QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
The DOI matches its Crossref record; 129 of the 129 references it cites were found in a registry or an index.
Abstract
▪ Abstract The interaction of light within tissue has been used to recognize disease since the mid-1800s. The recent developments of small light sources, detectors, and fiber optic probes provide opportunities to quantitatively measure these interactions, which yield information for diagnosis at the biochemical, structural, or (patho)physiological level within intact tissues. However, because of the strong scattering properties of tissues, the reemitted optical signal is often influenced by changes in biochemistry (as detected by these spectroscopic approaches) and by physiological and pathophysiological changes in tissue scattering. One challenge of biomedical optics is to uncouple the signals influenced by biochemistry, which themselves provide specificity for identifying diseased states, from those influenced by tissue scattering, which are typically unspecific to a pathology. In this review, we describe optical interactions pursued for biomedical applications (fluorescence, fluorescence lifetime, phosphorescence, and Raman from cells, cultures, and tissues) and then provide a descriptive framework for light interaction based upon tissue absorption and scattering properties. Finally, we review important endogenous and exogenous biological chromophores and describe current work to employ these signals for detection and diagnosis of disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Chandrasekhar, S. (1950) · CERN Document Server (European Organization for Nuclear Research) · Cited by 8,702
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
Absorption and Scattering of Light by Small Particles
Brown, R. G. W. (1984) · Optica Acta: International Journal of Optics · doi:10.1080/716099663 · Cited by 6,612
Light Scattering by Small Particles
Van de Hulst, H. C., & Twersky, V. (1957) · Physics Today · doi:10.1063/1.3060205 · Cited by 5,619
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
New Contributions to the Optics of Intensely Light-Scattering Materials Part I
Kubelka, P. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000448 · Cited by 2,681
Time-Correlated Single Photon Counting
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-524140-3.x5001-1 · Cited by 2,550
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909
Activatable Photosensitizers for Imaging and Therapy
Lovell, J. F., Liu, T. W. B., Chen, J., & Zheng, G. (2010) · Chemical Reviews · doi:10.1021/cr900236h · Cited by 1,717
Zipfel, W. R., Williams, R. M., Christie, R., Nikitin, A. Y., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832308100 · Cited by 1,676
Photosensitizers in clinical PDT
Allison, R. R., Downie, G. H., Cuenca, R., Hu, X.-H., Childs, C. J., & Sibata, C. H. (2004) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/s1572-1000(04)00007-9 · Cited by 1,059
In Vivo Fluorescence Spectroscopy and Imaging for Oncological Applications
Wagnieres, G. A., Star, W. M., & Wilson, B. C. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02521.x · Cited by 942
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Photophysics and photochemistry of photodynamic therapy: fundamental aspects
Plaetzer, K., Krammer, B., Berlanda, J., Berr, F., & Kiesslich, T. (2009) · Lasers in Medical Science · doi:10.1007/s10103-008-0539-1 · Cited by 891
Cell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
Zoumi, A., Yeh, A., & Tromberg, B. J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172368799 · Cited by 870
Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Tunable Localized Surface Plasmon Resonances in Tungsten Oxide Nanocrystals
Manthiram, K., & Alivisatos, A. P. (2012) · Journal of the American Chemical Society · doi:10.1021/ja211363w · Cited by 778
Tissue polarimetry: concepts, challenges, applications, and outlook
Ghosh, N. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3652896 · Cited by 740
Micro-Raman Spectroscopy Detects Individual Neoplastic and Normal Hematopoietic Cells
Chan, J. W., Taylor, D. S., Zwerdling, T., Lane, S. M., Ihara, K., & Huser, T. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.066761 · Cited by 679
Fluorescence Spectroscopy of Neoplastic and Non-Neoplastic Tissues
Ramanujam, N. (2000) · Neoplasia · doi:10.1038/sj.neo.7900077 · Cited by 654
Yaroslavsky, A. N., Schulze, P. C., Yaroslavsky, I. V., Schober, R., Ulrich, F., & Schwarzmaier, H.-J. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/305 · Cited by 651
Autofluorescence spectroscopy and imaging: a tool for biomedical research and diagnosis
Croce, A. C., & Bottiroli, G. (2014) · European Journal of Histochemistry · doi:10.4081/ejh.2014.2461 · Cited by 628
Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications
Leblond, F., Davis, S. C., Valdés, P. A., & Pogue, B. W. (2010) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2009.11.007 · Cited by 593
Fluorescence Spectroscopy In Vivo
Ramanujam, N. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0102 · Cited by 508
Laser and Non-laser Light Sources for Photodynamic Therapy
Brancaleon, L., & Moseley, H. (2002) · Lasers in Medical Science · doi:10.1007/s101030200027 · Cited by 483
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Self-citationNagaya, T., Nakamura, Y. A., Choyke, P. L., & Kobayashi, H. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00314 · Cited by 398
Autofluorescence of atmospheric bioaerosols – fluorescent biomolecules and potential interferences
