Vertebral bone mineral analysis: an integrated approach with CT.
The DOI matches its Crossref record.
Abstract
In the assessment of vertebral bone mineral density (BMD) with quantitative computed tomography, accuracy is limited by systematic errors caused by beam-hardening effects and unknown marrow and fat concentrations in trabecular bone. Reproducibility depends on precise repositioning of the patient, selection of the region of interest (ROI), and apparatus stability. In an integrated approach, these error sources were taken into account. Dual-energy methods are incorporated and tested to avoid systematic errors. Contour-detection algorithms for automated ROI determination that work reliably and offer improved reproducibility and efficiency are presented. A new design of reference phantom with solid tissue-equivalent materials provides calibration in BMD units and checks apparatus stability. Dual-energy methods are necessary to achieve accuracy of 5% or better. Automated ROI definition and reference phantom methods are mandatory for reproducibility of 2% or better.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Noninvasive assessment of bone mineral and structure: State of the art
Genant, H. K., Engelke, K., Fuerst, T., Glüer, C.-C., Grampp, S., Harris, S. T., Jergas, M., Lang, T., Lu, Y., Majumdar, S., et al. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110602 · Cited by 941
Kalender, W. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r03 · Cited by 689
Self-citationEngelke, K., Adams, J. E., Armbrecht, G., Augat, P., Bogado, C. E., Bouxsein, M. L., Felsenberg, D., Ito, M., Prevrhal, S., Hans, D. B., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.010 · Cited by 617
Quantitative computed tomography
Adams, J. E. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.04.074 · Cited by 458
Whitehead, H. M., Boreham, C., Mcllrath, E. M., Sheridan, B., Kennedy, L., Atkinson, A. B., & Madden, D. R. (1992) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1992.tb02901.x · Cited by 377
A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data
Kang, Y., Engelke, K., & Kalender, W. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.812265 · Cited by 287
Self-citationPache, G., Krauss, B., Strohm, P., Saueressig, U., Blanke, P., Bulla, S., Schäfer, O., Helwig, P., Kotter, E., Langer, M., et al. (2010) · Radiology · doi:10.1148/radiol.10091230 · Cited by 281
Birnbaum, B. A., Hindman, N., Lee, J., & Babb, J. S. (2007) · Radiology · doi:10.1148/radiol.2421052066 · Cited by 274
Kalender, W. A., Felsenberg, D., Genant, H. K., Fischer, M., Dequeker, J., & Reeve, J. (1995) · European Journal of Radiology · doi:10.1016/0720-048x(95)00631-y · Cited by 263
Self-citationKemmler, W., Lauber, D., Weineck, J., Hensen, J., Kalender, W., & Engelke, K. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.10.1084 · Cited by 246
“Bone mineral density (BMD) was measured by DXA and quantitative computed tomography (QCT) —DXA (QDR 4500A; Hologic Inc, Bedford, Mass) was performed at the lumbar spine (L1-L4), the proximal femur, and the forearm using standard protocols specified by the manufacturer; QCT (Somatom Plus 4; Siemens, Erlangen, Germany)…”
MethodSelf-citationMuller, R., Hildebrand, T., & Ruegsegger, P. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/1/009 · Cited by 245
Taguchi, A., Suei, Y., Ohtsuka, M., Otani, K., Tanimoto, K., & Ohtaki, M. (1996) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.25.5.9161180 · Cited by 227
Prevrhal, S., Engelke, K., & Kalender, W. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/3/017 · Cited by 226
Self-citationEffective dose values in bone mineral measurements by photon absorptiometry and computed tomography
Kalender, W. A. (1992) · Osteoporosis International · doi:10.1007/bf01623841 · Cited by 210
“In addition to the development of semi-automatic procedures for slice selection [7] and evaluation [8], which served to improve measurement precision decisively, dose reductions have been achieved [9,10].”
BackgroundSelf-citationPacke, G. E., Douglas, J. G., McDonald, A. F., Robins, S. P., & Reid, D. M. (1992) · Thorax · doi:10.1136/thx.47.6.414 · Cited by 167
Relationship Between Pulmonary Emphysema and Osteoporosis Assessed by CT in Patients With COPD
Ohara, T., Hirai, T., Muro, S., Haruna, A., Terada, K., Kinose, D., Marumo, S., Ogawa, E., Hoshino, Y., Niimi, A., et al. (2008) · Chest · doi:10.1378/chest.07-3054 · Cited by 162
Assessment of Vertebral Bone Mineral Density Using Volumetric Quantitative CT
Lang, T. F., Li, J., Harris, S. T., & Genant, H. K. (1999) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199901000-00027 · Cited by 162
Mastmeyer, A., Engelke, K., Fuchs, C., & Kalender, W. A. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.05.005 · Cited by 162
Self-citationEngelke, K., Kemmler, W., Lauber, D., Beeskow, C., Pintag, R., & Kalender, W. A. (2006) · Osteoporosis International · doi:10.1007/s00198-005-1938-9 · Cited by 148
“In addition, at the lumbar spine (L1–L3) quantitative computed tomography (QCT) was carried out (Somatom Plus 4, Siemens, Erlangen, Germany) using the Osteo protocol [11].”
MethodSelf-citationvan Hamersvelt, R. W., Schilham, A. M. R., Engelke, K., den Harder, A. M., de Keizer, B., Verhaar, H. J., Leiner, T., de Jong, P. A., & Willemink, M. J. (2017) · European Radiology · doi:10.1007/s00330-017-4801-4 · Cited by 94
Metadata
- Authors
- Kalender, W. A., Klotz, E., & Suess, C.
- Venue
- Radiology
- Published
- 1987-08
- Volume
- 164
- Issue
- 2
- Pages
- 419-423
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2116114647
- Cited by
- 204
- References
- 0
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.