The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Wearable microneedle-based electrochemical aptamer biosensing for precision dosing of drugs with narrow therapeutic windows
Open accessAbstract
Therapeutic drug monitoring is essential for dosing pharmaceuticals with narrow therapeutic windows. Nevertheless, standard methods are imprecise and involve invasive/resource-intensive procedures with long turnaround times. Overcoming these limitations, we present a microneedle-based electrochemical aptamer biosensing patch (μNEAB-patch) that minimally invasively probes the interstitial fluid (ISF) and renders correlated, continuous, and real-time measurements of the circulating drugs’ pharmacokinetics. The μNEAB-patch is created following an introduced low-cost fabrication scheme, which transforms a shortened clinical-grade needle into a high-quality gold nanoparticle-based substrate for robust aptamer immobilization and efficient electrochemical signal retrieval. This enables the reliable in vivo detection of a wide library of ISF analytes—especially those with nonexistent natural recognition elements. Accordingly, we developed μNEABs targeting various drugs, including antibiotics with narrow therapeutic windows (tobramycin and vancomycin). Through in vivo animal studies, we demonstrated the strong correlation between the ISF/circulating drug levels and the device’s potential clinical use for timely prediction of total drug exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trypan Blue Exclusion Test of Cell Viability
Strober, W. (2015) · Current Protocols in Immunology · doi:10.1002/0471142735.ima03bs111 · Cited by 2,597
Rybak, M., Lomaestro, B., Rotschafer, J. C., Moellering, R., Craig, W., Billeter, M., Dalovisio, J. R., & Levine, D. P. (2009) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp080434 · Cited by 1,795
Trypan Blue Exclusion Test of Cell Viability
Strober, W. (1997) · Current Protocols in Immunology · doi:10.1002/0471142735.ima03bs21 · Cited by 1,345
Label‐Free Electronic Detection of Thrombin in Blood Serum by Using an Aptamer‐Based Sensor
Xiao, Y., Lubin, A. A., Heeger, A. J., & Plaxco, K. W. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500989 · Cited by 812
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Quantifying thiol–gold interactions towards the efficient strength control
Xue, Y., Li, X., Li, H., & Zhang, W. (2014) · Nature Communications · doi:10.1038/ncomms5348 · Cited by 738
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Real-time measurement of small molecules directly in awake, ambulatory animals
Arroyo-Currás, N., Somerson, J., Vieira, P. A., Ploense, K. L., Kippin, T. E., & Plaxco, K. W. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1613458114 · Cited by 451
Xiao, Y., Lai, R. Y., & Plaxco, K. W. (2007) · Nature Protocols · doi:10.1038/nprot.2007.413 · Cited by 439
Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Teymourian, H., Parrilla, M., Sempionatto, J. R., Montiel, N. F., Barfidokht, A., Van Echelpoel, R., De Wael, K., & Wang, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01318 · Cited by 423
Real-Time, Aptamer-Based Tracking of Circulating Therapeutic Agents in Living Animals
Ferguson, B. S., Hoggarth, D. A., Maliniak, D., Ploense, K., White, R. J., Woodward, N., Hsieh, K., Bonham, A. J., Eisenstein, M., Kippin, T. E., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007095 · Cited by 419
Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid
Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., Rathi, P., Wang, Y., Cao, S., Jiang, Q., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00672-y · Cited by 386
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Samant, P. P., & Prausnitz, M. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716772115 · Cited by 363
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Dauphin-Ducharme, P., Yang, K., Arroyo-Currás, N., Ploense, K. L., Zhang, Y., Gerson, J., Kurnik, M., Kippin, T. E., Stojanovic, M. N., & Plaxco, K. W. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01616 · Cited by 280
Aptamers as molecular recognition elements for electrical nanobiosensors
Lee, J.-O., So, H.-M., Jeon, E.-K., Chang, H., Won, K., & Kim, Y. H. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1643-y · Cited by 277
Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays
Mohan, A. M. V., Windmiller, J. R., Mishra, R. K., & Wang, J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.016 · Cited by 274
On-Site Therapeutic Drug Monitoring
Ates, H. C., Roberts, J. A., Lipman, J., Cass, A. E. G., Urban, G. A., & Dincer, C. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.03.001 · Cited by 268
Mechanism of fluid infusion during microneedle insertion and retraction
Martanto, W., Moore, J. S., Couse, T., & Prausnitz, M. R. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.02.017 · Cited by 250
Mohanty, U. S. (2011) · Journal of Applied Electrochemistry · doi:10.1007/s10800-010-0234-3 · Cited by 245
