Pulmonary Vein Stenosis After Radiofrequency Ablation of Atrial Fibrillation: Functional Characterization, Evolution, and Influence of the Ablation Strategy
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Background— Pulmonary vein (PV) stenosis is a complication of ablation for atrial fibrillation. The impact of different ablation strategies on the incidence of PV stenosis and its functional characterization has not been described. Methods and Results— PV isolation was performed in 608 patients. An electroanatomic approach was used in 71 and circular mapping in 537 (distal isolation, 25; ostial isolation based on PV angiography, 102; guided by intracardiac echocardiography, 140; with energy delivery based on visualization of microbubbles, 270). Severe (≥70%) narrowing was detected in 21 patients (3.4%), and moderate (50% to 69%) and mild (<50%) narrowing occurred in 27 (4.4%) and 47 (7.7%), respectively. Severe stenosis occurred in 15.5%, 20%, 2.9%, 1.4%, and 0%, respectively. Development of symptoms was correlated with involvement of >1 PV with severe narrowing ( P =0.01), whereas all patients with mild and moderate narrowing were asymptomatic. In the latter group, lung perfusion (V/Q) scans were normal in all but 4 patients. All patients with severe stenosis had abnormal perfusion scans. Conclusions— V/Q scans are useful to assess the functional significance of PV stenosis. Mild and moderate degrees of PV narrowing are not associated with development of symptoms and seem to have no or minimal detrimental effect on pulmonary flow. The incidence of severe PV stenosis seems to be declining with better imaging techniques to ensure ostial isolation and to guide power titration. Mild narrowing 3 months after ablation does not preclude future development of severe stenosis and should be assessed with repeat imaging studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chen, S.-A., Hsieh, M.-H., Tai, C.-T., Tsai, C.-F., Prakash, V. S., Yu, W.-C., Hsu, T.-L., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,446
Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., Salvati, A., Dicandia, C., Mazzone, P., Santinelli, V., et al. (2000) · Circulation · doi:10.1161/01.cir.102.21.2619 · Cited by 1,358
Haïssaguerre, M., Jaïs, P., Shah, D. C., Garrigue, S., Takahashi, A., Lavergne, T., Hocini, M., Peng, J. T., Roudaut, R., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.101.12.1409 · Cited by 922
Marrouche, N. F., Martin, D. O., Wazni, O., Gillinov, A. M., Klein, A., Bhargava, M., Saad, E., Bash, D., Yamada, H., Jaber, W., et al. (2003) · Circulation · doi:10.1161/01.cir.0000070541.83326.15 · Cited by 512
Self-citationKato, R., Lickfett, L., Meininger, G., Dickfeld, T., Wu, R., Juang, G., Angkeow, P., LaCorte, J., Bluemke, D., Berger, R., et al. (2003) · Circulation · doi:10.1161/01.cir.0000061951.81767.4e · Cited by 492
Pulmonary Vein Stenosis After Catheter Ablation of Atrial Fibrillation
Robbins, I. M., Colvin, E. V., Doyle, T. P., Kemp, W. E., Loyd, J. E., McMahon, W. S., & Kay, G. N. (1998) · Circulation · doi:10.1161/01.cir.98.17.1769 · Cited by 443
Circular mapping and ablation of thepulmonary vein for treatment of atrial fibrillation
Marrouche, N. F., Dresing, T., Cole, C., Bash, D., Saad, E., Balaban, K., Pavia, S. V., Schweikert, R., Saliba, W., Abdul-Karim, A., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01972-1 · Cited by 399
Self-citationSaad, E. B., Marrouche, N. F., Saad, C. P., Ha, E., Bash, D., White, R. D., Rhodes, J., Prieto, L., Martin, D. O., Saliba, W. I., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-8-200304150-00010 · Cited by 269
