The DOI matches its Crossref record.
Interstitial-lymphatic mechanisms in the control of extracellular fluid volume
Abstract
While the study of the physiochemical composition and structure of the interstitium on a molecular level is a large and important field in itself, the present review centered mainly on the functional consequences for the control of extracellular fluid volume. As pointed out in section I, a biological monitoring system for the total extracellular volume seems very unlikely because a major part of that volume is made up of multiple, separate, and functionally heterogeneous interstitial compartments. Even less likely is a selective volume control of each of these compartments by the nervous system. Instead, as shown by many studies cited in this review, a local autoregulation of interstitial volume is provided by automatic adjustment of the transcapillary Starling forces and lymph flow. Local vascular control of capillary pressure and surface area, of special importance in orthostasis, has been discussed in several recent reviews and was mentioned only briefly in this article. The gel-like consistency of the interstitium is attributed to glycosaminoglycans, in soft connective tissues mainly hyaluronan. However, the concept of a gel phase and a free fluid phase now seems to be replaced by the quantitatively more well-defined distribution spaces for glycosaminoglycans and plasma protein, apparently in osmotic equilibrium with each other. The protein-excluded space, determined mainly by the content of glycosaminoglycans and collagen, has been measured in vivo in many tissues, and the effect of exclusion on the oncotic buffering has been clarified. The effect of protein charge on its excluded volume and on interstitial hydraulic conductivity has been studied only in lungs and is only partly clarified. Of unknown functional importance is also the recent finding of a free interstitial hyaluronan pool with relatively rapid removal by lymph. The postulated preferential channels from capillaries to lymphatics have received little direct support. Thus the variation of plasma-to-lymph passage times for proteins may probably be ascribed to heterogeneity with respect to path length, linear velocity, and distribution volumes. Techniques for measuring interstitial fluid pressure have been refined and reevaluated, approaching some concensus on slightly negative control pressures in soft connective tissues (0 to -4 mmHg), zero, or slightly positive pressure in other tissues. Interstitial pressure-volume curves have been recorded in several tissues, and progress has been made in clarifying the dependency of interstitial compliance on glycosaminoglycan-osmotic pressure, collagen, and microfibrils.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Iliff, J. J., Wang, M., Liao, Y., Plogg, B. A., Peng, W., Gundersen, G. A., Benveniste, H., Vates, G. E., Deane, R., Goldman, S. A., et al. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003748 · Cited by 5,824
“The lymphatic vasculature represents a second circulation, parallel to the blood vasculature, that accounts for the clearance of interstitial fluid (ISF) with its constituent proteins and other solutes not absorbed across postcapillary venules (1, 2).”
BackgroundSleep Drives Metabolite Clearance from the Adult Brain
Xie, L., Kang, H., Xu, Q., Chen, M. J., Liao, Y., Thiyagarajan, M., O’Donnell, J., Christensen, D. J., Nicholson, C., Iliff, J. J., et al. (2013) · Science · doi:10.1126/science.1241224 · Cited by 5,411
High Interstitial Fluid Pressure - an Obstacle in Cancer Therapy
Heldin, C.-H., Rubin, K., Pietras, K., & Östman, A. (2004) · Nature reviews. Cancer · doi:10.1038/nrc1456 · Cited by 2,222
Tong, R. T., Boucher, Y., Kozin, S. V., Winkler, F., Hicklin, D. J., & Jain, R. K. (2004) · Cancer Research · doi:10.1158/0008-5472.can-04-0074 · Cited by 1,189
Microvascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183
