The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Reconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements
Abstract
Background Pulse wave distortions, mainly caused by reflections, and pressure gradients, caused by flow in the resistive vascular tree, may cause differences between finger and brachial artery pressures. These differences may limit the use of finger pressure measurements. We investigated whether brachial artery pressure waves could be reconstructed from finger pressure measurements by correcting for the pressure gradient in addition to correction for pulse wave distortion with a previously described filter. Methods and Results Finger artery pressure (with Finapres), intra-arterial brachial artery pressure (BAP), Riva-Rocci/Korotkoff (RRK), oscillometric, and return-to-flow (RTF) measurements were simultaneously performed in 57 healthy elderly subjects and patients with vascular disease and/or hypertension. A generalized waveform filter was used to correct for pulse wave distortions. Correction equations for the pressure gradient, based on finger pressure, RRK, RTF, or oscillometric measurements, were obtained in 28 randomly selected subjects and tested in 29. Before reconstruction, Finapres underestimated mean and diastolic BAP (finger pressure minus BAP: systolic, −3.2±16.9 mm Hg; mean, −13.0±10.5 mm Hg; diastolic, −8.4±9.0 mm Hg [mean±SD]). After filtering, reconstructed BAP waves were similar to actual BAP in shape but not in pressure level. Optimal correction for the pressure gradient with an equation based on RTF measurements reduced the pressure differences to meet American Association for the Advancement of Medical Instrumentation criteria (reconstructed finger pressure minus BAP: systolic, 3.7±7.0 mm Hg; mean, 0.7±4.6 mm Hg; and diastolic, 1.0±4.9 mm Hg). Conclusions BAP waves can be reconstructed from noninvasive finger pressure registrations when finger pressure waves are corrected for pulse wave distortion and individual pressure gradients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Direct Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 518
White, W. B., Berson, A. S., Robbins, C., Jamieson, M. J., Prisant, L. M., Roccella, E., & Sheps, S. G. (1993) · Hypertension · doi:10.1161/01.hyp.21.4.504 · Cited by 385
Gould, K. L. (1978) · Circulation Research · doi:10.1161/01.res.43.2.242 · Cited by 368
Imholz, B. P. M., Settels, J. J., van der Meiracker, A. H., Wesseling, K. H., & Wieling, W. (1990) · Cardiovascular Research · doi:10.1093/cvr/24.3.214 · Cited by 344
Self-citationIMHOLZ, B. P. M., MONTFRANS, G. A. V., SETTELS, J. J., HOEVEN, G. M. A. V. D., KAREMAKER, J. M., & WIELING, W. (1988) · Cardiovascular Research · doi:10.1093/cvr/22.6.390 · Cited by 275
Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.
Imholz, B. P., Langewouters, G. J., van Montfrans, G. A., Parati, G., van Goudoever, J., Wesseling, K. H., Wieling, W., & Mancia, G. (1993) · Hypertension · doi:10.1161/01.hyp.21.1.65 · Cited by 259
Self-citationFluid dynamics of coronary artery stenosis.
Mates, R. E., Gupta, R. L., Bell, A. C., & Klocke, F. J. (1978) · Circulation Research · doi:10.1161/01.res.42.1.152 · Cited by 196
Continuous finger arterial pressure: Utility in the cardiovascular laboratory
Imholz, B. P. M., Wieling, W., Langewouters, G. J., & van Montfrans, G. A. (1991) · Clinical Autonomic Research · doi:10.1007/bf01826057 · Cited by 181
Self-citationEffects of peripheral vasoconstriction on the measurement of blood pressure in a finger
WESSELING, K. H., SETTELS, J. J., HOEVEN, G. M. A. V. D., NIJBOER, J. A., BUTIJN, M. W. T., & DORLAS, J. C. (1985) · Cardiovascular Research · doi:10.1093/cvr/19.3.139 · Cited by 164
Self-citationComparison of intrabrachial and finger blood pressure in healthy elderly volunteers
Rongen, G. A. P. J. M., Bos, W. J. W., Lenders, J. W. M., vanMontfrans, G., VANLIER, H., vanGoudoever, J. B., Wesseling, K. H., & Thien, T. B. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(94)00000-2 · Cited by 85
Self-citationBos, W. J. W., Imholz, B. P. M., van Goudoever, J., et al. (1992) · American Journal of Hypertension · doi:10.1093/ajh/5.8.529 · Cited by 85
Self-citationEffects of graded vasoconstriction upon the measurement of finger arterial pressure
Imholz, B. P. M., Parati, G., Mancia, G., & Wesseling, K. H. (1992) · Journal of Hypertension · doi:10.1097/00004872-199209000-00010 · Cited by 72
Self-citationThe Measurement of Digital Systolic Blood Pressure by Strain Gauge Technique
Nielsen, P. E., Bell, G., & Lassen, N. A. (1972) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517209080253 · Cited by 68
Idema, R. N., van den Meiracker, A. H., Imholz, B. P. M., Man, A. J., Settels, J. J., van Eck, H. J. R., & Schalekamp, M. A. D. H. (1989) · Journal of Hypertension · doi:10.1097/00004872-198900076-00025 · Cited by 59
Accuracy of auscultatory blood pressure measurement with a long cuff.
van Montfrans, G. A., van der Hoeven, G. M. A., Karemaker, J. M., Wieling, W., & Dunning, A. J. (1987) · BMJ · doi:10.1136/bmj.295.6594.354 · Cited by 51
Effect of Regional and Systemic Changes in Vasomotor Tone on Finger Pressure Amplification
Bos, W. J. W., van den Meiracker, A. H., Wesseling, K. H., et al. (1995) · Hypertension · doi:10.1161/01.hyp.26.2.315 · Cited by 44
Self-citationEpstein, R. H., Huffnagle, S. L., & Bartkowski, R. R. (1991) · The Journal of Clinical Monitoring · doi:10.1007/bf01618116 · Cited by 36
Pseudohypertension and the measurement of blood pressure.
Bos, W. J. W., van Goudoever, J., Wesseling, K. H., Rongen, G. A. P. J. M., Hoedemaker, G., Lenders, J. W. M., & van Montfrans, G. A. (1992) · Hypertension · doi:10.1161/01.hyp.20.1.26 · Cited by 25
Self-citation
Cited by
Becker, H. F., Jerrentrup, A., Ploch, T., Grote, L., Penzel, T., Sullivan, C. E., & Peter, J. H. (2003) · Circulation · doi:10.1161/01.cir.0000042706.47107.7a · Cited by 931
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Principles and Techniques of Blood Pressure Measurement
Ogedegbe, G., & Pickering, T. (2010) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 554
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
Martina, J. R., Westerhof, B. E., van Goudoever, J., de Beaumont, E. M. F. H., Truijen, J., Kim, Y.-S., Immink, R. V., Jöbsis, D. A., Hollmann, M. W., Lahpor, J. R., et al. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824f94ed · Cited by 292
Self-citation
Metadata
- Authors
- Bos, W. J. W., van Goudoever, J., van Montfrans, G. A., van den Meiracker, A. H., & Wesseling, K. H.
- Venue
- Circulation
- Published
- 1996-10-15
- Volume
- 94
- Issue
- 8
- Pages
- 1870-1875
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2104988375
- Cited by
- 365
- References
- 21
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.