A brain-computer interface that evokes tactile sensations improves robotic arm control
Open accessPublished version of a preprint
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index; 5 of the 15 sources its claims cite were checked for support.
Abstract
Prosthetic arms controlled by a brain-computer interface can enable people with tetraplegia to perform functional movements. However, vision provides limited feedback because information about grasping objects is best relayed through tactile feedback. We supplemented vision with tactile percepts evoked using a bidirectional brain-computer interface that records neural activity from the motor cortex and generates tactile sensations through intracortical microstimulation of the somatosensory cortex. This enabled a person with tetraplegia to substantially improve performance with a robotic limb; trial times on a clinical upper-limb assessment were reduced by half, from a median time of 20.9 to 10.2 seconds. Faster times were primarily due to less time spent attempting to grasp objects, revealing that mimicking known biological control principles results in task performance that is closer to able-bodied human abilities.
Overview
CoChat Summary
TL;DR
A bidirectional brain-computer interface that decoded motor intent and delivered intracortical microstimulation to somatosensory cortex improved a person with tetraplegia’s control of a robotic arm. Adding tactile feedback reduced median ARAT trial time from 20.9 to 10.2 s and improved median ARAT score from 17 to 21.
Key findings
- With ICMS-evoked tactile feedback, median ARAT score was 21 versus 17 without ICMS (p = 0.029, Wilcoxon rank-sum test), and higher than 23 prior sessions without ICMS (p = 0.005).
- Successful ARAT trial times decreased by 51.2%, from a median of 20.9 s to 10.2 s (p < 0.0001); grasp time decreased by 66%, from 13.3 s to 4.6 s, accounting for 88% of the total improvement.
- A score of 3, indicating object transfer in under 5 s, was achieved 15 times with tactile feedback versus once across all 108 trials without it; 14% of trials with tactile feedback were faster than the fastest trial without ICMS.
- In the object transfer task, time in the object zone decreased by 30.3%, from 3.3 ± 1.2 s to 2.3 ± 0.4 s per transfer (p = 0.002), and hand movement in the object zone decreased from 44.2 ± 13.1 to 32.4 ± 5.9 cm per transfer (p = 0.0007); total transfers increased from 315 without ICMS to 352 with ICMS, but transfers per trial did not significantly differ (15.8 ± 3.8 to 17.8 ± 2.4, p = 0.050).
Methods
- Single participant: a 28-year-old male with tetraplegia due to C5 motor/C6 sensory ASIA B spinal cord injury sustained 10 years before consent; study conducted under FDA Investigational Device Exemption and registered at ClinicalTrials.gov (NCT01894802).
- Two 88-electrode arrays were implanted in motor cortex hand/arm region to decode movement intent, and two 32-electrode arrays were implanted in area 1 of somatosensory cortex; a new 5 degree-of-freedom velocity decoder was trained daily, and ICMS was driven in real time by robotic hand sensors responding to object contact and grasp force.
- Performance was compared with and without ICMS on a modified ARAT with nine tasks, each object attempted three times per session and scored 0–3 with maximum score 27, using four sessions with ICMS and four without plus 23 prior sessions; an object transfer task was also performed in four sessions with and four without ICMS, five times per session, with Wilcoxon rank-sum and t-tests used for comparisons.
Limitations
- The paper states that this is a single-subject study and it is not guaranteed that findings will generalize to future experiments and participants.
- The paper states that future work should examine how stimulation encoding design, such as proportional versus on-off feedback, affects performance, and notes that many objects were rigid with no penalty for grasping too firmly, so fragile objects or more precise hand posture/grasp force control could depend more on specific sensory encoding schemes.
- Evident from the text: the participant had only one grasp dimension that opened and closed all fingers as a group, and some smaller objects were difficult to pick up because the fingertips often contacted objects rather than the distal phalanx pads, making grasp less stable; the increase in transfers per trial with ICMS was not statistically significant (p = 0.050).
