Virtual Electrodes by Current Steering in Retinal Prostheses
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
PURPOSE: Retinal prostheses are an approved treatment for vision restoration in retinal degenerative diseases; however, present implants have limited resolution and simply increasing the number of electrodes is limited by design issues. In cochlear implants, virtual electrodes can be created by simultaneous stimulation of adjacent physical electrodes (current steering). The present study assessed whether this type of current steering can be adapted for retinal implants. METHODS: Suprachoroidal electrode arrays were implanted in four normally sighted cat eyes. Electrode pairs were driven simultaneously at different current levels and current ratios. Multiunit spiking activity in the visual cortex was recorded. Spike distribution across channels enabled generation of cortical activation maps and calculation of centroid positions. For each current configuration, centroid shifts between two virtual electrodes were compared to shifts obtained from physical electrode stimulation. RESULTS: Using current steering, virtual electrodes with different cortical activation maps could be created. Cortical centroids were found to shift as a function of the current ratio used for virtual electrodes and were similar to the centroid shifts seen when using physical electrodes. In addition, the cortical response to stimulation of a physical electrode could be reproduced by applying current steering to electrodes on either side of the physical electrode. CONCLUSIONS: These results suggest that current steering can alter activation patterns in the visual cortex and could enhance visual perception in retinal implants by eliciting phosphene percepts intermediate between those elicited by physical electrodes. These results inform development of new electrode arrays that can take advantage of current steering.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, current steering has been applied both in retinal implants (Dumm et al., 2014; Matteucci et al., 2013), cochlear implants (Firszt et al., 2007; Kalkman et al., 2016) and deep brain stimulators (Gross and McDougal, 2013) although it has not yet found clinical applications in the cerebral cortex.”
From Dynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans (2020) · cites this paper as Dumm et al., 2014
Citations
Cites
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Morimoto, T., Ikuno, Y., Nishida, K., Kishima, H., Maruo, T., Konoma, K., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6836 · Cited by 216
Current focusing and steering: Modeling, physiology, and psychophysics
Bonham, B. H., & Litvak, L. M. (2008) · Hearing Research · doi:10.1016/j.heares.2008.03.006 · Cited by 197
Weiland, J. D., & Humayun, M. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2314733 · Cited by 186
Visual prostheses for the blind
Shepherd, R. K., Shivdasani, M. N., Nayagam, D. A. X., Williams, C. E., & Blamey, P. J. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.07.001 · Cited by 178
Self-citationBerenstein, C. K., Mens, L. H. M., Mulder, J. J. S., & Vanpoucke, F. J. (2008) · Ear & Hearing · doi:10.1097/aud.0b013e3181645336 · Cited by 178
Auditory Cortical Images of Cochlear-Implant Stimuli: Dependence on Electrode Configuration
Bierer, J. A., & Middlebrooks, J. C. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00212.2001 · Cited by 172
Stimulation with a Wireless Intraocular Epiretinal Implant Elicits Visual Percepts in Blind Humans
Klauke, S., Goertz, M., Rein, S., Hoehl, D., Thomas, U., Eckhorn, R., Bremmer, F., & Wachtler, T. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4410 · Cited by 161
Cited by
Dynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans
Beauchamp, M. S., Oswalt, D., Sun, P., Foster, B. L., Magnotti, J. F., Niketeghad, S., Pouratian, N., Bosking, W. H., & Yoshor, D. (2020) · Cell · doi:10.1016/j.cell.2020.04.033 · Cited by 257
“For instance, current steering has been applied both in retinal implants (Dumm et al., 2014; Matteucci et al., 2013), cochlear implants (Firszt et al.”
