A brain-computer interface that evokes tactile sensations improves robotic arm control
Open accessPublished version of a preprint
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index; 5 of the 15 sources its claims cite were checked for support.
Abstract
Prosthetic arms controlled by a brain-computer interface can enable people with tetraplegia to perform functional movements. However, vision provides limited feedback because information about grasping objects is best relayed through tactile feedback. We supplemented vision with tactile percepts evoked using a bidirectional brain-computer interface that records neural activity from the motor cortex and generates tactile sensations through intracortical microstimulation of the somatosensory cortex. This enabled a person with tetraplegia to substantially improve performance with a robotic limb; trial times on a clinical upper-limb assessment were reduced by half, from a median time of 20.9 to 10.2 seconds. Faster times were primarily due to less time spent attempting to grasp objects, revealing that mimicking known biological control principles results in task performance that is closer to able-bodied human abilities.
Overview
CoChat Summary
TL;DR
A bidirectional brain-computer interface that decoded motor intent and delivered intracortical microstimulation to somatosensory cortex improved a person with tetraplegia’s control of a robotic arm. Adding tactile feedback reduced median ARAT trial time from 20.9 to 10.2 s and improved median ARAT score from 17 to 21.
Key findings
- With ICMS-evoked tactile feedback, median ARAT score was 21 versus 17 without ICMS (p = 0.029, Wilcoxon rank-sum test), and higher than 23 prior sessions without ICMS (p = 0.005).
- Successful ARAT trial times decreased by 51.2%, from a median of 20.9 s to 10.2 s (p < 0.0001); grasp time decreased by 66%, from 13.3 s to 4.6 s, accounting for 88% of the total improvement.
- A score of 3, indicating object transfer in under 5 s, was achieved 15 times with tactile feedback versus once across all 108 trials without it; 14% of trials with tactile feedback were faster than the fastest trial without ICMS.
- In the object transfer task, time in the object zone decreased by 30.3%, from 3.3 ± 1.2 s to 2.3 ± 0.4 s per transfer (p = 0.002), and hand movement in the object zone decreased from 44.2 ± 13.1 to 32.4 ± 5.9 cm per transfer (p = 0.0007); total transfers increased from 315 without ICMS to 352 with ICMS, but transfers per trial did not significantly differ (15.8 ± 3.8 to 17.8 ± 2.4, p = 0.050).
Methods
- Single participant: a 28-year-old male with tetraplegia due to C5 motor/C6 sensory ASIA B spinal cord injury sustained 10 years before consent; study conducted under FDA Investigational Device Exemption and registered at ClinicalTrials.gov (NCT01894802).
- Two 88-electrode arrays were implanted in motor cortex hand/arm region to decode movement intent, and two 32-electrode arrays were implanted in area 1 of somatosensory cortex; a new 5 degree-of-freedom velocity decoder was trained daily, and ICMS was driven in real time by robotic hand sensors responding to object contact and grasp force.
- Performance was compared with and without ICMS on a modified ARAT with nine tasks, each object attempted three times per session and scored 0–3 with maximum score 27, using four sessions with ICMS and four without plus 23 prior sessions; an object transfer task was also performed in four sessions with and four without ICMS, five times per session, with Wilcoxon rank-sum and t-tests used for comparisons.
Limitations
- The paper states that this is a single-subject study and it is not guaranteed that findings will generalize to future experiments and participants.
- The paper states that future work should examine how stimulation encoding design, such as proportional versus on-off feedback, affects performance, and notes that many objects were rigid with no penalty for grasping too firmly, so fragile objects or more precise hand posture/grasp force control could depend more on specific sensory encoding schemes.
- Evident from the text: the participant had only one grasp dimension that opened and closed all fingers as a group, and some smaller objects were difficult to pick up because the fingertips often contacted objects rather than the distal phalanx pads, making grasp less stable; the increase in transfers per trial with ICMS was not statistically significant (p = 0.050).
