CoChat

Glove-based sensors for multimodal monitoring of natural sweat

Open access

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Abstract

Functionalized glove sensors allow natural sweat analysis without requiring exercise or iontophoretic stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.abb8308

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Glove-based analytics for natural sweat analysis. (A) Glove-based sensors, including functionalized gloves and cots allow natural sweat analysis during sedentary and routine activity without active sweat stimulation. (B) Electrochemical sensors can be fabricated on versatile glove positions such as the back of the hand to target high sweat rate sites. The glove’s nitrile material crucially protects against evaporation for rapid sweat accumulation. (C) Nitrile cots can be functionalized to target sweat gland-rich fingertips while offering a condensed form factor. (D) Cross-sectional schematic of the sensing layers and measurement schemes for zinc, ethanol, pH, and chloride sensors functionalized on a nitrile glove, and (E) vitamin C sensor functionalized on a nitrile cot.
Fig. 1 Glove-based analytics for natural sweat analysis. (A) Glove-based sensors, including functionalized gloves and cots allow natural sweat analysis during sedentary and routine activity without active sweat stimulation. (B) Electrochemical sensors can be fabricated on versatile glove positions such as the back of the hand to target high sweat rate sites. The glove’s nitrile material crucially protects against evaporation for rapid sweat accumulation. (C) Nitrile cots can be functionalized to target sweat gland-rich fingertips while offering a condensed form factor. (D) Cross-sectional schematic of the sensing layers and measurement schemes for zinc, ethanol, pH, and chloride sensors functionalized on a nitrile glove, and (E) vitamin C sensor functionalized on a nitrile cot.CC BY-NC · PubMed Central
Fig. 2 Comparative sweat gland densities across body locations. (A) Sweat glands are imaged with bromophenol blue on the finger, palm, back of hand, wrist, and forearm. Sweat glands on the forehead and neck are imaged by imprinting onto iodine patches. Blue squares indicate locations of the sampled densities. Sweat gland images share the same scale. (B) Sweat gland densities are found by counting glands in the images from (A) across body sites for five subjects. A unique color is used for each subject. Photo credit: Mallika Bariya, University of California, Berkeley.
Fig. 2 Comparative sweat gland densities across body locations. (A) Sweat glands are imaged with bromophenol blue on the finger, palm, back of hand, wrist, and forearm. Sweat glands on the forehead and neck are imaged by imprinting onto iodine patches. Blue squares indicate locations of the sampled densities. Sweat gland images share the same scale. (B) Sweat gland densities are found by counting glands in the images from (A) across body sites for five subjects. A unique color is used for each subject. Photo credit: Mallika Bariya, University of California, Berkeley.CC BY-NC · PubMed Central
Fig. 3 Sweat volumes accumulated during routine activity. (A) Sweat accumulated in glove during 30 min of routine activity for (B) to (D). (B) Sweat collected from right (red) and left (gray) gloved hands for 12 subjects (6 male and 6 female) while sitting under ambient indoor conditions near 65°F. (C) Sweat accumulated from six subjects at different activity levels (three male and three female) shows a generally increasing sweat rate with activity level. (D) Sweat accumulated from six subjects over a range of ambient temperatures while sitting indicates a rough increase in sweat rate with temperature. (E) Sweat accumulated in finger cot for 30 min for (F). (F) Finger cots worn on each finger for four subjects (two males and two females, each designated a different color) show slightly higher sweat volume accumulated on the thumb and slightly lower volume on the pinky, roughly scaling with finger surface area. Photo credit: Lu Li, University of California, Berkeley.
Fig. 3 Sweat volumes accumulated during routine activity. (A) Sweat accumulated in glove during 30 min of routine activity for (B) to (D). (B) Sweat collected from right (red) and left (gray) gloved hands for 12 subjects (6 male and 6 female) while sitting under ambient indoor conditions near 65°F. (C) Sweat accumulated from six subjects at different activity levels (three male and three female) shows a generally increasing sweat rate with activity level. (D) Sweat accumulated from six subjects over a range of ambient temperatures while sitting indicates a rough increase in sweat rate with temperature. (E) Sweat accumulated in finger cot for 30 min for (F). (F) Finger cots worn on each finger for four subjects (two males and two females, each designated a different color) show slightly higher sweat volume accumulated on the thumb and slightly lower volume on the pinky, roughly scaling with finger surface area. Photo credit: Lu Li, University of California, Berkeley.CC BY-NC · PubMed Central
Fig. 4 Electrochemical characterization of glove-based sensors. (A) Gold electrodes are evaporated on the inner glove surface and functionalized with sensing layers to target zinc, ethanol, pH, and chloride ions in sweat. Calibration curves in buffer solutions of different analyte concentrations are shown for (B) ethanol, (C) Zn, (D) pH, and (E) chloride. (F) three-electrode system on the inside of a finger cot composed of evaporated gold functionalized with sensing materials to detect vitamin C. (G) Calibration curve of vitamin C sensor in buffer solutions. Photo credit: Lu Li, University of California, Berkeley.
Fig. 4 Electrochemical characterization of glove-based sensors. (A) Gold electrodes are evaporated on the inner glove surface and functionalized with sensing layers to target zinc, ethanol, pH, and chloride ions in sweat. Calibration curves in buffer solutions of different analyte concentrations are shown for (B) ethanol, (C) Zn, (D) pH, and (E) chloride. (F) three-electrode system on the inside of a finger cot composed of evaporated gold functionalized with sensing materials to detect vitamin C. (G) Calibration curve of vitamin C sensor in buffer solutions. Photo credit: Lu Li, University of California, Berkeley.CC BY-NC · PubMed Central
Fig. 5 Characterization of electrode robustness under mechanical deformation. (A) Resistance of an 8-cm evaporated Au electrode on the nitrile glove is measured between 0 and 15% strain. Red star shows relaxed electrode resistance once 15% strain is removed. (B) Resistance of the 8-cm electrode is measured at the relaxed state after 0, 1, 5, 10, 20, 50, and 100 cycles of 2% applied strain, showing that the electrode consistently recovers even after multiple distortions. (C) The electrode is exposed to a series of distortions, including folding, twisting, and stretching (via 2% strain). Stretching/strain has the most pronounced impact on the electrode resistance during the distortion, but the electrode closely recovers to the original resistance of its relaxed state after each deformation. (D) A representative chloride sensor on the glove is calibrated while strained and folded. The distortions do not substantially affect the sensor signal. Photo credit: Lu Li, University of California, Berkeley.
Fig. 5 Characterization of electrode robustness under mechanical deformation. (A) Resistance of an 8-cm evaporated Au electrode on the nitrile glove is measured between 0 and 15% strain. Red star shows relaxed electrode resistance once 15% strain is removed. (B) Resistance of the 8-cm electrode is measured at the relaxed state after 0, 1, 5, 10, 20, 50, and 100 cycles of 2% applied strain, showing that the electrode consistently recovers even after multiple distortions. (C) The electrode is exposed to a series of distortions, including folding, twisting, and stretching (via 2% strain). Stretching/strain has the most pronounced impact on the electrode resistance during the distortion, but the electrode closely recovers to the original resistance of its relaxed state after each deformation. (D) A representative chloride sensor on the glove is calibrated while strained and folded. The distortions do not substantially affect the sensor signal. Photo credit: Lu Li, University of California, Berkeley.CC BY-NC · PubMed Central
Fig. 6 On-body multiglove study of natural sweat analyte dynamics. (A) Subject introduces alcohol into the body by drinking wine, and subsequent excretion of alcohol in natural sweat is studied using the glove-based sensing platform. (B) Time 0 indicates when alcohol consumption is finished. (i) Alcohol intake versus time. (ii) BAC as measured by a breathalyzer. (iii) Natural sweat alcohol concentration is tracked over a 6-hour period using 10 gloves, with each glove providing an average alcohol concentration measurement for the 30-min time period over which it was worn. Each glove’s measurement is indicated by a red point at the end of the 30-min interval. (C) Subject consumes 1000 mg of vitamin C dissolved in water each day for 5 days, and the resulting vitamin C that emerges in natural sweat is tracked using functionalized finger cots. (D) Natural sweat vitamin C concentration is plotted with red dots (each representing a measurement by one finger cot 30 min of accumulated sweat) over 5 days. Daily peaking behavior demonstrates the competing adsorption and metabolism mechanisms typical of xenobiotics in the body. Dashed blue lines indicate time of vitamin C intake. Photo credit: Lu Li, University of California, Berkeley.
Fig. 6 On-body multiglove study of natural sweat analyte dynamics. (A) Subject introduces alcohol into the body by drinking wine, and subsequent excretion of alcohol in natural sweat is studied using the glove-based sensing platform. (B) Time 0 indicates when alcohol consumption is finished. (i) Alcohol intake versus time. (ii) BAC as measured by a breathalyzer. (iii) Natural sweat alcohol concentration is tracked over a 6-hour period using 10 gloves, with each glove providing an average alcohol concentration measurement for the 30-min time period over which it was worn. Each glove’s measurement is indicated by a red point at the end of the 30-min interval. (C) Subject consumes 1000 mg of vitamin C dissolved in water each day for 5 days, and the resulting vitamin C that emerges in natural sweat is tracked using functionalized finger cots. (D) Natural sweat vitamin C concentration is plotted with red dots (each representing a measurement by one finger cot 30 min of accumulated sweat) over 5 days. Daily peaking behavior demonstrates the competing adsorption and metabolism mechanisms typical of xenobiotics in the body. Dashed blue lines indicate time of vitamin C intake. Photo credit: Lu Li, University of California, Berkeley.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 50 references

