The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy
Open accessAbstract
PURPOSE: To prospectively compare an investigational version of a complex-based chemical shift-based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. MATERIALS AND METHODS: This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24-71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r(2)), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2 correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. RESULTS: Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction were used (r(2) = 0.99; slope ± standard deviation = 1.00 ± 0.01, P = .77; intercept ± standard deviation = 0.2% ± 0.1, P = .19). CONCLUSION: T1-independent chemical shift-based water-fat separation MR imaging methods can accurately quantify fat over the entire liver, by using MR spectroscopy as the reference standard, when T2 correction, spectral modeling of fat, and eddy current correction methods are used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of Overweight and Obesity in the United States, 1999-2004
Ogden, C. L., Carroll, M. D., Curtin, L. R., McDowell, M. A., Tabak, C. J., & Flegal, K. M. (2006) · JAMA · doi:10.1001/jama.295.13.1549 · Cited by 8,720
Prevalence of Hepatic Steatosis in An Urban Population in the United States: Impact of Ethnicity
Browning, J. D., Szczepaniak, L. S., Dobbins, R., Nuremberg, P., Horton, J. D., Cohen, J. C., Grundy, S. M., & Hobbs, H. H. (2004) · Hepatology · doi:10.1002/hep.20466 · Cited by 3,664
Nonalcoholic fatty liver disease: a spectrum of clinical and pathological severity.
MATTEONI, C., YOUNOSSI, Z., GRAMLICH, T., BOPARAI, N., LIU, Y., & MCCULLOUGH, A. (1999) · Gastroenterology · doi:10.1016/s0016-5085(99)70506-8 · Cited by 3,345
The Natural History of Nonalcoholic Fatty Liver Disease: A Population-Based Cohort Study
Adams, L. A., Lymp, J. F., St. Sauver, J., Sanderson, S. O., Lindor, K. D., Feldstein, A., & Angulo, P. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.04.014 · Cited by 2,890
Sampling Variability of Liver Biopsy in Nonalcoholic Fatty Liver Disease
Ratziu, V., Charlotte, F., Heurtier, A., Gombert, S., Giral, P., Bruckert, E., Grimaldi, A., Capron, F., & Poynard, T. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.03.084 · Cited by 2,106
Improved Method for Accurate and Efficient Quantification of MRS Data with Use of Prior Knowledge
Vanhamme, L., van den Boogaart, A., & Van Huffel, S. (1997) · Journal of Magnetic Resonance · doi:10.1006/jmre.1997.1244 · Cited by 1,627
Szczepaniak, L. S., Nurenberg, P., Leonard, D., Browning, J. D., Reingold, J. S., Grundy, S., Hobbs, H. H., & Dobbins, R. L. (2005) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00064.2004 · Cited by 1,562
Wood, J. C., Enriquez, C., Ghugre, N., Tyzka, J. M., Carson, S., Nelson, M. D., & Coates, T. D. (2005) · Blood · doi:10.1182/blood-2004-10-3982 · Cited by 1,045
Java-based graphical user interface for the MRUI quantitation package
Naressi, A., Couturier, C., Devos, J. M., Janssen, M., Mangeat, C., Beer, R. D., & Graveron-Demilly, D. (2001) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/bf02668096 · Cited by 1,003
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Self-citationYu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Self-citationMeasurement of intracellular triglyceride stores by H spectroscopy: validation in vivo
Szczepaniak, L. S., Babcock, E. E., Schick, F., Dobbins, R. L., Garg, A., Burns, D. K., McGarry, J. D., & Stein, D. T. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.5.e977 · Cited by 688
George, D. K., Goldwurm, S., Macdonald, G. A., Cowley, L. L., Walker, N. I., Ward, P. J., Jazwinska, E. C., & Powell, L. W. (1998) · Gastroenterology · doi:10.1016/s0016-5085(98)70482-2 · Cited by 659