Mechanistic Determinants of Biotherapeutics Absorption Following SC Administration
Richter, W. F., Bhansali, S. G., & Morris, M. E. (2012) · The AAPS Journal · doi:10.1208/s12248-012-9367-0 · Cited by 377
Frost, G. I. (2007) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.4.4.427 · Cited by 323
High dietary sodium chloride consumption may not induce body fluid retention in humans
Heer, M., Baisch, F., Kropp, J., Gerzer, R., & Drummer, C. (2000) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.2000.278.4.f585 · Cited by 285
An ocular glymphatic clearance system removes β-amyloid from the rodent eye
Wang, X., Lou, N., Eberhardt, A., Yang, Y., Kusk, P., Xu, Q., Förstera, B., Peng, S., Shi, M., Ladrón-de-Guevara, A., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw3210 · Cited by 239
Subcutaneous Absorption of Biotherapeutics: Knowns and Unknowns
Richter, W. F., & Jacobsen, B. (2014) · Drug Metabolism and Disposition · doi:10.1124/dmd.114.059238 · Cited by 235
Reed, R. K., & Rubin, K. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq143 · Cited by 209
Body Fluid Dynamics: Back to the Future
Bhave, G., & Neilson, E. G. (2011) · Journal of the American Society of Nephrology · doi:10.1681/asn.2011080865 · Cited by 215
Interstitial Pressure in Pancreatic Ductal Adenocarcinoma Is Dominated by a Gel-Fluid Phase
DuFort, C. C., DelGiorno, K. E., Carlson, M. A., Osgood, R. J., Zhao, C., Huang, Z., Thompson, C. B., Connor, R. J., Thanos, C. D., Scott Brockenbrough, J., et al. (2016) · Biophysical Journal · doi:10.1016/j.bpj.2016.03.040 · Cited by 171
DuFort, C. C., DelGiorno, K. E., & Hingorani, S. R. (2016) · Gastroenterology · doi:10.1053/j.gastro.2016.03.040 · Cited by 144
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119
Effects of estrogen and progesterone administration on extracellular fluid.
Stachenfeld, N. S., & Taylor, H. S. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01032.2003 · Cited by 103
Progesterone increases plasma volume independent of estradiol
Stachenfeld, N. S., & Taylor, H. S. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00031.2005 · Cited by 67
Model Study of the Pressure Build-Up during Subcutaneous Injection
Thomsen, M., Hernandez-Garcia, A., Mathiesen, J., Poulsen, M., Sørensen, D. N., Tarnow, L., & Feidenhans'l, R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104054 · Cited by 65
Moen, I., Tronstad, K. J., Kolmannskog, O., Salvesen, G. S., Reed, R. K., & Stuhr, L. E. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-446 · Cited by 49
Self-citationScallan, J. P., Davis, M. J., & Huxley, V. H. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2013.260042 · Cited by 49
Lymphatic pump-conduit duality: contraction of postnodal lymphatic vessels inhibits passive flow
Quick, C. M., Ngo, B. L., Venugopal, A. M., & Stewart, R. H. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00322.2008 · Cited by 40
Transport and Immune Functions of the Lymphatic System.
Davis, M. J., Zawieja, S. D., & King, P. D. (2025) · Annual Review of Physiology · doi:10.1146/annurev-physiol-022724-104908 · Cited by 42
Rukwied, R., Zeck, S., Schmelz, M., & McGlone, F. (2002) · Journal of the American Academy of Dermatology · doi:10.1067/mjd.2002.120461 · Cited by 35
Hompesch, M., Muchmore, D. B., Morrow, L., Ludington, E., & Vaughn, D. E. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0117 · Cited by 25
A mathematical model of intracranial pressure dynamics for brain hypothermia treatment
Gaohua, L., & Kimura, H. (2006) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2005.06.036 · Cited by 19
Metadata
- Authors
- Aukland, K., & Reed, R. K.
- Venue
- Physiological Reviews
- Publisher
- American Physiological Society
- Published
- 1993-01-01
- Volume
- 73
- Issue
- 1
- Pages
- 1-78
- ISSN
- 0031-9333 (ISSN-L)
- 1522-1210
- OpenAlex
- W2181049752
- Cited by
- 934
- References
- 0
- FWCI
- 8.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.