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
3 Valid · 0 Not valid · 7 Not checked · 32 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“First, using the same fundamental neural decoding and control methods, two participants have achieved similar scores on functional tasks with vision alone (5, 6, 28).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Partly supportedcites [5] Wodlinger B, J. Neural Eng 12, 016011 (2015). 25514320 sourceExperimental — accuracy not yet measured
Section 3.4 reports similar functional-task scores under 7D and 10D control, but both scores are from the same participant. Section 2.2 identifies a single participant; this paper therefore does not establish the claim about two participants achieving similar scores with vision alone. Page numbers are unavailable in our copy. (LLM, conf=0.88)
- Partly supportedcites [6] Collinger JL, Lancet (London, England) 381, 557– 64 (2013). PMC3641862 23253623 sourceExperimental — accuracy not yet measured
The Methods (Observation-based calibration and neural decoding; Functional brain-control tasks) describe neural decoding and functional testing, and the Results (Clinical assessments) report an ARAT score of 15–17 for one participant. This paper does not establish that two participants achieved similar scores, and the retrieved passages do not explicitly say the tasks were performed with vision alone. (LLM, conf=0.84)
- Partly supportedcites [28] Downey JE, Sci. Rep 7, 16947 (2017). 29209023 PMC5717217 sourceExperimental — accuracy not yet measured
The Methods (Study participants; Neural recording and BCI decoder calibration, page unavailable) describe two participants using motor-cortex decoding to control a robotic arm; somatosensory arrays were not used in this experiment. The Results (Online population-level scaling improves BCI object grasping, page unavailable) report fairly close object-interaction success rates with scaling, but the more functional object-transport scores differ substantially: 1.09 versus 5.28 transfers per minute. Thus, the paper does not support a general claim that the participants achieved similar scores on functional tasks. (LLM, conf=0.86)
plainn = 2- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“In contrast, ICMS feedback in a relevant area of cortex, but in an unintuitive way, requires considerable learning time (thousands of trials) to use effectively (33).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Supportedcites [33] Dadarlat MC, O’Doherty JE, Sabes PN, Nat. Neurosci 18, 138– 44 (2015). 25420067 PMC4282864 source
The Results (Behavioral task and feedback signals) describe ICMS in somatosensory cortex, with electrode directions assigned independently of local neuronal responses. The Discussion (Learning to integrate a novel sensory signal) says the patterns did not mimic naturally occurring signals and had to be learned. Online Methods (Experimental Design) reports approximately 20,000 and 40,000 training trials before the two monkeys showed clear evidence of integrating ICMS with vision. (LLM, conf=0.94)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“it is only in recent studies of humans with chronically implanted microelectrode arrays that the perceptual characteristics of microstimulation have been elucidated (19, 20).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Not checked — no full text of the sourcecites [19] Flesher SN, Sci. Transl. Med 8, 361ra141 (2016). 27738096 source
- Supportedcites [20] Salas MA, Elife 7 (2018), doi: 10.7554/eLife.32904. source
The Abstract describes recent human ICMS studies and reports sensations elicited in a person with two implanted microelectrode arrays. Materials and methods (Task) describes how the participant reported each percept’s location, intensity, duration, and qualitative character; Results and discussion reports the resulting percept measurements. These passages support the claim that such human studies elucidated the perceptual characteristics of microstimulation. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Further, 14% of the trials with tactile feedback were completed more quickly than the very fastest trial without ICMS (Fig. 2C).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The time spent in the object zone (Fig. 1G) decreased by 30.3%, from 3.3 ± 1.2 s per transfer without ICMS to 2.3 ± 0.4 s per transfer with ICMS (p = 0.002, t-test, Fig. 3A).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
plainstates a causeSingle case ·- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
19 more claims
Create a free account to see all 42 claims and every source verdict.
- It may state two separate claims as one. 15
- Probably not a substantial claim. 3
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Generalized Inverses, Ridge Regression, Biased Linear Estimation, and Nonlinear Estimation
Marquardt, D. W. (1970) · Technometrics · doi:10.1080/00401706.1970.10488699 · Cited by 2,276
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Self-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Lyle, R. C. (1981) · International Journal of Rehabilitation Research · doi:10.1097/00004356-198112000-00001 · Cited by 1,326
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Research works printed but not linked: 2
- J. M. Loomis R. L. Klatzky N. A. Giudice in Assistive Technology for Blindness and Low Vision R. Manduchi S. Kurniawan Eds. (CRC Press 2012).
- M. S. Johannes, J. D. Bigelow, J. M. Burck, S. D. Harshbarger, M. V. Kozlowski, T. Van Doren, An overview of the developmental process for the modular prosthetic limb. Johns Hopkins APL Tech. Dig. 30, 207–216 (2011).
Cited by
Items 401–500 of 615
Touching the Void: Intracranial Stimulation for NeuroHaptic Feedback in Virtual Reality
Paschall, C. J., Hauptman, J. S., Rao, R. P. N., Ojemann, J. G., & Herron, J. A. (2022) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc53654.2022.9945366 · Cited by 3
“Understanding the neural dynamics governing cognitive integration of S1DCS may improve stimulation delivery and design [17] and may offer insight into the learning mechanisms significant for the development of bidirectional BCI [18].”
BackgroundConcealing-Restoring System for Analog Images
Fujii, T., Yamamoto, S., Yamasaki, T., et al. (2023) · International Conference on Electrical, Computer and Energy Technologies (ICECET) · doi:10.1109/icecet58911.2023.10389575 · Cited by 2
Mukaeda, T., & Shima, K. (2023) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc53992.2023.10394622 · Cited by 2
“Today’s developments in AI technology have supported the advancement of man-machine interfaces involving the use of biological signals (such as brain-machine interfaces (BMIs) [1], myoelectric prosthetic hands [2] and eye-gaze input devices [3]).”
