Laminar Variation in Threshold for Detection of Electrical Excitation of Striate Cortex by Macaques
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Macaques were trained to signal their detection of electrical stimulation applied by a movable microelectrode to perifoveal striate cortex. Trains of ≤100 cathodal, 0.2-ms, constant current pulses were delivered at 50 or 100 Hz. The minimum current that could be reliably detected was measured at successive depths along radial electrode penetrations through the cortex. The lowest detection thresholds were routinely encountered when the stimulation was applied to layer 3, particularly just at the juncture between layers 3 and 4A. On the average, there was a twofold variation in threshold along the penetrations, with the highest intracortical thresholds being in layers 4C and 6. Variations as high as 20-fold were obtained in some individual penetrations, whereas relatively little change was observed in others. The minimum detectable current was 1 μA at a site in layer 3, i.e., 10–100 times lower than that for surface stimulation. Because macaques, as do human subjects, find electrical stimulation of striate cortex to be highly similar at all loci (a phosphene in the human case), it is puzzling as to how such uniformity of effect evolves from the exceedingly intricate circuitry available to the effective stimuli. It is hypothesized that the stimulus captures the most excitable elements, which then suppress other functional moieties, producing only the luminance of the phosphene. Lowest thresholds presumably are encountered when the electrode lies among these excitable elements that can, with higher currents, be stimulated directly from some distance or indirectly by the horizontal bands of myelinated axons, the stria of Baillarger.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dacey, D. M., Liao, H.-W., Peterson, B. B., Robinson, F. R., Smith, V. C., Pokorny, J., Yau, K.-W., & Gamlin, P. D. (2005) · Nature · doi:10.1038/nature03387 · Cited by 1,333
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 1×
“…light—a phosphene—that usually is qualitatively invariant despite wide adjustments in the parameters and locus of stimulation (Bak et al. 1990; Brindley 1971; Brindley and Lewin 1968; Dobelle and Mladejovsky 1974; Henderson et al. 1979; Pollen 1975; Rushton and Brindley 1978; Schmidt et al. 1996).”
BackgroundVisual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 1×
“Yet they have an exceedingly wide distribution of dendrites and, given that the geniculate input to striate cortex is a mere 6–8% (Kara and Reid 2003; Latawiec et al. 2000; Peters et al. 1994), to provide the full gamut of visual experience, the giant RGCs might well feed a cortical photergic…”
BackgroundSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672 · cited 4×
“Schmidt et al. (1996) in humans, Bartlett and Doty (1980), Tehovnik et al. (2005), and the present study all found thresholds of 2 A or lower with microelectrodes in striate cortex; yet most thresholds are considerably above this (Figs.”
BackgroundInfluentialDobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Visual sensations produced by intracortical microstimulation of the human occipital cortex
Bak, M., Girvin, J. P., Hambrecht, F. T., Kufta, C. V., Loeb, G. E., & Schmidt, E. M. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442682 · Cited by 299 · cited 3×
“Laminar Variation in Threshold for Detection of Electrical Excitation of Striate Cortex by Macaques”
BackgroundGrüsser, O.-J., & Hagner, M. (1990) · Documenta Ophthalmologica · doi:10.1007/bf00165665 · Cited by 77
Cited by
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Direct and Indirect Activation of Cortical Neurons by Electrical Microstimulation
Tehovnik, E. J., Tolias, A. S., Sultan, F., Slocum, W. M., & Logothetis, N. K. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00126.2006 · Cited by 357
Shape perception via a high-channel-count neuroprosthesis in monkey visual cortex
Chen, X., Wang, F., Fernandez, E., & Roelfsema, P. R. (2020) · Science · doi:10.1126/science.abd7435 · Cited by 250
Lewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
Klink, P. C., Dagnino, B., Gariel-Mathis, M.-A., & Roelfsema, P. R. (2017) · Neuron · doi:10.1016/j.neuron.2017.05.033 · Cited by 135
“…previous results indicate that the precise positioning of the electrode arrayswithin this cortical depth range has relatively little influence on the qualitative effect of microstimulation (DeYoe et al., 2005; Murphey and Maunsell, 2007; Tehovnik and Slocum, 2009; Tehovnik et al., 2002).”
ResultImplantable microcoils for intracortical magnetic stimulation
Lee, S. W., Fallegger, F., Casse, B. D. F., & Fried, S. I. (2016) · Science Advances · doi:10.1126/sciadv.1600889 · Cited by 151
Behavioral detection of electrical microstimulation in different cortical visual areas
Murphey, D. K., & Maunsell, J. H. R. (2007) · Current Biology · doi:10.1016/j.cub.2007.03.066 · Cited by 111
Torab, K., Davis, T. S., Warren, D. J., House, P. A., Normann, R. A., & Greger, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035001 · Cited by 90
Phosphene induction by microstimulation of macaque V1
Tehovnik, E. J., & Slocum, W. M. (2007) · Brain Research Reviews · doi:10.1016/j.brainresrev.2006.11.001 · Cited by 83
Saturation in phosphene size with increasing current levels delivered to human visual cortex
Bosking, W. H., Sun, P., Ozker, M., Pei, X., Foster, B. L., Beauchamp, M. S., & Yoshor, D. (2017) · The Journal of Neuroscience · doi:10.1523/jneurosci.2896-16.2017 · Cited by 75
Microstimulation of visual cortex to restore vision
Tehovnik, E. J., Slocum, W. M., Smirnakis, S. M., & Tolias, A. S. (2009) · Progress in Brain Research · doi:10.1016/s0079-6123(09)17524-6 · Cited by 71
“This uniformity of perception is believed to arise from activation of common V1 elements no matter where one stimulates in the V1 map (Bartlett et al., 2005; DeYoe et al., 2005).”
BackgroundMethodResultInfluentialCortical visual prostheses: From microstimulation to functional percept
Najarpour Foroushani, A., Pack, C. C., & Sawan, M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa904 · Cited by 62
Paraskevoudi, N., & Pezaris, J. S. (2019) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2018.00073 · Cited by 39
Electrical induction of vision
Tehovnik, E. J., & Slocum, W. M. (2013) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.03.012 · Cited by 33
The functional differentiation of brain–computer interfaces (BCIs) and its ethical implications
Sun, X.-Y., & Ye, B. (2023) · Humanities and Social Sciences Communications · doi:10.1057/s41599-023-02419-x · Cited by 29
Approaches to a cortical vision prosthesis: implications of electrode size and placement
Christie, B. P., Ashmont, K. R., House, P. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/025003 · Cited by 26
“Fibers in layer 1 may make this more difficult, but microelectrodes acutely placed in layers 2/3 can evoke phosphenes with safe low levels of stimulation [20, 21].”
BackgroundNeurophysiological considerations for visual implants
Meikle, S. J., & Wong, Y. T. (2022) · Brain Structure and Function · doi:10.1007/s00429-021-02417-2 · Cited by 15
“If an electrode is positioned within layer III/layer IV of V1, the detection thresholds are lower and neural activity is more readily evoked across the canonical circuit (Allison-Walker et al. 2021; DeYoe et al. 2005).”
BackgroundInfluentialSomatosensation Evoked by Cortical Surface Stimulation of the Human Primary Somatosensory Cortex
Kirin, S. C., Yanagisawa, T., Oshino, S., Edakawa, K., Tanaka, M., Kishima, H., & Nishimura, Y. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01019 · Cited by 12
Metadata
- Authors
- DeYoe, E. A., Lewine, J. D., & Doty, R. W.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2005-11
- Volume
- 94
- Issue
- 5
- Pages
- 3443-3450
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2147812701
- Cited by
- 86
- References
- 7
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.