A brain-computer interface that evokes tactile sensations improves robotic arm control

Open access

Published version of a preprint

The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index; 5 of the 15 sources its claims cite were checked for support.

Abstract

Prosthetic arms controlled by a brain-computer interface can enable people with tetraplegia to perform functional movements. However, vision provides limited feedback because information about grasping objects is best relayed through tactile feedback. We supplemented vision with tactile percepts evoked using a bidirectional brain-computer interface that records neural activity from the motor cortex and generates tactile sensations through intracortical microstimulation of the somatosensory cortex. This enabled a person with tetraplegia to substantially improve performance with a robotic limb; trial times on a clinical upper-limb assessment were reduced by half, from a median time of 20.9 to 10.2 seconds. Faster times were primarily due to less time spent attempting to grasp objects, revealing that mimicking known biological control principles results in task performance that is closer to able-bodied human abilities.

Overview

CoChat Summary

TL;DR

A bidirectional brain-computer interface that decoded motor intent and delivered intracortical microstimulation to somatosensory cortex improved a person with tetraplegia’s control of a robotic arm. Adding tactile feedback reduced median ARAT trial time from 20.9 to 10.2 s and improved median ARAT score from 17 to 21.

Key findings

  • With ICMS-evoked tactile feedback, median ARAT score was 21 versus 17 without ICMS (p = 0.029, Wilcoxon rank-sum test), and higher than 23 prior sessions without ICMS (p = 0.005).
  • Successful ARAT trial times decreased by 51.2%, from a median of 20.9 s to 10.2 s (p < 0.0001); grasp time decreased by 66%, from 13.3 s to 4.6 s, accounting for 88% of the total improvement.
  • A score of 3, indicating object transfer in under 5 s, was achieved 15 times with tactile feedback versus once across all 108 trials without it; 14% of trials with tactile feedback were faster than the fastest trial without ICMS.
  • In the object transfer task, time in the object zone decreased by 30.3%, from 3.3 ± 1.2 s to 2.3 ± 0.4 s per transfer (p = 0.002), and hand movement in the object zone decreased from 44.2 ± 13.1 to 32.4 ± 5.9 cm per transfer (p = 0.0007); total transfers increased from 315 without ICMS to 352 with ICMS, but transfers per trial did not significantly differ (15.8 ± 3.8 to 17.8 ± 2.4, p = 0.050).

Methods

  • Single participant: a 28-year-old male with tetraplegia due to C5 motor/C6 sensory ASIA B spinal cord injury sustained 10 years before consent; study conducted under FDA Investigational Device Exemption and registered at ClinicalTrials.gov (NCT01894802).
  • Two 88-electrode arrays were implanted in motor cortex hand/arm region to decode movement intent, and two 32-electrode arrays were implanted in area 1 of somatosensory cortex; a new 5 degree-of-freedom velocity decoder was trained daily, and ICMS was driven in real time by robotic hand sensors responding to object contact and grasp force.
  • Performance was compared with and without ICMS on a modified ARAT with nine tasks, each object attempted three times per session and scored 0–3 with maximum score 27, using four sessions with ICMS and four without plus 23 prior sessions; an object transfer task was also performed in four sessions with and four without ICMS, five times per session, with Wilcoxon rank-sum and t-tests used for comparisons.

Limitations

  • The paper states that this is a single-subject study and it is not guaranteed that findings will generalize to future experiments and participants.
  • The paper states that future work should examine how stimulation encoding design, such as proportional versus on-off feedback, affects performance, and notes that many objects were rigid with no penalty for grasping too firmly, so fragile objects or more precise hand posture/grasp force control could depend more on specific sensory encoding schemes.
  • Evident from the text: the participant had only one grasp dimension that opened and closed all fingers as a group, and some smaller objects were difficult to pick up because the fingertips often contacted objects rather than the distal phalanx pads, making grasp less stable; the increase in transfers per trial with ICMS was not statistically significant (p = 0.050).

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1126/science.abd0380

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

3 Valid · 0 Not valid · 7 Not checked · 32 Own results and interpretations

19 more claims

Create a free account to see all 42 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 15
  • Probably not a substantial claim. 3

Create a free account to see these claims.

Citations

Cites

Show all 51 references

Research works printed but not linked: 2

  1. J. M. Loomis R. L. Klatzky N. A. Giudice in Assistive Technology for Blindness and Low Vision R. Manduchi S. Kurniawan Eds. (CRC Press 2012).
  2. M. S. Johannes, J. D. Bigelow, J. M. Burck, S. D. Harshbarger, M. V. Kozlowski, T. Van Doren, An overview of the developmental process for the modular prosthetic limb. Johns Hopkins APL Tech. Dig. 30, 207–216 (2011).

Cited by

Items 201–300 of 615

Metadata

Authors
Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A.
Affiliations
  • University of Pittsburgh (US)
  • Department of Neurosurgery, University of Texas at Austin, Austin, TX, USA.
  • United States Department of Veterans Affairs (US)
Corresponding author
Flesher, Sharlene N.
Venue
Science
Published
2021-05-21
Volume
372
Issue
6544
Pages
831-836
ISSN
  • 0036-8075 (ISSN-L)
  • 1095-9203
OpenAlex
W3161143221
Cited by
617
References
40
Citations by year
2026: 102 · 2025: 154 · 2024: 131 · 2023: 102 · 2022: 75 · 2021: 41
FWCI
45.79
Type
journal article
Language
en
Open access
Locations
  • Science (publishedVersion)
  • bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • Defense Advanced Research Projects Agency (N66001-16-C-4051, N66001-10-C-4056)
  • National Science Foundation (DGE-1247842)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
Keywords
brain-computer interface, tactile feedback, robotic arm control, tetraplegia, intracortical microstimulation, somatosensory cortex, motor cortex, upper limb prosthesis, grasping, bidirectional neural interface
MeSH terms
Adult, Arm, Artificial Limbs, Humans, Male, Motor Cortex, Movement, Quadriplegia, Robotics, Somatosensory Cortex, Touch, Hand Strength, Brain-Computer Interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.