UPenn, 23 – 25 FDA, 26,27 and Patras.”
BackgroundRahmim, A., Dinelle, K., Cheng, J.-C. K., Shilov, M. A., Segars, W. P., Lidstone, S. C., Blinder, S. A. L., ROUSSET, O. G., Vajihollahi, H., Tsui, B. M. W., et al. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.917248 · Cited by 158 · cited 1×
“Similar VCT studies have also been done to evaluate motion-compensated reconstruction algorithms in the context of head motions and PET brain imaging.(324) VCTs have also contributed significantly to the research and development of radiopharmaceuticals used in diagnostic nuclear medicine and recently in targeted radio…”
BackgroundSelf-citationAdaptation of GEANT4 to Monte Carlo dose calculations based on CT data
Jiang, H., & Paganetti, H. (2004) · Medical Physics · doi:10.1118/1.1796952 · Cited by 156
CatSim: a new computer assisted tomography simulation environment
Man, B. D., Basu, S., Chandra, N. S., Dunham, B., Edic, P. M., Iatrou, M., Mcolash, S. M., Sainath, P., Shaughnessy, C., Tower, B., et al. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.710713 · Cited by 154 · cited 2×
“141 – 143 For comprehensive virtual trials, models of more diverse scanners are needed.”
BackgroundMRXCAT: Realistic numerical phantoms for cardiovascular magnetic resonance
Wissmann, L., Santelli, C., Segars, W. P., & Kozerke, S. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/preaccept-1164254289127237 · Cited by 150
Self-citationVirtualDose : a software for reporting organ doses from CT for adult and pediatric patients
Ding, A., Gao, Y., Liu, H., Caracappa, P. F., Long, D., Bolch, W. E., Liu, B., & Xu, X. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/14/5601 · Cited by 145
Computation of the glandular radiation dose in digital tomosynthesis of the breast
Sechopoulos, I., Suryanarayanan, S., Vedantham, S., D’Orsi, C. J., & Karellas, A. (2006) · Medical Physics · doi:10.1118/1.2400836 · Cited by 142
Model Observers in Medical Imaging Research
He, X. J., & Park, S. (2013) · Theranostics · doi:10.7150/thno.5138 · Cited by 135
A GPU tool for efficient, accurate, and realistic simulation of cone beam CT projections
Jia, X., Yan, H., Cerviño, L., Folkerts, M., & Jiang, S. B. (2012) · Medical Physics · doi:10.1118/1.4766436 · Cited by 135
DukeSim: A Realistic, Rapid, and Scanner-Specific Simulation Framework in Computed Tomography
Abadi, E., Harrawood, B. P., Sharma, S., Kapadia, A., Segars, W. P., & Samei, E. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2886530 · Cited by 135 · cited 4×
“141 – 143 For comprehensive virtual trials, models of more diverse scanners are needed.”
BackgroundInfluentialSelf-citationFast Realistic MRI Simulations Based on Generalized Multi-Pool Exchange Tissue Model
Liu, F., Velikina, J., Block, W. F., Kijowski, R., & Samsonov, A. A. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2620961 · Cited by 133 · cited 2×
“To this effect, Liu et al. 178 presented a generalized multipool exchange tissue model; examples of these techniques are quantitative magnetization transfer, quantitative T1 and T2 relaxometry, chemical exchange saturation transfer, etc. Liu et al. however noted that the same fundamental problem affects even basic MRI…”
BackgroundQuantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner
Zhang, X., Zhou, J., Cherry, S. R., Badawi, R. D., & Qi, J. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5e46 · Cited by 130
Li, X., Samei, E., Segars, W. P., Sturgeon, G. M., Colsher, J. G., Toncheva, G. I., Yoshizumi, T. T., & Frush, D. P. (2010) · Medical Physics · doi:10.1118/1.3515839 · Cited by 128
Self-citationBurrowes, K., Hunter, P. J., & Tawhai, M. H. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01033.2004 · Cited by 126 · cited 1×
“To incorporate the remaining vasculature and airway branches, multiple groups developed physiologically based algorithms that model air-ways, 37 – 39 vasculature, 40 or both together.”
MethodOpen access database of raw ultrasonic signals acquired from malignant and benign breast lesions
Piotrzkowska‐Wróblewska, H., Dobruch‐Sobczak, K., Byra, M., & Nowicki, A. (2017) · Medical Physics · doi:10.1002/mp.12538 · Cited by 125
Bakić, P. R., Zhang, C., & Maidment, A. D. A. (2011) · Medical Physics · doi:10.1118/1.3590357 · Cited by 125
Self-citationKiarashi, N., Nolte, A., Sturgeon, G. M., Segars, W. P., Ghate, S. V., Nolte, L. W., Samei, E., & Lo, J. Y.-C. (2015) · Medical Physics · doi:10.1118/1.4919771 · Cited by 123
Self-citationOptimized generation of high resolution breast anthropomorphic software phantoms
Pokrajac, D. D., Maidment, A. D. A., & Bakić, P. R. (2012) · Medical Physics · doi:10.1118/1.3697523 · Cited by 120 · cited 1×
“Several groups have each created phantoms, including those from UPenn, 23 – 25 FDA, 26,27 and Patras.”
