The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index; 5 of the 15 sources its claims cite were checked for support.
A brain-computer interface that evokes tactile sensations improves robotic arm control
Open accessPublished version of a preprint
Abstract
Prosthetic arms controlled by a brain-computer interface can enable people with tetraplegia to perform functional movements. However, vision provides limited feedback because information about grasping objects is best relayed through tactile feedback. We supplemented vision with tactile percepts evoked using a bidirectional brain-computer interface that records neural activity from the motor cortex and generates tactile sensations through intracortical microstimulation of the somatosensory cortex. This enabled a person with tetraplegia to substantially improve performance with a robotic limb; trial times on a clinical upper-limb assessment were reduced by half, from a median time of 20.9 to 10.2 seconds. Faster times were primarily due to less time spent attempting to grasp objects, revealing that mimicking known biological control principles results in task performance that is closer to able-bodied human abilities.
Overview
CoChat Summary
TL;DR
A bidirectional brain-computer interface that decoded motor intent and delivered intracortical microstimulation to somatosensory cortex improved a person with tetraplegia’s control of a robotic arm. Adding tactile feedback reduced median ARAT trial time from 20.9 to 10.2 s and improved median ARAT score from 17 to 21.
Key findings
- With ICMS-evoked tactile feedback, median ARAT score was 21 versus 17 without ICMS (p = 0.029, Wilcoxon rank-sum test), and higher than 23 prior sessions without ICMS (p = 0.005).
- Successful ARAT trial times decreased by 51.2%, from a median of 20.9 s to 10.2 s (p < 0.0001); grasp time decreased by 66%, from 13.3 s to 4.6 s, accounting for 88% of the total improvement.
- A score of 3, indicating object transfer in under 5 s, was achieved 15 times with tactile feedback versus once across all 108 trials without it; 14% of trials with tactile feedback were faster than the fastest trial without ICMS.
- In the object transfer task, time in the object zone decreased by 30.3%, from 3.3 ± 1.2 s to 2.3 ± 0.4 s per transfer (p = 0.002), and hand movement in the object zone decreased from 44.2 ± 13.1 to 32.4 ± 5.9 cm per transfer (p = 0.0007); total transfers increased from 315 without ICMS to 352 with ICMS, but transfers per trial did not significantly differ (15.8 ± 3.8 to 17.8 ± 2.4, p = 0.050).
Methods
- Single participant: a 28-year-old male with tetraplegia due to C5 motor/C6 sensory ASIA B spinal cord injury sustained 10 years before consent; study conducted under FDA Investigational Device Exemption and registered at ClinicalTrials.gov (NCT01894802).
- Two 88-electrode arrays were implanted in motor cortex hand/arm region to decode movement intent, and two 32-electrode arrays were implanted in area 1 of somatosensory cortex; a new 5 degree-of-freedom velocity decoder was trained daily, and ICMS was driven in real time by robotic hand sensors responding to object contact and grasp force.
- Performance was compared with and without ICMS on a modified ARAT with nine tasks, each object attempted three times per session and scored 0–3 with maximum score 27, using four sessions with ICMS and four without plus 23 prior sessions; an object transfer task was also performed in four sessions with and four without ICMS, five times per session, with Wilcoxon rank-sum and t-tests used for comparisons.
Limitations
- The paper states that this is a single-subject study and it is not guaranteed that findings will generalize to future experiments and participants.
- The paper states that future work should examine how stimulation encoding design, such as proportional versus on-off feedback, affects performance, and notes that many objects were rigid with no penalty for grasping too firmly, so fragile objects or more precise hand posture/grasp force control could depend more on specific sensory encoding schemes.
- Evident from the text: the participant had only one grasp dimension that opened and closed all fingers as a group, and some smaller objects were difficult to pick up because the fingertips often contacted objects rather than the distal phalanx pads, making grasp less stable; the increase in transfers per trial with ICMS was not statistically significant (p = 0.050).
