CoChat

Virtual Electrodes by Current Steering in Retinal Prostheses

Open access
Dumm, G., Fallon, J. B., Williams, C. E., Shivdasani, M. N. · 2014 · Investigative Ophthalmology & Visual Science

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

PURPOSE: Retinal prostheses are an approved treatment for vision restoration in retinal degenerative diseases; however, present implants have limited resolution and simply increasing the number of electrodes is limited by design issues. In cochlear implants, virtual electrodes can be created by simultaneous stimulation of adjacent physical electrodes (current steering). The present study assessed whether this type of current steering can be adapted for retinal implants. METHODS: Suprachoroidal electrode arrays were implanted in four normally sighted cat eyes. Electrode pairs were driven simultaneously at different current levels and current ratios. Multiunit spiking activity in the visual cortex was recorded. Spike distribution across channels enabled generation of cortical activation maps and calculation of centroid positions. For each current configuration, centroid shifts between two virtual electrodes were compared to shifts obtained from physical electrode stimulation. RESULTS: Using current steering, virtual electrodes with different cortical activation maps could be created. Cortical centroids were found to shift as a function of the current ratio used for virtual electrodes and were similar to the centroid shifts seen when using physical electrodes. In addition, the cortical response to stimulation of a physical electrode could be reproduced by applying current steering to electrodes on either side of the physical electrode. CONCLUSIONS: These results suggest that current steering can alter activation patterns in the visual cortex and could enhance visual perception in retinal implants by eliciting phosphene percepts intermediate between those elicited by physical electrodes. These results inform development of new electrode arrays that can take advantage of current steering.

Overview

Integrity signals

Registry

Crossref · 10.1167/iovs.14-15391

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 66

Metadata

Authors
Dumm, G., Fallon, J. B., Williams, C. E., & Shivdasani, M. N.
Affiliations
Bionics Institute (AU)
Corresponding author
Shivdasani, M. N.
Venue
Investigative Ophthalmology & Visual Science
Published
2014-10-21
Volume
55
Issue
12
Pages
8077-8085
ISSN
0146-0404 (ISSN-L)
OpenAlex
W2312817279
Cited by
63
References
27
Citations by year
2026: 7 · 2025: 3 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 10 · 2020: 6 · 2019: 5 · 2018: 5 · 2017: 7 · 2016: 8 · 2015: 4
FWCI
2.89
Type
journal article
Language
en
Open access
Locations
  • Investigative Ophthalmology & Visual Science (publishedVersion)
  • PubMed (publishedVersion)
  • Minerva Access (University of Melbourne) (submittedVersion)
Funders
  • State Government of Victoria
  • Medical Research Council
  • Australian Research Council
  • National Health and Medical Research Council (1063093)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
retinal prosthesis, current steering, virtual electrodes, visual cortex activation, retinal degeneration, vision restoration, cat eye
MeSH terms
Animals, Cats, Electric Stimulation, Electrodes, Implanted, Evoked Potentials, Visual, Retina, Retinal Degeneration, Visual Cortex, Visual Perception, Models, Animal, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.