Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar Reconstruction
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background— We analyzed the accuracy of multi-detector row spiral computed tomography (MDCT) using a 16-slice CT scanner with improved spatial and temporal resolution, as well as routine premedication with β-blockers for detection of coronary stenoses. Methods and Results— Seventy-seven patients with suspected coronary disease were studied by MDCT (12×0.75-mm cross-sections, 420 ms rotation, 100 mL contrast agent IV at 5 mL/s). Patients with a heart rate above 60/min received 50 mg atenolol before the scan. In axial MDCT images and multiplanar reconstructions, all coronary arteries and side branches with a diameter of 1.5 mm or more were assessed for the presence of stenoses exceeding 50% diameter reduction. In comparison to invasive coronary angiography, MDCT correctly classified 35 of 41 patients (85%) as having at least 1 coronary stenosis and correctly detected 57 of 78 coronary lesions (73%). After excluding 38 of 308 coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery in 77 patients) classified as unevaluable by MDCT (12%), 57 of 62 lesions were detected, and absence of stenosis was correctly identified in 194 of 208 arteries (sensitivity: 92%; specificity: 93%; accuracy: 93%; positive and negative predictive values: 79% and 97%). Conclusions— MDCT coronary angiography with improved spatial resolution and premedication with oral β-blockade permits detection of coronary artery stenoses with high accuracy and a low rate of unevaluable arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Nieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M. T., & de Feyter, P. J. (2002) · Circulation · doi:10.1161/01.cir.0000037222.58317.3d · Cited by 956
Coronary angiography with multi-slice computed tomography
Nieman, K., Oudkerk, M., Rensing, B. J., van Ooijen, P., Munne, A., van Geuns, R.-J., & de Feyter, P. J. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04058-7 · Cited by 725
Achenbach, S., Giesler, T., Ropers, D., Ulzheimer, S., Derlien, H., Schulte, C., Wenkel, E., Moshage, W., Bautz, W., Daniel, W. G., et al. (2001) · Circulation · doi:10.1161/01.cir.103.21.2535 · Cited by 667
Self-citationJakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Self-citationKopp, A. (2002) · European Heart Journal · doi:10.1016/s0195-668x(02)93264-1 · Cited by 252
Techniques for the Detection of Coronary Atherosclerosis: Multi–detector Row CT Coronary Angiography
Vogl, T. J., Abolmaali, N. D., Diebold, T., Engelmann, K., Ay, M., Dogan, S., Wimmer-Greinecker, G., Moritz, A., & Herzog, C. (2002) · Radiology · doi:10.1148/radiol.2231010515 · Cited by 203
Flohr, T., Bruder, H., Stierstorfer, K., Simon, J., Schaller, S., & Ohnesorge, B. (2002) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2002-32930 · Cited by 164
Self-citationHeuschmid, M., Küttner, A., Flohr, T. G., Wildberger, J. E., Lell, M., Kopp, A. F., Schröder, S., Baum, U., Schaller, S., Hartung, A., et al. (2002) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2002-32227 · Cited by 49
Self-citation
Cited by
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Self-citationBudoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Self-citationQuantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Leipsic, J., Abbara, S., Achenbach, S., Cury, R., Earls, J. P., Mancini, G. J., Nieman, K., Pontone, G., & Raff, G. L. (2014) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2014.07.003 · Cited by 1,072
Self-citationMollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Achenbach, S., Moselewski, F., Ropers, D., Ferencik, M., Hoffmann, U., MacNeill, B., Pohle, K., Baum, U., Anders, K., Jang, I.-K., et al. (2004) · Circulation · doi:10.1161/01.cir.0000111517.69230.0f · Cited by 831
Self-citationSCCT guidelines for the interpretation and reporting of coronary computed tomographic angiography
Raff, G. L., Chair, Abidov, A., Achenbach, S., Berman, D. S., Boxt, L. M., Budoff, M. J., Cheng, V., DeFrance, T., Hellinger, J. C., et al. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.01.001 · Cited by 773
Self-citationAtherothrombosis and High-Risk Plaque
Fuster, V., Moreno, P. R., Fayad, Z. A., Corti, R., & Badimon, J. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.074 · Cited by 738
Leber, A. W., Knez, A., Becker, A., Becker, C., von Ziegler, F., Nikolaou, K., Rist, C., Reiser, M., White, C., Steinbeck, G., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.059 · Cited by 662
Hoffmann, U., Moselewski, F., Nieman, K., Jang, I.-K., Ferencik, M., Rahman, A. M., Cury, R. C., Abbara, S., Joneidi-Jafari, H., Achenbach, S., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.041 · Cited by 566
Self-citationEarls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Noninvasive Coronary Angiography With Multislice Computed Tomography
Hoffmann, M. H. K. (2005) · JAMA · doi:10.1001/jama.293.20.2471 · Cited by 507
Accuracy of In Vivo Coronary Plaque Morphology Assessment
Nasu, K., Tsuchikane, E., Katoh, O., Vince, D. G., Virmani, R., Surmely, J.-F., Murata, A., Takeda, Y., Ito, T., Ehara, M., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.044 · Cited by 496
Bluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
Self-citationVanhoenacker, P. K., Heijenbrok-Kal, M. H., Van Heste, R., Decramer, I., Van Hoe, L. R., Wijns, W., & Hunink, M. G. M. (2007) · Radiology · doi:10.1148/radiol.2442061218 · Cited by 442
Scheffel, H., Alkadhi, H., Plass, A., Vachenauer, R., Desbiolles, L., Gaemperli, O., Schepis, T., Frauenfelder, T., Schertler, T., Husmann, L., et al. (2006) · European Radiology · doi:10.1007/s00330-006-0474-0 · Cited by 420
Hoffmann, U., Moselewski, F., Cury, R. C., Ferencik, M., Jang, I.-K., Diaz, L. J., Abbara, S., Brady, T. J., & Achenbach, S. (2004) · Circulation · doi:10.1161/01.cir.0000145614.07427.9f · Cited by 413
Self-citationAngiogenesis: Where Do We Stand Now?