BackgroundAyton, L. N., Rizzo, J. F., Bailey, I. L., Colenbrander, A., Dagnelie, G., Geruschat, D. R., Hessburg, P. C., McCarthy, C. D., Petoe, M. A., Rubin, G. S., et al. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.8.25 · Cited by 74
Visual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73
“Concomitant delivery of electrical stimuli using different return configurations allows for the elicitation of intermediate percepts (Dumm et al., 2014), reduction of the activation thresholds and better confinement of the electric field (Matteucci et al., 2013, 2016), and also inhibition of neural…”
Teplitzky, B. A., Verbick, L. Z., Xiao, Y., & Johnson, M. D. (2016) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2016.00058 · Cited by 50
“…steering with implantable electrode arrays has existed in the fields of spinal cord stimulation (Holsheimer et al., 1998; Manola et al., 2007), intracochlear stimulation (Firszt et al., 2007; Berenstein et al., 2008), and retinal stimulation (Matteucci et al., 2013; Dumm et al., 2014) for some time.”
BackgroundEpiretinal stimulation with local returns enhances selectivity at cellular resolution
Fan, V. H., Grosberg, L. E., Madugula, S. S., Hottowy, P., Dabrowski, W., Sher, A., Litke, A. M., & Chichilnisky, E. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaeef1 · Cited by 43
The Effect of Electric Cross-Talk in Retinal Neurostimulation
Matteucci, P. B., Barriga-Rivera, A., Eiber, C. D., Lovell, N. H., Morley, J. W., & Suaning, G. J. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18400 · Cited by 39
“Otherwise, a variation in the cortical activation maps is expected as a consequence of neural interference.(8) In a previous study, the QMP stimulation paradigm was presented whereby return current was shared between a distant monopolar electrode and a surrounding hexapolar guard.”
BackgroundInfluentialHigh-amplitude electrical stimulation can reduce elicited neuronal activity in visual prosthesis
Barriga-Rivera, A., Guo, T., Yang, C.-Y., Abed, A. A., Dokos, S., Lovell, N. H., Morley, J. W., & Suaning, G. J. (2017) · Scientific Reports · doi:10.1038/srep42682 · Cited by 40
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 44
“Electrode size, number, configuration (e.g., multipolar), and current steering methods can shape the electric field to optimally and precisely activate neurons (Dumm et al. 2014; Mishra et al. 2023; Tebcherani et al. 2024).”
Self-citationProgress in artificial vision through suprachoroidal retinal implants
Bareket, L., Barriga‐Rivera, A., Zapf, M. P., Lovell, N. H., & Suaning, G. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6cbb · Cited by 45
Xiao, Y., Peña, E., & Johnson, M. D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2457873 · Cited by 41
“Studies in the fields of cochlear and retinal implants have demonstrated that current steering can create “virtual electrodes” by differential distribution of the current between physical electrodes to elicit percepts intermediate to those produced using monopolar configurations [46], [72].”
BackgroundRetinal Prosthetic Approaches to Enhance Visual Perception for Blind Patients
Shim, S., Eom, K., Jeong, J., & Kim, S. J. (2020) · Micromachines · doi:10.3390/mi11050535 · Cited by 41
“evaluated the feasibility of virtual electrodes by current steering in retinal prostheses by varying the ratio of the stimulation current levels between two electrodes and recording the spatial shift of cortical activation patterns evoked by retinal stimulation [118].”
BackgroundOptimization of Electrical Stimulation for a High-Fidelity Artificial Retina
Shah, N. P., Madugula, S., Grosberg, L., Mena, G., Tandon, P., Hottowy, P., Sher, A., Litke, A., Mitra, S., & Chichilnisky, E. J. (2019) · 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner.2019.8716987 · Cited by 32
“For example, the impact of different electrical stimulation patterns such as current steering [17], [19], [20] and local return [21], [22] can be directly compared by evaluating the quality of the final inferred visual image.”
