CoChat

Retinal prostheses: current challenges and future outlook

Winter, Jessica O., Cogan, Stuart F., Rizzo, Joseph F. · 2007 · Journal of Biomaterials Science, Polymer Edition
Cited by 109

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Blindness from retinal diseases, including age-related macular degeneration (AMD) and retinitis pigmentosa (RP), usually causes a significant decline in quality of life for affected patients. Currently there is no cure for these conditions. However, over the last decade, several groups have been developing retinal prostheses which hopefully will provide some degree of improved visual function to these patients. Several such devices are now in clinical trials. Unfortunately, the possibility of electrode or tissue damage limits excitation schemes to those that may be employed with electrodes that have relatively low charge densities. Further, the excitation thresholds that have been required to achieve vision to date, in general, are relatively high. This may result in part from poor apposition between neurons and the stimulating electrodes and is confounded by the effects of the photoreceptor loss, which initiates other pathology in the surviving retinal tissue. The combination of these and other factors imposes a restriction on the pixel density that can be used for devices that actively deliver electrical stimulation to the retina. The resultant use of devices with relatively low pixel densities presumably will limit the degree of visual resolution that can be obtained with these devices. Further increases in pixel density, and therefore increased visual acuity, will necessitate either improved electrode-tissue biocompatibility or lower stimulation thresholds. To meet this challenge, innovations in materials and devices have been proposed. Here, we review the types of retinal prostheses investigated, the extent of their current biocompatibility and future improvements designed to surmount these limitations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1163/156856207781494403

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 109

Metadata

Authors
Winter, J. O., Cogan, S. F., & Rizzo, J. F.
Venue
Journal of Biomaterials Science, Polymer Edition
Published
2007-01
Volume
18
Issue
8
Pages
1031-1055
ISSN
  • 0920-5063 (ISSN-L)
  • 1568-5624
OpenAlex
W1970877085
Cited by
109
References
24
FWCI
2.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Retinal prostheses: current challenges and future outlook. https://app.cochat.ai/papers/10.1163/156856207781494403
The paper
Winter, J. O., Cogan, S. F., & Rizzo, J. F. (2007). Retinal prostheses: current challenges and future outlook. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856207781494403

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.