CoChat

Ultraflexible organic photonic skin

Open access

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Abstract

Optoelectronic electronic skins, or e-skins, introduce electronic sensing and displays on the surface of human skin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.1501856

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Smart e-skin system comprising health-monitoring sensors, displays, and ultraflexible PLEDs. (A) Schematic illustration of the optoelectronic skins (oe-skins) system. (B) Photograph of a finger with the ultraflexible organic optical sensor attached. (C) Photographs of a human face with a blue logo of the University of Tokyo and a two-color logo. The brightness can be changed by the operation voltage. (D) Photograph of a red seven-segment PLEDs displayed on a hand.
Fig. 1 Smart e-skin system comprising health-monitoring sensors, displays, and ultraflexible PLEDs. (A) Schematic illustration of the optoelectronic skins (oe-skins) system. (B) Photograph of a finger with the ultraflexible organic optical sensor attached. (C) Photographs of a human face with a blue logo of the University of Tokyo and a two-color logo. The brightness can be changed by the operation voltage. (D) Photograph of a red seven-segment PLEDs displayed on a hand.CC BY-NC · PubMed Central
Fig. 2 Characteristics of ultraflexible PLEDs and OPDs. Note that all the measurements were performed in air. (A) Structure of the ultraflexible PLED. The passivation layer was composed of alternating organic (500-nm-thick Parylene) and inorganic (200-nm-thick SiON) layers. (B) Picture of the ultraflexible green PLED that was crumpled. (C) The EQE of the OPD (black line) with the normalized electroluminescence (EL) spectra of blue (blue line), green (green line), and red (red line) PLEDs. a.u., arbitrary unit. (D) Current density–dependent EQE characteristics of the ultraflexible PLEDs. The inset figure shows L-V curves of ultraflexible PLEDs. (E) Picture of the freestanding ultraflexible OPD. (F) Light intensity–dependent J-V characteristics of the OPD under simulated solar illumination. Red, orange, green, light blue, blue, purple, gray, and black represent the light intensity of 1000, 706, 502, 400, 297, 199, and 99 W/m2 and the dark condition, respectively. (G) Characteristics of the ultraflexible OPD, measured using a solar simulator. Light intensity–dependent Voc of the OPD (red) and light intensity–dependent Jsc of the OPD (green).
Fig. 2 Characteristics of ultraflexible PLEDs and OPDs. Note that all the measurements were performed in air. (A) Structure of the ultraflexible PLED. The passivation layer was composed of alternating organic (500-nm-thick Parylene) and inorganic (200-nm-thick SiON) layers. (B) Picture of the ultraflexible green PLED that was crumpled. (C) The EQE of the OPD (black line) with the normalized electroluminescence (EL) spectra of blue (blue line), green (green line), and red (red line) PLEDs. a.u., arbitrary unit. (D) Current density–dependent EQE characteristics of the ultraflexible PLEDs. The inset figure shows L-V curves of ultraflexible PLEDs. (E) Picture of the freestanding ultraflexible OPD. (F) Light intensity–dependent J-V characteristics of the OPD under simulated solar illumination. Red, orange, green, light blue, blue, purple, gray, and black represent the light intensity of 1000, 706, 502, 400, 297, 199, and 99 W/m2 and the dark condition, respectively. (G) Characteristics of the ultraflexible OPD, measured using a solar simulator. Light intensity–dependent Voc of the OPD (red) and light intensity–dependent Jsc of the OPD (green).CC BY-NC · PubMed Central
Fig. 3 Demonstrations of extreme flexibility of ultrathin optical devices. (A) Images of an ultrathin red PLED adhered to a prestretched elastomer. The images from right to left represent the transition from the wrinkled state to the flat state. (B) Three-dimensional image of the wrinkled PLED state. The prestretch value was 60%. (C) Cyclic stretching test of the green PLED. After 1000 stretching cycle tests, the light intensity was decreased by only 10%. (D) Voc of the wrinkled OPD. The inset figure shows the flat and compressed OPD. (E) Cyclic stretching test of the OPD. After 300 stretching cycle tests, the characteristics did not show any degradation. The black circles and red triangles represent the Voc and normalized Jsc, respectively. The inset figure shows the J-V characteristics of the OPD (dot line, dark state; solid line, irradiated by green light). Black and red lines represent the initial state and the state after 300 stretching cycles, respectively.