BackgroundAn 112-Ch Neural Signal Acquisition SoC With Full-Channel Read-Out and Processing Accelerators
Tang, Z., Guo, Y., Zheng, M., Sun, C., Wu, Y., Fang, R., Fang, Y. Z., & Zhang, M. (2024) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2024.3396774 · Cited by 3
“with sensory [1], motor [2], and cognitive operations [3].”
BackgroundAbbasi, A., Lassagne, H., Estebanez, L., Goueytes, D., Shulz, D. E., & Ego‐Stengel, V. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2019.12.12.873794 · Cited by 4
Faisal, A. A. (2021) · Science · doi:10.1126/science.abi7262 · Cited by 2
Human single neuron recordings
Fu, Z., & Rutishauser, U. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-820480-1.00002-4 · Cited by 3
Ruszala, B. M., Mazurek, K. A., & Schieber, M. H. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.08.05.552025 · Cited by 3
“In bidirectional brain-computer interfaces (O'Doherty et al., 2011; Flesher et al., 2021; Pandarinath and Bensmaia, 2022), for example, ICMS delivered in the primary somatosensory cortex (S1) to provide artificial tactile feedback might modulate the discharge of M1 neurons being used to decode…”
BackgroundMethodSingle and Multi-Site Cortical Stimulation Related to Human Sensorimotor FunctionPreprint
Ryun, S., & Chung, C. K. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.01.18.574786 · Cited by 2
Iwata, T., Nakamura, H., Uemura, T., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.08.29.610418 · Cited by 2
Kim, K., Sonego, V., Strohmer, B., Chang, B., Liu, X., Yonza, A. K. I., Kucharz, K., Asiminas, A., Lind, B. L., Tao, L., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.06.25.661479 · Cited by 1
Park, S., Lipton, M. H., Sun, Y. J., & Dadarlat, M. C. (2024) · STAR Protocols · doi:10.1016/j.xpro.2024.103027 · Cited by 1
Wu, Y., Hernández, M. F., Lei, T., Jayakumar, S., Lalapet, R. R., Joshi‐Imre, A., Orazem, M. E., Otto, K. J., & Cogan, S. F. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781914 · Cited by 1
Invasive Brain–Computer Interfaces: 25 Years of Clinical Trials, Scientific and Practical Issues
Mokienko, O. A. (2024) · Annals of the Russian academy of medical sciences · doi:10.15690/vramn17994 · Cited by 1
Systems-on-Chips for Invasive Brain-Computer Interfaces: Challenges and Opportunities
Yang, J., & Sawan, M. (2024) · IEEE International Conference on Solid-State and Integrated Circuit Technology · doi:10.1109/icsict62049.2024.10831917 · Cited by 1
“1, these invasive systems can send stimuli into the brain to modulate neural activity for treating brain diseases [1] or provide sensory input to restore functions such as vision [2], hearing, and tactile sensation [3].”
Shared 3D Robotic Arm Control Based on Intracortical Brain-Computer Interface and Computer Vision
Liu, L., Yu, S., Chen, L., Mo, L., Guo, Z., Wang, X., Gao, F., Liang, F., Liao, W., & Yin, M. (2024) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio64047.2024.10907485 · Cited by 1
Neurophysiological Analysis in Motor and Sensory Cortices for Improving Motor Imagination
Kim, S., Kim, S.-J., & Lee, D.-H. (2025) · International Conference on Brain-Computer Interface (BCI) · doi:10.1109/bci65088.2025.10931728 · Cited by 1
“Recent studies have highlighted the potential for sense–related information to enhance the decoding of motor– related information [19].”
de Araújo, A. F. M. (2025) · AI and Ethics · doi:10.1007/s43681-025-00737-1 · Cited by 2
“Brain-computer interface (BCI) would be modelled on a device [ 8 , 9 ] — e.g. elec - trode grids inside the cortex — than uses algorithms for tracking, scanning, translate and convert neuronal data into pictograms/pixels set (non-verbal [ 7 ] ludic communication) able of architecting display…”
Zhang, Q., Liu, B., Wang, Z., Zhou, J., Yang, X., Zhou, Q., Zhao, Y., Li, S., Zhou, J., & Wang, C. (2025) · Advanced Science · doi:10.1002/advs.202503011 · Cited by 2
New Applications of Neurotechnologies for Neurological Disorders
Orsborn, A. L., Pirondini, E., Capogrosso, M., Gaunt, R. A., & Stavisky, S. D. (2025) · Springer eBooks · doi:10.1007/978-3-031-89307-0_25 · Cited by 1
Self-citationRethink the motor cortical control via the experiment-analysis-model flywheel: an overview
Jiang, H., Bu, X., Shi, Q., Zheng, Z., Zhu, D., Tang, H., & Chen, Y. (2025) · Med-X · doi:10.1007/s44258-025-00059-1 · Cited by 1
“Besides, a team from the University of Pittsburgh [166] developed a bidirectional iBCI that records neural activity from the motor cortex and generates tactile sensations evoked through somatosensory cortical stimulation.”
