The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Multistep Synthesis of a Radiolabeled Imaging Probe Using Integrated Microfluidics
Abstract
Microreactor technology has shown potential for optimizing synthetic efficiency, particularly in preparing sensitive compounds. We achieved the synthesis of an [ 18 F]fluoride-radiolabeled molecular imaging probe, 2-deoxy-2-[ 18 F]fluoro- d -glucose ([ 18 F]FDG), in an integrated microfluidic device. Five sequential processes—[ 18 F]fluoride concentration, water evaporation, radiofluorination, solvent exchange, and hydrolytic deprotection—proceeded with high radio-chemical yield and purity and with shorter synthesis time relative to conventional automated synthesis. Multiple doses of [ 18 F]FDG for positron emission tomography imaging studies in mice were prepared. These results, which constitute a proof of principle for automated multistep syntheses at the nanogram to microgram scale, could be generalized to a range of radiolabeled substrates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Self-citationHamacher, K., Coenen, H. H., & Stöcklin, G. (1986) · PubMed · Cited by 1,351
Chemistry in Microstructured Reactors
Jähnisch, K., Hessel, V., Löwe, H., & Baerns, M. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200300577 · Cited by 1,286
Positron emission tomography provides molecular imaging of biological processes
Phelps, M. E. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.16.9226 · Cited by 1,229
Self-citationA Microfluidic Device for Conducting Gas-Liquid-Solid Hydrogenation Reactions
Kobayashi, J., Mori, Y., Okamoto, K., Akiyama, R., Ueno, M., Kitamori, T., & Kobayashi, S. (2004) · Science · doi:10.1126/science.1096956 · Cited by 576
A nanoliter-scale nucleic acid processor with parallel architecture
Hong, J. W., Studer, V., Hang, G., Anderson, W. F., & Quake, S. R. (2004) · Nature Biotechnology · doi:10.1038/nbt951 · Cited by 470
Self-citationMicro reactors: principles and applications in organic synthesis
Fletcher, P. D. I., Haswell, S. J., Pombo-Villar, E., Warrington, B. H., Watts, P., Wong, S. Y. F., & Zhang, X. (2002) · Tetrahedron · doi:10.1016/s0040-4020(02)00432-5 · Cited by 468
Solvent-Resistant Photocurable “Liquid Teflon” for Microfluidic Device Fabrication
Rolland, J. P., Van Dam, R. M., Schorzman, D. A., Quake, S. R., & DeSimone, J. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031657y · Cited by 440
Self-citationSize-Controlled Growth of CdSe Nanocrystals in Microfluidic Reactors
Chan, E. M., Mathies, R. A., & Alivisatos, A. P. (2003) · Nano Letters · doi:10.1021/nl0259481 · Cited by 325
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
Ametamey, S. M., Honer, M., & Schubiger, P. A. (2008) · Chemical Reviews · doi:10.1021/cr0782426 · Cited by 1,271
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Continuous-flow lithography for high-throughput microparticle synthesis
Dendukuri, D., Pregibon, D. C., Collins, J., Hatton, T. A., & Doyle, P. S. (2006) · Nature Materials · doi:10.1038/nmat1617 · Cited by 1,040
Deciding Whether To Go with the Flow: Evaluating the Merits of Flow Reactors for Synthesis
Hartman, R. L., McMullen, J. P., & Jensen, K. F. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201004637 · Cited by 999
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Self-citationScaling and the design of miniaturized chemical-analysis systems
Janasek, D., Franzke, J., & Manz, A. (2006) · Nature · doi:10.1038/nature05059 · Cited by 716
Novel Process Windows for Enabling, Accelerating, and Uplifting Flow Chemistry
Hessel, V., Kralisch, D., Kockmann, N., Noël, T., & Wang, Q. (2013) · ChemSusChem · doi:10.1002/cssc.201200766 · Cited by 596
Prakash, M., & Gershenfeld, N. (2007) · Science · doi:10.1126/science.1136907 · Cited by 511
Microchemical systems for continuous-flow synthesis