BackgroundSelf-citationA User-Friendly Software Package for HIFU Simulation
Soneson, J. E., & Ebbini, E. S. (2009) · AIP conference proceedings · doi:10.1063/1.3131405 · Cited by 119
Drobnjak, I., Gavaghan, D. J., SÜLI, E. E., Pitt‐Francis, J., & Jenkinson, M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20939 · Cited by 118 · cited 2×
“Drobniak et al. 197 offered a software simulator for BOLD fMRI signal using the Bloch equation and accounting for field inhomogeneity induced by magnetic susceptibility variations (via Maxwell ’ s equations), rigid-body motion, chemical shift, RF field inhomogeneity, Eddy currents, and noise.”
MethodPatient-specific Radiation Dose and Cancer Risk for Pediatric Chest CT
Li, X., Samei, E., Segars, W. P., Sturgeon, G. M., Colsher, J. G., & Frush, D. P. (2011) · Radiology · doi:10.1148/radiol.11101900 · Cited by 116
Self-citationA new, open-source, multi-modality digital breast phantom
Graff, C. G. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2216312 · Cited by 113 · cited 1×
“Several groups have each created phantoms, including those from UPenn, 23 – 25 FDA, 26,27 and Patras.”
BackgroundIdeal observer approximation using Bayesian classification neural networks
Kupinski, M. A., Edwards, D. C., Giger, M. L., & Metz, C. E. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.952727 · Cited by 111 · cited 1×
“” In fact, the field of computer-aided diagnosis (which includes computer-aided detection, machine learning, and AI) and image perception (which includes model observers) have always shared many of the same methodologies going back several decades.(224,273) That work has continued to coalesce in recent years with “dee…”
Kainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109 · cited 2×
“The review articles by Xu(3) and Kainz et al.(2) provide a comprehensive guide to the various models that have”
Self-citationChristianson, O. I., Chen, J. J. S., Yang, Z., Saiprasad, G., Dima, A. A., Filliben, J. J., Peskin, A. P., Trimble, C., Siegel, E. L., & Samei, E. (2015) · Radiology · doi:10.1148/radiol.15132091 · Cited by 104
Self-citationMarsac, L., Chauvet, D., Greca, R. L., Boch, A., Chaumoître, K., Tanter, M., & Aubry, J. (2017) · International Journal of Hyperthermia · doi:10.1080/02656736.2017.1295322 · Cited by 102 · cited 1×
“It has been demonstrated that CT scans of ex vivo skull samples can be used with nonlinear simulation software to perform adaptive focusing through the skull by modeling the distortions of the propagating wave, both increasing the energy delivered and reducing the spatial spot size.(355) The use of these models for pu…”
CT scanner x‐ray spectrum estimation from transmission measurements
Duan, X., Wang, J., Yu, L., Leng, S., & McCollough, C. H. (2011) · Medical Physics · doi:10.1118/1.3547718 · Cited by 101
Mauger, C., Gilbert, K., Lee, A. M., Sanghvi, M. M., Aung, N., Fung, K., Carapella, V., Piechnik, S. K., Neubauer, S., Petersen, S. E., et al. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0551-6 · Cited by 98
Ultrasound simulation of complex flow velocity fields based on computational fluid dynamics
Swillens, A., Løvstakken, L., Kips, J. G., Torp, H. G., & Segers, P. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1071 · Cited by 96 · cited 2×
“Blood vessels of varying geometries have been simulated by pairing computational fluid dynamics software with pulse echo acoustic simulation for the development of flow estimation techniques, mimicking in a controlled environment the complex flow patterns observed in vivo.(212) Fig.”
MethodArtificial Intelligence May Cause a Significant Disruption to the Radiology Workforce
Mazurowski, M. A. (2019) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2019.01.026 · Cited by 95
Eom, J., Xu, X. G., De, S., & Shi, C. (2010) · Medical Physics · doi:10.1118/1.3455276 · Cited by 95 · cited 1×
“74 Finite-element techniques 75,76 are also being investigated to create physiologically based models for patient motions that can be altered in a physiologically informed way to realistically simulate normal and abnormal variations in individuals.”
BackgroundA High-Resolution Atlas and Statistical Model of the Human Heart From Multislice CT
Hoogendoorn, C., Duchateau, N., Sanchez-Quintana, D., Whitmarsh, T., Sukno, F. M., De Craene, M., Lekadir, K., & Frangi, A. F. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2230015 · Cited by 91
Self-citationVoxel-based models representing the male and female ICRP reference adult--the skeleton
Zankl, M., Eckerman, K. F., & Bolch, W. E. (2007) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncm269 · Cited by 89 · cited 1×
“57 Recently, some studies have showed that deep learning approaches, such as generative adversarial network (GAN) models, can synthesize images that have similar visual and statistical features of a set of training input data.”
BackgroundBadano, A. G., & Sempau, J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/6/013 · Cited by 87
Numerical study of water diffusion in biological tissues using an improved finite difference method
Xu, J., Does, M. D., & Gore, J. C. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/n01 · Cited by 84 · cited 1×
“In relationship to diffusion-weighed MRI, recent works employ MC(188,189) and other techniques.(190) These methods are impractical for tissue models with realistic microstructural complexity, needing many hours (or even days) of processing for single simulations.”