Semantics of Brain-Machine Hybrids
Ikegaya, Y. (2025) · Biological and Pharmaceutical Bulletin · doi:10.1248/bpb.b25-00285 · Cited by 1
Enabling Neuroprostheses via Machine Learning
Chen, Q., Lin, P., Yu, Z., & Pan, G. (2025) · Machine Intelligence Research · doi:10.1007/s11633-025-1571-3 · Cited by 2
Ruszala, B. M., Mazurek, K. A., & Schieber, M. H. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae087e · Cited by 2
Quantitative assessment of dynamic movement reveals deficits due to hemiparetic stroke
Kalinowska, A., Schlafly, M., Rudy, K., Dewald, J. P. A., & Murphey, T. D. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01719-4 · Cited by 1
“We know that real-time perception and processing of sensory information is crucial for effective motor coordination [73].”
3D directional tuning in the orofacial sensorimotor cortex during natural feeding and drinking
Hosack, V. B., & Arce‐McShane, F. I. (2025) · eLife · doi:10.7554/elife.101325.3 · Cited by 1
Neural population dynamics of direct electrical stimulation of neocortex
Hickman, J. L., Hughes, G., Sahai, E., Miles, M., & Denman, D. J. (2026) · Cell Reports · doi:10.1016/j.celrep.2026.117420 · Cited by 1
Rubin, D. B. (2025) · Neuron · doi:10.1016/j.neuron.2025.10.013 · Cited by 1
Fu, Z., Zhang, P., He, X., Wang, H., Guo, Y., Chen, X., & Huang, J. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3640764 · Cited by 2
“…signals from the brain into specific motor intentions and converts these intentions into execution instructions to control external assistive devices (such as robotic arms, prosthetics, wheelchairs, computers, etc.), to help individuals with movement disorders rebuild their motor function [5], [6].”
From Restoration to Augmentation: New Approaches to Haptic Feedback for Artificial Limbs
Dowdall, L., Foster, C., & Makin, T. R. (2025) · IEEE Transactions on Haptics · doi:10.1109/toh.2025.3641707 · Cited by 1
“Intracortical microstimulation (ICMS), which involves delivering direct electrical pulses to S1 viachronicallyimplantedmicroelectrodearrays,hasbeenshown toevoketactileperceptsthatpatientslocalizetothemissing orparalyzedlimb[9].”
A 1024-Channel 0.8V 23.9-nW/Channel Event-Based Compute In-Memory Neural Spike Detector
Ke, Y., Fu, Z., Yang, J., Shang, H., & Basu, A. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3642865 · Cited by 4
“I NTRACORTICAL brain machine interfaces (iBMIs) have shown promising utilities in interfacing the human brain with external devices for prosthetic and cursor control [1], speech decoding [2], and tactile sensations [3] in the last few decades.”
Unveiling interactions of spatial-temporal information in tactile motion perception
Qu, B., Tan, X., Tang, Z., Wang, H., Lan, L., Schriver, K. E., Pan, G., Friedman, R. M., & Lai, H.-Y. (2025) · Scientific Reports · doi:10.1038/s41598-025-28038-x · Cited by 2
A Tongue‐Computer Tactile Interface Mediated by the Magnetoelectric‐Driven Tribovoltaic Sensors
Zhao, J., Tang, C., Zhou, M., Yu, D., Chen, M., Wang, S., Hu, Q., Jiang, Z., Wang, Z. L., Pu, X., et al. (2026) · Advanced Materials · doi:10.1002/adma.202522639 · Cited by 2
Spiking neural network for intra-cortical brain signal decoding
Yang, S., Fu, H., Zhang, H., Zhang, P., Li, W., & Wu, D. (2026) · Knowledge-Based Systems · doi:10.1016/j.knosys.2026.115508 · Cited by 5
Perilesional neuromodulation replaces lost sensorimotor function in persons with spinal cord injury
Calvert, J. S., Parker, S. R., Govindarajan, L. N., Darie, R., Shaaya, E. A., Solinsky, R. J., Valle, L. M. D., Miranda, P., Jang, J., Tiwari, E., et al. (2026) · Nature Biomedical Engineering · doi:10.1038/s41551-026-01627-5 · Cited by 7
Large-scale single-neuron recording in the human cortex using an ultra-flexible electrode array
Wu, S. P., Yan, Z., Kong, C., Jiang, X., Dong, Q., Qian, Y., Chen, G., Chen, B., Ren, C., Lu, J., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-71443-7 · Cited by 8
Ding, W., Chen, W., Chen, G., Chen, Y., Xia, X., Kang, W., Liu, Z., Li, Y., & Yang, W. (2026) · International Journal of Smart and Nano Materials · doi:10.1080/19475411.2026.2672486 · Cited by 1
A holistic perspective on noninvasive brain–computer interfaces
Ding, Y., Kosnoff, J., & He, B. (2026) · Trends in Neurosciences · doi:10.1016/j.tins.2026.04.009 · Cited by 4
Restoring vision and touch with cortical microstimulation
Valle, G., Oswalt, D. N., Gaunt, R. A., Roelfsema, P. R., Greenspon, C. M., & Fernandez, E. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00449-z · Cited by 2
“Nevertheless, implantation studies showed that somatosensory feedback increased confidence in object contact and improved grasp-and-transport performance 128 (Fig.”
