Abstract
Prosthetic arms controlled by a brain-computer interface can enable people with tetraplegia to perform functional movements. However, vision provides limited feedback because information about grasping objects is best relayed through tactile feedback. We supplemented vision with tactile percepts evoked using a bidirectional brain-computer interface that records neural activity from the motor cortex and generates tactile sensations through intracortical microstimulation of the somatosensory cortex. This enabled a person with tetraplegia to substantially improve performance with a robotic limb; trial times on a clinical upper-limb assessment were reduced by half, from a median time of 20.9 to 10.2 seconds. Faster times were primarily due to less time spent attempting to grasp objects, revealing that mimicking known biological control principles results in task performance that is closer to able-bodied human abilities.
Overview
CoChat Summary
TL;DR
A bidirectional brain-computer interface that decoded motor intent and delivered intracortical microstimulation to somatosensory cortex improved a person with tetraplegia’s control of a robotic arm. Adding tactile feedback reduced median ARAT trial time from 20.9 to 10.2 s and improved median ARAT score from 17 to 21.
Key findings
- With ICMS-evoked tactile feedback, median ARAT score was 21 versus 17 without ICMS (p = 0.029, Wilcoxon rank-sum test), and higher than 23 prior sessions without ICMS (p = 0.005).
- Successful ARAT trial times decreased by 51.2%, from a median of 20.9 s to 10.2 s (p < 0.0001); grasp time decreased by 66%, from 13.3 s to 4.6 s, accounting for 88% of the total improvement.
- A score of 3, indicating object transfer in under 5 s, was achieved 15 times with tactile feedback versus once across all 108 trials without it; 14% of trials with tactile feedback were faster than the fastest trial without ICMS.
- In the object transfer task, time in the object zone decreased by 30.3%, from 3.3 ± 1.2 s to 2.3 ± 0.4 s per transfer (p = 0.002), and hand movement in the object zone decreased from 44.2 ± 13.1 to 32.4 ± 5.9 cm per transfer (p = 0.0007); total transfers increased from 315 without ICMS to 352 with ICMS, but transfers per trial did not significantly differ (15.8 ± 3.8 to 17.8 ± 2.4, p = 0.050).
Methods
- Single participant: a 28-year-old male with tetraplegia due to C5 motor/C6 sensory ASIA B spinal cord injury sustained 10 years before consent; study conducted under FDA Investigational Device Exemption and registered at ClinicalTrials.gov (NCT01894802).
- Two 88-electrode arrays were implanted in motor cortex hand/arm region to decode movement intent, and two 32-electrode arrays were implanted in area 1 of somatosensory cortex; a new 5 degree-of-freedom velocity decoder was trained daily, and ICMS was driven in real time by robotic hand sensors responding to object contact and grasp force.
- Performance was compared with and without ICMS on a modified ARAT with nine tasks, each object attempted three times per session and scored 0–3 with maximum score 27, using four sessions with ICMS and four without plus 23 prior sessions; an object transfer task was also performed in four sessions with and four without ICMS, five times per session, with Wilcoxon rank-sum and t-tests used for comparisons.
Limitations
- The paper states that this is a single-subject study and it is not guaranteed that findings will generalize to future experiments and participants.
- The paper states that future work should examine how stimulation encoding design, such as proportional versus on-off feedback, affects performance, and notes that many objects were rigid with no penalty for grasping too firmly, so fragile objects or more precise hand posture/grasp force control could depend more on specific sensory encoding schemes.
- Evident from the text: the participant had only one grasp dimension that opened and closed all fingers as a group, and some smaller objects were difficult to pick up because the fingertips often contacted objects rather than the distal phalanx pads, making grasp less stable; the increase in transfers per trial with ICMS was not statistically significant (p = 0.050).