Research works printed but not linked: 1

  1. Benet L. Z., Kroetz D., Sheiner L., Hardman J., Limbird L., Pharmacokinetics: The dynamics of drug absorption, distribution, metabolism, and elimination. Goodman Gilman’s Pharmacol. Basis Ther. 3, e27 (1996).

Cited by

See all 154

Metadata

Authors
Bariya, M., Li, L., Ghattamaneni, R., Ahn, C. H., Nyein, H. Y. Y., Tai, L.-C., & Javey, A.
Affiliations
  • Lawrence Berkeley National Laboratory (US)
  • University of California, Berkeley (US)
Corresponding author
  • Bariya, Mallika
  • Li, Lu
  • Javey, Ali
Venue
Science Advances
Published
2020-08-28
Volume
6
Issue
35
Pages
eabb8308-eabb8308
ISSN
2375-2548 (ISSN-L)
OpenAlex
W3082300378
Cited by
154
References
50
Citations by year
2026: 15 · 2025: 26 · 2024: 28 · 2023: 28 · 2022: 29 · 2021: 26 · 2020: 2
FWCI
6.68
Type
journal article
Language
en
Open access
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
  • Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion, cc-by-nc)
Funders
  • Bakar fellowship
  • NSF Nanomanufacturing Systems for Mobile Computing and Mobile Energy Technologies
  • Berkeley Sensor and Actuator Center
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
sweat collection, sweat biomarkers, electrolytes, xenobiotics, non-invasive health monitoring, wearable sensors, nitrile gloves, sweat evaporation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.