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
3 Valid · 0 Not valid · 7 Not checked · 32 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“First, using the same fundamental neural decoding and control methods, two participants have achieved similar scores on functional tasks with vision alone (5, 6, 28).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Partly supportedcites [5] Wodlinger B, J. Neural Eng 12, 016011 (2015). 25514320 sourceExperimental — accuracy not yet measured
Section 3.4 reports similar functional-task scores under 7D and 10D control, but both scores are from the same participant. Section 2.2 identifies a single participant; this paper therefore does not establish the claim about two participants achieving similar scores with vision alone. Page numbers are unavailable in our copy. (LLM, conf=0.88)
- Partly supportedcites [6] Collinger JL, Lancet (London, England) 381, 557– 64 (2013). PMC3641862 23253623 sourceExperimental — accuracy not yet measured
The Methods (Observation-based calibration and neural decoding; Functional brain-control tasks) describe neural decoding and functional testing, and the Results (Clinical assessments) report an ARAT score of 15–17 for one participant. This paper does not establish that two participants achieved similar scores, and the retrieved passages do not explicitly say the tasks were performed with vision alone. (LLM, conf=0.84)
- Partly supportedcites [28] Downey JE, Sci. Rep 7, 16947 (2017). 29209023 PMC5717217 sourceExperimental — accuracy not yet measured
The Methods (Study participants; Neural recording and BCI decoder calibration, page unavailable) describe two participants using motor-cortex decoding to control a robotic arm; somatosensory arrays were not used in this experiment. The Results (Online population-level scaling improves BCI object grasping, page unavailable) report fairly close object-interaction success rates with scaling, but the more functional object-transport scores differ substantially: 1.09 versus 5.28 transfers per minute. Thus, the paper does not support a general claim that the participants achieved similar scores on functional tasks. (LLM, conf=0.86)
plainn = 2- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“In contrast, ICMS feedback in a relevant area of cortex, but in an unintuitive way, requires considerable learning time (thousands of trials) to use effectively (33).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Supportedcites [33] Dadarlat MC, O’Doherty JE, Sabes PN, Nat. Neurosci 18, 138– 44 (2015). 25420067 PMC4282864 source
The Results (Behavioral task and feedback signals) describe ICMS in somatosensory cortex, with electrode directions assigned independently of local neuronal responses. The Discussion (Learning to integrate a novel sensory signal) says the patterns did not mimic naturally occurring signals and had to be learned. Online Methods (Experimental Design) reports approximately 20,000 and 40,000 training trials before the two monkeys showed clear evidence of integrating ICMS with vision. (LLM, conf=0.94)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“it is only in recent studies of humans with chronically implanted microelectrode arrays that the perceptual characteristics of microstimulation have been elucidated (19, 20).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Not checked — no full text of the sourcecites [19] Flesher SN, Sci. Transl. Med 8, 361ra141 (2016). 27738096 source
- Supportedcites [20] Salas MA, Elife 7 (2018), doi: 10.7554/eLife.32904. source
The Abstract describes recent human ICMS studies and reports sensations elicited in a person with two implanted microelectrode arrays. Materials and methods (Task) describes how the participant reported each percept’s location, intensity, duration, and qualitative character; Results and discussion reports the resulting percept measurements. These passages support the claim that such human studies elucidated the perceptual characteristics of microstimulation. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Further, 14% of the trials with tactile feedback were completed more quickly than the very fastest trial without ICMS (Fig. 2C).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The time spent in the object zone (Fig. 1G) decreased by 30.3%, from 3.3 ± 1.2 s per transfer without ICMS to 2.3 ± 0.4 s per transfer with ICMS (p = 0.002, t-test, Fig. 3A).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
plainstates a causeSingle case ·- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
19 more claims
Create a free account to see all 42 claims and every source verdict.
- It may state two separate claims as one. 15
- Probably not a substantial claim. 3
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Generalized Inverses, Ridge Regression, Biased Linear Estimation, and Nonlinear Estimation
Marquardt, D. W. (1970) · Technometrics · doi:10.1080/00401706.1970.10488699 · Cited by 2,276