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
3 Valid · 0 Not valid · 7 Not checked · 32 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“First, using the same fundamental neural decoding and control methods, two participants have achieved similar scores on functional tasks with vision alone (5, 6, 28).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Partly supportedcites [5] Wodlinger B, J. Neural Eng 12, 016011 (2015). 25514320 sourceExperimental — accuracy not yet measured
Section 3.4 reports similar functional-task scores under 7D and 10D control, but both scores are from the same participant. Section 2.2 identifies a single participant; this paper therefore does not establish the claim about two participants achieving similar scores with vision alone. Page numbers are unavailable in our copy. (LLM, conf=0.88)
- Partly supportedcites [6] Collinger JL, Lancet (London, England) 381, 557– 64 (2013). PMC3641862 23253623 sourceExperimental — accuracy not yet measured
The Methods (Observation-based calibration and neural decoding; Functional brain-control tasks) describe neural decoding and functional testing, and the Results (Clinical assessments) report an ARAT score of 15–17 for one participant. This paper does not establish that two participants achieved similar scores, and the retrieved passages do not explicitly say the tasks were performed with vision alone. (LLM, conf=0.84)
- Partly supportedcites [28] Downey JE, Sci. Rep 7, 16947 (2017). 29209023 PMC5717217 sourceExperimental — accuracy not yet measured
The Methods (Study participants; Neural recording and BCI decoder calibration, page unavailable) describe two participants using motor-cortex decoding to control a robotic arm; somatosensory arrays were not used in this experiment. The Results (Online population-level scaling improves BCI object grasping, page unavailable) report fairly close object-interaction success rates with scaling, but the more functional object-transport scores differ substantially: 1.09 versus 5.28 transfers per minute. Thus, the paper does not support a general claim that the participants achieved similar scores on functional tasks. (LLM, conf=0.86)
plainn = 2- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“In contrast, ICMS feedback in a relevant area of cortex, but in an unintuitive way, requires considerable learning time (thousands of trials) to use effectively (33).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Supportedcites [33] Dadarlat MC, O’Doherty JE, Sabes PN, Nat. Neurosci 18, 138– 44 (2015). 25420067 PMC4282864 source
The Results (Behavioral task and feedback signals) describe ICMS in somatosensory cortex, with electrode directions assigned independently of local neuronal responses. The Discussion (Learning to integrate a novel sensory signal) says the patterns did not mimic naturally occurring signals and had to be learned. Online Methods (Experimental Design) reports approximately 20,000 and 40,000 training trials before the two monkeys showed clear evidence of integrating ICMS with vision. (LLM, conf=0.94)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“it is only in recent studies of humans with chronically implanted microelectrode arrays that the perceptual characteristics of microstimulation have been elucidated (19, 20).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Not checked — no full text of the sourcecites [19] Flesher SN, Sci. Transl. Med 8, 361ra141 (2016). 27738096 source
- Supportedcites [20] Salas MA, Elife 7 (2018), doi: 10.7554/eLife.32904. source
The Abstract describes recent human ICMS studies and reports sensations elicited in a person with two implanted microelectrode arrays. Materials and methods (Task) describes how the participant reported each percept’s location, intensity, duration, and qualitative character; Results and discussion reports the resulting percept measurements. These passages support the claim that such human studies elucidated the perceptual characteristics of microstimulation. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Further, 14% of the trials with tactile feedback were completed more quickly than the very fastest trial without ICMS (Fig. 2C).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The time spent in the object zone (Fig. 1G) decreased by 30.3%, from 3.3 ± 1.2 s per transfer without ICMS to 2.3 ± 0.4 s per transfer with ICMS (p = 0.002, t-test, Fig. 3A).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
plainstates a causeSingle case ·- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
19 more claims
Create a free account to see all 42 claims and every source verdict.
- It may state two separate claims as one. 15
- Probably not a substantial claim. 3
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Generalized Inverses, Ridge Regression, Biased Linear Estimation, and Nonlinear Estimation
Marquardt, D. W. (1970) · Technometrics · doi:10.1080/00401706.1970.10488699 · Cited by 2,276
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Self-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Lyle, R. C. (1981) · International Journal of Rehabilitation Research · doi:10.1097/00004356-198112000-00001 · Cited by 1,326
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Research works printed but not linked: 2
- J. M. Loomis R. L. Klatzky N. A. Giudice in Assistive Technology for Blindness and Low Vision R. Manduchi S. Kurniawan Eds. (CRC Press 2012).
- M. S. Johannes, J. D. Bigelow, J. M. Burck, S. D. Harshbarger, M. V. Kozlowski, T. Van Doren, An overview of the developmental process for the modular prosthetic limb. Johns Hopkins APL Tech. Dig. 30, 207–216 (2011).
Cited by
Items 101–200 of 615
An Ultraflexible Electrode Array for Large‐Scale Chronic Recording in the Nonhuman Primate Brain
Tian, Y., Yin, J., Wang, C., He, Z., Xie, J., Feng, X., Zhou, Y., Ma, T., Xie, Y., Li, X., et al. (2023) · Advanced Science · doi:10.1002/advs.202302333 · Cited by 33
Emerging Frontiers in Human–Robot Interaction
Safavi, F., Olikkal, P., Pei, D., Kamal, S., Meyerson, H., Penumalee, V., & Vinjamuri, R. K. (2024) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-024-02074-7 · Cited by 38
“…arms by enabling top-down neural control of prosthetic arms and stimulating the somatosensory cortex to generate natural tactile sensations [80, 81] Currently, a lot of research is focused on the development of BCI-controlled, especially teleoperated, mobile robots for commercial use [83, 84].”
Reward signals in the motor cortex: from biology to neurotechnology
Derosière, G., Shokur, S., & Vassiliadis, P. (2025) · Nature Communications · doi:10.1038/s41467-024-55016-0 · Cited by 33
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 44
“…Lehongre et al. 2022); Intracortical electrode array: (Ajiboye et al. 2017; Barry et al. 2023; Collinger et al. 2013; Deo et al. 2024; Drew 2024; Flesher et al. 2021; Hosman et al. 2023; Rastogi et al. 2021; Willett et al. 2023, 2021); Endovascular electrode array: (Mitchell et al. 2023; Oxley…”
Gao, W., Yan, Z., Zhou, H., Xie, Y., Wang, H., Yang, J., Yu, J., Ni, C., Liu, P., Xie, M., et al. (2025) · Journal of Nanobiotechnology · doi:10.1186/s12951-025-03573-x · Cited by 51
Stieger, K. C., Eles, J. R., Ludwig, K. A., & Kozai, T. D. Y. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5bf5 · Cited by 31
“Intracortical microstimulation (ICMS) is a powerful tool to provide sensory feedback and restoration during control of neural prosthetics(1-6).”