Self-citationMeyer, L. M., & Zamani, M. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae6dfd · Cited by 1
Mechanisms of premotor-motor cortex interactions during movement initiation
Alyahyay, M., Ammer, J. J., Kalweit, G., Zhu, H., Adžemović, A., Kalweit, M., Karvat, G., Schneider, A., Tong, Y., Döbrössy, M. D., et al. (2026) · Cell Reports · doi:10.1016/j.celrep.2026.117542 · Cited by 2
Wang, M., Shang, S., Xu, Y., Zhou, C., You, X., Jiang, H., Fan, X., Zhou, X., Wang, W., Zhang, W., et al. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118987 · Cited by 1
Long-term safety and efficacy of intracortical microstimulation in humans
Greenspon, C. M., Hobbs, T. G., Verbaarschot, C., Alamri, A. H., Shelchkova, N. D., Lienkämper, R., Ye, J., Simpson, T. W., Weiss, J. M., Weir, D., et al. (2026) · Science Translational Medicine · doi:10.1126/scitranslmed.aec3728 · Cited by 8
Self-citationAdvancing data protections for implantable brain-computer interfaces
Sandbrink, J. D., & Young, M. J. (2026) · Communications Medicine · doi:10.1038/s43856-026-01797-y · Cited by 2
Francis, J. T., Rozenboym, A. V., von Kraus, L. M., Xu, S., Chhatbar, P. Y., Semework, M., Hawley, E. S., & Chapin, J. K. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.812837 · Cited by 1
Getting a grasp on BMIs: Decoding prehension and speech signals
Edmondson, L. R., & Saal, H. P. (2022) · Neuron · doi:10.1016/j.neuron.2022.05.004 · Cited by 1
“the ability to move external limbs but also to feel tactile sensations elicited by object interactions (Flesher et al., 2021).”
BackgroundThe Future of Brain–Computer Interfaces
Abrams, Z. (2022) · IEEE Pulse · doi:10.1109/mpuls.2022.3227806 · Cited by 1
“By implanting electrodes in the somatosensory area of the brain, the BCI can generate sensations that feel as if they’re coming from a participant’s hand, a key source of feedback we use when manipulating objects [3].”
BackgroundSomatosensory Neuromodulation with a Focus Towards Clinical Systems
Graczyk, E. L., & Tyler, D. J. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_92 · Cited by 1
Review of Brain-Computer Interface Technology
刘, 珈. (2023) · Artificial Intelligence and Robotics Research · doi:10.12677/airr.2023.121003 · Cited by 1
Kim, Y. H., Koo, H., Kim, M. S., & Jung, S.-D. (2023) · Biomaterials Advances · doi:10.1016/j.bioadv.2023.213629 · Cited by 1
Advancing Brain-Machine Interfaces: High Data Rate Battery-Free Implants
Hasanvand, A., Khaleghi, A., Balasingham, I., Wanda, P. A., & Beguet, C. (2023) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc56839.2023.10305091 · Cited by 1
“Invasive, implanted BMI devices are likely more stable and reliable over time and would be suggested for long-term use [2].”
Unlocking ALS Insights with the Power of Artificial Intelligence and Machine Learning
Khanna, R. (2023) · International Conference on Electrical, Electronics, Communication and Computers (ELEXCOM) · doi:10.1109/elexcom58812.2023.10370277 · Cited by 1
“Ease of Use was the primary focus, developed in 1970, the Lightspot Operated Typewriter which used small head movements to point a small spot of light at a matrix of characters, each with a photoelectric cell[3].”