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
3 Valid · 0 Not valid · 7 Not checked · 32 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“First, using the same fundamental neural decoding and control methods, two participants have achieved similar scores on functional tasks with vision alone (5, 6, 28).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Partly supportedcites [5] Wodlinger B, J. Neural Eng 12, 016011 (2015). 25514320 sourceExperimental — accuracy not yet measured
Section 3.4 reports similar functional-task scores under 7D and 10D control, but both scores are from the same participant. Section 2.2 identifies a single participant; this paper therefore does not establish the claim about two participants achieving similar scores with vision alone. Page numbers are unavailable in our copy. (LLM, conf=0.88)
- Partly supportedcites [6] Collinger JL, Lancet (London, England) 381, 557– 64 (2013). PMC3641862 23253623 sourceExperimental — accuracy not yet measured
The Methods (Observation-based calibration and neural decoding; Functional brain-control tasks) describe neural decoding and functional testing, and the Results (Clinical assessments) report an ARAT score of 15–17 for one participant. This paper does not establish that two participants achieved similar scores, and the retrieved passages do not explicitly say the tasks were performed with vision alone. (LLM, conf=0.84)
- Partly supportedcites [28] Downey JE, Sci. Rep 7, 16947 (2017). 29209023 PMC5717217 sourceExperimental — accuracy not yet measured
The Methods (Study participants; Neural recording and BCI decoder calibration, page unavailable) describe two participants using motor-cortex decoding to control a robotic arm; somatosensory arrays were not used in this experiment. The Results (Online population-level scaling improves BCI object grasping, page unavailable) report fairly close object-interaction success rates with scaling, but the more functional object-transport scores differ substantially: 1.09 versus 5.28 transfers per minute. Thus, the paper does not support a general claim that the participants achieved similar scores on functional tasks. (LLM, conf=0.86)
plainn = 2- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“In contrast, ICMS feedback in a relevant area of cortex, but in an unintuitive way, requires considerable learning time (thousands of trials) to use effectively (33).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Supportedcites [33] Dadarlat MC, O’Doherty JE, Sabes PN, Nat. Neurosci 18, 138– 44 (2015). 25420067 PMC4282864 source
The Results (Behavioral task and feedback signals) describe ICMS in somatosensory cortex, with electrode directions assigned independently of local neuronal responses. The Discussion (Learning to integrate a novel sensory signal) says the patterns did not mimic naturally occurring signals and had to be learned. Online Methods (Experimental Design) reports approximately 20,000 and 40,000 training trials before the two monkeys showed clear evidence of integrating ICMS with vision. (LLM, conf=0.94)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“it is only in recent studies of humans with chronically implanted microelectrode arrays that the perceptual characteristics of microstimulation have been elucidated (19, 20).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
What the sources say
- Not checked — no full text of the sourcecites [19] Flesher SN, Sci. Transl. Med 8, 361ra141 (2016). 27738096 source
- Supportedcites [20] Salas MA, Elife 7 (2018), doi: 10.7554/eLife.32904. source
The Abstract describes recent human ICMS studies and reports sensations elicited in a person with two implanted microelectrode arrays. Materials and methods (Task) describes how the participant reported each percept’s location, intensity, duration, and qualitative character; Results and discussion reports the resulting percept measurements. These passages support the claim that such human studies elucidated the perceptual characteristics of microstimulation. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Further, 14% of the trials with tactile feedback were completed more quickly than the very fastest trial without ICMS (Fig. 2C).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The time spent in the object zone (Fig. 1G) decreased by 30.3%, from 3.3 ± 1.2 s per transfer without ICMS to 2.3 ± 0.4 s per transfer with ICMS (p = 0.002, t-test, Fig. 3A).”
§ A brain-computer interface that evokes tactile sensations improves robotic arm control > Abstract
plainstates a causeSingle case ·- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
19 more claims
Create a free account to see all 42 claims and every source verdict.
- It may state two separate claims as one. 15
- Probably not a substantial claim. 3
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Generalized Inverses, Ridge Regression, Biased Linear Estimation, and Nonlinear Estimation
Marquardt, D. W. (1970) · Technometrics · doi:10.1080/00401706.1970.10488699 · Cited by 2,276
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Self-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Lyle, R. C. (1981) · International Journal of Rehabilitation Research · doi:10.1097/00004356-198112000-00001 · Cited by 1,326
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Research works printed but not linked: 2
- J. M. Loomis R. L. Klatzky N. A. Giudice in Assistive Technology for Blindness and Low Vision R. Manduchi S. Kurniawan Eds. (CRC Press 2012).
- M. S. Johannes, J. D. Bigelow, J. M. Burck, S. D. Harshbarger, M. V. Kozlowski, T. Van Doren, An overview of the developmental process for the modular prosthetic limb. Johns Hopkins APL Tech. Dig. 30, 207–216 (2011).
Cited by
Items 301–400 of 615
Brain-Computer Interface for Patients with Spinal Cord Injury: A Bibliometric Study
Feng, J., Gao, S., Hu, Y., Sun, G., & Sheng, W. (2024) · World Neurosurgery · doi:10.1016/j.wneu.2024.08.163 · Cited by 5
Park, S., Lipton, M. H., & Dadarlat, M. C. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad83c0 · Cited by 8
Chang, K., Wang, J., Wang, M., Wang, M., Duan, X., Peng, Z., Hsieh, D., & Li, L. (2024) · Applied Materials Today · doi:10.1016/j.apmt.2024.102510 · Cited by 6
Neural Correlation Integrated Adaptive Point Process Filtering on Population Spike Trains
Li, M., Chen, S., Zhang, X., & Wang, Y. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3545206 · Cited by 5
“For investigating the mapping from neural population activities to motion intents in brain, Brain-machine interface (BMI) offers an important platform [12], which aims at decoding the neural signals into digital commands to control a prosthetic device directly [13], [14].”