MethodMassively parallel models of the human circulatory system
Randles, A. P., Draeger, E. W., Oppelstrup, T., Krauss, L., & Gunnels, J. A. (2015) · International Conference for High Performance Computing, Networking, Storage and Analysis (SC) · doi:10.1145/2807591.2807676 · Cited by 82 · cited 1×
“Computational phantoms provide anatomical vessel models with which to simulate blood flow 77 and organ compartments to simulate contrast perfusion.”
BackgroundLung dosimetry for radioiodine treatment planning in the case of diffuse lung metastases.
Hong, S., He, B., Prideaux, A. R., Du, Y., Frey, E. C., Kasecamp, W., Ladenson, P. W., Wahl, R. L., & Sgouros, G. (2006) · PubMed · Cited by 82
Song, X., Segars, W. P., Du, Y., Tsui, B. M. W., & Frey, E. C. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/8/011 · Cited by 80 · cited 1×
“They allow accurate simulation of the photon attenuation and scattering through patient’s body(149,150) as well as the response of the collimator (SPECT) and the radiation detector of the imaging systems.(151) There is a wide selection of MC simulation software that is available for various PET and SPECT imaging appli…”
BackgroundSelf-citationMaeda, K., Matsumoto, M., & Taniguchi, A. (2005) · Medical Physics · doi:10.1118/1.1921647 · Cited by 80
Bliznakova, K. S., Suryanarayanan, S., Karellas, A., & Pallikarakis, N. E. (2010) · Medical Physics · doi:10.1118/1.3491812 · Cited by 78 · cited 1×
“28,29 Some examples of these phantoms can be seen in Fig.”
BackgroundTotal variation regularization in measurement and image space for PET reconstruction
Burger, M., Müller, J., Papoutsellis, E., & Schönlieb, C. (2014) · Inverse Problems · doi:10.1088/0266-5611/30/10/105003 · Cited by 78
The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization
Segars, W. P., Norris, H., Sturgeon, G. M., Zhang, Y., Bond, J., Minhas, A., Tward, D. J., Ratnanather, J. T., Miller, M. I., Frush, D. P., et al. (2015) · Medical Physics · doi:10.1118/1.4926847 · Cited by 75
Self-citationSolomon, J., & Samei, E. (2016) · Journal of medical imaging · doi:10.1117/1.jmi.3.3.035506 · Cited by 73
Self-citationSahbaee, P., Segars, W. P., & Samei, E. (2014) · Medical Physics · doi:10.1118/1.4883778 · Cited by 73 · cited 1×
“This relationship was found to be stronger for the organs inside the scan coverage.(295) Based on these studies, a smart phone application(295,302) was developed to estimate organ doses given the patient attribute and the imaging protocols.”
BackgroundSelf-citationBakić, P. R., Albert, M., Brzakovic, D. P., & Maidment, A. D. A. (2003) · Medical Physics · doi:10.1118/1.1586453 · Cited by 73 · cited 1×
“Several groups have each created phantoms, including those from UPenn, 23 – 25 FDA, 26,27 and Patras.”
BackgroundSelf-citationZhang, Y., Li, X., Segars, W. P., et al. (2012) · Medical Physics · doi:10.1118/1.4718710 · Cited by 72 · cited 1×
“303 Another VCT study investigated the dose reduction to breast while using an organ-based tube current modulation (TCM) and a breast-positioning technique.”
BackgroundSelf-citationA computational model to generate simulated three‐dimensional breast masses
de Sisternes, L., Brankov, J. G., Zysk, A. M., Schmidt, R. A., Nishikawa, R. M., & Wernick, M. N. (2015) · Medical Physics · doi:10.1118/1.4905232 · Cited by 72 · cited 1×
“, digital pathology) or with assumptions informed by morphometry studies.(66,67) Figure 7 shows examples of simulated oncological lesions using these methodologies.”
BackgroundAttar, R., Pereañez, M., Gooya, A., Albà, X., Zhang, L., de Vila, M. H., Lee, A. M., Aung, N., Lukaschuk, E. I., Sanghvi, M. M., et al. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.05.006 · Cited by 71 · cited 1×
“12 To 15 – 17 Image registration methods have also been used to more efficiently create phantom populations.”
MethodSelf-citationSimulation of Mammographic Lesions
Saunders, R. S., Samei, E., Baker, J. A., & DeLong, D. M. (2006) · Academic Radiology · doi:10.1016/j.acra.2006.03.015 · Cited by 69
Self-citationMRISIMUL: A GPU-Based Parallel Approach to MRI Simulations
Xanthis, C. G., Venetis, I. E., Chalkias, A. V., & Aletras, A. H. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2292119 · Cited by 69 · cited 1×
“Most solvers operate on regular 169,172,177,178 (e.g., Cartesian grids) or irregular 179,180 (e.g., tetrahedral grids) grids.”