Hartman, R. L., & Jensen, K. F. (2009) · Lab on a Chip · doi:10.1039/b906343a · Cited by 508
Chemistry with [18F]Fluoride Ion
Cai, L., Lu, S., & Pike, V. W. (2008) · European Journal of Organic Chemistry · doi:10.1002/ejoc.200800114 · Cited by 469
Geyer, K., Codée, J. D. C., & Seeberger, P. H. (2006) · Chemistry – A European Journal · doi:10.1002/chem.200600596 · Cited by 462
Applying Flow Chemistry: Methods, Materials, and Multistep Synthesis
McQuade, D. T., & Seeberger, P. H. (2013) · The Journal of Organic Chemistry · doi:10.1021/jo400583m · Cited by 460
Flash chemistry: flow chemistry that cannot be done in batch
Yoshida, J.-I., Takahashi, Y., & Nagaki, A. (2013) · Chem. Commun. · doi:10.1039/c3cc44709j · Cited by 450
Applications of microfluidics in chemical biology
Weibel, D. B., & Whitesides, G. M. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.10.016 · Cited by 443
Novel Process Windows – Gate to Maximizing Process Intensification via Flow Chemistry
Hessel, V. (2009) · Chemical Engineering & Technology · doi:10.1002/ceat.200900474 · Cited by 415
Characterizing and Patterning of PDMS‐Based Conducting Composites
Niu, X. Z., Peng, S. L., Liu, L. Y., Wen, W. J., & Sheng, P. (2007) · Advanced Materials · doi:10.1002/adma.200602515 · Cited by 414
Microfluidics: Applications for analytical purposes in chemistry and biochemistry
Ohno, K., Tachikawa, K., & Manz, A. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800121 · Cited by 398
Multistep Continuous‐Flow Microchemical Synthesis Involving Multiple Reactions and Separations
Sahoo, H. R., Kralj, J. G., & Jensen, K. F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200701434 · Cited by 397
Molecular tracers for the PET and SPECT imaging of disease
Pimlott, S. L., & Sutherland, A. (2011) · Chem. Soc. Rev. · doi:10.1039/b922628c · Cited by 379
Recent advances in synthetic micro reaction technology
Watts, P., & Wiles, C. (2007) · Chem. Commun. · doi:10.1039/b609428g · Cited by 370
Integrated Microreactors for Reaction Automation: New Approaches to Reaction Development
McMullen, J. P., & Jensen, K. F. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073718 · Cited by 359
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Chiu, D. T., deMello, A. J., Di Carlo, D., Doyle, P. S., Hansen, C., Maceiczyk, R. M., & Wootton, R. C. R. (2017) · Chem · doi:10.1016/j.chempr.2017.01.009 · Cited by 347
Advanced organic synthesis using microreactor technology
Ahmed-Omer, B., Brandt, J. C., & Wirth, T. (2007) · Org. Biomol. Chem. · doi:10.1039/b615072a · Cited by 320
Continuous Flow Reactors, a Tool for the Modern Synthetic Chemist
Wiles, C., & Watts, P. (2008) · European Journal of Organic Chemistry · doi:10.1002/ejoc.200701041 · Cited by 310
Why microfluidics? Merits and trends in chemical synthesis
Liu, Y., & Jiang, X. (2017) · Lab on a Chip · doi:10.1039/c7lc00627f · Cited by 291
Flash chemistry: flow microreactor synthesis based on high‐resolution reaction time control
Yoshida, J. (2010) · The Chemical Record · doi:10.1002/tcr.201000020 · Cited by 277
Yuan, B., Jin, Y., Sun, Y., Wang, D., Sun, J., Wang, Z., Zhang, W., & Jiang, X. (2012) · Advanced Materials · doi:10.1002/adma.201104589 · Cited by 253
Multiphase Organic Synthesis in Microchannel Reactors
Kobayashi, J., Mori, Y., & Kobayashi, S. (2006) · Chemistry – An Asian Journal · doi:10.1002/asia.200600058 · Cited by 252
Metadata
- Authors
- Lee, C.-C., Sui, G., Elizarov, A., Shu, C. J., Shin, Y.-S., Dooley, A. N., Huang, J., Daridon, A., Wyatt, P., Stout, D., Kolb, H. C., Witte, O. N., Satyamurthy, N., Heath, J. R., Phelps, M. E., Quake, S. R., & Tseng, H.-R.
- Venue
- Science
- Published
- 2005-12-16
- Volume
- 310
- Issue
- 5755
- Pages
- 1793-1796
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2148626564
- Cited by
- 510
- References
- 13
- FWCI
- 25.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.