Pöhlker, C., Huffman, J. A., & Pöschl, U. (2012) · Atmospheric Measurement Techniques · doi:10.5194/amt-5-37-2012 · Cited by 394
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2005) · Journal of the American Chemical Society · doi:10.1021/ja044421i · Cited by 392
Nicolas-Boluda, A., Vaquero, J., Vimeux, L., Guilbert, T., Barrin, S., Kantari-Mimoun, C., Ponzo, M., Renault, G., Deptula, P., Pogoda, K., et al. (2021) · eLife · doi:10.7554/elife.58688 · Cited by 368
Hawrysz, D. J., & Sevick-Muraca, E. M. (2000) · Neoplasia · doi:10.1038/sj.neo.7900118 · Cited by 340
Self-citationTranslation of Near-Infrared Fluorescence Imaging Technologies: Emerging Clinical Applications
Sevick-Muraca, E. M. (2012) · Annual Review of Medicine · doi:10.1146/annurev-med-070910-083323 · Cited by 339
Self-citationJanata, J., Josowicz, M., Vanýsek, P., & DeVaney, D. M. (1998) · Analytical Chemistry · doi:10.1021/a1980010w · Cited by 330
In vivo time-gated fluorescence imaging with biodegradable luminescent porous silicon nanoparticles
Gu, L., Hall, D. J., Qin, Z., Anglin, E., Joo, J., Mooney, D. J., Howell, S. B., & Sailor, M. J. (2013) · Nature Communications · doi:10.1038/ncomms3326 · Cited by 329
In Vivo Imaging of the Bronchial Wall Microstructure Using Fibered Confocal Fluorescence Microscopy
Thiberville, L., Moreno-Swirc, S., Vercauteren, T., Peltier, E., Cavé, C., & Bourg Heckly, G. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200605-684oc · Cited by 329
Valdés, P. A., Leblond, F., Kim, A., Harris, B. T., Wilson, B. C., Fan, X., Tosteson, T. D., Hartov, A., Ji, S., Erkmen, K., et al. (2011) · Journal of Neurosurgery · doi:10.3171/2011.2.jns101451 · Cited by 317
Optical Imaging Using Endogenous Contrast to Assess Metabolic State
Georgakoudi, I., & Quinn, K. P. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150108 · Cited by 316
Gerstbrein, B., Stamatas, G., Kollias, N., & Driscoll, M. (2005) · Aging Cell · doi:10.1111/j.1474-9726.2005.00153.x · Cited by 286
Stummer, W., Tonn, J.-C., Goetz, C., Ullrich, W., Stepp, H., Bink, A., Pietsch, T., & Pichlmeier, U. (2014) · Neurosurgery · doi:10.1227/neu.0000000000000267 · Cited by 277
Optical halide sensing using fluorescence quenching: theory, simulations and applications - a review
Geddes, C. D. (2001) · Measurement Science and Technology · doi:10.1088/0957-0233/12/9/201 · Cited by 271
Light scattering from cells: the contribution of the nucleus and the effects of proliferative status
Mourant, J. R., Canpolat, M., Brocker, C., Esponda-Ramos, O., Johnson, T. M., Matanock, A., Stetter, K., & Freyer, J. P. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429979 · Cited by 261
Fluorescence Lifetime Techniques in Medical Applications
Marcu, L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0495-y · Cited by 257
Müller, M. G., Georgakoudi, I., Zhang, Q., Wu, J., & Feld, M. S. (2001) · Applied Optics · doi:10.1364/ao.40.004633 · Cited by 256
Skin aging and natural photoprotection
Wulf, H. C., Sandby-Møller, J., Kobayasi, T., & Gniadecki, R. (2004) · Micron · doi:10.1016/j.micron.2003.11.005 · Cited by 233
Optical contrast agents and imaging systems for detection and diagnosis of cancer
Pierce, M. C., Javier, D. J., & Richards‐Kortum, R. (2008) · International Journal of Cancer · doi:10.1002/ijc.23858 · Cited by 204
“relevant component from the nonspecific background can be challenging, but fundamental experimental studies combined with numerical and analytical models have lead to notable successes for diagnostics in several clinical areas.(7,8) Despite these difficulties associated with using endogenous sources of optical”
BackgroundSelf-citationUthoff, R. D., Song, B., Sunny, S., Patrick, S., Suresh, A., Kolur, T., Keerthi, G., Spires, O., Anbarani, A., Wilder-Smith, P., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0207493 · Cited by 192
“Carcinogenesis affects cellular structure, breaking down the collagen and elastin cross-linking, leading to reduced fluorescence signal [29, 33, 35, 44].”
BackgroundReview of photodynamic therapy in actinic keratosis and basal cell carcinoma
Larko, O. (2008) · Therapeutics and Clinical Risk Management · doi:10.2147/tcrm.s1769 · Cited by 186
“But the absorption has a minimum in the wavelength region 600–1000 nm, ie, the “optical window” of tissue (Richards-Kortum and Sevick-Muraca 1996).”
Raman Spectroscopy and Fluorescence Photon Migration for Breast Cancer Diagnosis and Imaging
Manoharan, R., Shafer, K., Perelman, L., Wu, J., Chen, K., Deinum, G., Fitzmaurice, M., Myles, J., Crowe, J., Dasarl, R. R., et al. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb05160.x · Cited by 170
Paoli, J., Smedh, M., Wennberg, A.-M., & Ericson, M. B. (2008) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5701139 · Cited by 160
Valdes, P. A., Kim, A., Brantsch, M., Niu, C., Moses, Z. B., Tosteson, T. D., Wilson, B. C., Paulsen, K. D., Roberts, D. W., & Harris, B. T. (2011) · Neuro-Oncology · doi:10.1093/neuonc/nor086 · Cited by 159
Brustovetsky, T., Shalbuyeva, N., & Brustovetsky, N. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.091199 · Cited by 46
The role of tissue fluorescence in in vivo optical bioimaging
Lifante, J., Shen, Y., Ximendes, E., Martín Rodríguez, E., & Ortgies, D. H. (2020) · Journal of Applied Physics · doi:10.1063/5.0021854 · Cited by 43
Metadata
- Authors
- Richards-Kortum, R., & Sevick-Muraca, E.
- Venue
- Annual Review of Physical Chemistry
- Publisher
- Annual Reviews
- Published
- 1996-10
- Volume
- 47
- Issue
- 1
- Pages
- 555-606
- ISSN
- 0066-426X (ISSN-L)
- 1545-1593
- OpenAlex
- W2156099567
- Cited by
- 1,172
- References
- 129
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.