BackgroundYoung, S., Bakić, P. R., Myers, K. J., Jennings, R. J., & Park, S. (2013) · Medical Physics · doi:10.1118/1.4800501 · Cited by 68
Abadi, E., Segars, W. P., Sturgeon, G. M., Roos, J. E., Ravin, C. E., & Samei, E. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2769640 · Cited by 68 · cited 3×
“41,42 These algorithms are volume-filling branching methods in which the parameters (branching angle, diameters, lengths, branching order, etc.) are informed by physiological laws (e.g., flow dynamics) and anatomical measurement studies.”
BackgroundMethodSelf-citationNew mesh-type phantoms and their dosimetric applications, including emergencies
Kim, C.-R., Yeom, Y. S., Nguyen, T. T., Han, M. C., Choi, C., Lee, H., Han, H., Shin, B., Lee, J.-K., Kim, H. S., et al. (2018) · Annals of the ICRP · doi:10.1177/0146645318756231 · Cited by 67 · cited 1×
“Beyond these categories, computational phantoms have been recently developed using volumetric tetrahedral meshes 8 as opposed to surfaces.”
Modeling RBC and Neutrophil Distribution Through an Anatomically Based Pulmonary Capillary Network
Burrowes, K., Tawhai, M. H., & Hunter, P. J. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000019178.95185.ad · Cited by 65
McElcheran, C. E., Golestanirad, L., Iacono, M. I., Wei, P., Yang, B. P., Anderson, K. J. T., Bonmassar, G., & Graham, S. J. (2019) · Scientific Reports · doi:10.1038/s41598-018-38099-w · Cited by 63
The presence of iodinated contrast agents amplifies DNA radiation damage in computed tomography
Pathe, C., Eble, K., Schmitz‐Beuting, D., Keil, B. R., Kaestner, B., Voelker, M. N., Kleb, B., KLOSE, K. J., & Heverhagen, J. T. (2011) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.453 · Cited by 62 · cited 1×
“Contrast perfusion is an important determinant of image quality as well as dose in imaging applications.(79) For instance, over 60% of CT images are acquired with a contrast agent.”
BackgroundDual-energy mammography: simulation studies
Bliznakova, K. S., Kolitsi, Z., & Pallikarakis, N. E. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/18/004 · Cited by 60
The lung physiome: merging imaging‐based measures with predictive computational models
Tawhai, M. H., Hoffman, E. A., & Lin, C. (2009) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.17 · Cited by 59
Grebenkov, D. S. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.11.009 · Cited by 55
Du, Y., Frey, E. C., Wang, W. T., Tocharoenchai, C., Baird, W. H., & Tsui, B. M. W. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.1039547 · Cited by 54
Self-citationHe, B., Wahl, R. L., Du, Y., Sgouros, G., Jacene, H., Flinn, I., & Frey, E. C. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.908131 · Cited by 53 · cited 1×
“…treatment planning and precision medicine, accurate radiation dosimetry estimation before treatment is important in determining the maximum possible injected dose for the individual patient, 327,328 especially children and newborns, 329 and after treatment for predicting treatment success.”
BackgroundDuchateau, N., Sermesant, M., Delingette, H., & Ayache, N. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2714343 · Cited by 53
Seamless Lesion Insertion for Data Augmentation in CAD Training
Pezeshk, A. X., Petrick, N., Chen, W.-J., & Sahiner, B. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2640180 · Cited by 53 · cited 1×
“For example, organs can be deformed to accommodate tumors in the lesion-local environment or structures can grow or shrink in size.(70,71) Models for physiological functions as presented below can also be altered to simulate abnormalities within them.”
BackgroundSynthesis of CT images from digital body phantoms using CycleGAN
Russ, T., Goerttler, S., Golla, A., Bauer, D. F., Hatamikia, S., Schad, L. R., Zöllner, F. G., & Chung, K. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-02042-9 · Cited by 51 · cited 1×
“features of a set of training input data.(58,59) These techniques can also be utilized for the purpose of modeling intraorgan heterogeneities within the organs and structures of computational phantoms, particularly for the parenchymal regions where organs usually have “textural” appearances.”
MethodSahbaee, P., Segars, W. P., Marin, D., Nelson, R. C., & Samei, E. (2017) · Radiology · doi:10.1148/radiol.2016152851 · Cited by 50 · cited 1×
“78 Fig.”
Self-citationBlochSolver: A GPU-optimized fast 3D MRI simulator for experimentally compatible pulse sequences
Kose, R., & Kose, K. (2017) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2017.05.007 · Cited by 50 · cited 4×
“Most solvers operate on regular 169,172,177,178 (e.g., Cartesian grids) or irregular 179,180 (e.g., tetrahedral grids) grids.”
BackgroundMethodInfluentialYu, L., Chen, B., Kofler, J. M., Favazza, C. P., Leng, S., Kupinski, M. A., & McCollough, C. H. (2017) · Medical Physics · doi:10.1002/mp.12380 · Cited by 49
Elangovan, P., Mackenzie, A., Dance, D. R., Young, K. C., Cooke, V., Wilkinson, L., Given-Wilson, R., Wallis, M., & Wells, K. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa622c · Cited by 48 · cited 2×
“Realistic breast models were developed by Elangovan et al.(285) for these purposes.”