Targher, G., Bertolini, L., Poli, F., Rodella, S., Scala, L., Tessari, R., Zenari, L., & Falezza, G. (2005) · Diabetes · doi:10.2337/diabetes.54.12.3541 · Cited by 574
Sanyal, A. J., Banas, C., Sargeant, C., Luketic, V. A., Sterling, R. K., Stravitz, R. T., Shiffman, M. L., Heuman, D., Coterrell, A., Fisher, R. A., et al. (2006) · Hepatology · doi:10.1002/hep.21103 · Cited by 522
Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21301 · Cited by 477
Self-citationMultiecho reconstruction for simultaneous water‐fat decomposition and T2* estimation
Yu, H., McKenzie, C. A., Shimakawa, A., Vu, A. T., Brau, A. C. S., Beatty, P. J., Pineda, A. R., Brittain, J. H., & Reeder, S. B. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21090 · Cited by 437
Self-citationAdams, L. A., Waters, O. R., Knuiman, M. W., Elliott, R. R., & Olynyk, J. K. (2009) · The American Journal of Gastroenterology · doi:10.1038/ajg.2009.67 · Cited by 413
Nonalcoholic Steatohepatitis in Children
Rashid, M., & Roberts, E. A. (2000) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1002/j.1536-4801.2000.tb02653.x · Cited by 411
Relaxation effects in the quantification of fat using gradient echo imaging
Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.08.012 · Cited by 394
Self-citationBonkovsky, H. L., Jawaid, Q., Tortorelli, K., LeClair, P., Cobb, J., Lambrecht, R. W., & Banner, B. F. (1999) · Journal of Hepatology · doi:10.1016/s0168-8278(99)80032-4 · Cited by 360
Water–fat separation with IDEAL gradient‐echo imaging
Reeder, S. B., McKenzie, C. A., Pineda, A. R., Yu, H., Shimakawa, A., Brau, A. C., Hargreaves, B. A., Gold, G. E., & Brittain, J. H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20831 · Cited by 357
Self-citationQuantification of liver fat using magnetic resonance spectroscopy
Thomsen, C., Becker, U., Winkler, K., Christoffersen, P., Jensen, M., & Henriksen, O. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92543-7 · Cited by 332
Yokoo, T., Bydder, M., Hamilton, G., Middleton, M. S., Gamst, A. C., Wolfson, T., Hassanein, T., Patton, H. M., Lavine, J. E., Schwimmer, J. B., et al. (2009) · Radiology · doi:10.1148/radiol.2511080666 · Cited by 303
Self-citationFat in the liver and insulin resistance
Yki‐Järvinen, H. (2005) · Annals of Medicine · doi:10.1080/07853890510037383 · Cited by 268
Non-invasive means of measuring hepatic fat content
Mehta, S. R., Thomas, E. L., Bell, J. D., Johnston, D. G., & Taylor-Robinson, S. D. (2008) · World Journal of Gastroenterology · doi:10.3748/wjg.14.3476 · Cited by 255
Quantification of hepatic steatosis with MRI: The effects of accurate fat spectral modeling
Reeder, S. B., Robson, P. M., Yu, H., Shimakawa, A., Hines, C. D., McKenzie, C. A., & Brittain, J. H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21751 · Cited by 248
Self-citationHines, C. D. G., Yu, H., Shimakawa, A., McKenzie, C. A., Brittain, J. H., & Reeder, S. B. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21957 · Cited by 221
Self-citationField map estimation with a region growing scheme for iterative 3‐point water‐fat decomposition
Yu, H., Reeder, S. B., Shimakawa, A., Brittain, J. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20654 · Cited by 217
Self-citationEffect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification
Hamilton, G., Middleton, M. S., Bydder, M., Yokoo, T., Schwimmer, J. B., Kono, Y., Patton, H. M., Lavine, J. E., & Sirlin, C. B. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21809 · Cited by 215
Self-citationKim, H., Taksali, S. E., Dufour, S., Befroy, D., Goodman, T. R., Petersen, K. F., Shulman, G. I., Caprio, S., & Constable, R. T. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21561 · Cited by 206