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Self-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Lyle, R. C. (1981) · International Journal of Rehabilitation Research · doi:10.1097/00004356-198112000-00001 · Cited by 1,326
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924
MANUAL MOTOR PERFORMANCE IN A DEAFFERENTED MAN
ROTHWELL, J. C., TRAUB, M. M., DAY, B. L., OBESO, J. A., THOMAS, P. K., & MARSDEN, C. D. (1982) · Brain · doi:10.1093/brain/105.3.515 · Cited by 862
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Self-citationA Standardized Approach to Performing the Action Research Arm Test
Yozbatiran, N., Der-Yeghiaian, L., & Cramer, S. C. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307305353 · Cited by 689
Active tactile exploration using a brain–machine–brain interface
O’Doherty, J. E., Lebedev, M. A., Ifft, P. J., Zhuang, K. Z., Shokur, S., Bleuler, H., & Nicolelis, M. A. L. (2011) · Nature · doi:10.1038/nature10489 · Cited by 629
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566
Wodlinger, B., Downey, J. E., Tyler-Kabara, E. C., Schwartz, A. B., Boninger, M. L., & Collinger, J. L. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016011 · Cited by 536
Self-citationConsumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
Control strategies in object manipulation tasks
Flanagan, J. R., Bowman, M. C., & Johansson, R. S. (2006) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2006.10.005 · Cited by 439
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Augurelle, A.-S., Smith, A. M., Lejeune, T., & Thonnard, J.-L. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00249.2002 · Cited by 330
Johansson, R. S., Riso, R., Häger, C., & Bäckström, L. (1992) · Experimental Brain Research · doi:10.1007/bf00229015 · Cited by 274
The Effects of Digital Anesthesia on Force Control Using a Precision Grip
Monzée, J., Lamarre, Y., & Smith, A. M. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00434.2001 · Cited by 266
Proprioceptive and cutaneous sensations in humans elicited by intracortical microstimulation
Armenta Salas, M., Bashford, L., Kellis, S., Jafari, M., Jo, H., Kramer, D., Shanfield, K., Pejsa, K., Lee, B., Liu, C. Y., et al. (2018) · eLife · doi:10.7554/elife.32904 · Cited by 263
The neural basis of perceived intensity in natural and artificial touch
Graczyk, E. L., Schiefer, M. A., Saal, H. P., Delhaye, B. P., Bensmaia, S. J., & Tyler, D. J. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf5187 · Cited by 258
Schiefer, M., Tan, D., Sidek, S. M., & Tyler, D. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016001 · Cited by 255
Functional priorities, assistive technology, and brain-computer interfaces after spinal cord injury
Collinger, J. L., Boninger, M. L., Bruns, T. M., Curley, K., Wang, W., & Weber, D. J. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.11.0213 · Cited by 248
Self-citationMaidenbaum, S., Abboud, S., & Amedi, A. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.11.007 · Cited by 230
Johansson, R. S., Häger, C., & Riso, R. (1992) · Experimental Brain Research · doi:10.1007/bf00229016 · Cited by 219
Wendelken, S., Page, D. M., Davis, T., Wark, H. A. C., Kluger, D. T., Duncan, C., Warren, D. J., Hutchinson, D. T., & Clark, G. A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0320-4 · Cited by 216
Graczyk, E. L., Resnik, L., Schiefer, M. A., Schmitt, M. S., & Tyler, D. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-26952-x · Cited by 216
Neural Basis of Touch and Proprioception in Primate Cortex
Delhaye, B. P., Long, K. H., & Bensmaia, S. J. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c170033 · Cited by 214
A learning-based approach to artificial sensory feedback leads to optimal integration
Dadarlat, M. C., O'Doherty, J. E., & Sabes, P. N. (2015) · Nature Neuroscience · doi:10.1038/nn.3883 · Cited by 210
Davidson, J. (2002) · Journal of Hand Therapy · doi:10.1016/s0894-1130(02)50011-9 · Cited by 206
Meredith, M. A., Wallace, M. T., & Stein, B. E. (1992) · Experimental Brain Research · doi:10.1007/bf02259139 · Cited by 163
Motor Cortical Representation of Position and Velocity During Reaching
Wang, W., Chan, S. S., Heldman, D. A., & Moran, D. W. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01180.2006 · Cited by 155
Jenmalm, P., Dahlstedt, S., & Johansson, R. S. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.6.2984 · Cited by 131
Morphology of neurons in the white matter of the adult human neocortex
Meyer, G., Wahle, P., Castañeyra-Perdomo, A., & Ferres-Torres, R. (1992) · Experimental Brain Research · doi:10.1007/bf02259143 · Cited by 128
Human perception of electrical stimulation on the surface of somatosensory cortex
Hiremath, S. V., Tyler-Kabara, E. C., Wheeler, J. J., Moran, D. W., Gaunt, R. A., Collinger, J. L., Foldes, S. T., Weber, D. J., Chen, W., Boninger, M. L., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0176020 · Cited by 122