BackgroundMethodBrain-Controlled Assistive Robotics and Prosthetics
Puthuveetil, K. P., & Krusienski, D. J. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-87865-4.00010-8 · Cited by 1
Suo, D., Li, W., & Yan, T. (2024) · Brain Science Advances · doi:10.26599/bsa.2024.905001 · Cited by 5
“By interpreting the electrical signals produced by the brain, BCIs now allow users to control prosthetic limbs [2], operate computer cursors [3], and even communicate through typing without the need for physical movement [4].”
BackgroundContinuous Control Method for Lower Limb Rehabilitation Robot Based on Self-learning Strategy
Lu, Y., Guo, S., Wang, M., & Chen, L. (2024) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma61710.2024.10633063 · Cited by 1
“In contrast, leveraging Brain-computer Interface (BCI) technology allows for continuous strengthening of neural central stimulation feedback for neurorehabilitation, coupled with robotic assistance, facilitating neural reshaping and significantly enhancing rehabilitation outcomes [7,8].”
BackgroundOn Security Level of Some Secret Keys of Concealing - Restoring System Aimed to BCI/BMI Security
Fujii, T., Yamamoto, S., Yamasaki, T., et al. (2024) · doi:10.1109/icecet61485.2024.10698034 · Cited by 1
“The development of BCI/BMI has lately been remarkable [1], [2].”
BackgroundReducing power requirements for high-accuracy decoding in iBCIs
Karpowicz, B. M., Bhaduri, B., Nason, S. R., Jacques, B. G., Ali, Y. H., Flint, R. D., Bechefsky, P. H., Hochberg, L. R., Yong, N. A., Slutzky, M. W., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad88a4 · Cited by 1
The quest to build bionic limbs that feel like the real thing
Schwaller, F. (2024) · Nature · doi:10.1038/d41586-024-03675-w · Cited by 1
Multi-Electrode ICMS Enables Dexterous Use of Bionic Hands
Shelchkova, N. D., Valle, G., Hobbs, T. G., Verbaarschot, C., Downey, J. E., Gaunt, R. A., Bensmaïa, S. J., & Greenspon, C. M. (2025) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-031-80497-7_4 · Cited by 1
Self-citationTime-Domain Versus Frequency-Embedded EEG Sequences for Sensorimotor BCI Using 1D-CNN
Saha, S., Baumert, M., & McEwan, A. L. (2025) · IEEE Access · doi:10.1109/access.2025.3595953 · Cited by 2
“Thus, a MI-BCI is used to rehabilitate people with upper/lower limb disabilities as well as providing assistive technologies for healthy individuals [1], [2], [3], [4].”
Responsible neural technology development: ethical issues and challenges
Levy, L., Wexler, A., & Feinsinger, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24824-5.00013-2 · Cited by 2
Classification of Tactile Perception and Attention on Natural Textures from EEG SignalsPreprint
Kim, M.-K., Cho, J.-H., & Jeong, J.-H. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2012.06206 · Cited by 1
Sombeck, J. T., Heye, J. O., Kumaravelu, K., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.11.22.469555 · Cited by 1
“Using a robotic arm, the patient was able to pick up, move, and place objects faster using vision combined with ICMS feedback than with visual feedback alone, primarily because they spent less time attempting to grasp the object (Flesher et al. 2021).”
BackgroundMethodInfluentialCu, H., Lynch, L., Huang, K. B., et al. (2022) · Research Square · doi:10.21203/rs.3.rs-1201096/v1 · Cited by 1
Brain-Controlled Electrical Stimulation Restores Continuous Finger FunctionPreprint
Nason, S. R., Mender, M. J., Kennedy, E., Lambrecht, J. M., Kilgore, K. L., Chiravuri, S., Kumar, N. G., Kung, T. A., Willsey, M. S., Chestek, C. A., et al. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.06.15.496349 · Cited by 1
Balasubramanian, K., Arce‐McShane, F. I., Dekleva, B. M., et al. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4108216 · Cited by 1
“Additional details regarding his implant can found in previous studies 33 that occurred prior to the experiments presented here.”
ResultSelf-citationCortical reorganization in the adult primary sensorimotor cortex
Kikkert, S., Root, V., Buehler, S., & Makin, T. R. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-820480-1.00004-8 · Cited by 1
A Triboelectric Tactile Sensor with Flower-Shaped Holes for Texture RecognitionPreprint
Xing, P., An, S., Wu, Y., et al. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4481004 · Cited by 1
In Vivo Recording of Visually Evoked Potentials with Novel Full Diamond Ecog ImplantsPreprint
Wilfinger, C., Zhang, J., Nguyen, D., et al. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4630713 · Cited by 1
Extending tactile space with hand-held tools: A re-analysis and reviewPreprint
Miller, L. E., & Farnè, A. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.04.01.587537 · Cited by 1
“Typically, this involves sensorizing the prosthesis and using the sensor read-out to drive tactors (Kuiken et al ., 2007; Marasco et al ., 2011), nerve stimulation (George et al ., 2019), or neural implants (Flesher et al ., 2021).”
