The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Continuous measurement of left ventricular volume in animals and humans by conductance catheter.
Open accessAbstract
An eight-electrode conductance catheter previously developed by us and used to determine stroke volume in dogs was applied in human beings and dogs to measure absolute left ventricular volume quantitatively. For calibration we developed the formula V(t) = (1/alpha)(L2/sigma b)G(t) - Vc, where V(t) is time-varying left ventricular volume, alpha is a dimensionless constant, L is the electrode separation, sigma b is the conductivity of blood obtained by a sampling cuvette, and G(t) is the measured conductance within the left ventricular cavity. Vc is a correction term caused by the parallel conductance of structures surrounding the cavity and is measured in two ways. The first method, applicable in the anesthetized animal, consists of temporary reduction of volume to zero by suction. The second method uses a transient change in sigma b by injection of a small bolus of hypertonic saline (dogs) or 10 ml of cold glucose (humans) into the pulmonary artery. The validity of the formula was previously established for the isolated postmortem canine heart. The predicted linearity, slope constant alpha, and accuracy of Vc for the left ventricle in vivo were investigated by comparing the conductance volume data with results from independent methods: electromagnetic blood flow measurement for stroke volume and indicator dilution technique for ejection fraction (dogs), thermal dilution for cardiac output (12 patients), and single-plane cineventriculography for V(t) (five patients). In all comparisons, linear regression showed high correlation (from r = .82 [n = 46] to r = .988 [n = 20]) while alpha, with one exception, ranged from 0.75 to 1.07 and the error in Vc ranged from 0.5% to 16.5% (mean 7%). After positioning of the catheter, no arrhythmias were observed. It is concluded that the conductance catheter provides a reliable and simple method to measure left ventricular volume, giving an on-line, time-varying signal that is easily calibrated. Together with left ventricular pressure obtained through the catheter lumen, the instrument may be used for instantaneous display of pressure-volume loops to facilitate assessment of left ventricular pump performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
SUGA, H., & SAGAWA, K. (1974) · Circulation Research · doi:10.1161/01.res.35.1.117 · Cited by 1,330
Development and evaluation of an impedance cardiac output system.
Kubicek, W. G., Karnegis, J. N., PATTERSON, R. P., Witsoe, D. A., & Mattson, R. H. (1966) · PubMed · Cited by 1,143
Grossman, W., Braunwald, E., Mann, T., McLaurin, L. P., & Green, L. H. (1977) · Circulation · doi:10.1161/01.cir.56.5.845 · Cited by 602
Thermodilution cardiac output determination with a single flow-directed catheter
Forrester, J. S., Ganz, W., Diamond, G., McHugh, T., Chonette, D. W., & Swan, H. J. C. (1972) · American Heart Journal · doi:10.1016/0002-8703(72)90429-2 · Cited by 501
Determinants of ventricular function in pressure-overload hypertrophy in man.
Gunther, S., & Grossman, W. (1979) · Circulation · doi:10.1161/01.cir.59.4.679 · Cited by 350
BAAN, J., JONG, T. T. A., KERKHOF, P. L. M., MOENE, R. J., VAN DIJK, A. D., VAN DER VELDE, E. T., & KOOPS, J. (1981) · Cardiovascular Research · doi:10.1093/cvr/15.6.328 · Cited by 300
Self-citationProblems in Measurement of Myocardial Contractility: Analysis of Left Ventricular Function
Mitchell, J. H., & Wildenthal, K. (1972) · Proceedings of the Royal Society of Medicine · doi:10.1177/003591577206500620 · Cited by 29
Cited by
Kass, D. A., Chen, C.-H., Curry, C., Talbot, M., Berger, R., Fetics, B., & Nevo, E. (1999) · Circulation · doi:10.1161/01.cir.99.12.1567 · Cited by 972
Burkhoff, D., Mirsky, I., & Suga, H. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00138.2005 · Cited by 763