An assistive robot that enables people with amyotrophia to perform sequences of everyday activities
Hagengruber, A., Quere, G., Iskandar, M., Bustamante, S., Feng, J., Leidner, D. S., Albu‐Schäffer, A., Stulp, F., & Vogel, J. (2025) · Scientific Reports · doi:10.1038/s41598-025-89405-2 · Cited by 11
Contemporary implementations of spiking bio-inspired neural networks
Schegolev, A. E., Bastrakova, M. V., Sergeev, M. A., Maksimovskaya, A. A., Klenov, N. V., & Soloviev, I. I. (2024) · Mesoscience & nanotechnology · doi:10.64214/jmsn.01.01005 · Cited by 5
Veteran and Brain-Computer Interfaces: The Duty to Care
Guérin, V. (2025) · AJOB Neuroscience · doi:10.1080/21507740.2025.2530948 · Cited by 5
“…stimulation (TMS) for example, the soldier will soon be able to become one with a projected device, receiving tactile sensations from a robotic arm (Flesher et al. 2021) and perhaps one day visual, auditory, olfactory and even gustatory sensations via an avatar in a metaverse (Bernal et al. 2022).”
The impact of distractions on intracortical brain–computer interface control of a robotic arm
Guthrie, M. D., Herrera, A. J., Downey, J. E., Brane, L., Boninger, M. L., & Collinger, J. L. (2021) · Brain-Computer Interfaces · doi:10.1080/2326263x.2021.1980292 · Cited by 7
Self-citationBCI-Based Neuroprostheses and Physiotherapies for Stroke Motor Rehabilitation
Lim, J., Lin, D., Sohn, W. J., McCrimmon, C. M., Wang, P. T., Nenadić, Z., & Do, A. H. (2022) · Springer eBooks · doi:10.1007/978-3-031-08995-4_22 · Cited by 6
Lai, D., Wan, Z., Lin, J., Li, P., Ren, F., Zhu, J., Zhang, J., Wang, Y., Hao, Y., & Xu, K. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1133928 · Cited by 9
“, 2021), intra-cortical microstimulation (ICMS) with tactile feedback (Collinger et al., 2018; Flesher et al., 2021), and effective training methods like adding biased feedback (Mladenovic et al.”
BackgroundElectronic Neurons for a New Learning Paradigm
Wang, Z., Wang, J., Shi, X., Zhu, Z., Chen, P., & Peng, H. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202203247 · Cited by 5
Optimal control of a Wilson–Cowan model of neural population dynamics
Salfenmoser, L., & Obermayer, K. (2023) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/5.0144682 · Cited by 7
Bland, J. T., Davare, M., & Marneweck, M. (2023) · Journal of Neurophysiology · doi:10.1152/jn.00104.2023 · Cited by 5
“M1 readouts without sensory stimulation) (42).”
Augmented reality for constructivist learning at work: current perspectives and future applications
Bödding, R., Bentler, D., & Maier, G. W. (2023) · Gruppe Interaktion Organisation Zeitschrift für Angewandte Organisationspsychologie (GIO) · doi:10.1007/s11612-023-00699-0 · Cited by 13
“On other hand, the afferent delivery of sensations to the brain (e.g., Flesher et al. 2021), for instance the triggering of tactile perception of virtual objects directly in the brain, could provide new avenues for AR in the future.”
Conversion of a medical implant into a versatile computer-brain interface
Várkuti, B., Halász, L., Gooie, S. H., Miklós, G., Serena, R. S., van Elswijk, G., McIntyre, C. C., Lempka, S. F., Lozano, A. M., & Erőss, L. (2023) · Brain stimulation · doi:10.1016/j.brs.2023.12.011 · Cited by 5
“Invasive neural interfaces on the other hand, have so far mainly utilized intracranial targets [27,52 – 57], with the somatosensory cortex [27 – 29] and the sensory thalamus [45 – 47] as suggested targets for sensory neuroprosthetics.”
AI for brain-computer interfaces
Haslacher, D., Akmazoglu, T. B., van Beinum, A., Starke, G., Buthut, M., & Soekadar, S. R. (2024) · Developments in neuroethics and bioethics · doi:10.1016/bs.dnb.2024.02.003 · Cited by 11
Information Transmission through Biotic–Abiotic Interfaces to Restore or Enhance Human Function
Kelly, A. R., & Glover, D. J. (2024) · ACS Applied Bio Materials · doi:10.1021/acsabm.4c00435 · Cited by 5
Stretchable Capacitive Tactile Sensor Array for Accurate Distributed Pressure Recognition
Yu, J., Yao, S., Jiang, X., & Yao, Z. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3470250 · Cited by 5
Gielas, A. (2024) · Cambridge Quarterly of Healthcare Ethics · doi:10.1017/s096318012400063x · Cited by 5
An, Y., Mitchell, D., Lathrop, J., Flynn, D., & Chung, S. (2024) · IEEE Conference on Telepresence · doi:10.1109/telepresence63209.2024.10841769 · Cited by 8
“Brain Computer Interfaces (BCI) for robotic applications are an emerging technology gaining significant traction, unlocking new levels of control and enhancing human abilities [1], [2].”
Predicting proprioceptive cortical anatomy and neural coding with topographic autoencoders
Grogan, M., Blum, K. P., Wu, Y., Harston, J. A., Miller, L. E., & Faisal, A. A. (2024) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1012614 · Cited by 4
“Similarly, recent major developments in the control of limb movement through intracortical Brain Computer Interfaces are centred on restoring somatosensory sensory feed-back as well as effecting motion [5–8].”