MethodRealistic modeling of deep brain stimulation implants for electromagnetic MRI safety studies
Guérin, B., Serano, P. J., Iacono, M. I., Herrington, T. M., Widge, A. S., Dougherty, D. D., Bonmassar, G., Angelone, L. M., & Wald, L. L. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aabd50 · Cited by 48
Cao, Z., Oh, S., Sica, C. T., McGarrity, J. M., Horan, T., Luo, W., & Collins, C. M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24907 · Cited by 48 · cited 1×
“Cao et al., 162 for instance, utilized a Bloch-based 2-”
MethodZeng, D., Gao, Y., Huang, J., Bian, Z., Zhang, H., Lu, L., & Ma, J. (2016) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2016.07.002 · Cited by 47
Sompel, D. V. D., Brady, S. M., & Boone, J. M. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.07.004 · Cited by 46
Patient‐specific dose estimation for pediatric chest CT
Li, X., Samei, E., Segars, W. P., Sturgeon, G. M., Colsher, J. G., & Frush, D. P. (2008) · Medical Physics · doi:10.1118/1.3026593 · Cited by 45 · cited 1×
“These dosimetry studies showed an exponential relationship between the organ doses (as well as effective dose) and body diameter.(298,299) This relationship was found to be stronger for the organs inside the scan coverage.”
BackgroundSelf-citationCharacterization of energy response for photon‐counting detectors using x‐ray fluorescence
Ding, H. J., Cho, H.-M., Barber, W. C., Iwanczyk, J. S., & Molloi, S. Y. (2014) · Medical Physics · doi:10.1118/1.4900820 · Cited by 44
Hadjipanteli, A., Elangovan, P., Mackenzie, A., Looney, P. T., Wells, K., Dance, D. R., & Young, K. C. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa4f6e · Cited by 43 · cited 1×
“diameter of various lesions, showing that digital breast tomosynthesis (DBT) is superior to digital mammography (DM) for masses,(290) while the converse is true for calcifications.(291) Subsequent work(292) confirmed a significant difference between DM and DBT in mass detection”
BackgroundWangerin, K. A., Ahn, S., Wollenweber, S., Ross, S. G., Kinahan, P. E., & Manjeshwar, R. M. (2016) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.1.011002 · Cited by 42
Self-citationVisual‐search observers for assessing tomographic x‐ray image quality
Gifford, H. C., Liang, Z., & Das, M. (2016) · Medical Physics · doi:10.1118/1.4942485 · Cited by 42
Guérin, B., Angelone, L. M., Dougherty, D. D., & Wald, L. L. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27905 · Cited by 42
Modeling “Textured” Bones in Virtual Human Phantoms
Abadi, E., Segars, W. P., Sturgeon, G. M., Harrawood, B. P., Kapadia, A., & Samei, E. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2828083 · Cited by 42 · cited 1×
“In this study, an XCAT phantom 41,55 was imaged 50 times using a validated CT simulator, setup to mimic the parameters and settings of a specific scanner model (Siemens Definition Flash).”
MethodSelf-citationVirtual clinical trial of lesion detection in digital mammography and digital breast tomosynthesis
Bakić, P. R., Barufaldi, B., Higginbotham, D., Weinstein, S. P., Avanaki, A. R. N., Espig, K. S., Xthona, A., Kimpe, T. R. L., & Maidment, A. D. A. (2018) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2294934 · Cited by 42 · cited 2×
“26 In further work, Bakic et al. 213 compared the performance of DBT and DM in the detection of calcifications and masses, simulating the Hologic Selenia Dimensions under clinically realistic conditions.”
Self-citationA Simulation Tool for Dynamic Contrast Enhanced MRI
Pannetier, N. A., Debacker, C., Mauconduit, F., Christen, T., & Barbier, E. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057636 · Cited by 40 · cited 2×
“Pannetier et al.(195) developed a simulator to predict dynamic contrast enhancement in MRI with bolus tracking.”
BackgroundDose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models
Tian, X., Li, X., Segars, W. P., Frush, D. P., Paulson, E. K., & Samei, E. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/24/8755 · Cited by 40
Self-citationXie, T., Poletti, P., Platon, A., Becker, C., & Zaidi, H. (2017) · European Radiology · doi:10.1007/s00330-017-5000-z · Cited by 39 · cited 1×
“Organ doses have been estimated under various imaging protocols across virtual populations of adults, pediatrics,(296,298,299) and pregnant patients.(300,301) In addition, these studies investigated the relationship between the estimated organ doses and CT parameters and patient attributes.”
Population of 224 realistic human subject-based computational breast phantoms
Erickson, D. W., Wells, J. R., Sturgeon, G. M., et al. (2015) · Medical Physics · doi:10.1118/1.4937597 · Cited by 38 · cited 2×
“Patient-based phantoms include those from UMass 31 and Duke.”
BackgroundZhang, J., Xu, X. G., Shi, C., & Fuß, M. (2008) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v9i1.2700 · Cited by 38 · cited 1×
“For surface-based models, 7,72 the transformations are applied to the surface control or vertex points defining the objects.”