BackgroundRetinal Stimulator ASIC Architecture Based on a Joint Power and Data Optical Link
Lemaire, W., Benhouria, M., Koua, K., Besrour, M., Gauthier, L.-P., Martin-Hardy, G., Rossignol, T., Roy, S., & Fontaine, R. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3045141 · Cited by 32
Creating virtual electrodes with 2D current steering
Spencer, T. C., Fallon, J. B., & Shivdasani, M. N. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab1b8 · Cited by 33
“Our previous work showed no significant difference in the activation spread of responses elicited by physical electrodes and virtual electrodes created by stimulation of electrode pairs [10].”
BackgroundResultInfluentialSelf-citationImplications of Neural Plasticity in Retinal Prosthesis
Caravaca-Rodriguez, D., Gaytan, S. P., Suaning, G. J., & Barriga‐Rivera, A. (2022) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.63.11.11 · Cited by 42
Su, X., Guo, J., Zhou, M., Chen, J., Li, L., Chen, Y., Sui, X., Li, H., & Chai, X. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3055203 · Cited by 30
“The steerable electric fields controlled by current ratios without physical electrode movability were similar to the concept of virtual electrodes, which was firstly applied in cochlear implants [29] and utilized for retinal prostheses currently [22], [30], [31].”
MethodGlobal activity shaping strategies for a retinal implant
Spencer, M. J., Kameneva, T., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf071 · Cited by 28
Biological Considerations of Optical Interfaces for Neuromodulation
Hart, W. L., Kameneva, T., Wise, A. K., & Stoddart, P. R. (2019) · Advanced Optical Materials · doi:10.1002/adom.201900385 · Cited by 26
Microstimulation-evoked neural responses in visual cortex are depth dependent
Allison-Walker, T., Hagan, M. A., Price, N. S. C., & Wong, Y. T. (2021) · Brain stimulation · doi:10.1016/j.brs.2021.04.020 · Cited by 25
Neural Responses to Multielectrode Stimulation of Healthy and Degenerate Retina
Halupka, K. J., Abbott, C. J., Wong, Y. T., Cloherty, S. L., Grayden, D. B., Burkitt, A. N., Sergeev, E. N., Luu, C. D., Brandli, A. A., Allen, P. J., et al. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-21290 · Cited by 25
“Optimal microelectrode array positions were determined by first recording evoked potentials (EPs) from the cortical surface in response to retinal stimulation.(14,17) Neural signals were sampled at 30 kHz (Cerebus Neural Processing System; Blackrock Microsystems) with offline stimulus artifact removal(17,39,41) and ba…”
MethodSelf-citationAplin, F. P., Fletcher, E. L., Luu, C. D., Vessey, K. A., Allen, P. J., Guymer, R. H., Shepherd, R. K., & Shivdasani, M. N. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-19926 · Cited by 25
“In order to measure the spread of cortical activation, cortical selectivity was calculated for each spatial map.17,18 Cortical selectivity for each stimulating electrode was measured as the rate of reduction in normalized spike rate across the cortex as a function of physical distance from the BCE, quantified by takin…”
BackgroundMethodInfluentialSelf-citationPrediction of cortical responses to simultaneous electrical stimulation of the retina
Halupka, K. J., Shivdasani, M. N., Cloherty, S. L., Grayden, D. B., Wong, Y. T., Burkitt, A. N., & Meffin, H. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2560/14/1/016006 · Cited by 21
Self-citationSpike-triggered average electrical stimuli as input filters for bionic vision—a perspective
Rathbun, D. L., Ghorbani, N., Shabani, H., Zrenner, E., & Hosseinzadeh, Z. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae493 · Cited by 21
neuroBi: A Highly Configurable Neurostimulator for a Retinal Prosthesis and Other Applications
Slater, K. D., Sinclair, N. C., Nelson, T. S., Blamey, P. J., & Mcdermott, H. J. (2015) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2015.2455507 · Cited by 20
“which has the potential to improve the spatial resolution of retinal prostheses [44], [45].”
