Reproducibility of near-infrared spectroscopy measurements of oxidative function and postexercise recovery kinetics in the medial gastrocnemius muscle
The DOI matches its Crossref record; 49 of the 50 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to assess the reproducibility of resting blood flow, resting oxygen consumption, and mitochondrial capacity in skeletal muscle using near-infrared spectroscopy (NIRS). We also determined the influence of 2 exercise modalities (ergometer and rubber exercise bands) on the NIRS measurements. Fifteen young, healthy participants (5 female, 10 male) were tested on 2 nonconsecutive occasions within an 8-day period. The NIRS device was placed on the medial gastrocnemius. Venous and arterial occlusions were performed to obtain blood flow and oxygen consumption. A series of repeated arterial occlusions was used to measure the recovery kinetics of muscle oxygen consumption after ∼7-10 s of voluntary plantar flexion exercise. Resting blood flow had mean coefficients of variation (CV) of 42% and 38% for bands and ergometer, respectively, and resting metabolism had mean CVs of 17% and 12% for bands and ergometer, respectively. The recovery time constant of oxygen consumption (day 1 bands and ergometer: 23.2 ± 3.7 s, 27.6 ± 6.5 s, respectively; day 2 bands and ergometer: 25.5 ± 5.4 s, 25.0 ± 4.9 s, respectively) had mean CVs of 10% and 11% for bands and ergometer, respectively. We conclude that measurements of oxygen consumption and mitochondrial capacity using NIRS can be obtained with good reproducibility.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although reproducibility of ventilatory thresholds [4] and lactate threshold [5] are known to be high, data on reproducibility of NIRS signals [5,20–22] and NIRS derived breakpoints [23] is limited.”
From Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold (2016) · cites this paper as [22]
Citations
Cites
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997 · cited 2×
“Attempts to quantify the relative changes in absorption and scattering of NIR light have some limitations because subcutaneous fat can influence the NIRS signals (Van Beekvelt et al. 2001b; Ferrari et al. 2004).”
BackgroundMethodCardiac output during submaximal and maximal work
Åstrand, P.-O., Cuddy, T. E., Saltin, B., & Stenberg, J. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.2.268 · Cited by 722 · cited 1×
“In this equation, BF is blood flow and [Hb] was assumed for both males and females to be 15 g/100 mL, which was based on average hemoglobin concentrations of healthy individuals reported previously (Åstrand et al. 1964; Wolfel et al. 1991).”
MethodValidation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600 · cited 3×
“Near-infrared spectroscopy (NIRS) is an evolving technology, which has shown to be increasingly useful in noninvasively exploring characteristics ofmuscle, brain, andother tissues (Hamaokaet al. 2007; Wolf et al. 2007).”
BackgroundInfluentialVan Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationNoninvasive measurement of forearm blood flow and oxygen consumption by near-infrared spectroscopy
De Blasi, R. A., Ferrari, M., Natali, A., Conti, G., Mega, A., & Gasparetto, A. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.3.1388 · Cited by 292
Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy
Hamaoka, T., Iwane, H., Shimomitsu, T., Katsumura, T., Murase, N., Nishio, S., Osada, T., Kurosawa, Y., & Chance, B. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.3.1410 · Cited by 280
Wilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256
Self-citationRyan, T. E., Erickson, M. L., Brizendine, J. T., Young, H.-J., & McCully, K. K. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00319.2012 · Cited by 233
Self-citationMcCully, K. K., Iotti, S., Kendrick, K., Wang, Z., Posner, J. D., Leigh, J., & Chance, B. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.1.5 · Cited by 228 · cited 2×
“The between subject variability reported in this study is similar to other studies that report resting mV̇O2 and mitochondrial capacity (McCully et al. 1994b; Larson-Meyer et al. 2000; Van Beekvelt et al. 2001b).”
ResultSelf-citationOxygen transport during steady-state submaximal exercise in chronic hypoxia
Wolfel, E. E., Groves, B. M., Brooks, G. A., Butterfield, G. E., Mazzeo, R. S., Moore, L. G., Sutton, J. R., Bender, P. R., Dahms, T. E., McCullough, R. E., et al. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.3.1129 · Cited by 219 · cited 1×
“In this equation, BF is blood flow and [Hb] was assumed for both males and females to be 15 g/100 mL, which was based on average hemoglobin concentrations of healthy individuals reported previously (Åstrand et al. 1964; Wolfel et al. 1991).”