Hughes, C. L., & Kozai, T. D. Y. (2023) · Brain stimulation · doi:10.1016/j.brs.2023.05.013 · Cited by 31
“For somatosensory ICMS, stimulus intensity has been linearly scaled to force detected on prosthetic hands by increasing ICMS amplitude, which improves robotic arm control [41] while visual ICMS has previously only provided short stimulus trains to represent simple features such as location, luminance, and shape [18],…”
BackgroundMethodInfluentialSelf-citationXia, M., Agca, B. N., Yoshida, T., Choi, J., Amjad, U., Bose, K., Keren, N., Zukerman, S., Cima, M. J., Graybiel, A. M., et al. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115625 · Cited by 32
Canny, E., Vansteensel, M. J., van der Salm, S. M. A., Müller-Putz, G., & Berezutskaya, J. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01272-y · Cited by 42
“…body language and facial expressions to communicate emotion and social signals, (4) an increased sense of agency and control, (5) somatosensory feedback by design—an important component that has been shown to have positive effects on accuracy and speed of produced movements in BCI users [91].”
BackgroundRestoring Speech Using Brain–Computer Interfaces
Stavisky, S. D. (2025) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110122-012818 · Cited by 51
Sensory Feedback for Upper-Limb Prostheses: Opportunities and Barriers
Jabban, L., Dupan, S. S. G., Zhang, D., Ainsworth, B., Nazarpour, K., & Metcalfe, B. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3159186 · Cited by 36
“Both DRG interfaces and CI are still in their early development phase, with a limited number of clinical trials, and will not be covered in this review [29].”
BackgroundChristie, B. P., Osborn, L. E., McMullen, D. P., Pawar, A. S., Thomas, T. M., Bensmaïa, S. J., Celnik, P. A., Fifer, M. S., & Tenore, F. V. (2022) · Brain stimulation · doi:10.1016/j.brs.2022.05.015 · Cited by 32
Chandrasekaran, S., Bickel, S., Herrero, J. L., Kim, J.-W., Markowitz, N., Espinal, E., Bhagat, N. A., Ramdeo, R., Xu, J., Glasser, M. F., et al. (2021) · Brain stimulation · doi:10.1016/j.brs.2021.07.009 · Cited by 29
“Although such artificial sensory feedback helps improve the user performance with a BCI system [16], focal percepts in fingertips that would be critical for dexterous manipulations as those mentioned above [17] have been difficult to achieve.”
BackgroundOsborn, L. E., Christie, B. P., McMullen, D. P., Nickl, R. W., Thompson, M. C., Pawar, A. S., Thomas, T. M., Anaya, M. A., Crone, N. E., Wester, B. A., et al. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630450 · Cited by 32
“Delivery of ICMS during motor control behaviors has been shown to improve task performance [7].”
BackgroundMethodLi, G., Jiang, S., Meng, J., Chai, G., Wu, Z., Fan, Z., Hu, J. Z., Sheng, X., Zhang, D., Chen, L., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.118969 · Cited by 23
“, 2019), and robot arm manipulation (Flesher et al., 2021; Edelman et al., 2019; Cao et al., 2021).”
Hayashi, H., & Tsuji, T. (2022) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23646 · Cited by 27
An implantable, wireless, battery-free system for tactile pressure sensing
Du, L., Hao, H., Ding, Y., Gabros, A. D., Mier, T. C. E., der Spiegel, J. V., Lucas, T. H., Aflatouni, F., Richardson, A. G., & Allen, M. G. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00602-3 · Cited by 27
“A few well-placed sensors can dramatically improve grasping behaviors 38 .”
BackgroundMethodWang, X., Wu, S. P., Yang, H., Bao, Y., Li, Z., Gan, C., Deng, Y., Cao, J., Li, X., Wang, Y., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-53720-5 · Cited by 31
Sombeck, J. T., & Miller, L. E. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5cf3 · Cited by 25
Downey, J. E., Schone, H. R., Foldes, S. T., Greenspon, C. M., Liu, F., Verbaarschot, C., Biro, D., Satzer, D. I., Moon, C., Coffman, B. A., et al. (2024) · Human Brain Mapping · doi:10.1002/hbm.70118 · Cited by 27
Self-citationIn vivo microelectrode arrays for neuroscience
Williams, N. P., Vöröslakos, M., Shi, D., Pwint, M. Y., Lanzio, V., Mao, H., Zolotavin, P., Yoon, E., Stieglitz, T., Xie, C., et al. (2025) · Nature Reviews Methods Primers · doi:10.1038/s43586-025-00399-7 · Cited by 39
“Tactile sensations can be artificially elicited through intracortical microstimulation in the somatosensory cortex 14,175 .”