Simons, M. (2005) · Circulation · doi:10.1161/01.cir.0000159345.00591.8f · Cited by 411
Achenbach, S., Ropers, D., Hoffmann, U., MacNeill, B., Baum, U., Pohle, K., Brady, T. J., Pomerantsev, E., Ludwig, J., Flachskampf, F. A., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.09.053 · Cited by 408
Self-citationMultislice spiral computed tomography coronary angiography in patients with stable angina pectoris
Mollet, N. R., Cademartiri, F., Nieman, K., Saia, F., Lemos, P. A., McFadden, E. P., Pattynama, P. M. T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.032 · Cited by 406
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Self-citationSchoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Self-citationAccuracy of 16-Row Multidetector Computed Tomography for the Assessment of Coronary Artery Stenosis
Garcia, M. J., Lessick, J., Hoffmann, M. H. K., & CATSCAN Study Investigators, F. T. (2006) · JAMA · doi:10.1001/jama.296.4.403 · Cited by 301
Pohle, K., Achenbach, S., MacNeill, B., Ropers, D., Ferencik, M., Moselewski, F., Hoffmann, U., Brady, T. J., Jang, I.-K., & Daniel, W. G. (2007) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2006.01.013 · Cited by 289
Self-citationRispler, S., Keidar, Z., Ghersin, E., Roguin, A., Soil, A., Dragu, R., Litmanovich, D., Frenkel, A., Aronson, D., Engel, A., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.069 · Cited by 286
New Technology for Noninvasive Evaluation of Coronary Artery Disease
Di Carli, M. F., & Hachamovitch, R. (2007) · Circulation · doi:10.1161/circulationaha.106.629808 · Cited by 282
Kuettner, A., Trabold, T., Schroeder, S., Feyer, A., Beck, T., Brueckner, A., Heuschmid, M., Burgstahler, C., Kopp, A. F., & Claussen, C. D. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.079 · Cited by 280
Coles, D. R., Smail, M. A., Negus, I. S., Wilde, P., Oberhoff, M., Karsch, K. R., & Baumbach, A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.078 · Cited by 265
Schuetz, G. M., Zacharopoulou, N. M., Schlattmann, P., & Dewey, M. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-152-3-201002020-00008 · Cited by 265
Noninvasive Coronary Angiography with 16–Detector Row CT: Effect of Heart Rate
Hoffmann, M. H. K., Shi, H., Manzke, R., Schmid, F. T., De Vries, L., Grass, M., Brambs, H.-J., & Aschoff, A. J. (2005) · Radiology · doi:10.1148/radiol.2341031408 · Cited by 264
Accuracy of thin-slice computed tomography in the detection of coronary stenoses
MARTUSCELLI, E. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.024 · Cited by 259
Schuijf, J. D., Bax, J. J., Shaw, L. J., de Roos, A., Lamb, H. J., van der Wall, E. E., & Wijns, W. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.03.022 · Cited by 255
Schuijf, J. D., Pundziute, G., Jukema, J. W., Lamb, H. J., van der Hoeven, B. L., de Roos, A., van der Wall, E. E., & Bax, J. J. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.01.092 · Cited by 232
Noncardiac Findings in Cardiac Imaging With Multidetector Computed Tomography
Onuma, Y., Tanabe, K., Nakazawa, G., Aoki, J., Nakajima, H., Ibukuro, K., & Hara, K. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.04.071 · Cited by 215
Unsuspected Extracolonic Findings at Screening CT Colonography: Clinical and Economic Impact1
Pickhardt, P. J., Hanson, M. E., Vanness, D. J., Lo, J. Y., Kim, D. H., Taylor, A. J., Winter, T. C., & Hinshaw, J. L. (2008) · Radiology · doi:10.1148/radiol.2491072148 · Cited by 197
Desjardins, B., & Kazerooni, E. A. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.4.1820993 · Cited by 192
Schuetz, G. M., Schlattmann, P., & Dewey, M. (2012) · BMJ · doi:10.1136/bmj.e6717 · Cited by 176
Achenbach, S., Ropers, D., Pohle, F.-K., Raaz, D., von Erffa, J., Yilmaz, A., Muschiol, G., & Daniel, W. G. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi326 · Cited by 172
Self-citationda Luz, P. L., Bertini, P. J., & Favarato, D. (2005) · Clinics · doi:10.1590/s1807-59322005000500011 · Cited by 13
“tivities of 89% to 92% and specificities of 93% to 98% have been recently reported, after the exclusion of arteries considered to be of subdiagnostic image quality.(81,82)”
Metadata
- Authors
- Ropers, D., Baum, U., Pohle, K., Anders, K., Ulzheimer, S., Ohnesorge, B., Schlundt, C., Bautz, W., Daniel, W. G., & Achenbach, S.
- Venue
- Circulation
- Published
- 2003-02-11
- Volume
- 107
- Issue
- 5
- Pages
- 664-666
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1971959511
- Cited by
- 930
- References
- 9
- FWCI
- 122.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.