MethodRyan, T. E., Southern, W. M., Reynolds, M. A., & McCully, K. K. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00835.2013 · Cited by 192
Self-citationEstimated contribution of hemoglobin and myoglobin to near infrared spectroscopy
Davis, M. L., & Barstow, T. J. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.01.012 · Cited by 169 · cited 1×
“(Davis and Barstow 2013).”
Boushel, R., Langberg, H., Olesen, J., Nowak, M., Simonsen, L., Bülow, J., & Kjær, M. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.5.1868 · Cited by 163 · cited 1×
“2007) and 133Xe washout (Boushel et al. 2000).”
Blasi, R. A. D., Palmisani, S., Alampi, D., Mercieri, M., Romano, R., Collini, S., & Pinto, G. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2822-y · Cited by 155
Measurement of hemoglobin flow and blood flow by near-infrared spectroscopy
Edwards, A. D., Richardson, C., van der Zee, P., Elwell, C., Wyatt, J. S., Cope, M., Delpy, D. T., & Reynolds, E. O. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.4.1884 · Cited by 153 · cited 1×
“1 mL/(min·100 mL)) agree with other studies (Edwards et al. 1993) that report NIRS blood flow values (mean = 1.”
ResultDynamic Knee-Extensor and Cycle Exercise: Functional MRI of Muscular Activity
Richardson, R., Frank, L., & Haseler, L. (1998) · International Journal of Sports Medicine · doi:10.1055/s-2007-971901 · Cited by 152 · cited 1×
“Previous studies of muscle metabolism have used a variety of exercise ergometers (Richardson et al. 1998; Cannon et al. 2013; Yoshida et al. 2013).”
BackgroundMcCully, K. K., Halber, C., & Posner, J. D. (1994) · Journal of Gerontology · doi:10.1093/geronj/49.3.b128 · Cited by 144 · cited 2×
“It is important to note that the variability and differences in initial mV̇O2 did not influence the recovery rate of mV̇O2, consistent with previous studies (Ryan et al. 2013a). In this study, resting oxygen consumption measured with NIRS had a CV of 12%–17%, which is in agreement with previous studies in our lab (16%…”
MethodResultSelf-citationSako, T., Hamaoka, T., Higuchi, H., Kurosawa, Y., & Katsumura, T. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.1.338 · Cited by 132
Material Properties of Thera-Band Tubing
Patterson, R. M., Stegink Jansen, C. W., Hogan, H. A., & Nassif, M. D. (2001) · Physical Therapy · doi:10.1093/ptj/81.8.1437 · Cited by 123 · cited 1×
“The material properties of the Thera-Band have been previously reported (Patterson et al. 2001).”
MethodPuente‐Maestu, L., Tena, T., Trascasa, C., Pérez-Parra, J., Mayoral, R. G., García, J. M., & Stringer, W. W. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0743-9 · Cited by 119
Kragelj, R., Jarm, T., Erjavec, T., Prešeren--Štrukelj, M., & Miklavčič, D. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1359451 · Cited by 117
How reproducible is bilateral forearm plethysmography?
Petrie, J. R., Ueda, S., Morris, A. D., Murray, L. S., Elliott, H. L., & Connell, J. M. C. (1998) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.1998.00656.x · Cited by 110
Kane, M. (1996) · Applied Measurement in Education · doi:10.1207/s15324818ame0904_4 · Cited by 106
van den Broek, N. M. A., De Feyter, H. M. M. L., Graaf, L. D., Nicolay, K., & Prompers, J. J. (2007) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00023.2007 · Cited by 91
Yoshida, T., & Watari, H. (1993) · European Journal of Applied Physiology · doi:10.1007/bf00634298 · Cited by 83 · cited 1×
“The time constants in the current study were also similar to previous studies measuring phosphocreatine recovery kinetics in the gastrocnemius muscle, using phosphorus magnetic resonance spectroscopy (Yoshida and Watari 1993; McCully et al. 1994b; Larson-Meyer et al. 2000; van den Broek et al. 2007).”
ResultSkeletal Muscle Metabolism in Endurance Athletes with Near-Infrared Spectroscopy
BRIZENDINE, J. T., RYAN, T. E., LARSON, R. D., & McCULLY, K. K. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827e0eb6 · Cited by 83 · cited 3×
“The recovery of mV̇O2 after a bout of exercise follows an exponential time course, such that the time constant can be used as an indicator of mitochondrial oxidative capacity (Motobe et al. 2004; Buchheit et al. 2011; Ryan et al. 2012; Brizendine et al. 2013).”