Concealing–restoring system for physical layer data: Based on stochastic filtering theory
Fujii, T., & Hirokawa, M. (2022) · Physical Communication · doi:10.1016/j.phycom.2022.101602 · Cited by 7
Intracortical microstimulation in humans: a decade of safety and efficacyPreprint
Greenspon, C. M., Hobbs, T. G., Verbaarschot, C., Alamri, A. H., Shelchkova, N. D., Lienkämper, R., Ye, J., Simpson, T. W., Weiss, J. M., Weir, D. M., et al. (2025) · medRxiv · doi:10.1101/2025.08.11.25332271 · Cited by 5
“As part of this clinical trial, we have used ICMS for extensive psychophysical 5,23–26 and functional 27–30 testing across five participants.”
Self-citationHutchison, B. C., Bose, R., Spilker, B. J., Bhat, P., Memberg, W. D., Ketting-Olivier, A., Herring, E., Sweet, J. A., Miller, J. P., Kirsch, R. F., et al. (2025) · medRxiv · doi:10.1101/2025.08.20.25334094 · Cited by 5
“ICMS can be mapped to pressure sensors in real-time, improving the ability of SCI participants to grasp and transfer objects using robotic limbs 30 .”
Ikegaya, N., Mallela, A. N., Warnke, P. C., Kunigk, N. G., Liu, F., Schone, H. R., Verbaarschot, C., Hatsopoulos, N. G., Downey, J. E., Boninger, M. L., et al. (2024) · Journal of neurosurgery · doi:10.3171/2024.7.jns241296 · Cited by 9
Self-citationZhang, Q., Pang, Z., Lu, R., He, H., Ziemann, U., & Gao, Z. (2025) · Neural Plasticity · doi:10.1155/np/9100284 · Cited by 9
“A signi fi cant advancement in this fi eld is using bidirectional closed loop BCIs with sensory stimulation, which can provide direct tactile feedback to robotic arms, enabling paralyzed patients to perform tasks more naturally (Figure 4B) [51, 135].”
Anisotropic Tactile Sensors: Constructive Designs, Challenges, and Emerging Applications
Zhang, J., Zheng, K., Ma, J., Chen, M., Wang, X., Chang, F., Chen, S., Ai, B., & Cheng, Z. (2025) · Chem & Bio Engineering · doi:10.1021/cbe.5c00053 · Cited by 5
Chen, Z., Huang, X., Xia, N. L., Gu, M., Xu, J., Lu, M., Chen, H., Xiong, C., & Chen, Y. (2025) · Research · doi:10.34133/research.0942 · Cited by 4
Individualized brain-computer interface for people with disabilities: a review
Saha, S., Karlsson, P., Anderson, C. J., Kavehei, O., & McEwan, A. L. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2026.1738876 · Cited by 6
New Horizons in Human–Robot Interaction: Synergy, Cognition, and Emotion
Safavi, F., Pei, D., Olikkal, P., & Vinjamuri, R. K. (2024) · Springer eBooks · doi:10.1007/978-3-031-66656-8_5 · Cited by 5
Extending Tactile Space With Handheld Tools: A Re-Analysis and Review
Miller, L. E., & Farnè, A. (2024) · Multisensory Research · doi:10.1163/22134808-bja10134 · Cited by 6
Voxel-Level Brain States Prediction Using Swin Transformer
Sun, Y., Chahine, D., Wen, Q., Liu, T., Li, X., Yuan, Y., Calamante, F., & Lv, J. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3613793 · Cited by 10
“Furthermore,bylearningthehuman brainmechanism,brainstatespredictionhasthepotentialto beappliedtothebrain-computerinterface(BCI)[7]orassist theunderstandingoftheabnormalbraindynamicsofbrain disorders,e.g.,Schizophreniaanddementia.”
Geng, Y., Qin, L., Li, Y., Yu, Z., Li, L., Asogbon, M. G., Zhan, Y., Yan, N., Guo, X., & Li, G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7079 · Cited by 4
Intracortical brain-computer interfaces for improved motor function: a systematic review
Holt, M. W., Robinson, E. C., Shlobin, N. A., Hanson, J. T., & Bozkurt, İ. (2023) · Reviews in the Neurosciences · doi:10.1515/revneuro-2023-0077 · Cited by 6
Intelligent soft self-twisted shape sensor
Li, L., Xue, M., Xu, T., Liu, Y., Yuan, Y., & Zheng, L. (2023) · Physics Letters A · doi:10.1016/j.physleta.2023.129219 · Cited by 4
Entertainment robots based on swarm intelligence algorithm applied in remote dance performances
Chen, N. (2024) · Entertainment Computing · doi:10.1016/j.entcom.2024.100783 · Cited by 4
Neural Encoding of Direction and Distance across Reference Frames in Visually Guided Reaching
Cáceres, A., Barany, D. A., Dundon, N. M., Smith, J. C., & Marneweck, M. (2024) · eNeuro · doi:10.1523/eneuro.0405-24.2024 · Cited by 6
“Brain – computer interface technology decoding motor intention through neural activity for generating movement goals has advanced rapidly with the integration of sensory information (Flesher et al., 2021).”