MethodSpinDoctor: A MATLAB toolbox for diffusion MRI simulation
Li, J., Nguyen, V.-D., Tran, T. N., Valdman, J., Trang, C.-B., Nguyen, K.-V., Vu, D. T. S., Tran, H. A., Tran, H. T. A., & Nguyen, T. M. P. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116120 · Cited by 37 · cited 2×
“Most solvers operate on regular 169,172,177,178 (e.g., Cartesian grids) or irregular 179,180 (e.g., tetrahedral grids) grids.”
BackgroundWolf, P. A., Jørgensen, J. S., Schmidt, T. G., & Sidky, E. Y. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5629 · Cited by 37
High performance MRI simulations of motion on multi-GPU systems
Xanthis, C. G., Venetis, I. E., & Aletras, A. H. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-16-48 · Cited by 37 · cited 1×
“MRISIMUL was developed in cardiac MRI and includes extensions to account for cardiac, respiratory, and blood flow motion.(171) However, this remains a Bloch solver useful for producing realistic cine MRI but not to incorporate MR diffusion terms.”
MethodHsu, C. M. L., Palmeri, M. L., Segars, W. P., Veress, A. I., & Dobbins, J. T. (2013) · Medical Physics · doi:10.1118/1.4794924 · Cited by 37 · cited 1×
“To address this limitation, investigators have created augmented patient-based phantoms using deformations and morphing, 33 addition of procedurally generated details, 34 and principal components analysis.”
MethodSelf-citationRealistic Simulation of Breast Tissue Microstructure in Software Anthropomorphic Phantoms
Bakić, P. R., Pokrajac, D. D., De, R., & Maidment, A. D. A. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-07887-8_49 · Cited by 33
Self-citationBadano, A. G., Badal, A., Glick, S. J., Graff, C. G., Samuelson, F. W., Sharma, D., & Zeng, R. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2255746 · Cited by 32
coreMRI: A high-performance, publicly available MR simulation platform on the cloud
Xanthis, C. G., & Aletras, A. H. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216594 · Cited by 32
A parametric finite element solution of the generalised Bloch–Torrey equation for arbitrary domains
Beltrachini, L., Taylor, Z. A., & Frangi, A. F. (2015) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.08.008 · Cited by 30 · cited 1×
“Beltrachini et al.(179) developed a parametric”
Self-citationInternal photon and electron dosimetry of the newborn patient—a hybrid computational phantom study
Wayson, M. B., Lee, C., Sgouros, G., Treves, S. T., Frey, E. C., & Bolch, W. E. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/5/1433 · Cited by 30 · cited 1×
“…treatment planning and precision medicine, accurate radiation dosimetry estimation before treatment is important in determining the maximum possible injected dose for the individual patient, 327,328 especially children and newborns, 329 and after treatment for predicting treatment success.”
BackgroundGong, C., Han, C., Gan, G., Deng, Z., Zhou, Y., Yi, J., Zheng, X., Xie, C., & Jin, X. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5d40 · Cited by 27
Evaluation of CNN as anthropomorphic model observer
Massanés, F., & Brankov, J. G. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2254603 · Cited by 27
Abadi, E., Sturgeon, G. M., Agasthya, G. A., Harrawood, B. P., Hoeschen, C., Kapadia, A., Segars, W. P., & Samei, E. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2254739 · Cited by 27
Self-citationQuantifying masking in clinical mammograms via local detectability of simulated lesions
Mainprize, J. G., Alonzo‐Proulx, O., Jong, R. A., & Yaffe, M. J. (2016) · Medical Physics · doi:10.1118/1.4941307 · Cited by 26
Statistical Personalization of Ventricular Fiber Orientation Using Shape Predictors
Lekadir, K., Hoogendoorn, C., Pereañez, M., Albà, X., Pashaei, A., & Frangi, A. F. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2297333 · Cited by 25
Self-citationMcGrath, D. M., Ravikumar, N., Wilkinson, I. D., Frangi, A. F., & Taylor, Z. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25881 · Cited by 25 · cited 1×
“344 – 352 With the advancement of phantoms in becoming more and more realistic, VCTs will find even more applications in MRI.”
BackgroundSelf-citationFour‐dimensional diffusion‐weighted MR imaging (4D‐DWI): a feasibility study
Liu, Y., Zhong, X., Czito, B. G., Palta, M., Bashir, M. R., Dale, B. M., Yin, F.-F., & Cai, J. (2016) · Medical Physics · doi:10.1002/mp.12037 · Cited by 25
A methodology to develop computational phantoms with adjustable posture for WBC calibration
Fonseca, T. C. F., Bogaerts, R., Hunt, J. G., & Vanhavere, F. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/6811 · Cited by 24
Effect of 18F-FDG Uptake Time on Lesion Detectability in PET Imaging of Early-Stage Breast Cancer
Wangerin, K. A., Muzi, M., Peterson, L. M., Linden, H. M., Novakova, A., O’Sullivan, F., Kurland, B. F., Mankoff, D. A., & Kinahan, P. E. (2015) · Tomography · doi:10.18383/j.tom.2015.00151 · Cited by 24
Self-citationSamei, E., Lin, Y., Choudhury, K. R., & McAdams, H. P. (2014) · Medical Physics · doi:10.1118/1.4899183 · Cited by 23
Self-citationWangerin, K. A., Muzi, M., Peterson, L. M., Linden, H. M., Novakova, A., Mankoff, D. A., & Kinahan, P. E. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6023 · Cited by 23
Self-citationSmartPhantom — an fMRI simulator
Cheng, H., Zhao, Q. C., Duensing, G. R., Edelstein, W. A., Spencer, D., Browne, N., Saylor, C., & Limkeman, M. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.012 · Cited by 23 · cited 2×
“Cheng et al. 196 developed a hardware simulator to generate reference functional blood oxygen level-dependent (BOLD) imaging data using a quadrature digital RF generator.”
