Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 961

The DOI matches its Crossref record; 113 of the 113 references it cites were found in a registry or an index.

Multiplex PCR: Optimization and Application in Diagnostic Virology

Open access
Elnifro, Elfath M., Ashshi, Ahmed M., Cooper, Robert J., Klapper, Paul E. · 2000 · Clinical Microbiology Reviews

Abstract

SUMMARY: PCR has revolutionized the field of infectious disease diagnosis. To overcome the inherent disadvantage of cost and to improve the diagnostic capacity of the test, multiplex PCR, a variant of the test in which more than one target sequence is amplified using more than one pair of primers, has been developed. Multiplex PCRs to detect viral, bacterial, and/or other infectious agents in one reaction tube have been described. Early studies highlighted the obstacles that can jeopardize the production of sensitive and specific multiplex assays, but more recent studies have provided systematic protocols and technical improvements for simple test design. The most useful of these are the empirical choice of oligonucleotide primers and the use of hot start-based PCR methodology. These advances along with others to enhance sensitivity and specificity and to facilitate automation have resulted in the appearance of numerous publications regarding the application of multiplex PCR in the diagnosis of infectious agents, especially those which target viral nucleic acids. This article reviews the principles, optimization, and application of multiplex PCR for the detection of viruses of clinical and epidemiological importance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/cmr.13.4.559

Cites

113 of 113 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 15

  1. Cassinotti P. Mietz H. Siegl G. Suitability and clinical application of a multiplex nested PCR assay for the diagnosis of herpes simplex virus infections. J. Med. Virol. 50 1996 75 81 · DOI
  2. Emmanuel P. J. Polymerase chain reaction from bench to bedside. Applications for infectious disease. J. Fla. Med. Assoc. 80 1993 627 630
  3. Harris E. Appropriate transfer of molecular technology. Asia Pacific Technol. Monitor 13 1996 29 33
  4. Hewlett I. K. Ruta M. Cristiano K. Hawthorne C. A. Epstein J. S. Co-amplification of multiple regions of the HIV-1 genome by the polymerase chain reaction: potential use in multiple diagnosis. Oncogene 4 1989 1149
  5. Hu K. O. Yu C. H. Lee S. Villamil F. G. Vierling J. M. Simultaneous detection of both hepatitis B virus DNA and hepatitis C virus RNA using a combined one-step polymerase chain reaction technique. Hepatology 21 1995 901 907
  6. Linz U. Delling U. Rübsamen-Waigmann H. Systematic studies on parameters influencing the performance of the polymerase chain reaction. J. Clin. Chem. Clin. Biochem. 28 1990 5 13
  7. Nicodème P. Steyaert J. Selecting optimal oligonucleotide primers for multiplex PCR. Intelligent Syst. Mol. Biol. 51 1997 210 213
  8. Pring-Akerblom P. Trijssenaar F. E. J. Adrian T. Hoyer H. Multiplex polymerase chain reaction for subgenus-specific detection of human adenovirus in clinical samples. J. Med. Virol. 58 1999 87 92 · doi:10.1002/(sici)1096-9071(199905)58:1<87::aid-jmv14>3.0.co;2-r
  9. Rajeev B. Biswas J. Molecular biologic techniques in ophthalmic pathology. Indian J. Ophthalmol. 46 1998 3 13
  10. Rochelle P. A. Leon R. D. Stewart M. H. Wolfe R. L. Comparison of primers and optimization of PCR conditions for detection of Cryptosporidium parvum and Giardia lamblia in water. J. Clin. Microbiol. 63 1997 106 114
  11. Ruano G. Brash D. E. Kidd K. K. PCR: the first few cycles. Amplifications 7 1991 1 4
  12. Sherlock J. Cirigliano V. Petrou M. Tutschek B. Adinolfi M. Assessment of diagnostic quantitative fluorescent multiplex polymerase chain reaction assays performed on single cells. Ann. Hum. Genet. 62 1998 9 23 · DOI
  13. 10.1002/(SICI)1098-2825(1996)10:6<312::AID-JCLA2>3.0.CO;2-8 · doi:10.1002/(sici)1098-2825(1996)10:6<312::aid-jcla2>3.0.co;2-8
  14. Williams J. F. Optimization strategies for the polymerase chain reaction. BioTechniques 7 1989 762 769
  15. Winn-Deen E. S. Automation of molecular genetic methods. Part 2: DNA amplification techniques. J. Clin. Ligand Assay 19 1996 21 26

Cited by

See all 961

Metadata

Authors
Elnifro, E. M., Ashshi, A. M., Cooper, R. J., & Klapper, P. E.
Venue
Clinical Microbiology Reviews
Published
2000-10
Volume
13
Issue
4
Pages
559-570
ISSN
  • 0893-8512 (ISSN-L)
  • 1098-6618
OpenAlex
W2137089963
Cited by
961
References
113
FWCI
2.48
Type
journal article
Language
en
Open access
green
Licence
journals.asm.org/non-commercial-tdm-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.