A Psychometric Platform to Collect Somatosensory Sensations for Neuroprosthetic Use
Valle, G., Iberite, F., Strauss, I., D’Anna, E., Granata, G., Iorio, R. D., Stieglitz, T., Raspopović, S., Petrini, F. M., Rossini, P. M., et al. (2021) · Frontiers in Medical Technology · doi:10.3389/fmedt.2021.619280 · Cited by 24
Algorithm and hardware considerations for real-time neural signal on-implant processing
Zhang, Z., Savolainen, O. W., & Constandinou, T. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5268 · Cited by 25
Recent advances in wireless epicortical and intracortical neuronal recording systems
Ji, B., Liang, Z., Yuan, X., Xu, H., Wang, M., Yin, E., Guo, Z., Wang, L., Zhou, Y., Feng, H., et al. (2022) · Science China Information Sciences · doi:10.1007/s11432-021-3373-1 · Cited by 32
How Far for the Electronic Skin: From Multifunctional Material to Advanced Applications
Chen, Y., Sun, Y., Wei, Y., & Qiu, J. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201352 · Cited by 26
Multimodal Technologies for Closed‐Loop Neural Modulation and Sensing
Li, L., Zhang, B., Zhao, W., Sheng, D., Yin, L., Sheng, X., & Yao, D. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303289 · Cited by 32
Ienca, M., Valle, G., & Raspopović, S. (2025) · The Lancet Digital Health · doi:10.1016/s2589-7500(24)00222-x · Cited by 33
Plasticity in Cervical Motor Circuits following Spinal Cord Injury and Rehabilitation
Walker, J., & Detloff, M. R. (2021) · Biology · doi:10.3390/biology10100976 · Cited by 36
“Therapeutic interventions for individuals with complete SCI are limited to regenerative medicine or the utilization of compensatory devices [20,21].”
BackgroundDisrupted autonomic pathways in spinal cord injury: Implications for the immune regulation
Moura, M. M., Monteiro, A., Salgado, A. J., Silva, N. A., & Monteiro, S. (2024) · Neurobiology of Disease · doi:10.1016/j.nbd.2024.106500 · Cited by 30
“Although few axons spontaneously regenerate over long distances, studies have shown that following SCI limited spontaneous sprouting that can lead to motor and sensory improvements (Flesher et al., 2021; Xiao et al., 2018).”
A lightweight and accurate double-branch neural network for four-class motor imagery classification
Ma, W., Gong, Y., Xue, H., Liu, Y., Lin, X., Zhou, G., & Li, Y. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103582 · Cited by 21
Neurocognitive and motor-control challenges for the realization of bionic augmentation
Makin, T. R., Micera, S., & Miller, L. E. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00930-1 · Cited by 26
Bibliometric analysis on Brain-computer interfaces in a 30-year period
Yin, Z., Wan, Y., Fang, H., Li, L., Wang, T., Wang, Z., & Tan, D. (2022) · Applied Intelligence · doi:10.1007/s10489-022-04226-4 · Cited by 26
“As BCI technology advances and the risks of invasive brain recordings reduce, the bidirectional BCI system has emerged, possibly restoring locomotion and speech by inducing activity-dependent brain plasticity [13].”
BackgroundLoutit, A. J., & Potas, J. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00156 · Cited by 24
Bionic Recognition Technologies Inspired by Biological Mechanosensory Systems
Zhang, X., Wang, C., Pi, X., Li, B., Ding, Y., Yu, H., Sun, J., Wang, P., Chen, Y., Wang, Q., et al. (2025) · Advanced Materials · doi:10.1002/adma.202418108 · Cited by 35
Hobbs, T. G., Greenspon, C. M., Verbaarschot, C., Valle, G., Hughes, C. L., Boninger, M. L., Bensmaïa, S. J., & Gaunt, R. A. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adc2d4 · Cited by 27
“This is a plausible encoding method as perceived intensity scales with both ICMS current amplitude and indentation depth [9, 13].”
Self-citationDeo, D. R., Rezaii, P. G., Hochberg, L. R., Okamura, A. M., Shenoy, K. V., & Henderson, J. M. (2021) · IEEE Transactions on Haptics · doi:10.1109/toh.2021.3072615 · Cited by 26
Highly sensitive soft optical fiber tactile sensor
Xu, T., Li, L., Wang, Y., Ma, Q., Jia, C., & Shao, C. (2022) · Optics Express · doi:10.1364/oe.467865 · Cited by 23
Kancheva, I. K., der Salm, S. M. A. V., Ramsey, N. F., & Vansteensel, M. J. (2023) · Neurological Sciences · doi:10.1007/s10072-023-06982-8 · Cited by 24
“In addition, BCIs may provide users with sensory feedback about their movement attempts, through brain-signal-driven functional electrical stimulation of the muscles [13] or micro-stimulation of the somatosensory cortex surface [9].”
BackgroundElectrode sharpness and insertion speed reduce tissue damage near high-density penetrating arrays
McNamara, I., Wellman, S. M., Li, L., Eles, J. R., Savya, S. P., Sohal, H. S., Angle, M. R., & Kozai, T. D. Y. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad36e1 · Cited by 25
Planar Amorphous Silicon Carbide Microelectrode Arrays for Chronic Recording in Rat Motor Cortex
Abbott, J., Jeakle, E. N., Haghighi, P., Usoro, J. O., Sturgill, B. S., Wu, Y., Geramifard, N., Radhakrishna, R., Patnaik, S. S., Nakajima, S., et al. (2023) · Biomaterials · doi:10.1016/j.biomaterials.2024.122543 · Cited by 25
Guémann, M., Halgand, C., Bastier, A., Lansade, C., Borrini, L., Lapeyre, E., Cattaert, D., & de Rugy, A. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01038-y · Cited by 30
“Invasive techniques include BCI using cortical electrodes that bypass the use of peripheral neural and musculoskeletal systems [6], and intraneural electrodes directly connected to a sensory nerve that could be stimulated to produce either tactile or proprioceptive sensation [8–11].”