Crookston, N. R., Fung, G. S. K., & Frey, E. C. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2842463 · Cited by 23
Investigation of statistical iterative reconstruction for dedicated breast CT
Makeev, A. V., & Glick, S. J. (2013) · Medical Physics · doi:10.1118/1.4811328 · Cited by 22
Technical Note: Noise models for virtual clinical trials of digital breast tomosynthesis
Borges, L. R. A. P., Barufaldi, B., Caron, R. F., Bakić, P. R., Foi, A., Maidment, A. D. A., & Vieira, M. A. C. (2019) · Medical Physics · doi:10.1002/mp.13534 · Cited by 21
Self-citationSimulation of Liver Lesions for Pediatric CT
Hoe, C. L., Samei, E., Frush, D. P., et al. (2006) · Radiology · doi:10.1148/radiol.2381050477 · Cited by 20 · cited 1×
“To make these lesions more realistic, researchers have segmented them from clinical images.(64,65) Compared with simple mathematical models, these segmented lesions have a more realistic rendition of the lesion.”
BackgroundSelf-citationZhang, Y., Ma, J., Iyengar, P., Zhong, Y., & Wang, J. (2017) · Medical Physics · doi:10.1002/mp.12259 · Cited by 20
Chang, Y., Lafata, K. J., Segars, W. P., et al. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab7309 · Cited by 16 · cited 2×
“6 shows an example of synthetic intraorgan “textures” added to an XCAT phantom using a dual-discriminator conditional GAN network trained on 3-D CT images.(59) For the purpose of creating computational phantoms, it would be more effective if the networks are trained based on higher resolution and higher quality images…”
MethodSelf-citationHarrison, R. L., Elston, B. F., Doot, R. K., Lewellen, T. K., Mankoff, D. A., & Kinahan, P. E. (2014) · Translational Oncology · doi:10.1593/tlo.13847 · Cited by 16
Self-citationZvereva, A., Schlattl, H., Zankl, M., Becker, J., Petoussi-Henss, N., Yeom, Y. S., Kim, C. H., Hoeschen, C., & Parodi, K. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.06.003 · Cited by 15 · cited 1×
“Using more realistic human phantoms and combining them with biodistribution data of a given radiopharmaceutical, VCT studies have provided more accurate estimates of average radiation dose to different organs of humans of different sexes, ages, and body builds.(325,326) For diagnostic imaging purposes, the results are…”
BackgroundEvaluation of wave delivery methodology for brain MRE: Insights from computational simulations
McGrath, D. M., Ravikumar, N., Beltrachini, L., Wilkinson, I. D., Frangi, A. F., & Taylor, Z. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26333 · Cited by 15
Self-citationBaydush, A. H., Catarious, D. M., Lo, J. Y.-C., Abbey, C. K., & Floyd, C. E. (2001) · Medical Physics · doi:10.1118/1.1420402 · Cited by 15
Self-citationA deep learning model observer for use in alterative forced choice virtual clinical trials
Alnowami, M. R., Mills, G., Young, K. C., Dance, D. R., Awais, M., Halling‐Brown, M., Wells, K., Elangovan, P., & Patel, M. N. (2018) · SPIE Medical Imaging: Image Perception, Observer Performance, and Technology Assessment · doi:10.1117/12.2293209 · Cited by 15
Portable simulation framework for diffusion MRI
Nguyen, V.-D., Leoni, M., Dancheva, T., Jansson, J., Hoffman, J., Wassermann, D., & Li, J. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.106611 · Cited by 13 · cited 1×
“Recently, other similar FE solvers have emerged,(180,186) some of which are open source and available on the cloud.(187) Simulators contributed greatly to the development of MRI understanding, optimization, and”
BackgroundFetal XCMR: a numerical phantom for fetal cardiovascular magnetic resonance imaging
Roy, C., Marini, D., Segars, W. P., Seed, M., & Macgowan, C. K. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0539-2 · Cited by 13 · cited 1×
“339 In such studies, simulation methods, providing the known anatomy and cardiac motion, are used to investigate acquisition and reconstruction methods in cardiac imaging.”
Self-citationA new fully-digital anthropomorphic and dynamic thorax/heart model
Haddad, R., Magnin, I. E., & Clarysse, P. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353715 · Cited by 12
Chen, X., Gong, X., Graff, C. G., Santana, M., Sturgeon, G. M., Sauer, T. J., Zeng, R., Glick, S. J., & Lo, J. Y.-C. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2255913 · Cited by 11 · cited 1×
“To address this limitation, investigators have created augmented patient-based phantoms using deformations and morphing, 33 addition of procedurally generated details, 34 and principal components analysis.”