Artificial Flexible Closed‐Loop Tactile Systems
Gu, J., Wang, H., Li, D., Zhang, X., Ji, X., & Liang, J. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202402052 · Cited by 5
Flexible Bi-directional Brain Computer Interface for Controlling Turning Behavior of Mice
Ye, Y., Tian, Y., Wang, H., Cheng, Q., Zhang, K., Wang, X., Zhou, C., Xu, C., Wei, X., Zhou, Z., et al. (2023) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems49605.2023.10052363 · Cited by 5
“Recently, people have paid more attention to neural modulation by applying certain stimuli to neurons for applications such as tactile perception and visual reconstruction [4, 5].”
BackgroundSeamless Robot Teleoperation: Intuitive Control through Hand Gestures and Neural Network Decoding
Fei, H., Lee, S., Wang, Z., Guo, L., Williams, D., Tedeschi, S., & Wang, X. (2024) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn60899.2024.10649908 · Cited by 5
“In contrast, devices that rely on human signals, such as gloves [13], inertia sensors [14]–[17], motion capture systems, brain-computer interfaces [18], [19], electromyographic signal devices, and virtual reality controllers [20], [21], facilitate the mapping of human intention to robot control,…”
BackgroundFarzan, F. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95730-4.00003-2 · Cited by 8
Robotic Arm for Biomedical Applications
Doss, A. S. A., Mishra, B., Mohammed, S., et al. (2021) · Springer eBooks · doi:10.1007/978-3-030-58675-1_38-1 · Cited by 4
On Accuracy of Restoration of Concealing-Restoring System for Physical Layer
Hirokawa, M. (2021) · International Conference on Electrical, Computer and Energy Technologies (ICECET) · doi:10.1109/icecet52533.2021.9698502 · Cited by 4
Ottenhoff, M. C., Verwoert, M., Goulis, S., Colon, A., Wagner, L., Tousseyn, S., van Dijk, J. P., Kubben, P., & Herff, C. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.07.04.498676 · Cited by 4
[The research status and development trends of brain-computer interfaces in medicine].
Chen, Q., Yuan, T., Zhang, L., Gong, J., Fu, L., Han, X., Ruan, M., & Yu, Z. (2023) · PubMed Central · doi:10.7507/1001-5515.202303038 · Cited by 4
Temmar, H., Willsey, M. S., Costello, J. T., Mender, M. J., Cubillos, L. H., Lam, J. L., Wallace, D. M., Kelberman, M. M., Patil, P. G., & Chestek, C. A. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.03.01.583000 · Cited by 5
TACTILE EDGES AND MOTION VIA PATTERNED MICROSTIMULATION OF THE HUMAN CORTEXPreprint
Valle, G., Alamari, A. H., Lienkämper, R., Downey, J. E., Sobinov, A. R., Endsley, L. J., Prasad, D., Boninger, M. L., Collinger, J. L., Warnke, P. C., et al. (2024) · medRxiv · doi:10.1101/2024.05.06.24306627 · Cited by 4
“We have shown previously that it is possible to map the sensors on bionic hands to somatotopically-matched electrodes in S1 to yield intuitive feedback about the locations of object contact, with normal force used to dictate ICMS intensity 2,16 .”
BackgroundSelf-citationRestoring Cortically Mediated Movement and Sensation in Complete TetraplegiaPreprint
Chandrasekaran, S., Wandelt, S. K., Jangam, A., et al. (2025) · medRxiv · doi:10.1101/2025.08.19.25330198 · Cited by 4
“Bidirectional iBCIs have made tremendous progress in decoding motor intent to control robotic or virtual arms and in restoring the sense of touch as these artificial arms interact with objects 6,14 .”
Howell, P., Rabe, F., Meneghin, C., Schading‐Sassenhausen, S., Schone, H. R., Sonar, H., Paik, J. K., Freund, P., Wenderoth, N., & Kikkert, S. (2026) · Journal of Neuroscience · doi:10.1523/jneurosci.0644-25.2026 · Cited by 6
Tactile exploration and imagery elicit distinct neural dynamics in the parietal cortical network
Zhang, Q., Yang, Y., Wang, Z., Zhou, J., Gao, R., Yang, X., Li, S., Yu, T., Zhou, J., & Wang, C. (2025) · Frontiers in Neuroscience · doi:10.3389/fnins.2025.1621383 · Cited by 5
Stretchable Curvature Sensors for Motion Capture with Bending‐Stretching Coupling Deformation
Wang, T., Xu, X., Li, S., Lan, Y., Chen, K., Li, W., Wang, G., Yu, K., Sun, L., & Su, Y. (2025) · Advanced Science · doi:10.1002/advs.202514779 · Cited by 8
Technologies in clinical neurophysiology for brain-body interfacing: IFCN handbook chapter
Cimolato, A., Sparapani, A., & Raspopović, S. (2026) · Clinical Neurophysiology · doi:10.1016/j.clinph.2026.2111913 · Cited by 3
Chen, J., Liu, Q., Tan, C., Yang, X., Zhao, Y., Hu, Q., Chen, G., & Lan, Y. (2024) · Brain Network and Modulation · doi:10.4103/bnm.bnm_15_24 · Cited by 5
Enhancing Meditation Techniques and Insights Using Feature Analysis of Electroencephalography (EEG)
Khadam, Z. M., Abdulhameed, A. A., & Hammad, A. (2024) · Al-Mustansiriyah Journal of Sciences · doi:10.23851/mjs.v35i1.1457 · Cited by 3
“Flesher [13], As a way to improve control over a robotic arm, it provides a novel BCI system that combines feedback from the skin.”