BackgroundMethodZhai, Y., Duan, G., Hu, J., Lv, Z., Ding, G., Zhou, Y., & Han, S. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202406239 · Cited by 20
Patterned electrical brain stimulation by a wireless network of implantable microdevices
Lee, A., Lee, J.-H., Leung, V., Larson, L. E., & Nurmikko, A. V. (2024) · Nature Communications · doi:10.1038/s41467-024-54542-1 · Cited by 31
“In the case of focused electrical stimulation, there is considerable evidence thatcurrent pulses injected locally, e.g.,into the hand area of thesomatosensorycortex,canelicittactilesensationinnon-human 13 – 16 and human primates 17 – 19 .”
Mensah, E. O., Chalif, J. I., Johnston, B. R., Chalif, E. J., Parker, T., Izzy, S., He, Z., Saigal, R., Fehlings, M. G., & Lu, Y. (2025) · North American Spine Society Journal (NASSJ) · doi:10.1016/j.xnsj.2025.100601 · Cited by 45
“Additionally, the potential for BCI-enabled prostheses such as neurally-controlled robotic arms to restore grasp and reach functions in tetraplegic patients has proven to be effec-tive and continues to be a field of exciting research and development [ 268 , 269 ].”
Amoruso, E., Dowdall, L., Kollamkulam, M., Ukaegbu, O. C., Kieliba, P., Ng, T., Dempsey‐Jones, H., Clode, D., & Makin, T. R. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac47d9 · Cited by 26
“…e.g. the peripheral nerves (Dhillon and Horch 2005, Raspopovic et al 2014, Tan et al 2014), the spinal cord (Chandrasekaran et al 2020), or the somatosensory cortex (Romo et al 1998, Tabot et al 2013, Flesher et al 2016, Salas et al 2018, Flesher et al 2021; see Bensmaia et al 2020, for a review).”
BackgroundClinical neuroscience and neurotechnology: An amazing symbiosis
Cometa, A., Falasconi, A., Biasizzo, M., Carpaneto, J., Horn, A., Mazzoni, A., & Micera, S. (2022) · iScience · doi:10.1016/j.isci.2022.105124 · Cited by 24
“machine-brain interfaces, in which the prostheses have a bidirectional connection with the cortex, for reading motor intentions and eliciting controlled sensations (Bensmaia et al., 2020; Flesher et al., 2021; Pandarinath and Bensmaia, 2022; Shokur et al., 2021).”
BackgroundMethodInfluentialElectromagnetic Brain–Computer–Metasurface Holography
Xiao, Q., Gao, W., Ma, Q., Gu, Z., Zhou, Y., Liu, C., Huang, Z. A., Wan, X., Li, L., Li, Y., et al. (2023) · ACS Photonics · doi:10.1021/acsphotonics.2c01349 · Cited by 24
Highly Stretchable, Self-Adhesive, Antidrying Ionic Conductive Organohydrogels for Strain Sensors
Huang, X., Wang, C., Yang, L., & Ao, X. (2023) · Molecules · doi:10.3390/molecules28062817 · Cited by 22
“In recent years, the application of flexible, wearable, and stretchable electronic devices has received a lot of attention, and they have a wide range of applications in electronic equipment fields, such as human life monitoring signals [1,2], flexible sensors [3,4], electronic skin [5], human robotics [6], and so for…”
BackgroundMcMullen, D. P., Thomas, T. M., Fifer, M. S., Candrea, D. N., Tenore, F. V., Nickl, R. W., Pohlmeyer, E. A., Coogan, C. G., Osborn, L. E., Schiavi, A. J., et al. (2021) · Journal of neurosurgery · doi:10.3171/2020.9.jns202675 · Cited by 21
Tessellation of artificial touch via microstimulation of human somatosensory cortexPreprint
Greenspon, C. M., Shelchkova, N. D., Valle, G., Hobbs, T. G., Berger-Wolf, E. I., Hutchison, B. C., Dogruoz, E., Verbaarschot, C., Callier, T., Sobinov, A. R., et al. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.06.23.545425 · Cited by 24
“…more localizable sensations than does single-electrode ICMS As discussed above, the circumscription and systematic localization of PFs can be exploited to convey information about (bionic) hand locations at which contact with an object is established (Flesher et al., 2021; Valle et al., 2018).”
Self-citationA 2.46-mm2 Miniaturized Brain-Machine Interface (MiBMI) Enabling 31-Class Brain-to-Text Decoding
Shaeri, M., Shin, U., Yadav, A., Caramellino, R., Rainer, G., & Shoaran, M. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3443254 · Cited by 25
“The MUA can be derived using a simple threshold crossing method [6], [8], capturing a mixture of multiple neuronal spikes recorded from an ensemble of neurons.”
