An evaluation of automatic coronary artery calcium scoring methods with cardiac CT using the orCaScore framework: Evaluation of cardiac CT-based automatic coronary calcium scoring
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: The amount of coronary artery calcification (CAC) is a strong and independent predictor of cardiovascular disease (CVD) events. In clinical practice, CAC is manually identified and automatically quantified in cardiac CT using commercially available software. This is a tedious and time-consuming process in large-scale studies. Therefore, a number of automatic methods that require no interaction and semiautomatic methods that require very limited interaction for the identification of CAC in cardiac CT have been proposed. Thus far, a comparison of their performance has been lacking. The objective of this study was to perform an independent evaluation of (semi)automatic methods for CAC scoring in cardiac CT using a publicly available standardized framework. METHODS: Cardiac CT exams of 72 patients distributed over four CVD risk categories were provided for (semi)automatic CAC scoring. Each exam consisted of a noncontrast-enhanced calcium scoring CT (CSCT) and a corresponding coronary CT angiography (CCTA) scan. The exams were acquired in four different hospitals using state-of-the-art equipment from four major CT scanner vendors. The data were divided into 32 training exams and 40 test exams. A reference standard for CAC in CSCT was defined by consensus of two experts following a clinical protocol. The framework organizers evaluated the performance of (semi)automatic methods on test CSCT scans, per lesion, artery, and patient. RESULTS: Five (semi)automatic methods were evaluated. Four methods used both CSCT and CCTA to identify CAC, and one method used only CSCT. The evaluated methods correctly detected between 52% and 94% of CAC lesions with positive predictive values between 65% and 96%. Lesions in distal coronary arteries were most commonly missed and aortic calcifications close to the coronary ostia were the most common false positive errors. The majority (between 88% and 98%) of correctly identified CAC lesions were assigned to the correct artery. Linearly weighted Cohen's kappa for patient CVD risk categorization by the evaluated methods ranged from 0.80 to 1.00. CONCLUSIONS: A publicly available standardized framework for the evaluation of (semi)automatic methods for CAC identification in cardiac CT is described. An evaluation of five (semi)automatic methods within this framework shows that automatic per patient CVD risk categorization is feasible. CAC lesions at ambiguous locations such as the coronary ostia remain challenging, but their detection had limited impact on CVD risk determination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
2013 ACC/AHA Guideline on the Assessment of Cardiovascular Risk
Goff, D. C., Lloyd-Jones, D. M., Bennett, G., Coady, S., D’Agostino, R. B., Gibbons, R., Greenland, P., Lackland, D. T., Levy, D., O’Donnell, C. J., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.11.005 · Cited by 4,945
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311 · cited 3×
“28 The heart and aorta segmentations were transformed to the test CCTA scan.”
Self-citationCoronary Calcium as a Predictor of Coronary Events in Four Racial or Ethnic Groups
Detrano, R., Guerci, A. D., Carr, J. J., Bild, D. E., Burke, G., Folsom, A. R., Liu, K., Shea, S., Szklo, M., Bluemke, D. A., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa072100 · Cited by 2,989 · cited 1×
“The detection of CAC lesions was evaluated using sensitivity, positive predictive value (PPV) and the F 1 score, i.e., the harmonic average of sensitivity and PPV [2 · ( sensitivity · PPV ) / ( sensitivity + PPV ) ], weighted by both the total number and total volume of lesions in the test set.”
Yeboah, J., McClelland, R. L., Polonsky, T. S., Burke, G. L., Sibley, C. T., O’Leary, D., Carr, J. J., Goff, D. C., Greenland, P., & Herrington, D. M. (2012) · JAMA · doi:10.1001/jama.2012.9624 · Cited by 1,122
Cited by
State-of-the-Art Deep Learning in Cardiovascular Image Analysis
Litjens, G., Ciompi, F., Wolterink, J. M., de Vos, B. D., Leiner, T., Teuwen, J., & Išgum, I. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.06.009 · Cited by 388
Self-citationWolterink, J. M., Leiner, T., de Vos, B. D., van Hamersvelt, R. W., Viergever, M. A., & Išgum, I. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.04.004 · Cited by 321
Self-citationKuijf, H. J., Casamitjana, A., Collins, D. L., Dadar, M., Georgiou, A., Ghafoorian, M., Jin, D., Khademi, A., Knight, J., Li, H., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2905770 · Cited by 292
Self-citationZreik, M., van Hamersvelt, R. W., Wolterink, J. M., Leiner, T., Viergever, M. A., & Isgum, I. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2883807 · Cited by 282
Self-citationWolterink, J. M., van Hamersvelt, R. W., Viergever, M. A., Leiner, T., & Išgum, I. (2019) · Medical Image Analysis · doi:10.1016/j.media.2018.10.005 · Cited by 207
Self-citationGala, D., Behl, H., Shah, M., & Makaryus, A. N. (2024) · Healthcare · doi:10.3390/healthcare12040481 · Cited by 183
Direct Automatic Coronary Calcium Scoring in Cardiac and Chest CT
de Vos, B. D., Wolterink, J. M., Leiner, T., de Jong, P. A., Lessmann, N., & Isgum, I. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2899534 · Cited by 134
“We evaluated our method on data from the orCaScore challenge [25].”
MethodSelf-citationEvaluation of a Deep Learning–Based Automated CT Coronary Artery Calcium Scoring Algorithm
Martin, S. S., van Assen, M., Rapaka, S., Hudson, H. T., Fischer, A. M., Varga-Szemes, A., Sahbaee, P., Schwemmer, C., Gulsun, M. A., Cimen, S., et al. (2020) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.09.015 · Cited by 75
Shadmi, R., Mazo, V., Bregman-Amitai, O., & Elnekave, E. (2018) · 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018) · doi:10.1109/isbi.2018.8363515 · Cited by 59
“The orCaScore challenge [18] offers a public dataset to evaluate algorithms for CCS.”
Method
Metadata
- Authors
- Wolterink, J. M., Leiner, T., de Vos, B. D., Coatrieux, J.-L., Kelm, B. M., Kondo, S., Salgado, R. A., Shahzad, R., Shu, H., Snoeren, M., Takx, R. A. P., van Vliet, L. J., van Walsum, T., Willems, T. P., Yang, G., Zheng, Y., Viergever, M. A., & Išgum, I.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2016-04-13
- Volume
- 43
- Issue
- 5
- Pages
- 2361-2373
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2340907062
- Cited by
- 99
- References
- 5
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.