CoChat

Reproducibility of near-infrared spectroscopy measurements of oxidative function and postexercise recovery kinetics in the medial gastrocnemius muscle

Southern, William M., Ryan, Terence E., Reynolds, Mary A., McCully, Kevin · 2014 · Applied Physiology, Nutrition, and Metabolism

The DOI matches its Crossref record; 49 of the 50 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to assess the reproducibility of resting blood flow, resting oxygen consumption, and mitochondrial capacity in skeletal muscle using near-infrared spectroscopy (NIRS). We also determined the influence of 2 exercise modalities (ergometer and rubber exercise bands) on the NIRS measurements. Fifteen young, healthy participants (5 female, 10 male) were tested on 2 nonconsecutive occasions within an 8-day period. The NIRS device was placed on the medial gastrocnemius. Venous and arterial occlusions were performed to obtain blood flow and oxygen consumption. A series of repeated arterial occlusions was used to measure the recovery kinetics of muscle oxygen consumption after ∼7-10 s of voluntary plantar flexion exercise. Resting blood flow had mean coefficients of variation (CV) of 42% and 38% for bands and ergometer, respectively, and resting metabolism had mean CVs of 17% and 12% for bands and ergometer, respectively. The recovery time constant of oxygen consumption (day 1 bands and ergometer: 23.2 ± 3.7 s, 27.6 ± 6.5 s, respectively; day 2 bands and ergometer: 25.5 ± 5.4 s, 25.0 ± 4.9 s, respectively) had mean CVs of 10% and 11% for bands and ergometer, respectively. We conclude that measurements of oxygen consumption and mitochondrial capacity using NIRS can be obtained with good reproducibility.

Overview

Integrity signals

Registry

Crossref · 10.1139/apnm-2013-0347

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 49 references

Research works printed but not linked: 3

  1. Altenkirch H.U., 1989, Normal values and reproducibility. Vasa, 18, 140
  2. Belardinelli R., 1998, G. Ital. Cardiol., 28, 866
  3. Van Beekvelt M.C.P., 2001, J. Appl. Physiol., 90, 511, 10.1152/jappl.2001.90.2.511 · DOI · Paper page

Cited by

Metadata

Authors
Southern, W. M., Ryan, T. E., Reynolds, M. A., & McCully, K.
Affiliations
University of Georgia (US)
Venue
Applied Physiology, Nutrition, and Metabolism
Published
2014-05
Volume
39
Issue
5
Pages
521-529
ISSN
  • 1715-5312 (ISSN-L)
  • 1715-5320
OpenAlex
W2156771361
Cited by
80
References
50
Citations by year
2026: 4 · 2025: 3 · 2024: 11 · 2023: 5 · 2022: 7 · 2021: 12 · 2020: 8 · 2019: 8 · 2018: 3 · 2017: 7 · 2016: 7 · 2015: 4 · 2014: 1
FWCI
9.49
Type
journal article
Language
en
Open access
closed
Licence
www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
Locations
  • Applied Physiology, Nutrition, and Metabolism (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (HD039676, R01HD039676)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
Keywords
near-infrared spectroscopy, measurement reproducibility, medial gastrocnemius, mitochondrial capacity, arterial occlusion, plantar flexion exercise, ergometer exercise, skeletal muscle metabolism
MeSH terms
Adult, Female, Humans, Kinetics, Male, Oxygen Consumption, Rest, Reproducibility of Results, Exercise, Muscle, Skeletal, Spectroscopy, Near-Infrared, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.