BackgroundMethodHan, L., Liu, Y., Qi, Z., Zhao, Y., Zhang, N., Dong, Y., & Wang, X. (2025) · Nano Energy · doi:10.1016/j.nanoen.2025.110775 · Cited by 20
Shaeri, M., & Sodagar, A. M. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3151340 · Cited by 23
“This type of setup is usually used for experimental neuroscience studies and brain mapping [3]–[6], [10]–[12], [49]–[51].”
BackgroundMethodThe risks and challenges of neurotechnologies for human rights
M, S. N., & C, G. (2023) · UNESCO eBooks · doi:10.54678/pogs7778 · Cited by 42
An accurate and rapidly calibrating speech neuroprosthesis
Card, N. S., Wairagkar, M., Iacobacci, C., Hou, X., Singer-Clark, T., Willett, F. R., Kunz, E. M., Fan, C., Vahdati Nia, M., Deo, D. R., et al. (2023) · doi:10.1101/2023.12.26.23300110 · Cited by 244
Hughes, C. L., Stieger, K. C., Chen, K., Vazquez, A. L., & Kozai, T. D. Y. (2025) · iScience · doi:10.1016/j.isci.2025.112707 · Cited by 24
Self-citationShort report: surgery for implantable brain-computer interface assisted by robotic navigation system
Jiang, H., Wang, R., Zheng, Z., Zhu, J., Qi, Y., Xu, K., & Zhang, J. (2022) · Acta Neurochirurgica · doi:10.1007/s00701-022-05235-5 · Cited by 18
Ma, W., Wang, C., Sun, X., Lin, X., & Wang, Y. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104684 · Cited by 23
MBGA-Net: A multi-branch graph adaptive network for individualized motor imagery EEG classification
Ma, W., Wang, C., Sun, X., Lin, X., Niu, L., & Wang, Y. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107641 · Cited by 23
Anisotropic Electronic Skin for Neurofeedback
Hu, W., Song, D., Shi, X., Zhou, L., Zhao, Z., Xue, T., Lin, X., & Liu, N. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202309359 · Cited by 18
Challenges and Opportunities of Edge AI for Next-Generation Implantable BMIs
Shaeri, M., Afzal, A., & Shoaran, M. (2022) · IEEE International Conference on Artificial Intelligence Circuits and Systems (AICAS) · doi:10.1109/aicas54282.2022.9870008 · Cited by 19
“somatosensory cortex in order to restore sensory feedback [1].”
Effects of central nervous system electrical stimulation on non-neuronal cells
Williams, N. P., Kushwah, N. S., Dhawan, V., Zheng, X. S., & Cui, X. T. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.967491 · Cited by 20
Artificial Intelligence in Science and Society: The Vision of USERN
Dorigo, T., Brown, G. D., Casonato, C., Cerdà, A., Ciarrochi, J., Lio, M. D., D’Souza, N., Gauger, N. R., Hayes, S. C., Hofmann, S. G., et al. (2025) · IEEE Access · doi:10.1109/access.2025.3529357 · Cited by 27
Proprioceptive representations of the hand in somatosensory cortex
Lutz, O., & Bensmaïa, S. J. (2021) · Current Opinion in Physiology · doi:10.1016/j.cophys.2021.04.002 · Cited by 16
Sensory restoration for improved motor control of prostheses
Fisher, L. E., Gaunt, R. A., & Huang, H. (2023) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2023.100498 · Cited by 22
Self-citationChen, K., Forrest, A. M., Burgos, G.-G., & Kozai, T. D. Y. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad5049 · Cited by 18
“Intracortical microelectrodes have demonstrated potential as a therapeutic tool for neurological disorders [3, 4, 10, 13, 17].”
BackgroundXu, Q., Xi, Y., Wang, L., Du, Z., Xu, M., Ruan, T., Cao, J., Zheng, K., Wang, X., Yang, B. T., et al. (2024) · ACS Nano · doi:10.1021/acsnano.4c07379 · Cited by 20
Applying the IEEE BRAIN neuroethics framework to intra-cortical brain-computer interfaces
Soldado-Magraner, J., Antonietti, A., French, J., Higgins, N., Young, M. J., Larrivee, D., & Monteleone, R. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad3852 · Cited by 16
“In particular, direct brain stimulation of somatosensory areas in the human brain has been performed to artificially deliver sensory information into the brain and, with this, restore proprioception, facilitating motor control [29].”
Bouton, C. E., Bhagat, N. A., Chandrasekaran, S., Herrero, J. L., Markowitz, N., Espinal, E., Kim, J.-W., Ramdeo, R., Xu, J., Glasser, M. F., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.699631 · Cited by 16
“A brain-computer interface (BCI), which links the brain directly to a computer, offers a new way to study the brain and potentially restore impairments in patients living with these debilitating conditions.”