BackgroundLyu, Q., Lu, Z., Li, H., Qiu, S., Guo, J., Sui, X., Sun, P., Li, L., Chai, X., & Lovell, N. H. (2019) · International Journal of Neural Systems · doi:10.1142/s0129065720500069 · Cited by 24
Intracortical current steering shifts the location of evoked neural activity
Meikle, S. J., Hagan, M. A., Price, N. S. C., & Wong, Y. T. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac77bf · Cited by 21
“A potential solution that has been tested in retinal [23, 24], optic nerve [25], cochlear [26, 27], facial muscle [28] and cortical implants [14, 29] is current steering.”
Yan, Y., Lu, Y., Li, M., Ma, Z., Cao, P., Chen, Y., Sun, X., Chai, X., Ren, Q., & Li, L. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-17543 · Cited by 20
“For each a, Dumm et al.(37) analyzed spatial selectivity across all cortical recording electrodes at a current level required to reach 90% of maximum cortical response on the best cortical electrode (cortical electrode with the lowest threshold) and thus measured selectivity at the same point on the electrical dynamic…”
BackgroundSpatially patterned bi-electrode epiretinal stimulation for axon avoidance at cellular resolution
Vilkhu, R. S., Madugula, S. S., Grosberg, L. E., Gogliettino, A. R., Hottowy, P., Dabrowski, W., Sher, A., Litke, A. M., Mitra, S., & Chichilnisky, E. J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3450 · Cited by 18
Italiano, M. L., Guo, T., Lovell, N. H., & Tsai, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac72c2 · Cited by 18
Long‐term anesthetic protocol in rats: feasibility in electrophysiology studies in visual prosthesis
Barriga‐Rivera, A., Tatarinoff, V., Lovell, N. H., Morley, J. W., & Suaning, G. J. (2017) · Veterinary Ophthalmology · doi:10.1111/vop.12507 · Cited by 18
“Acute procedures are however long and require extended periods of surgical anesthesia to maintain the animal and to ensure its well-being over several hours or days.(9,10,12,13) In light of the 3-Rs principle (replacement, reduction, and Table 1.”
BackgroundPrecise Temporal Control of Interferential Neural Stimulation via Phase Modulation
Terasawa, Y., Tashiro, H., Ueno, T., & Ohta, J. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3091689 · Cited by 17
Spectral distribution of local field potential responses to electrical stimulation of the retina
Wong, Y. T., Halupka, K., Kameneva, T., Cloherty, S. L., Grayden, D. B., Burkitt, A. N., Meffin, H., & Shivdasani, M. N. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036003 · Cited by 16
Self-citationSong, X., Guo, T., Shivdasani, M. N., Dokos, S., Lovell, N. H., Li, X., Qiu, S., Li, T., Zheng, S., & Li, L. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc3a9 · Cited by 17
Self-citationNeurophysiological considerations for visual implants
Meikle, S. J., & Wong, Y. T. (2022) · Brain Structure and Function · doi:10.1007/s00429-021-02417-2 · Cited by 15
“This can be done in blind humans by driving the lower area in the visual hierarchy with electrical stimulation to localize an initial point of reference for the second implant as visual sensory responses will not be possible (Chen et al. 2020; Dumm et al. 2014; Spencer et al. 2018).”
BackgroundTemporal properties of inferior colliculus neurons to photonic stimulation in the cochlea
Tan, X., Young, H. K., Matic, A. I., Zirkle, W., Rajguru, S. M., & Richter, C. (2015) · Physiological Reports · doi:10.14814/phy2.12491 · Cited by 12
“2014), current steering (Koch et al. 2007; Anderson 2008; Berenstein et al. 2008; Bonham and Litvak 2008; Frijns et al. 2009; Srinivasan et al. 2010; Donaldson et al. 2011; Wu and Luo 2013; Dumm et al. 2014), or improved cochlear implant electrodes have been employed to enhance the performance of the implant users.”
BackgroundReal-Time Optimization of the Current Steering for Visual Prosthesis
Chen, Z., Wang, B.-Y., & Palanker, D. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441400 · Cited by 10
“Computation of the electric field emanating from multiple electrodes involves Poisson’s equation of volume conduction, which can be solved with the finite element method (FEM) [3][6][7][10][11][12].”