Continuous Opioid Monitoring along with Nerve Agents on a Wearable Microneedle Sensor Array
Mishra, R. K., Goud, K. Y., Li, Z., Moonla, C., Mohamed, M. A., Tehrani, F., Teymourian, H., & Wang, J. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c01883 · Cited by 238
Li, H., Dauphin-Ducharme, P., Ortega, G., & Plaxco, K. W. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b05412 · Cited by 233
Microneedle Aptamer-Based Sensors for Continuous, Real-Time Therapeutic Drug Monitoring
Wu, Y., Tehrani, F., Teymourian, H., Mack, J., Shaver, A., Reynoso, M., Kavner, J., Huang, N., Furmidge, A., Duvvuri, A., et al. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00829 · Cited by 212
Wearable All-Solid-State Potentiometric Microneedle Patch for Intradermal Potassium Detection
Parrilla, M., Cuartero, M., Padrell Sánchez, S., Rajabi, M., Roxhed, N., Niklaus, F., & Crespo, G. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04877 · Cited by 209
Carvalhal, R. F., Sanches Freire, R., & Kubota, L. T. (2005) · Electroanalysis · doi:10.1002/elan.200403224 · Cited by 199
Tobramycin: A Review of its Antibacterial and Pharmacokinetic Properties and Therapeutic Use
Brogden, R. N., Pinder, R. M., Sawyer, P. R., Speight, T. M., & Avery, G. S. (1976) · Drugs · doi:10.2165/00003495-197612030-00002 · Cited by 195
Rawson, T. M., Gowers, S. A. N., Freeman, D. M. E., Wilson, R. C., Sharma, S., Gilchrist, M., MacGowan, A., Lovering, A., Bayliss, M., Kyriakides, M., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30131-1 · Cited by 180
Clinical Use of Ibuprofen Is Associated with Slower FEV 1 Decline in Children with Cystic Fibrosis
Konstan, M. W., Schluchter, M. D., Xue, W., & Davis, P. B. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200702-181oc · Cited by 178
Wearable Sweat Band for Noninvasive Levodopa Monitoring
Tai, L.-C., Liaw, T. S., Lin, Y., Nyein, H. Y. Y., Bariya, M., Ji, W., Hettick, M., Zhao, C., Zhao, J., Hou, L., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02478 · Cited by 177
Leung, K. K., Downs, A. M., Ortega, G., Kurnik, M., & Plaxco, K. W. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01183 · Cited by 166
Time Delay of CGM Sensors: Relevance, Causes, and Countermeasures
Schmelzeisen-Redeker, G., Schoemaker, M., Kirchsteiger, H., Freckmann, G., Heinemann, L., & del Re, L. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815590154 · Cited by 161
Arroyo‐Currás, N., Scida, K., Ploense, K. L., Kippin, T. E., & Plaxco, K. W. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02830 · Cited by 160
A wearable freestanding electrochemical sensing system
Zhao, Y., Wang, B., Hojaiji, H., Wang, Z., Lin, S., Yeung, C. J., Lin, H., Nguyen, P., Chiu, K., Salahi, K., et al. (2020) · Science Advances · doi:10.1126/sciadv.aaz0007 · Cited by 145
Self-citationFrom the beaker to the body: translational challenges for electrochemical, aptamer-based sensors
Arroyo‐Currás, N., Dauphin‐Ducharme, P., Scida, K., & Chávez, J. L. (2020) · Analytical Methods · doi:10.1039/d0ay00026d · Cited by 135
Closed-loop control of circulating drug levels in live animals
(2017) · doi:10.1038/s41551-017-0070 · Cited by 130
A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring
Sharma, S., El-Laboudi, A. H., Reddy, M., Jugnee, N., Sivasubramaniyam, S., Sharkawy, M. E., Georgiou, P., Johnston, D. G., Oliver, N. S., & Cass, A. E. G. (2018) · Analytical Methods · doi:10.1039/c8ay00264a · Cited by 125
Noninvasive wearable electroactive pharmaceutical monitoring for personalized therapeutics
Lin, S., Yu, W., Wang, B., Zhao, Y., En, K., Zhu, J., Cheng, X., Zhou, C., Lin, H., Wang, Z., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2009979117 · Cited by 117
Self-citationA Review: Electrode and Packaging Materials for Neurophysiology Recording Implants
Yang, W., Gong, Y. P., & Li, W. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.622923 · Cited by 113
Real-time monitoring of drug pharmacokinetics within tumor tissue in live animals
Seo, J.-W., Fu, K. X., Correa, S., Eisenstein, M. S., Appel, E. A., & Soh, H. T. (2022) · Science Advances · doi:10.1126/sciadv.abk2901 · Cited by 108
Nanoporous Gold for the Miniaturization of In Vivo Electrochemical Aptamer-Based Sensors
Downs, A. M., Gerson, J. O., Hossain, M. N., Ploense, K. L., Pham, M., Kraatz, H., Kippin, T. E., & Plaxco, K. W. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00354 · Cited by 107
High-Precision Control of Plasma Drug Levels Using Feedback-Controlled Dosing
Arroyo‐Currás, N., Ortega, G., Copp, D. A., Ploense, K. L., Plaxco, Z. A., Kippin, T. E., Hespanha, J. P., & Plaxco, K. W. (2018) · ACS Pharmacology & Translational Science · doi:10.1021/acsptsci.8b00033 · Cited by 106
Rajabi, M., Roxhed, N., Shafagh, R. Z., Haraldson, T., Fischer, A. C., van der Wijngaart, W., Stemme, G., & Niklaus, F. (2016) · PLoS ONE · doi:10.1371/journal.pone.0166330 · Cited by 105
Pharmacokinetics of antibiotics in tissues and tissue fluids: a review.