Self-citationDill, T., Neumann, T., Ekinci, O., Breidenbach, C., John, A., Erdogan, A., Bachmann, G., Hamm, C. W., & Pitschner, H.-F. (2003) · Circulation · doi:10.1161/01.cir.0000048146.81336.1d · Cited by 193
Clinical Outcome after Radiofrequency Catheter Ablation of Focal Atrial Fibrillation Triggers
GERSTENFELD, E. P., GUERRA, P., SPARKS, P. B., HATTORI, K., & LESH, M. D. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00900.x · Cited by 191
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citationWazni, O. M., Marrouche, N. F., Martin, D. O., Verma, A., Bhargava, M., Saliba, W., Bash, D., Schweikert, R., Brachmann, J., Gunther, J., et al. (2005) · JAMA · doi:10.1001/jama.293.21.2634 · Cited by 1,121
Feltes, T. F., Bacha, E., Beekman, R. H., Cheatham, J. P., Feinstein, J. A., Gomes, A. S., Hijazi, Z. M., Ing, F. F., de Moor, M., Morrow, W. R., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31821b1f10 · Cited by 853
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847
Stabile, G., Bertaglia, E., Senatore, G., De Simone, A., Zoppo, F., Donnici, G., Turco, P., Pascotto, P., Fazzari, M., & Vitale, D. F. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi583 · Cited by 503
Venice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Self-citationWolf, R. K., Schneeberger, E. W., Osterday, R., Miller, D., Merrill, W., Flege, J. B., & Gillinov, A. M. (2005) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.03.041 · Cited by 392
Donal, E., Lip, G. Y. H., Galderisi, M., Goette, A., Shah, D., Marwan, M., Lederlin, M., Mondillo, S., Edvardsen, T., Sitges, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev354 · Cited by 341
Complications of Catheter Ablation of Atrial Fibrillation: A Systematic Review
Gupta, A., Perera, T., Ganesan, A., Sullivan, T., Lau, D. H., Roberts-Thomson, K. C., Brooks, A. G., & Sanders, P. (2013) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000768 · Cited by 317
Packer, D. L., Keelan, P., Munger, T. M., Breen, J. F., Asirvatham, S., Peterson, L. A., Monahan, K. H., Hauser, M. F., Chandrasekaran, K., Sinak, L. J., et al. (2005) · Circulation · doi:10.1161/01.cir.0000154541.58478.36 · Cited by 288
Pulmonary Vein Stenosis Complicating Ablation for Atrial Fibrillation
Holmes, D. R., Monahan, K. H., & Packer, D. (2009) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2008.12.014 · Cited by 227
Bertaglia, E., Zoppo, F., Tondo, C., Colella, A., Mantovan, R., Senatore, G., Bottoni, N., Carreras, G., Corò, L., Turco, P., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.06.016 · Cited by 215
ARRUDA, M., MLCOCHOVA, H., PRASAD, S. K., KILICASLAN, F., SALIBA, W., PATEL, D., FAHMY, T., MORALES, L. S., SCHWEIKERT, R., MARTIN, D., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00953.x · Cited by 198
Self-citationKISTLER, P. M., EARLEY, M. J., HARRIS, S., ABRAMS, D., ELLIS, S., SPORTON, S. C., & SCHILLING, R. J. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00371.x · Cited by 182
Fender, E. A., Widmer, R. J., Hodge, D. O., Cooper, G. M., Monahan, K. H., Peterson, L. A., Holmes, D. R., & Packer, D. L. (2016) · Circulation · doi:10.1161/circulationaha.116.021949 · Cited by 161
“Number of prior atrial fibrillation ablations 1 (1, 2) 1 (1, 2) 1 (1, 2) 1 (1, 2) 1.”
Metadata
- Authors
- Saad, E. B., Rossillo, A., Saad, C. P., Martin, D. O., Bhargava, M., Erciyes, D., Bash, D., Williams-Andrews, M., Beheiry, S., Marrouche, N. F., Adams, J., Pisanò, E., Fanelli, R., Potenza, D., Raviele, A., Bonso, A., Themistoclakis, S., Brachmann, J., Saliba, W. I., Schweikert, R. A., & Natale, A.
- Venue
- Circulation
- Published
- 2003-12-23
- Volume
- 108
- Issue
- 25
- Pages
- 3102-3107
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2159830299
- Cited by
- 358
- References
- 20
- FWCI
- 17.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.