BackgroundInfluentialThe brain-reading devices helping paralysed people to move, talk and touch
Drew, L. (2022) · Nature · doi:10.1038/d41586-022-01047-w · Cited by 19
Sensor-Based Rehabilitation in Neurological Diseases: A Bibliometric Analysis of Research Trends
Facciorusso, S., Spina, S., Reebye, R. N., Turolla, A., Calabrò, R. S., Fiore, P., & Santamato, A. (2023) · Brain Sciences · doi:10.3390/brainsci13050724 · Cited by 19
The convergence of neuromodulation and brain–computer interfaces
Herron, J. A., Křemen, V., Simeral, J. D., Dawes, H. E., Worrell, G. A., Starr, P. A., Denison, T., & Borton, D. A. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00187-0 · Cited by 23
Preserved cortical somatotopic and motor representations in tetraplegic humans
Andersen, R. A., & Aflalo, T. (2022) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2022.102547 · Cited by 19
Recent advances and challenges of tactile sensing for robotics: from fundamentals to applications
Zhan, Z., Yang, Y., Zuo, W., Xie, M., & Ning, M. (2025) · Materials Today Physics · doi:10.1016/j.mtphys.2025.101740 · Cited by 32
Two-Dimensional MXene-Based Advanced Sensors for Neuromorphic Computing Intelligent Application
Lin, L., Sun, B. N., Wang, Z., Meng, J., & Wang, T. (2025) · Nano-Micro Letters · doi:10.1007/s40820-025-01902-1 · Cited by 21
“Inspired by biological sensory principles, artificial synaptic electronic devices have demonstrated extensive multisensory functionality within neuromorphic computing platforms [116–121].”
Smith, T. J., Wu, Y., Cheon, C., Khan, A. A., Srinivasan, H., Capadona, J. R., Cogan, S. F., Pancrazio, J. J., Engineer, C. T., & Hernandez-Reynoso, A. G. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1202258 · Cited by 14
Mind-Controlled Optical Manipulation
Peng, L., Yao, J., Bai, Y., Sun, Y., Zeng, J., Ren, Y., Xie, J., Hu, Z., Zhang, Q., & Yang, Y. (2024) · ACS Photonics · doi:10.1021/acsphotonics.3c01732 · Cited by 18
Yan, W., Zhao, T., & Wu, E. Q. (2024) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2024.3496699 · Cited by 16
“In fact, it is difficult to preadjust the direction of initial control input in brain-computer interactions [47].”
Wang, T., Chen, Y., Wang, Y., Lee, S., Lee, Y., & Dong, J. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202400142 · Cited by 19
Future Developments in Brain/Neural–Computer Interface Technology
Soekadar, S. R., Vermehren, M., Colucci, A., Haslacher, D., Bublitz, C., Ienca, M., Chandler, J. A., & Blankertz, B. (2023) · Advances in neuroethics · doi:10.1007/978-3-031-26801-4_5 · Cited by 20
Ghosh, S., Sindhujaa, P., Kesavan, D. K., Gulyás, B. Z., & Máthé, D. (2025) · Surgeries · doi:10.3390/surgeries6030050 · Cited by 17
“This advancement significantly enhances the user’s ability to interact with their environment by providing real-time sensory input alongside motor control [84].”
Tissue-like Bioelectronic Material Strategies for Personalized Closed-Loop Neuroprostheses
Kim, Y., Lee, H., Lee, J., Shin, M., & Son, D. (2025) · ACS Nano · doi:10.1021/acsnano.5c07150 · Cited by 20
Advances in flexible high-density microelectrode arrays for brain-computer interfaces
Ban, S., Chong, D., Kwon, J., Lee, S., Huang, Y., Yoo, S., & Yeo, W. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.118102 · Cited by 15
Abbasi, A., Lassagne, H., Estebanez, L., Goueytes, D., Shulz, D. E., & Ego‐Stengel, V. (2023) · Science Advances · doi:10.1126/sciadv.adh1328 · Cited by 18
“This is consistent with recent work exploring cortical somatosensory closed-loop brain-machine interfaces in humans with intra-cortical electrical stimulations ( 8 ), as well as with previous work emphasizing the prevalent role of ongoing sensory feedback in motor learning ( 31 , 34 ).”
InfluentialA low‐voltage‐driven, neuromorphic sensorimotor loop for monolithic soft prosthetic e‐skin
Li, X., Mehvish, D., & Yang, H. (2024) · SmartMat · doi:10.1002/smm2.1248 · Cited by 14
Intelligent Neural Interfaces: An Emerging Era in Neurotechnology
Shoaran, M., Shin, U., & Shaeri, M. (2024) · Custom Integrated Circuits Conference · doi:10.1109/cicc60959.2024.10529099 · Cited by 21
“Empowered by advanced AI algorithms, recent BMIs have demonstrated the decoding of brain activity associated with various movements and actions, including gait, reach-and-grasp, cursor control, typing, handwriting, and speech [15-18, 23, 24, 67-70].”
BackgroundJin, C., Song, A. H., & Kim, S. (2024) · IEEE Access · doi:10.1109/access.2024.3406736 · Cited by 17
“The brain-computer interface (BCI) is an emerging technology that interprets neural activities and controls external devices, including electric wheelchairs, prostheses, robotic arms, spellers, and drones [1], [2], [3], [4], [5].”
