CoChat

Photopic and Scotopic Fine Matrix Mapping of Retinal Areas of Increased Fundus Autofluorescence in Patients with Age-Related Maculopathy

Open access
Scholl, Hendrik P. N., Bellmann, Caren, Dandekar, Samantha S., Bird, Alan C., Fitzke, Frederick W. · 2004 · Investigative Opthalmology & Visual Science
Cited by 139

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

PURPOSE: To investigate photopic and scotopic sensitivity of retinal areas that show increased fundus autofluorescence (FAF) in patients with age-related maculopathy (ARM). METHODS: FAF was imaged with a modified confocal scanning laser ophthalmoscope (cSLO). Fine matrix mapping (FMM) was performed with a modified field analyzer. Photopic and scotopic thresholds were obtained at 100 locations on a 9 degrees x 9 degrees matrix with 1 degrees spacing, centered on a macular area of increased FAF. Inclusion criteria included ARM fundus changes, areas of increased FAF, central and stable fixation, and visual acuity of 20/40 or better. RESULTS: FAF images were reviewed in 436 patients with age-related maculopathy (ARM), of whom 38 met the inclusion criteria. FMM was performed in seven eyes of seven patients. Areas of increased FAF in patients with late ARM (choroidal neovascularization or geographic atrophy) showed normal or only mildly abnormal photopic, but severely reduced scotopic, sensitivity. The central area of increased FAF corresponding to a large foveal druse in a patient with ARM showed moderately reduced photopic and severely reduced scotopic sensitivity. In the other patients with ARM with drusen, areas of increased FAF showed normal or near-normal photopic sensitivity, but moderately reduced scotopic sensitivity. CONCLUSIONS: In retinal areas of increased FAF in patients with ARM, scotopic sensitivity loss considerably exceeded photopic sensitivity loss. This finding is in line with histologic data that have demonstrated a preferential loss of rods in ARM, but does not explain the magnitude of sensitivity loss. The study shows that increased FAF in ARM has a functional correlate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.03-0495

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Scholl, H. P. N., Bellmann, C., Dandekar, S. S., Bird, A. C., & Fitzke, F. W.
Venue
Investigative Opthalmology & Visual Science
Published
2004-02-01
Volume
45
Issue
2
Pages
574
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1987515697
Cited by
139
References
10
FWCI
13.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.