Human Single Neuron RecordingsPreprint
Fu, Z., & Rutishauser, U. (2024) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/57wzm · Cited by 1
Rosenthal, I. A., Bashford, L., Bjånes, D. A., Pejsa, K., Lee, B., Liu, C. Y., & Andersen, R. A. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.05.13.593529 · Cited by 1
“In contrast, broadly viable somatosensory BMIs remain at the proof-of-concept stage (Flesher et al., 2021), although some principles mapping the relationship between ICMS and sensations have emerged.”
BackgroundKomeiji, S., Shigemi, K., Mitsuhashi, T., Iimura, Y., Suzuki, H., Sugano, H., Shinoda, K., Yatabe, K., & Tanaka, T. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.08.21.608927 · Cited by 2
“These targets may include motor actions or motor intentions [1, 2, 3], internal speech [4, 5, 6], or psychological states [7, 8, 9].”
Few-shot Algorithms for Consistent Neural Decoding (FALCON) BenchmarkPreprint
Karpowicz, B. M., Ye, J., Fan, C., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.09.15.613126 · Cited by 1
“This data was used to calibrate an iBCI for control of a robotic arm in a 7 degree-of-freedom task [1, 63, 64].”
MethodSelf-citationDirect Prosthesis Force Control with Tactile Feedback May Connect with the Internal ModelPreprint
Chowdhury, N. H., Schramfield, S., Pariseau, P., & Tyler, D. J. (2024) · medRxiv · doi:10.1101/2024.12.05.24318338 · Cited by 1
Large-scale single-neuron recording using the uFINE array in human cortexPreprint
Wu, S. P., Yan, Z., Kong, C., Li, X., Dong, Q., Qian, Y., Chen, G., Chen, B., Ren, C., Lu, J., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.04.14.648657 · Cited by 1
Cortically Interfaced Human Avatar Enables Remote Volitional Grasp and Shared Discriminative TouchPreprint
Cater, E., Wandelt, S. K., Jangam, A., Elias, Z., Ibroçi, E., Maffei, C., Griffin, D., Bickel, S., Ben-Shalom, N., Stein, A., et al. (2025) · medRxiv · doi:10.1101/2025.09.21.25336267 · Cited by 1
“…5 or maneuver robotic devices 6 in the real-world. iBCIs have also increasingly incorporated sensory feedback 7 – 9 , usually through intracortical microstimulation of primary somatosensory cortex (S1), an essential component for achieving natural and precise interactions with the environment 10 .”
Motor Cortical Output Integrates Distorted Proprioceptive FeedbackPreprint
Li, Y., Xu, X. H., Pan, S., An, X., Mulcahey, P. J., Qiu, Z., Zhao, S., Li, N., Pearson, J., & Huang, Z. J. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.11.11.687832 · Cited by 1
“Artificial sensory feedback can improve operant control and learning 25,26 and persistent forelimb perturbations have demonstrated feedback-driven adaptation 27–29 .”
Preventing Data Leakage in Neural DecodingPreprint
Wong, R., McCullough, M., Lu, T., Zhu, S., & Goodhill, G. J. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.01.26.701583 · Cited by 2
“It is also widely used for neural engineering applications such as brain-computer interfaces (Horikawa & Kamitani, 2017; Wen et al., 2017; Chen et al., 2023a,b) and neuroprosthetics to control movement (Wolpaw & McFarland, 2004; Birbaumer & Cohen, 2007; He et al., 2020; Flesher et al., 2021).”
Huang, J., Narasimha, S. M., Patel, A. N., Sristi, R. D., Mishne, G., & Gilja, V. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.04.02.715749 · Cited by 2
Spatiotemporal encoding of touch signals in the human somatosensory and motor corticesPreprint
Cattabriga, M., Alamri, A. H., Hobbs, T. G., Emonds, A. M., Sobinov, A. R., Gaunt, R. A., Greenspon, C. M., & Valle, G. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.05.08.721831 · Cited by 1
“Finally, studying the functional interactions between the SC and MC has important implications for BCI development, especially in closed-loop scenarios 58 .”