Fig. 3 Demonstrations of extreme flexibility of ultrathin optical devices. (A) Images of an ultrathin red PLED adhered to a prestretched elastomer. The images from right to left represent the transition from the wrinkled state to the flat state. (B) Three-dimensional image of the wrinkled PLED state. The prestretch value was 60%. (C) Cyclic stretching test of the green PLED. After 1000 stretching cycle tests, the light intensity was decreased by only 10%. (D) Voc of the wrinkled OPD. The inset figure shows the flat and compressed OPD. (E) Cyclic stretching test of the OPD. After 300 stretching cycle tests, the characteristics did not show any degradation. The black circles and red triangles represent the Voc and normalized Jsc, respectively. The inset figure shows the J-V characteristics of the OPD (dot line, dark state; solid line, irradiated by green light). Black and red lines represent the initial state and the state after 300 stretching cycles, respectively.CC BY-NC · PubMed Central
Fig. 4 Ultraflexible organic pulse oximeter. (A) Device structure of the pulse oximeter. (B) Operation principle of the reflective pulse oximeter. (C) Light intensity–dependent J-V characteristics of the OPD when irradiated by a green PLED. (D) Light intensity–dependent J-V characteristics of the OPD when irradiated by a red PLED. (E) Long-term measurement of the pulse wave. The pulse wave was measured using a red PLED and OPD. (F) Air stability of the PPG signal. The PPG signal was measured using a red PLED and OPD. (G) Output signal from OPD with 99% oxygenation of blood. The green and red lines represent the signals when the green and red PLEDs, respectively, were operated. (H) Output signal from OPD with 90% of oxygenation of blood. The green and red lines represent the signals when the green and red PLEDs, respectively, were operated.
Fig. 4 Ultraflexible organic pulse oximeter. (A) Device structure of the pulse oximeter. (B) Operation principle of the reflective pulse oximeter. (C) Light intensity–dependent J-V characteristics of the OPD when irradiated by a green PLED. (D) Light intensity–dependent J-V characteristics of the OPD when irradiated by a red PLED. (E) Long-term measurement of the pulse wave. The pulse wave was measured using a red PLED and OPD. (F) Air stability of the PPG signal. The PPG signal was measured using a red PLED and OPD. (G) Output signal from OPD with 99% oxygenation of blood. The green and red lines represent the signals when the green and red PLEDs, respectively, were operated. (H) Output signal from OPD with 90% of oxygenation of blood. The green and red lines represent the signals when the green and red PLEDs, respectively, were operated.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 1,024

Metadata

Authors
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T.
Affiliations
The University of Tokyo (JP)
Corresponding author
  • Yokota, Tomoyuki
  • Kaltenbrunner, Martin
  • Someya, Takao
Venue
Science Advances
Published
2016-04
Volume
2
Issue
4
Pages
e1501856-e1501856
ISSN
2375-2548 (ISSN-L)
OpenAlex
W2339545839
Cited by
1,024
References
44
Citations by year
2026: 52 · 2025: 77 · 2024: 107 · 2023: 97 · 2022: 91 · 2021: 134 · 2020: 126 · 2019: 128 · 2018: 122 · 2017: 65 · 2016: 25
FWCI
54.64
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Funders
The JST/ERATO Someya Bio-harmonized electronics project (ID0EICBI6448)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Organic Electronics and Photovoltaics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Organic Light-Emitting Diodes Research
Keywords
polymer light-emitting diodes, organic photodetectors, wearable devices, pulse oximetry, thin-film electronics
MeSH terms
Humans, Light, Skin, Surface Properties, Transistors, Electronic, Photons

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.