BackgroundYang, H., Li, T., Zhao, L., Wei, Y., Chen, X., Pan, J., & Fu, Y. (2025) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2025.1554266 · Cited by 4
Cai, Y., Liu, S., Wang, D., et al. (2025) · Actuators · doi:10.3390/act14060268 · Cited by 3
A Personalized and Adaptable User Interface for a Speech and Cursor Brain-Computer Interface
Peracha, H., Iacobacci, C., Singer-Clark, T., Hochberg, L. R., Stavisky, S. D., Brandman, D. M., & Card, N. S. (2026) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3772318.3790750 · Cited by 4
“…within the skull with much higher resolutions and signal-to-noise ratios, enabling control modalities such as cursor control [13, 16, 24, 52, 66, 75], robot arm control [29, 33], typing and handwriting interfaces [41, 61, 76], and more recently, speech decoding [20, 44, 46, 48, 62, 68, 73, 77].”
Lang, X., Feng, Z., Yang, X., & Xu, T. (2022) · Scientific Programming · doi:10.1155/2022/5460766 · Cited by 3
Robotic Arm for Biomedical Applications
Doss, A. S. A., Mishra, B., Mohammed, S., et al. (2022) · Springer eBooks · doi:10.1007/978-3-030-84205-5_38 · Cited by 3
Axonal Regeneration in the Central Nervous System
Klimaschewski, L. P. (2024) · Springer eBooks · doi:10.1007/978-3-662-68053-7_2 · Cited by 3
Restorative Treatments for Cervical Spinal Cord Injury, a Narrative Review
Kaleem, M. I., Javeed, S., Plog, B. A., Gupta, V. P., & Ray, W. Z. (2024) · Clinical Spine Surgery A Spine Publication · doi:10.1097/bsd.0000000000001699 · Cited by 3
“46,47 48 – 50 These types of neuroprosthetics, however, are challenged by the size and cost of the prosthetic sys-tem, dif fi culties in unique environments, and the long period of time required to learn a variety of tasks.”
Shu, Y., Yang, S., Li, P., Gou, S., Cheng, Y., Jia, Q., & Du, Z. J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1476447 · Cited by 4
Neuromodulation 3.0: brain-apparatus communication-based neuromodulation
Yao, D. (2024) · Brain-Apparatus Communication A Journal of Bacomics · doi:10.1080/27706710.2024.2432311 · Cited by 3
Skin‐Inspired in‐Sensor Encoding of Strain Vector Using Tunable Quantum Geometry
Liu, Z., Shi, J., Cao, J., Ma, Z., Yang, Z.-Z., Cui, Y., Wang, L., Dai, Y., Chen, M., Wang, P., et al. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202416204 · Cited by 6
How different immersive environments affect intracortical brain computer interfaces
Tortolani, A. F., Kunigk, N. G., Sobinov, A. R., Boninger, M. L., Bensmaïa, S. J., Collinger, J. L., Hatsopoulos, N. G., & Downey, J. E. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adb078 · Cited by 5
Self-citationBadi, M., Borgognon, S., O’Doherty, J. E., & Shokur, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00008-3 · Cited by 4
A Functional BCI Model by the P2731 working group: Physiology
Hossaini, A., Valeriani, D., Nam, C. S., Ferrante, R., & Mahmud, M. (2021) · Brain-Computer Interfaces · doi:10.1080/2326263x.2021.1968665 · Cited by 5
On Performance of Concealing-Restoring System for Analog Signals on Physical Layer
Fujii, T., & Hirokawa, M. (2022) · International Conference on Electrical, Computer and Energy Technologies (ICECET) · doi:10.1109/icecet55527.2022.9872933 · Cited by 3
(2023) · Nature Electronics · doi:10.1038/s41928-023-00938-8 · Cited by 3
Robots Used Today that we Did Not Expect 20 Years Ago (from the Editorial Board Members)
Gulrez, T. (2021) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-021-01438-7 · Cited by 3
Brain Computer Interface: Future, Challenges, and Potential ThreatsPreprint
Maiseli, B. J., Massawe, L. V., Mbise, M. E., Mkocha, K., Ally, N., Ismail, M., Michael, J., & Kimambo, S. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4073630 · Cited by 3
Verbaarschot, C., Karapetyan, V., Greenspon, C. M., et al. (2024) · medRxiv · doi:10.1101/2024.03.08.24303392 · Cited by 3
Self-citationNason, S. R., Deevi, P. I., Jude, J. J., Rabbani, Q., Jacques, B. G., Pritchard, A. L., Wimalasena, L. N., Richards, B. A., Karpowicz, B. M., Bechefsky, P. H., et al. (2026) · medRxiv · doi:10.64898/2026.02.19.26346583 · Cited by 8
A Low-Power Wireless 128-Channel Neural Interface Circuit for Multiregional Brain Recording
Song, Y., Liu, T., Sun, C., et al. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798169 · Cited by 2
“For instance, restoring dexterous movements, such as high degrees of freedom hand movements [1], or fine motor skills, such as handwriting [2] or speech capabilities [3]–[5] requires recording from hundreds of electrodes.”