BackgroundResultSelf-citationThijssen, D. H. J., Bleeker, M. W. P., Smits, P., & Hopman, M. T. E. (2005) · Clinical Science · doi:10.1042/cs20040177 · Cited by 82 · cited 1×
“Furthermore, our values for resting blood flow agree with values reported in other studies using different techniques such as plethysmography (Altenkirch et al. 1989; Thijssen et al. 2005; Kooijman et al. 2007) and 133Xe washout (Boushel et al.”
ResultRyan, T. E., Brizendine, J. T., & McCully, K. K. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01043.2012 · Cited by 77 · cited 3×
“It is important to note that the variability and differences in initial mV̇O2 did not influence the recovery rate of mV̇O2, consistent with previous studies (Ryan et al. 2013a).”
BackgroundMethodResultInfluentialSelf-citationMotobe, M., Murase, N., Osada, T., Homma, T., Ueda, C., Nagasawa, T., Kitahara, A., Ichimura, S., Kurosawa, Y., Katsumura, T., et al. (2004) · Dynamic Medicine · doi:10.1186/1476-5918-3-2 · Cited by 72 · cited 2×
“The recovery of mV̇O2 after a bout of exercise follows an exponential time course, such that the time constant can be used as an indicator of mitochondrial oxidative capacity (Motobe et al. 2004; Buchheit et al. 2011; Ryan et al. 2012; Brizendine et al. 2013).”
BackgroundResultMcNeil, C. J., Murray, B. J., & Rice, C. L. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00921.2005 · Cited by 70
Buchheit, M., Ufland, P., Haydar, B., Laursen, P. B., & Ahmaidi, S. (2011) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2011.01020.x · Cited by 62 · cited 4×
“The recovery of mV̇O2 after a bout of exercise follows an exponential time course, such that the time constant can be used as an indicator of mitochondrial oxidative capacity (Motobe et al. 2004; Buchheit et al. 2011; Ryan et al. 2012; Brizendine et al. 2013).”
BackgroundResultInfluentialCelie, B., Boone, J., Van Coster, R., & Bourgois, J. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2183-x · Cited by 59
Cannon, D. T., Howe, F. A., Whipp, B. J., Ward, S. A., McIntyre, D. J., Ladroue, C., Griffiths, J. R., Kemp, G. J., & Rossiter, H. B. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00510.2013 · Cited by 56 · cited 1×
“Previous studies of muscle metabolism have used a variety of exercise ergometers (Richardson et al. 1998; Cannon et al. 2013; Yoshida et al. 2013).”
BackgroundMiura, H., McCully, K., Hong, L., Nioka, S., & Chance, B. (2001) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.51.599 · Cited by 54 · cited 1×
“The adipose tissue thickness influenced the range of the ischemic calibration as have been demonstrated in previous studies (Miura et al. 2001; Yang et al. 2005).”
ResultSelf-citationMalagoni, A. M., Felisatti, M., Mandini, S., Mascoli, F., Manfredini, R., Basaglia, N., Zamboni, P., & Manfredini, F. (2010) · Angiology · doi:10.1177/0003319710362975 · Cited by 52
Kinetics of estimated human muscle capillary blood flow during recovery from exercise
Ferreira, L. F., Harper, A. J., Townsend, D. K., Lutjemeier, B. J., & Barstow, T. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030189 · Cited by 50
Yang, Y., Soyemi, O. O., Landry, M. R., & Soller, B. R. (2005) · Optics Express · doi:10.1364/opex.13.001570 · Cited by 47
A novel method to measure regional muscle blood flow continuously using NIRS kinetics information
Nioka, S., Kime, R., Sunar, U., Im, J., İzzetoğlu, M., Zhang, J., Alacam, B., & Chance, B. (2006) · Dynamic Medicine · doi:10.1186/1476-5918-5-5 · Cited by 41 · cited 1×
“Various aspects of skeletal muscle physiology can be measured using NIRS, including skeletal muscle blood flow (De Blasi et al. 1994; Nioka et al. 2006), oxygenation during exercise (McNeil et al.”
