The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
Open accessAbstract
Recent advances in far-field fluorescence microscopy have led to substantial improvements in image resolution, achieving a near-molecular resolution of 20 to 30 nanometers in the two lateral dimensions. Three-dimensional (3D) nanoscale-resolution imaging, however, remains a challenge. We demonstrated 3D stochastic optical reconstruction microscopy (STORM) by using optical astigmatism to determine both axial and lateral positions of individual fluorophores with nanometer accuracy. Iterative, stochastic activation of photoswitchable probes enables high-precision 3D localization of each probe, and thus the construction of a 3D image, without scanning the sample. Using this approach, we achieved an image resolution of 20 to 30 nanometers in the lateral dimensions and 50 to 60 nanometers in the axial dimension. This development allowed us to resolve the 3D morphology of nanoscopic cellular structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Self-citationNonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
The Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Myosin V Walks Hand-Over-Hand: Single Fluorophore Imaging with 1.5-nm Localization
Yildiz, A., Forkey, J. N., McKinney, S. A., Ha, T., Goldman, Y. E., & Selvin, P. R. (2003) · Science · doi:10.1126/science.1084398 · Cited by 1,837
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
Self-citationWide-field subdiffraction imaging by accumulated binding of diffusing probes
Sharonov, A., & Hochstrasser, R. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609643104 · Cited by 1,151
Illuminating Single Molecules in Condensed Matter
Moerner, W. E., & Orrit, M. (1999) · Science · doi:10.1126/science.283.5408.1670 · Cited by 1,129
Hell, S. W. (2003) · Nature Biotechnology · doi:10.1038/nbt895 · Cited by 1,003
Hypertonic media inhibit receptor-mediated endocytosis by blocking clathrin-coated pit formation.
Heuser, J. E., & Anderson, R. G. (1989) · The Journal of cell biology · doi:10.1083/jcb.108.2.389 · Cited by 919
Tracking kinesin-driven movements with nanometre-scale precision
Gelles, J., Schnapp, B. J., & Sheetz, M. P. (1988) · Nature · doi:10.1038/331450a0 · Cited by 819
Accessory factors in clathrin-dependent synaptic vesicle endocytosis
Slepnev, V. I., & De Camilli, P. (2000) · Nature Reviews Neuroscience · doi:10.1038/35044540 · Cited by 517
Kao, H. P., & Verkman, A. S. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80601-0 · Cited by 420
I5M: 3D widefield light microscopy with better than 100 nm axial resolution
Gustafsson, Agard, & Sedat (1999) · Journal of Microscopy · doi:10.1046/j.1365-2818.1999.00576.x · Cited by 417
Westphal, V., Rizzoli, S. O., Lauterbach, M. A., Kamin, D., & Hell, S. W. (2009) · Advances in Imaging · doi:10.1364/ntm.2009.nma1 · Cited by 365
Short-Range Spectroscopic Ruler Based on a Single-Molecule Optical Switch
Bates, M., Blosser, T. R., & Zhuang, X. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.108101 · Cited by 364
Self-citationSite-specific labeling of proteins with small molecules in live cells
Chen, I., & Ting, A. Y. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.12.003 · Cited by 314
Fluorescence Nanoscopy in Whole Cells by Asynchronous Localization of Photoswitching Emitters
Egner, A., Geisler, C., von Middendorff, C., Bock, H., Wenzel, D., Medda, R., Andresen, M., Stiel, A. C., Jakobs, S., Eggeling, C., et al. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.112201 · Cited by 284
Nanometric three-dimensional tracking of individual quantum dots in cells
Holtzer, L., Meckel, T., & Schmidt, T. (2007) · Applied Physics Letters · doi:10.1063/1.2437066 · Cited by 253
Three-Dimensional Particle Tracking via Bifocal Imaging
Toprak, E., Balci, H., Blehm, B. H., & Selvin, P. R. (2007) · Nano Letters · doi:10.1021/nl0709120 · Cited by 219
3-Dimensional super-resolution by spectrally selective imaging
van Oijen, A. M., Köhler, J., Schmidt, J., Müller, M., & Brakenhoff, G. J. (1998) · Chemical Physics Letters · doi:10.1016/s0009-2614(98)00673-3 · Cited by 200
Two-color far-field fluorescence nanoscopy based on photoswitchable emitters
Bock, H., Geisler, C., Wurm, C. A., von Middendorff, C., Jakobs, S., Schönle, A., Egner, A., Hell, S. W., & Eggeling, C. (2007) · Applied Physics B · doi:10.1007/s00340-007-2729-0 · Cited by 159
Ecological and genetic spatial structuring in the Canadian lynx
Rueness, E. K., Stenseth, N. C., O’Donoghue, M., Boutin, S. A., Ellegren, H., & Jakobsen, K. S. (2003) · Nature · doi:10.1038/nature01942 · Cited by 143
Fluorescence microscopy with super-resolved optical sections
Egner, A., & Hell, S. W. (2005) · Trends in Cell Biology · doi:10.1016/j.tcb.2005.02.003 · Cited by 135
Barak, L. S., & Webb, W. W. (1981) · The Journal of Cell Biology · doi:10.1083/jcb.90.3.595 · Cited by 129
Nagorni, M., & Hell, S. W. (1998) · Journal of Structural Biology · doi:10.1006/jsbi.1998.4037 · Cited by 76
Rigorous theory for axial resolution in confocal microscopes
Török, P., & Wilson, T. (1997) · Optics Communications · doi:10.1016/s0030-4018(96)00771-7 · Cited by 53
Cited by
Dynamic Imaging of Genomic Loci in Living Human Cells by an Optimized CRISPR/Cas System
Chen, B., Gilbert, L. A., Cimini, B. A., Schnitzbauer, J., Zhang, W., Li, G.-W., Park, J., Blackburn, E. H., Weissman, J. S., Qi, L. S., et al. (2013) · Cell · doi:10.1016/j.cell.2013.12.001 · Cited by 1,963
Self-citationAdvanced methods of microscope control using μManager software
D. Edelstein, A., A. Tsuchida, M., Amodaj, N., Pinkard, H., D. Vale, R., & Stuurman, N. (2014) · Journal of Biological Methods · doi:10.14440/jbm.2014.36 · Cited by 1,909
Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Self-citationOvesný, M., Křížek, P., Borkovec, J., Švindrych, Z., & Hagen, G. M. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu202 · Cited by 1,506
Metadata
- Authors
- Huang, B., Wang, W., Bates, M., & Zhuang, X.
- Venue
- Science
- Published
- 2008-02-08
- Volume
- 319
- Issue
- 5864
- Pages
- 810-813
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2066521860
- Cited by
- 2,796
- References
- 31
- FWCI
- 63.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.