Fan, G., Yin, M., Wang, Y., Yu, S., & Wang, X. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.107448 · Cited by 3
Neural Interfaces: Applications, Innovative Approaches, Biocompatibility, Biomimetics
Zemlyanskov, M. S., Arsentiev, K. A., Shtol, V. S., Konovalova, S. P., Grinevich, V. P., & Евгеньевич, М. П. (2025) · Journal of Evolutionary Biochemistry and Physiology · doi:10.1134/s0022093025040118 · Cited by 2
“Improvements in robotic arm control were managed to be achieved by adding an afferent tactile channel to the BCI [137]: a tetraplegic patient, whose somatosensory cortex was electrically stimulated to reproduce tactile sensations corre(cid:2) sponding to signals from sensors on the prosthesis,…”
Intracortical microstimulation induces rapid microglia process convergence
Williams, N. P., Kelly, A. M., Zheng, X. S., Vazquez, A. L., & Cui, X. T. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2025.123732 · Cited by 3
“The waveform and stimulation parameters tested in this study were chosen to align with clinically relevant ICMS used to evoke sensory percepts in somatosensory [4,51] and visual [5,8] cortex, specifically following parameters in Ref.”
Cortical somatosensory feedback for brain-controlled bionic hands
Valle, G. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00218-x · Cited by 3
“Multichannel ICMS has been shown to improve the intuitiveness and the richness bionic hand, somatosensory feedback based on ICMS has improved the ability to manipulate and interact with objects 7 .”
Forrest, A. M., Kunigk, N. G., Collinger, J. L., Gaunt, R. A., Chen, X., Geest, J. P. V., & Kozai, T. D. Y. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae1bda · Cited by 3
Self-citationA brain-computer interface roadmap for diagnosing and treating neurological disorders
Sun, G., Wang, Y., Liu, H., Weng, L., Li, X., He, W., Sun, J., Liang, S., Kong, W., Dong, J.-Z., et al. (2025) · The Innovation Informatics · doi:10.59717/j.xinn-inform.2025.100016 · Cited by 2
Stimulation Modalities in Wearable Haptic Systems: Single-Mode Feedback to Multiphysics Actuation
Guo, X. M., Avila, R. O., Wu, Z., Wang, X., Xu, P., Ju, P., Yang, Q., Liu, P., Choi, S., Nikitsin, A. V., et al. (2026) · Research · doi:10.34133/research.1192 · Cited by 4
“Advances in algorithms and data-driven control have further improved the accuracy and adaptability of haptic feedback, enabling more intelligent and responsive systems for next-generation interactive applications [ 27 – 30 ].”
Real-time brain-computer interface control of walking exoskeleton with bilateral sensory feedback
Lim, J., Wang, P. T., Sohn, W. J., Lin, D., Thaploo, S., Bashford, L., Bjånes, D. A., Nguyen, A., Gong, H., Armacost, M., et al. (2026) · Brain stimulation · doi:10.1016/j.brs.2026.103065 · Cited by 8
Zhang, Z., Li, B., Qiu, S., Bin, W. A. N. G., Wang, H., & Li, L. (2026) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-026-00521-2 · Cited by 4
Bridging cortical intentions: brain–computer interfaces for spinal cord injury recovery
Hu, X., He, J., Li, N., et al. (2026) · 中国科学通报:英文版 · doi:10.1016/j.scib.2026.03.016 · Cited by 2
Learning Human–Environment Interactions via Wearable AI Interfaces
Wen, F., Wang, S., & Zhang, T. (2026) · ACS Nano · doi:10.1021/acsnano.6c05494 · Cited by 3
Gilbert, F., Burkhart, I., & Morrill, J. (2026) · Neuroethics · doi:10.1007/s12152-026-09656-2 · Cited by 3
“Studies show that BCIs that evoke tactile sensations associated with intended actions can improve robotic-arm control [90, 91].”
Somatosensory Neuromodulation with a Focus Towards Clinical Systems
Graczyk, E. L., & Tyler, D. J. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_92-1 · Cited by 2
Madden, L. R., Graham, R. D., Lempka, S. F., & Bruns, T. M. (2024) · Journal of Neurophysiology · doi:10.1152/jn.00385.2023 · Cited by 2
A Sparsity-driven tinyML Accelerator for Decoding Hand Kinematics in Brain-Computer Interfaces
Krishna, A., Ramanathan, V., Yadav, S. S., et al. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10389094 · Cited by 2
“Invasive BCI systems, as depicted in Figure 1, offer superior spatiotemporal resolution by directly recording intracortical and cortical brain activities [3], [5] while also providing the capability for direct brain stimulation.”