Self-citationBrain Automation, Panacea for Physical Disabilities
Rathna, R. (2020) · International Conference on Computational Performance Evaluation (ComPE) · doi:10.1109/compe49325.2020.9200106
Adaptive Hausdorff Estimation of Movement-Related Eeg Patterns for Brain-Computer InterfacesPreprint
Щербань, И. В., Lazurenko, D. M., Shaposhnikov, D. G., Kirilenko, N. E., Shustova, A. V., & Kiroy, V. N. (2021) · SSRN Electronic Journal · doi:10.2139/ssrn.3915013
Brindha, S. (2021) · Bioscience Biotechnology Research Communications · doi:10.21786/bbrc/14.7.97
Evaluation of Search Strategy for Autonomous Rescue Mobile Robot
Güllü, A., & Kuşçu, H. (2021) · International Conference Automatics and Informatics (ICAI) · doi:10.1109/icai52893.2021.9639868
Multi-person coded brain-computer interface based on steady-state visual evoked potential
Chu, X., Yu, Y., Liu, K., Ye, Z., & Zeng, L. (2021) · China Automation Congress (CAC) · doi:10.1109/cac53003.2021.9727383
Development and Clinical Application of BMI
Yanagisawa, T. (2022) · Japanese Journal of Neurosurgery · doi:10.7887/jcns.31.558
Cyber-Physical Systems Modelling of the Force Feedback Control for a Robotic Surgery Tool
Chua, A. E. C., Bugtai, N. T., & Billones, R. K. C. (2022) · IEEE International Conference on Humanoid, Nanotechnology, Information Technology, Communication and Control, Environment, and Management (HNICEM) · doi:10.1109/hnicem57413.2022.10109455
“In [1], the essential nature of environment perception is highlighted as simple grasping tasks are performed by a tetraplegic patient using an arm prosthetic.”
MethodBody-tool integration: past, present, and future
Miller, L. E., & Martel, M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99193-3.00010-6
Kudela, P., Fifer, M. S., Osborn, L. E., McMullen, D. P., Celnik, P. A., Cantarero, G. L., Tenore, F. V., & Anderson, W. S. (2023) · medRxiv · doi:10.1101/2023.06.22.23291761
Axonale Regeneration im zentralen Nervensystem
Klimaschewski, L. P. (2023) · Springer eBooks · doi:10.1007/978-3-662-66330-1_2
Chen, K., Forrest, A., González‐Burgos, G., & Kozai, T. D. Y. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.11.06.565852
Mamidanna, P. (2023) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau561808227
McNamara, I., Wellman, S. M., Li, L., Eles, J. R., Savya, S. P., Sohal, H. S., Angle, M. R., & Kozai, T. D. Y. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.11.22.568119
Designing Touch: Intracortical Neurohaptic Feedback in Virtual Reality
Paschall, C. J., Hauptman, J. S., Rao, R. P. N., Ojemann, J. G., & Herron, J. A. (2023) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-031-49457-4_10
BCI Controlled Robot for Drones
Priyan, M. S., Arunachalam, A. R., Dharneesh, S. K., et al. (2023) · International Conference on Smart Technologies, Communication and Robotics (STCR) · doi:10.1109/stcr59085.2023.10397026
“[11] Electroencephalography (EEG) emerges as a key technique, allowing the non-invasive measurement and recording of brain activity.”
BackgroundBülbül, D. K., & Güçlü, B. (2024) · Somatosensory & Motor Research · doi:10.1080/08990220.2024.2358522 · Cited by 2
Brain-Computer Interfaces in Robotic Arm for Motor Rehabilitation after Stroke
Le, Y. (2024) · MedScien · doi:10.61173/7ech1x24
Khunteta, R., Bhansali, S., Marshiana, D., et al. (2024) · International Conference on Science Technology Engineering and Mathematics (ICONSTEM) · doi:10.1109/iconstem60960.2024.10568860
3D directional tuning in the orofacial sensorimotor cortex during natural feeding and drinkingPreprint
Hosack, V. B., & Arce‐McShane, F. I. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.07.02.601741
Metadata
- Authors
- Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A.
- Affiliations
- University of Pittsburgh (US)
- Department of Neurosurgery, University of Texas at Austin, Austin, TX, USA.
- United States Department of Veterans Affairs (US)
- Corresponding author
- Flesher, Sharlene N.
- ORCID
- Venue
- Science
- Published
- 2021-05-21
- Volume
- 372
- Issue
- 6544
- Pages
- 831-836
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- PMC
- PMC8715714
- OpenAlex
- W3161143221
- Cited by
- 617
- References
- 40
- Citations by year
- 2026: 102 · 2025: 154 · 2024: 131 · 2023: 102 · 2022: 75 · 2021: 41
- FWCI
- 45.79
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- Science (publishedVersion)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Defense Advanced Research Projects Agency (N66001-16-C-4051, N66001-10-C-4056)
- National Science Foundation (DGE-1247842)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- brain-computer interface, tactile feedback, robotic arm control, tetraplegia, intracortical microstimulation, somatosensory cortex, motor cortex, upper limb prosthesis, grasping, bidirectional neural interface
- MeSH terms
- Adult, Arm, Artificial Limbs, Humans, Male, Motor Cortex, Movement, Quadriplegia, Robotics, Somatosensory Cortex, Touch, Hand Strength, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.