CoChat

Technical and clinical accuracy of three blood glucose meters: clinical impact assessment using error grid analysis and insulin sliding scales

Sutheran, Hannah Lise, Reynolds, Timothy · 2016 · Journal of Clinical Pathology
Cited by 10

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Aims: Manufacturers of point-of-care testing (POCT) glucose systems must adhere to International Organisation for Standardisation (ISO) 15197 performance standards, a tightened version of which becomes mandatory in May 2016. Using methods deviating from the evaluation requirements of ISO 15197, we investigated the accuracy and clinical utility of three glucose testing systems. Methods: Whole blood glucose was measured on 62 EDTA-preserved samples with each system followed by plasma glucose determination with a laboratory hexokinase method. Technical accuracy was assessed using linear regression, Bland-Altman plots and bias. Clinical utility was evaluated using consensus error grid analysis and insulin dosing algorithms. Results: The correlation coefficient of the glucose measuring devices with the comparator method was between 0.979 and 0.993 (n=61). Bias against the reference method was +0.7–+4.4%. The FreeStyle Lite (0.7±4.4%) and ACCU-CHEK Aviva (1.3±7.3%) systems had the least bias to the reference. Error grid analysis depicts all meters to be clinically accurate, with all results falling within Zones A and B. Conclusions: Conformité Européene-marked devices are presumed to have adequate accuracy, but postmarket evaluations are imperative to assess total system accuracy and whether regulatory targets are achieved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jclinpath-2015-203339

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Research works printed but not linked: 9

  1. 10.1016/j.clinthera.2005.10.010 · DOI
  2. Holko, 2011, Cost effectiveness and cost utility of the noncoding blood glucose meter CONTOUR®TS, Diabetes Metab Syndr Obes, 4, 79
  3. 10.1016/j.electacta.2009.09.019 · doi:10.1016/j.electacta.2009.09.019
  4. Hönes, 2008, The technology behind glucose meters: test strips, Diabetes Technol Ther, 10, S10, 10.1089/dia.2008.0005 · DOI · Paper page
  5. 10.17925/USE.2013.09.01.16 · DOI
  6. 10.1089/152091503322526969 · DOI · Paper page
  7. 10.1185/03007995.2012.673479 · DOI · Paper page
  8. 10.1089/dia.2011.0170 · DOI · Paper page
  9. Skeie, 2001, Patient-derived quality specifications for instruments used in self-monitoring of blood glucose, Clin Chem, 47, 67, 10.1093/clinchem/47.1.67 · DOI · Paper page

Cited by

Metadata

Authors
Sutheran, H. L., & Reynolds, T.
Venue
Journal of Clinical Pathology
Publisher
BMJ
Published
2016-02-05
Volume
69
Issue
10
Pages
899-905
ISSN
  • 0021-9746 (ISSN-L)
  • 1472-4146
OpenAlex
W2169676099
Cited by
10
References
10
FWCI
1.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.