BackgroundIn vivo recording of visually evoked potentials with novel full diamond ECoG implants
Wilfinger, F. C., Zhang, J. M., Nguyen, D., Dégardin, J., Bergonzo, P., Picaud, S. A., Borda, E., Ghezzi, D., Scorsone, E., Lissorgues, G., et al. (2024) · Diamond and Related Materials · doi:10.1016/j.diamond.2024.111335 · Cited by 3
van Dyck, L. E., Bremmer, F., & Dobs, K. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01870-9 · Cited by 2
Stepping up after spinal cord injury: negotiating an obstacle during walking
Frigon, A., & Lecomte, C. G. (2024) · Neural Regeneration Research · doi:10.4103/nrr.nrr-d-24-00369 · Cited by 2
Brain-Computer Interface Technologies, the Autistic Mirroring, and Twins’ Death: Autonomy and Ethos
de Araújo, A. F. M. (2024) · Journal of Technology in Behavioral Science · doi:10.1007/s41347-024-00446-2 · Cited by 3
“…grids inside the cortex, for instance — that uses algorithms to convert neuronal data into commands capable of controlling This manuscript has not been published elsewhere and it has not been submitted simultaneously for publication elsewhere. external software and hardware (Flesher et al., 2021).”
Bülbül, D. K., Walston, S. T., Duvan, F. T., Garrido, J. A., & Güçlü, B. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad9405 · Cited by 2
“…to those patients, which is also crucial for embodiment of the BCI device, reduced phantom limb pain for amputees, and cortical rehabilitation (Flesher et al 2016, Armenta Salas et al 2018, Flesher et al 2021, Gü ç lü 2021, Hughes et al 2021a, 2021b, Fifer et al 2022, Shelchkova et al 2023).”
Osborn, L. E., Christie, B. P., McMullen, D. P., Thomas, T. M., Thompson, M. C., Nickl, R. W., Pawar, A. S., Wester, B. A., Cantarero, G. L., Celnik, P. A., et al. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782061 · Cited by 3
“Intracortical microstimulation (ICMS) to the somatosensory cortex can create sensations of touch in humans [2]–[4], which can improve function during closed-loop control of an external robotic limb [5].”
Ruszala, B. M., & Schieber, M. H. (2025) · Cell Reports · doi:10.1016/j.celrep.2025.115664 · Cited by 1
How Does Artificial Intelligence Contribute to iEEG Research?
Berezutskaya, J., Saive, A.-L., Jerbi, K., & van Gerven, M. A. J. (2023) · Studies in neuroscience, psychology and behavioral economics · doi:10.1007/978-3-031-20910-9_47 · Cited by 5
Introduction of brain computer interface to neurologists
Kim, D.-H., Yeom, H. G., Kim, M., Kim, S. H., Yang, T., Kwon, O., & Kim, Y. (2021) · Annals of Clinical Neurophysiology · doi:10.14253/acn.2021.23.2.92 · Cited by 2
“Studies on transmitting sensory information to the brain through a robotic arm have also been conducted.(15) Two microelectrode arrays (with 88 channels) were inserted into the motor cortex hand and arm regions of patients with a cervical-spine cord injuries, and two microelectrode arrays (with 32 channels) were inser…”
MethodBrain-computer interface—Brain information reading and activity control
Xu, W., Chen, L., Sui, X., Yun, T., & Liu, Z. (2022) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/tb-2022-0338 · Cited by 4
Hand surgery in a new “hand-brain” era: change the hand, rebuild the brain
Feng, J., Gu, Y., & Xu, W. (2022) · 中国科学通报:英文版 · doi:10.1016/j.scib.2022.08.031 · Cited by 2
Metadata
- Authors
- Flesher, S. N., Downey, J. E., Weiss, J. M., Hughes, C. L., Herrera, A. J., Tyler-Kabara, E. C., Boninger, M. L., Collinger, J. L., & Gaunt, R. A.
- Affiliations
- University of Pittsburgh (US)
- Department of Neurosurgery, University of Texas at Austin, Austin, TX, USA.
- United States Department of Veterans Affairs (US)
- Corresponding author
- Flesher, Sharlene N.
- ORCID
- Venue
- Science
- Published
- 2021-05-21
- Volume
- 372
- Issue
- 6544
- Pages
- 831-836
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- PMC
- PMC8715714
- OpenAlex
- W3161143221
- Cited by
- 617
- References
- 40
- Citations by year
- 2026: 102 · 2025: 154 · 2024: 131 · 2023: 102 · 2022: 75 · 2021: 41
- FWCI
- 45.79
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- Science (publishedVersion)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Defense Advanced Research Projects Agency (N66001-16-C-4051, N66001-10-C-4056)
- National Science Foundation (DGE-1247842)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- brain-computer interface, tactile feedback, robotic arm control, tetraplegia, intracortical microstimulation, somatosensory cortex, motor cortex, upper limb prosthesis, grasping, bidirectional neural interface
- MeSH terms
- Adult, Arm, Artificial Limbs, Humans, Male, Motor Cortex, Movement, Quadriplegia, Robotics, Somatosensory Cortex, Touch, Hand Strength, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.