BackgroundMethodMultipolar Field Shaping in a Suprachoroidal Visual Prosthesis
Eiber, C. D., Dokos, S., Lovell, N. H., & Suaning, G. J. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2730880 · Cited by 10
“Current steering via multiple monopolar stimulation electrodes has been shown to be effective for steering the recruitment of retinal ganglion cells (RGCs) via fine electrode arrays in vitro [10]–[12] and in vivo [13].”
BackgroundElectrical Field Shaping Techniques in a Feline Model of Retinal Degeneration
Spencer, T. C., Fallon, J. B., Abbott, C. J., Allen, P. J., Brandli, A. A., Luu, C. D., Epp, S. B., & Shivdasani, M. N. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512473 · Cited by 9
Self-citationA 4+1 architecture for in vivo electrophysiology visual prosthesis
Barriga‐Rivera, A., Eiber, C. D., Matteucci, P. B., Chen, S. C., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2016) · Journal of Accessibility and Design for All · doi:10.17411/jacces.v6i2.108 · Cited by 8
“As visual prostheses continue to develop, further understanding of current steering strategies is required to improve the performance of retinal implants (Dumm et al., 2014; Matteucci et al., 2013).”
BackgroundMethodNeural activity shaping in visual prostheses with deep learning
Castro, D., Grayden, D. B., Hamish Meffin, A., & Spencer, M. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad6186 · Cited by 6
Electrically evoked potentials in an ovine model for the evaluation of visual prosthesis efficacy
Barriga‐Rivera, A., Eiber, C. D., Dodds, C. W. D., Fung, A. T.-C., Tatarinoff, V., Lovell, N. H., & Suaning, G. J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319112 · Cited by 6
Development and Experimental Basis for the Future of Prosthetic Vision
Allen, P. J., & Ayton, L. N. (2020) · Springer eBooks · doi:10.1007/978-981-15-7644-7_33 · Cited by 7
Neural Activity Shaping in Visual Prostheses with Deep Learning
Castro, D., Grayden, D. B., Meffin, H., & Spencer, M. (2023) · doi:10.1101/2023.12.20.572123 · Cited by 4
Spatially precise activation of the mouse cochlea with a multi-channel hybrid cochlear implant
Azees, A. A., Thompson, A. C., Ruther, P., Ajay, E. A., Zhou, J., Robles, U. A. A., Garrett, D. J., Quigley, A. F., Fallon, J. B., & Richardson, R. T. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/add091 · Cited by 4
Self-citationNeural activity shaping utilizing a partitioned target pattern
Spencer, M., Kameneva, T., Grayden, D. B., Burkitt, A. N., & Meffin, H. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abecc4 · Cited by 4
“This is the result of the flow of electrical current in the neural tissue [9, 10] as well as characteristics of the neural structures and connections [6].”
BackgroundMiyoshi, T., Morimoto, T., Sawai, H., & Fujikado, T. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.717429 · Cited by 6
Virtual electrodes generated by focused penta‐polar current stimulation for neuromodulation
Shim, S., Park, J. H., & Kim, S. J. (2020) · Micro & Nano Letters · doi:10.1049/mnl.2019.0348 · Cited by 4
“lear implants and retinal prostheses, respectively [11, 12].”
BackgroundMethodInfluentialRetinal prosthesis that incorporates the organization of the nerve fibre layer
FitzGibbon, T. (2017) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.12899 · Cited by 5
“retinotopy may prove to be more efficacious.(13,14) However, any stimulus regimen must cope with an essentially nontopographic substrate in which the stimulus will preferentially activate the largest fibres in any given population (parasol cells, in particular peripheral parasol cells).”