Self-citationA cognitive neuroprosthetic that uses cortical stimulation for somatosensory feedback
Klaes, C., Shi, Y., Kellis, S., Minxha, J., Revechkis, B., & Andersen, R. A. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056024 · Cited by 118
Forearm amputees' views of prosthesis use and sensory feedback
Wijk, U., & Carlsson, I. (2015) · Journal of Hand Therapy · doi:10.1016/j.jht.2015.01.013 · Cited by 114
Ownership of an artificial limb induced by electrical brain stimulation
Collins, K. L., Guterstam, A., Cronin, J. A., Olson, J. D., Ehrsson, H. H., & Ojemann, J. G. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1616305114 · Cited by 98
Engineering Artificial Somatosensation Through Cortical Stimulation in Humans
Lee, B., Kramer, D. R., Salas, M. A., Kellis, S., Brown, D., Dobreva, T., Klaes, C., Heck, C., Liu, C. Y., & Andersen, R. A. (2018) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2018.00024 · Cited by 95
Bidirectional brain-computer interfaces
Hughes, C. L., Herrera, A. J., Gaunt, R. A., & Collinger, J. L. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00013-5 · Cited by 80
Self-citationBiomimetic Brain Machine Interfaces for the Control of Movement
Fagg, A. H., Hatsopoulos, N. G., de Lafuente, V., Moxon, K. A., Nemati, S., Rebesco, J. M., Romo, R., Solla, S. A., Reimer, J., Tkach, D. C., et al. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.3516-07.2007 · Cited by 75
Motor cortical activity changes during neuroprosthetic-controlled object interaction
Downey, J. E., Brane, L., Gaunt, R. A., Tyler-Kabara, E. C., Boninger, M. L., & Collinger, J. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-17222-3 · Cited by 63
Self-citationArtifact-free recordings in human bidirectional brain–computer interfaces
Weiss, J. M., Flesher, S. N., Franklin, R. K., Collinger, J. L., & Gaunt, R. A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae748 · Cited by 63
Self-citationThe role of visual deprivation and experience on the performance of sensory substitution devices
Stronks, H. C., Nau, A. C., Ibbotson, M. R., & Barnes, N. (2015) · Brain Research · doi:10.1016/j.brainres.2015.06.033 · Cited by 31
Sombeck, J. T., & Miller, L. E. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5cf3 · Cited by 24
Research works printed but not linked: 2
- J. M. Loomis R. L. Klatzky N. A. Giudice in Assistive Technology for Blindness and Low Vision R. Manduchi S. Kurniawan Eds. (CRC Press 2012).
- M. S. Johannes, J. D. Bigelow, J. M. Burck, S. D. Harshbarger, M. V. Kozlowski, T. Van Doren, An overview of the developmental process for the modular prosthetic limb. Johns Hopkins APL Tech. Dig. 30, 207–216 (2011).
Cited by
An Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206
Neuromorphic sensorimotor loop embodied by monolithically integrated, low-voltage, soft e-skin
Wang, W., Jiang, Y., Zhong, D., Zhang, Z., Choudhury, S., Lai, J.-C., Gong, H., Niu, S., Yan, X., Zheng, Y., et al. (2023) · Science · doi:10.1126/science.ade0086 · Cited by 788
Flexible brain–computer interfaces
Tang, X., Shen, H., Zhao, S., Li, N., & Liu, J. (2023) · Nature Electronics · doi:10.1038/s41928-022-00913-9 · Cited by 373
“Flexible BCIs create new opportunities for the integration of natural intelligence and artificial intelligence, with potential applications such as self-programmable and long-term stable real-time brain decoding with bio-inspired machine learning algorithms.”
BackgroundMethodRestoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
Recent advances in regenerative biomaterials
Cao, D., & Ding, J. (2022) · Regenerative Biomaterials · doi:10.1093/rb/rbac098 · Cited by 259
Metadata
- Authors
- Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A.
- Affiliations
- University of Pittsburgh (US)
- Department of Neurosurgery, University of Texas at Austin, Austin, TX, USA.
- United States Department of Veterans Affairs (US)
- Corresponding author
- Flesher, Sharlene N.
- ORCID
- Venue
- Science
- Published
- 2021-05-21
- Volume
- 372
- Issue
- 6544
- Pages
- 831-836
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- PMC
- PMC8715714
- OpenAlex
- W3161143221
- Cited by
- 617
- References
- 40
- Citations by year
- 2026: 102 · 2025: 154 · 2024: 131 · 2023: 102 · 2022: 75 · 2021: 41
- FWCI
- 45.79
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- Science (publishedVersion)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Defense Advanced Research Projects Agency (N66001-16-C-4051, N66001-10-C-4056)
- National Science Foundation (DGE-1247842)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- brain-computer interface, tactile feedback, robotic arm control, tetraplegia, intracortical microstimulation, somatosensory cortex, motor cortex, upper limb prosthesis, grasping, bidirectional neural interface
- MeSH terms
- Adult, Arm, Artificial Limbs, Humans, Male, Motor Cortex, Movement, Quadriplegia, Robotics, Somatosensory Cortex, Touch, Hand Strength, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.