Cited by 176Circadian rhythm and melatoninSleep and Work-Related FatigueImpact of Light on Environment and Health

Melatonin as a biomarker of circadian dysregulation

Mirick, Dana K., Davis, Scott·2008·Cancer Epidemiology, Biomarkers & Prevention

Abstract

It would be most useful to identify a biomarker of circadian dysregulation that could be used in epidemiologic studies of the effects of circadian disruption in humans. An indicator of circulating melatonin level has been shown to be a good biomarker of circadian dysregulation and has been associated with nightshift work and exposure to light-at-night in both laboratory-based and field studies. Among other circadian markers (such as core body temperature), it remains comparatively robust in the presence of various external influences. It can be reliably measured directly and indirectly through its metabolites in urine, blood, and saliva. Urinary melatonin has been shown to be stable over time, making it useful in epidemiologic studies in which laboratory processing is not immediately available, as well as studies of cancer with long latency periods. Several studies have shown melatonin to be useful in measuring diurnal type, which is of increasing interest as it becomes more apparent that successful adaptation to shift work may be dependent on diurnal preference.

Integrity signals

Registry

Crossref · 10.1158/1055-9965.epi-08-0605

Cites

138 of 138 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Use of urine samples to measure melatonin metabolites is widely reported in epidemiologic studies but is limited by poorer urine sample resolution, which affects accuracy of measurement.

    “In contrast, the use of urine samples to measure melatonin metabolites is widely reported in epidemiologic studies (27) but is limited because of the poorer urine sample resolution which affects the accuracy of measurement (28).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Mirick, D. K., & Davis, S.
Affiliations
  • Fred Hutch Cancer Center (US)
  • University of Washington (US)
Venue
Cancer Epidemiology, Biomarkers & Prevention
Published
2008-12-01
Volume
17
Issue
12
Pages
3306-3313
ISSN
  • 1055-9965 (ISSN-L)
  • 1538-7755
OpenAlex
W2083933443
Cited by
176
References
138
Citations by year
2026: 3 · 2025: 15 · 2024: 6 · 2023: 13 · 2022: 9 · 2021: 6 · 2020: 11 · 2019: 10 · 2018: 11 · 2017: 10 · 2016: 6 · 2015: 9 · 2014: 11 · 2013: 16 · 2012: 15
FWCI
0.90
Type
journal article
Language
en
Open access
closed
Locations
  • Cancer Epidemiology Biomarkers & Prevention (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and Work-Related Fatigue
  • Physical Sciences › Environmental Science › Global and Planetary Change › Impact of Light on Environment and Health
Keywords
melatonin, circadian dysfunction, biomarkers, circadian rhythm disruption, night shift work, light at night, urinary melatonin, diurnal preference, core body temperature, cancer risk
MeSH terms
Body Temperature, Circadian Rhythm, Humans, Light, Melatonin, Pineal Gland, Work Schedule Tolerance, Biomarkers, Chronobiology Disorders

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review