MethodSelf-citationA Fast GPU-optimized 3D MRI Simulator for Arbitrary k-space Sampling
Kose, R., Setoi, A., & Kose, K. (2018) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.mp.2018-0022 · Cited by 10
Ravikumar, N., Gooya, A., Beltrachini, L., Frangi, A. F., & Taylor, Z. A. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.01.001 · Cited by 10
Self-citationA novel perfused Bloch–McConnell simulator for analyzing the accuracy of dynamic hyperpolarized MRS
Walker, C. M., Chen, Y., Lai, S. Y., & Bankson, J. A. (2016) · Medical Physics · doi:10.1118/1.4939877 · Cited by 10 · cited 2×
“Walker et al.(198) developed a simulator for magnetic”
BackgroundHan, M. C., Seo, J. M., Lee, S. H., Kim, C. H., Yeom, Y. S., Nguyen, T. T., Choi, C., Kim, S., Jeong, J. H., & Sohn, J. W. (2016) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2016.2601080 · Cited by 9 · cited 1×
“For voxel-based phantoms, the transformations are applied to the individual voxels and interpolation is used to generate subsequent images.(73) Transformations defining motion are typically based on patient imaging data, such as 4-D CT or MRI.”
MethodPhysiologically realistic LV models to produce normal and pathological image and phantom data
Veress, A. I., Segars, W. P., Tsui, B. M. W., Weiss, J. A., & Gullberg, G. T. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1466824 · Cited by 9 · cited 1×
“74 Finite-element techniques 75,76 are also being investigated to create physiologically based models for patient motions that can be altered in a physiologically informed way to realistically simulate normal and abnormal variations in individuals.”
BackgroundSelf-citationAutomatic Synthesis of Anthropomorphic Pulmonary CT Phantoms
Jiménez‐Carretero, D., Estépar, R. S. J., Cacio, M. D., & Ledesma‐Carbayo, M. J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0146060 · Cited by 9 · cited 1×
“To incorporate the remaining vasculature and airway branches, multiple groups developed physiologically based algorithms that model airways, vasculature,(40) or both together.(41,42) These algorithms are volume-filling branching methods in which the parameters (branching angle, diameters, lengths, branching order, etc.”
BackgroundZhou, W., & Anastasio, M. A. (2018) · SPIE Medical Imaging: Image Perception, Observer Performance, and Technology Assessment · doi:10.1117/12.2293772 · Cited by 6
Location- and lesion-dependent estimation of mammographic background tissue complexity
Avanaki, A. R. N., Espig, K. S., & Kimpe, T. R. L. (2017) · Journal of medical imaging · doi:10.1117/1.jmi.4.1.015501 · Cited by 6
Chan, L., Chan, T., Cheung, B. T., Mo, K., & Fung, K. K.-L. (2015) · Journal of Biomedical Engineering and Informatics · doi:10.5430/jbei.v1n1p93 · Cited by 6
Modeling dynamic, nutrient-access-based lesion progression using stochastic processes
Sauer, T. J., & Samei, E. (2019) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2513201 · Cited by 6 · cited 1×
“Lesion models have been further enhanced by creating a model by incorporating cell-level biological parameters and physiologically realistic growth mechanisms.(68) This lesion model determines the most probable approximation to the complete time evolution of a solid lesion based on known results from imaging and biolo…”
MethodSelf-citationUsing transfer learning for a deep learning model observer
Murphy, W., Halling‐Brown, M., Lewis, E. B., Elangovan, P., Young, K. C., Dance, D. R., & Wells, K. (2019) · SPIE Medical Imaging: Image Perception, Observer Performance, and Technology Assessment · doi:10.1117/12.2511750 · Cited by 5
Krapohl, D., Schubel, A., Fröjdh, E., Thungström, G., & Fröjdh, C. (2016) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2016.2555958 · Cited by 4 · cited 1×
“They can be applied to a simulation in its subcomponents 41,369,370 (e.g., model of x-ray spectrum), whole component 141,142,262,371,372 (e.g., accuracy in creating realistic simulated images), or multi-component 26,278 (e.g., accuracy in creating the complete human imaging process from the patient…”
Background
Cited by
Moving the goalposts while scoring―the dilemma posed by new PET technologies
Rogasch, J. M. M., Boellaard, R., Pike, L., Borchmann, P., Johnson, P., Wolf, J., Barrington, S. F., & Kobe, C. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05403-2 · Cited by 20
Metadata
- Authors
- Abadi, E., Segars, W. P., Tsui, B. M. W., Kinahan, P. E., Bottenus, N., Frangi, A. F., Maidment, A., Lo, J., & Samei, E.
- Venue
- Journal of Medical Imaging
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2020-04-11
- Volume
- 7
- Issue
- 04
- Pages
- 1
- ISSN
- 2329-4302 (ISSN-L)
- OpenAlex
- W3015379061
- Cited by
- 224
- References
- 190
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.