Cars, O. (1990) · PubMed · Cited by 87
Yi, K., Wang, Y., Shi, K., Chi, J., Lyu, J., & Zhao, Y. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113404 · Cited by 86
Self-citationLee, W., Jeong, S., Lim, Y., Lee, H., Kang, J., Lee, H., Lee, I., Han, H., Kobayashi, S., Tanaka, M., et al. (2021) · Science Advances · doi:10.1126/sciadv.abi6290 · Cited by 86
Acute Kidney Injury and Renal Recovery with the Use of Aminoglycosides: A Large Retrospective Study
Paquette, F., Bernier-Jean, A., Brunette, V., Ammann, H., Lavergne, V., Pichette, V., Troyanov, S., & Bouchard, J. (2015) · The Nephron journals/Nephron journals · doi:10.1159/000440867 · Cited by 80
Nick, J. A., Moskowitz, S. M., Chmiel, J. F., Forssén, A. V., Kim, S. H., Saavedra, M. T., Saiman, L. M., Taylor‐Cousar, J. L., & Nichols, D. P. (2014) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201310-352oc · Cited by 73
Cao, J. P., Su, J., An, M., Yang, Y., Zhang, Y., Zuo, J., Zhang, N., & Zhao, Y. (2020) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.0c00954 · Cited by 71
Self-citationKolluru, C., Williams, M., Yeh, J. S., Noel, R. K., Knaack, J. S., & Prausnitz, M. R. (2019) · Biomedical Microdevices · doi:10.1007/s10544-019-0363-3 · Cited by 69
Yáñez‐Sedeño, P., Campuzano, S., & Pingarrón, J. M. (2019) · Chemical Communications · doi:10.1039/c8cc08815b · Cited by 65
Vieira, P. A., Shin, C., Arroyo‐Currás, N., Ortega, G., Li, W., Keller, A. A., Plaxco, K. W., & Kippin, T. E. (2019) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2019.00069 · Cited by 38
Liang, S., Han, Y., Zhang, W., Zhong, T., Guan, H., Song, Y., Zhang, Y., Xing, L., Xue, X., Li, G., et al. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.106851 · Cited by 27
Brockmeyer, J. M., Wise, R. T., Burgener, E. B., Milla, C. E., & Frymoyer, A. R. (2020) · Pediatric Pulmonology · doi:10.1002/ppul.25037 · Cited by 17
Self-citationKoch, B. C. P., Muller, A. E., Hunfeld, N., de Winter, B. C. M., Ewoldt, T. M. J., Abdulla, A., & Endeman, H. (2021) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000942 · Cited by 12
Lee, B. V., Fong, G. R., Bolaris, M., Neely, M. N., Minejima, E., Kang, A. Y., Lee, G., & Gong, C. L. (2021) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2021.01.015 · Cited by 11
Determining Genome-wide Transcript Decay Rates in Proliferating and Quiescent Human Fibroblasts
Mitra, M., Lee, H. N., & Coller, H. A. (2018) · Journal of Visualized Experiments · doi:10.3791/56423 · Cited by 4
Self-citation
Cited by
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
A physicochemical-sensing electronic skin for stress response monitoring
Xu, C., Song, Y., Sempionatto, J. R., Solomon, S. A., Yu, Y., Nyein, H. Y. Y., Tay, R. Y., Li, J., Heng, W., Min, J., et al. (2024) · Nature Electronics · doi:10.1038/s41928-023-01116-6 · Cited by 399
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Artificial intelligence-powered electronic skin
Xu, C., Solomon, S. A., & Gao, W. (2023) · Nature Machine Intelligence · doi:10.1038/s42256-023-00760-z · Cited by 259
Metadata
- Authors
- Lin, S., Cheng, X., Zhu, J., Wang, B., Jelinek, D., Zhao, Y., Wu, T.-Y., Horrillo, A., Tan, J., Yeung, J., Yan, W., Forman, S., Coller, H. A., Milla, C., & Emaminejad, S.
- Venue
- Science Advances
- Published
- 2022-09-23
- Volume
- 8
- Issue
- 38
- Pages
- eabq4539-eabq4539
- ISSN
- 2375-2548 (ISSN-L)
- OpenAlex
- W4296844341
- Cited by
- 255
- References
- 56
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.