BackgroundLi, W., Yang, L., Huang, J., Zheng, C., Chen, Y., Li, Y., Yang, D., Li, S., Chen, Z., Cai, W., et al. (2024) · Industrial Chemistry and Materials · doi:10.1039/d4im00048j · Cited by 16
Lim, M. J. R., Lo, Y. T., Tan, Y. Y., Lin, H.-Y., Wang, Y., Tan, D., Wang, E., Ma, Y. Y. N., Ng, J. J. W., Jefree, R. A., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adb88e · Cited by 20
“As discussed earlier, iBCIs for motor recovery evaluated a range of tasks, from standardized tests such as the ARAT [58, 67, 134], or a test battery of tasks designed by the research team [23, 69, 135].”
5-year follow-up of a fully implanted brain–computer interface in a spinal cord injury patient
Davis, K., Wyse‐Sookoo, K., Raza, F., Meschede-Krasa, B., Prins, N. W., Fisher, L., Brown, E. N., Cajigas, I., Ivan, M. E., Jagid, J. R., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adc48c · Cited by 19
Peripheral neurostimulation for encoding artificial somatosensations
Valle, G. (2022) · European Journal of Neuroscience · doi:10.1111/ejn.15822 · Cited by 18
“Indeed, the application of intracortical microstimulation (ICMS) to the human cortex has been shown to evoke stable and nearly natural tactile sensations experienced at specific locations on the (otherwise insensate) hand (Flesher et al., 2016, 2021; Salas et al., 2018).”
BackgroundEngineering Steep Subthreshold Swings in High‐Performance Organic Field‐Effect Transistor Sensors
Wang, Y., Huang, W., Li, J., Liu, S., Fu, J., Wang, L., Wang, H., Li, W., Xie, L., Ling, H., et al. (2024) · Small · doi:10.1002/smll.202406522 · Cited by 15
ArmBCIsys: Robot Arm BCI System With Time–Frequency Network for Multiobject Grasping
Yu, F., Rao, Z., Chen, N., Liu, L., & Jiang, M. (2025) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2025.3579332 · Cited by 15
“In recent years, advancements in neuroscience, artificial intelligence, and electronic engineering have led to signifi-cant progress in brain–computer interface (BCI) technology [6], o ff ering new rehabilitation approaches for patients with impaired limb functionality [7].”
Li, J., Zhang, W., Liao, Y., Qiu, Y., Zhu, Y., Zhang, X., & Wang, C. (2025) · Physics of Life Reviews · doi:10.1016/j.plrev.2025.08.007 · Cited by 20
Zhou, E., Wang, X., Liang, J., Liu, Y., Yang, Q., Ran, X., Xia, L., Zou, X., Liu, C., Sun, L., et al. (2025) · Advanced Science · doi:10.1002/advs.202506663 · Cited by 19
Collaborative AI for precision neurorehabilitation: a roadmap
Liew, S., Cotton, R. J., Burdet, E., Badia, S. B. I., Celnik, P. A., Cole, J. H., Liu, R., Soekadar, S. R., Winstein, C. J., & Schweighofer, N. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01810-w · Cited by 18
“This bidirectional interaction approach enhances the functionality of prosthetic limbs [76].”
Kunigk, N. G., Urdaneta, M. E., Malone, I. G., Delgado, F., & Otto, K. J. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.876142 · Cited by 17
Zhou, L.-R., Feng, Z., Wang, H.-Y., & Guo, Q. (2023) · International journal of human computer interactions · doi:10.1080/10447318.2023.2247606 · Cited by 9
“Flesher et al. (Flesher et al., 2021) embedded their developed brain-6078 computer interface-controlled prosthetic system into a paralyzed.”
Robot Motion Planning Based on Improved RRT Algorithm and RBF Neural Network Sliding
Cao, M., Zhou, X., & Ju, Y. (2023) · IEEE Access · doi:10.1109/access.2023.3327915 · Cited by 14
“An increasing amount of research is devoted to issues such as human-robot collaboration, planning in dynamic environments, and enhancing learning capabilities [3], [4], [5].”
BackgroundEnhancing the online estimation of finger kinematics from sEMG using LSTM with attention mechanisms
Wang, Z., Xiong, C., & Zhang, Q. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.105971 · Cited by 15
Metadata
- Authors
- Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A.
- Affiliations
- University of Pittsburgh (US)
- Department of Neurosurgery, University of Texas at Austin, Austin, TX, USA.
- United States Department of Veterans Affairs (US)
- Corresponding author
- Flesher, Sharlene N.
- ORCID
- Venue
- Science
- Published
- 2021-05-21
- Volume
- 372
- Issue
- 6544
- Pages
- 831-836
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- PMC
- PMC8715714
- OpenAlex
- W3161143221
- Cited by
- 617
- References
- 40
- Citations by year
- 2026: 102 · 2025: 154 · 2024: 131 · 2023: 102 · 2022: 75 · 2021: 41
- FWCI
- 45.79
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- Science (publishedVersion)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Defense Advanced Research Projects Agency (N66001-16-C-4051, N66001-10-C-4056)
- National Science Foundation (DGE-1247842)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- brain-computer interface, tactile feedback, robotic arm control, tetraplegia, intracortical microstimulation, somatosensory cortex, motor cortex, upper limb prosthesis, grasping, bidirectional neural interface
- MeSH terms
- Adult, Arm, Artificial Limbs, Humans, Male, Motor Cortex, Movement, Quadriplegia, Robotics, Somatosensory Cortex, Touch, Hand Strength, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.