Pacher, P., Nagayama, T., Mukhopadhyay, P., Bátkai, S., & Kass, D. A. (2008) · Nature Protocols · doi:10.1038/nprot.2008.138 · Cited by 734
Kasner, M., Westermann, D., Steendijk, P., Gaub, R., Wilkenshoff, U., Weitmann, K., Hoffmann, W., Poller, W., Schultheiss, H.-P., Pauschinger, M., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.661983 · Cited by 565
Role of Left Ventricular Stiffness in Heart Failure With Normal Ejection Fraction
Westermann, D., Kasner, M., Steendijk, P., Spillmann, F., Riad, A., Weitmann, K., Hoffmann, W., Poller, W., Pauschinger, M., Schultheiss, H.-P., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.716886 · Cited by 474
Senzaki, H., Chen, C.-H., & Kass, D. A. (1996) · Circulation · doi:10.1161/01.cir.94.10.2497 · Cited by 383
Asynchronous Electrical Activation Induces Asymmetrical Hypertrophy of the Left Ventricular Wall
van Oosterhout, M. F. M., Prinzen, F. W., Arts, T., Schreuder, J. J., Vanagt, W. Y. R., Cleutjens, J. P. M., & Reneman, R. S. (1998) · Circulation · doi:10.1161/01.cir.98.6.588 · Cited by 363
Gorcsan, J., Strum, D. P., Mandarino, W. A., Gulati, V. K., & Pinsky, M. R. (1997) · Circulation · doi:10.1161/01.cir.95.10.2423 · Cited by 314
Myocardial substrate metabolism influences left ventricular energetics in vivo
Korvald, C., Elvenes, O. P., & Myrmel, T. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.4.h1345 · Cited by 262
In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry
Georgakopoulos, D., Mitzner, W. A., Chen, C.-H., Byrne, B. J., Millar, H. D., Hare, J. M., & Kass, D. A. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.4.h1416 · Cited by 253
A tissue-engineered scale model of the heart ventricle
MacQueen, L. A., Sheehy, S. P., Chantre, C. O., Zimmerman, J. F., Pasqualini, F. S., Liu, X., Goss, J. A., Campbell, P. H., Gonzalez, G. M., Park, S.-J., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0271-5 · Cited by 227
Transgenic Mouse Model of Stunned Myocardium
Murphy, A. M., Kögler, H., Georgakopoulos, D., McDonough, J. L., Kass, D. A., Van Eyk, J. E., & Marbán, E. (2000) · Science · doi:10.1126/science.287.5452.488 · Cited by 228
Hessel, M. H. M., Steendijk, P., den Adel, B., Schutte, C. I., & van der Laarse, A. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00369.2006 · Cited by 163
“decay of RV pressure during isovolumic relaxation (2, 23).”
BackgroundMethodMagnetic resonance imaging of progressive cardiomyopathic changes in the db/db mouse
Yue, P., Arai, T., Terashima, M., Sheikh, A. Y., Cao, F., Charo, D., Hoyt, G., Robbins, R. C., Ashley, E. A., Wu, J., et al. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00856.2006 · Cited by 81
Mohammadi, M. H., Okhovatian, S., Savoji, H., Campbell, S. B., Lai, B. F. L., Wu, J., Pascual‐Gil, S., Bannerman, D., Rafatian, N., Li, R., et al. (2022) · Advanced Biology · doi:10.1002/adbi.202101165 · Cited by 28
Chaanine, A. H., Nonnenmacher, M., Kohlbrenner, E., Jin, D., Kovacic, J. C., Akar, F. G., Hajjar, R. J., & Weber, T. (2014) · Gene Therapy · doi:10.1038/gt.2014.7 · Cited by 25
Use of Pressure-volume Conductance Catheters in Real-time Cardiovascular Experimentation
Wei, A. E., Maslov, M. Y., Pezone, M. J., Edelman, E. R., & Lovich, M. A. (2014) · Heart, Lung and Circulation · doi:10.1016/j.hlc.2014.04.130 · Cited by 17
A human engineered mini-heart platform for mimicking ventricular pump function
Ribeiro, M. C., Cano-Jorge, M., ten Den, S., Snippert, D., Karperien, M., Kamperman, T., Lajoinie, G., Versluis, M., & Passier, R. (2025) · bioRxiv · doi:10.1101/2025.08.25.672056 · Cited by 1
Metadata
- Authors
- Baan, J., van der Velde, E. T., de Bruin, H. G., Smeenk, G. J., Koops, J., van Dijk, A. D., Temmerman, D., Senden, J., & Buis, B.
- Venue
- Circulation
- Published
- 1984-11
- Volume
- 70
- Issue
- 5
- Pages
- 812-823
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2097364562
- Cited by
- 898
- References
- 9
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.