BackgroundCrenshaw, A. G., Elçadi, G. H., Hellström, F., & Mathiassen, S. E. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2244-1 · Cited by 33
Reynolds, M. A., McCully, K. K., Burdett, B., Manella, C., Hawkins, L., & Backus, D. A. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.10.010 · Cited by 32
Self-citationCross, T. J., & Sabapathy, S. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12301 · Cited by 31
Altenkirch, H., Fransson, L., & Koch, G. (1989) · PubMed · Cited by 28
Phosphocreatine resynthesis during recovery in different muscles of the exercising leg by 31 P ‐ MRS
Yoshida, T., Abe, D., & Fukuoka, Y. (2013) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12081 · Cited by 22 · cited 1×
“Previous studies of muscle metabolism have used a variety of exercise ergometers (Richardson et al. 1998; Cannon et al. 2013; Yoshida et al. 2013).”
BackgroundLeg blood flow measurements using venous occlusion plethysmography during head-up tilt
Kooijman, M., Poelkens, F., Rongen, G. A. P. J. M., Smits, P., & Hopman, M. T. E. (2007) · Clinical Autonomic Research · doi:10.1007/s10286-007-0402-7 · Cited by 20
Belardinelli, R. (1998) · PubMed · Cited by 8
Larson-Meyer (2000) · doi:10.1002/(sici)1099-1492(200002)13:1<14::aid-nbm605>3.0.co;2-0 · cited 2×
“The between subject variability reported in this study is similar to other studies that report resting mV̇O2 and mitochondrial capacity (McCully et al. 1994b; Larson-Meyer et al. 2000; Van Beekvelt et al. 2001b).”
Result
Research works printed but not linked: 3
- Altenkirch H.U., 1989, Normal values and reproducibility. Vasa, 18, 140
- Belardinelli R., 1998, G. Ital. Cardiol., 28, 866
- Van Beekvelt M.C.P., 2001, J. Appl. Physiol., 90, 511, 10.1152/jappl.2001.90.2.511 · DOI · Paper page
Cited by
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
“In healthy subjects, the NIRS technology has shown good reproducibility whatever the type of exercise [51, 73].”
BackgroundJones, S., Chiesa, S. T., Chaturvedi, N., & Hughes, A. D. (2016) · Artery Research · doi:10.1016/j.artres.2016.09.001 · Cited by 184
“It is not feasible to perform repeated arterial occlusions to estimate _ VO2 throughout exercise, so a simple alternative is to surmise that immediately post-exercise the _ VO2 determined via arterial occlusion is equivalent to the _ VO2 during the final stages of the exercising protocol.(54) Recently, a model has bee…”
MethodMuscle Oximetry in Sports Science: An Updated Systematic Review
Perrey, S., Quaresima, V., & Ferrari, M. (2024) · Sports Medicine · doi:10.1007/s40279-023-01987-x · Cited by 100
Lucero, A. A., Addae, G., Lawrence, W., Neway, B., Credeur, D. P., Faulkner, J., ROWLANDS, D. S., & Stoner, L. R. (2017) · Experimental Physiology · doi:10.1113/ep086537 · Cited by 117
“Each occlusion was separated by 45 s of rest, with VO durations of 15 s and AO durations of 15 and 30 s (Southern et al. 2013).”
Method
Metadata
- Authors
- Southern, W. M., Ryan, T. E., Reynolds, M. A., & McCully, K.
- Affiliations
- University of Georgia (US)
- Venue
- Applied Physiology, Nutrition, and Metabolism
- Publisher
- Canadian Science Publishing
- Published
- 2014-05
- Volume
- 39
- Issue
- 5
- Pages
- 521-529
- ISSN
- 1715-5312 (ISSN-L)
- 1715-5320
- OpenAlex
- W2156771361
- Cited by
- 80
- References
- 50
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 11 · 2023: 5 · 2022: 7 · 2021: 12 · 2020: 8 · 2019: 8 · 2018: 3 · 2017: 7 · 2016: 7 · 2015: 4 · 2014: 1
- FWCI
- 9.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
- Locations
- Applied Physiology, Nutrition, and Metabolism (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (HD039676, R01HD039676)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- near-infrared spectroscopy, measurement reproducibility, medial gastrocnemius, mitochondrial capacity, arterial occlusion, plantar flexion exercise, ergometer exercise, skeletal muscle metabolism
- MeSH terms
- Adult, Female, Humans, Kinetics, Male, Oxygen Consumption, Rest, Reproducibility of Results, Exercise, Muscle, Skeletal, Spectroscopy, Near-Infrared, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.