Brau, A. C. S., Beatty, P. J., Skare, S., & Bammer, R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21481 · Cited by 184
Johnson, N. A., Walton, D. W., Sachinwalla, T., Thompson, C. H., Smith, K., Ruell, P. A., Stannard, S. R., & George, J. (2008) · Hepatology · doi:10.1002/hep.22220 · Cited by 164
Machann, J., Thamer, C., Schnoedt, B., Stefan, N., Haring, H., Claussen, C. D., Fritsche, A., & Schick, F. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20825 · Cited by 162
Pineda, N., Sharma, P., Xu, Q., Hu, X., Vos, M., & Martin, D. R. (2009) · Radiology · doi:10.1148/radiol.2523082084 · Cited by 161
Histologic Variation of Grade and Stage of Non-alcoholic Fatty Liver Disease in Liver Biopsies
Janiec, D. J., Jacobson, E. R., Freeth, A., Spaulding, L., & Blaszyk, H. (2005) · Obesity Surgery · doi:10.1381/0960892053723268 · Cited by 131
Schwenzer, N. F., Machann, J., Haap, M. M., Martirosian, P., Schraml, C., Liebig, G., Stefan, N., Häring, H., Claussen, C. D., Fritsche, A., et al. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181862413 · Cited by 105
Fabbrini, E., DeHaseth, D., Deivanayagam, S., Mohammed, B. S., Vitola, B. E., & Klein, S. (2008) · Obesity · doi:10.1038/oby.2008.494 · Cited by 100
Optimal phased-array combination for spectroscopy
Bydder, M., Hamilton, G., Yokoo, T., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.050 · Cited by 92
Self-citationPathologic Assessment of Non-alcoholic Fatty Liver Disease
Bondini, S., Kleiner, D. E., Goodman, Z. D., Gramlich, T. L., & Younossi, Z. M. (2007) · Clinics in Liver Disease · doi:10.1016/j.cld.2007.02.002 · Cited by 83
Quantification of Hepatic Steatosis with 3-T MR Imaging: Validation inob/obMice
Hines, C. D. G., Yu, H., Shimakawa, A. S., McKenzie, C. A., WARNER, T. F. C. S., Brittain, J. H., & Reeder, S. B. (2009) · Radiology · doi:10.1148/radiol.09090131 · Cited by 83
Self-citationSchwimmer, J. B. (2007) · Seminars in Liver Disease · doi:10.1055/s-2007-985075 · Cited by 72
Rubinstein, E., Lavine, J., & Schwimmer, J. (2008) · Seminars in Liver Disease · doi:10.1055/s-0028-1091982 · Cited by 60
Irwan, R., Edens, M. A., & Sijens, P. E. (2007) · European Radiology · doi:10.1007/s00330-007-0801-0 · Cited by 49
Kawamitsu, H., Kaji, Y., Ohara, T., & Sugimura, K. (2003) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.2.47 · Cited by 35
Cited by
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Self-citationOmega-3 supplementation and non-alcoholic fatty liver disease: A systematic review and meta-analysis
Parker, H. M., Johnson, N. A., Burdon, C. A., Cohn, J. S., O’Connor, H. T., & George, J. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2011.08.018 · Cited by 569
Noninvasive, Quantitative Assessment of Liver Fat by MRI‐PDFF as an Endpoint in NASH Trials
Caussy, C., Reeder, S. B., Sirlin, C. B., & Loomba, R. (2018) · Hepatology · doi:10.1002/hep.29797 · Cited by 563
Self-citationNoureddin, M., Lam, J., Peterson, M. R., Middleton, M., Hamilton, G., Le, T.-A., Bettencourt, R., Changchien, C., Brenner, D. A., Sirlin, C., et al. (2013) · Hepatology · doi:10.1002/hep.26455 · Cited by 550
Self-citationTang, A., Tan, J., Sun, M., Hamilton, G., Bydder, M., Wolfson, T., Gamst, A. C., Middleton, M., Brunt, E. M., Loomba, R., et al. (2013) · Radiology · doi:10.1148/radiol.12120896 · Cited by 528
Self-citation
Metadata
- Authors
- Meisamy, S., Hines, C. D. G., Hamilton, G., Sirlin, C. B., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B.
- Venue
- Radiology
- Published
- 2011-03
- Volume
- 258
- Issue
- 3
- Pages
- 767-775
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2042640403
- Cited by
- 382
- References
- 45
- FWCI
- 24.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.