BackgroundFilling in the Visual Gaps: Shifting Cortical Activity using Current Steering
Meikle, S. J., Hagan, M. A., Price, N. S. C., & Wong, Y. T. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629693 · Cited by 3
“Previous current steering work only assessed either the neural activity response (retinal [15], optic nerve [16]) or the sensory output (cochlear [14, 18], cortical”
BackgroundBipolar intracortical microstimulation expands the repertoire of neuronal activation patterns
Schelles, M., Verhaege, A., Rompaey, N. V., Goyvaerts, L., Wierda, K. D. B., Ceyssens, F., Kraft, M. D., & Bonin, V. (2026) · Journal of Neural Engineering · doi:10.1101/2025.03.21.644593 · Cited by 3
“Most existing examples from current steering or bipolar stimulation take place on a superficial [15,16,19,29–31, 33 ] or a deeper Third, stimulation-induced activity in input layer 4 propagates vertically to layers 2/3 [49].”
Kim, S., Shim, H., & Im, M. (2026) · Advanced Intelligent Systems · doi:10.1002/aisy.202501360 · Cited by 2
Partitioned Temporal Dithering for Efficient Epiretinal Electrical Stimulation
Lotlikar, A., Shah, N. P., Gogliettino, A. R., Vilkhu, R. S., Madugula, S. S., Grosberg, L. E., Hottowy, P., Sher, A., Litke, A. M., Chichilnisky, E. J., et al. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123787 · Cited by 3
Xie, H., Shek, C. H., Wang, Y. H., & Chan, L. L.-H. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856829 · Cited by 2
“Previous studies on visual cortex responses to electrical stimulation have shown various degrees of cortical selectivity following optic nerve stimulation [13], transcorneal stimulation [14], epiretinal stimulation [15], and suprachoroidal stimulation [11, 16-20], in which several studies have shown a high degree of c…”
BackgroundAn arbitrary waveform neurostimulator for preclinical studies: design and verification
Guzmán-Miranda, H., & Barriga‐Rivera, A. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03241-6 · Cited by 2
“This device allows for investigating the benefits of a number of stimulation strategies that include current steering [31, 32], temporal interference [18], and stochastic facilitation [33] among others.”
Motion perception with visual prostheses
Renshaw, K. T., & Pezaris, J. S. (2026) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae46fd · Cited by 1
“Current steering has been used in retinal (Dumm et al 2014, Spencer et al 2018), optic nerve (Yan et al 2016), and cochlear (Firszt et al 2007, Landsberger and Srinivasan 2009) implants, among others.”
A preliminary study on virtual electrode for subretinal prostheses by computational model
Wang, N., Song, X., Li, T., Guo, T., & Liming, L. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857730 · Cited by 1
A novel GCaMP6f-RCS rat model for studying electrical stimulation in the degenerated retina
Leibovitch, T. A., Farah, N., Markus, A., & Mandel, Y. (2024) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2024.1386141 · Cited by 1
Experimental and Model-based Approaches to Directional Thalamic Deep Brain Stimulation
Xiao, J. (2016) · University of Minnesota Digital Conservancy (University of Minnesota)
A Preliminary Exploration on Dynamic Virtual Channel for Epiretinal Stimulation: A Modelling Study
Liu, Z., Song, X., Zheng, S., & Li, L. (2022) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei56279.2022.9979842
“[3] Gerald Dumm, James B Fallon, Chris E Williams, Mohit N Shivdasani, “Virtual electrodes by current steering in retinal prostheses,” Investigative Ophthalmology & Visual Science, vol.”
BackgroundNguyen, E., Barkóczi, B., Horváth, C., Judák, L., Rózsa, B. J., Ceyssens, F., Ulbert, I., Wittner, L., Schelles, M., & Fiáth, R. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.02.09.704741
“…enable controlled shaping of the resulting electric field and promote more selective activation of targeted neuronal populations (Berenstein et al., 2008; Bonham & Litvak, 2008; Dumm et al., 2014; Meikle et al., 2022; Opie et al., 2013; Spencer et al., 2018; Uguz & Shepard, 2022; Zhu et al., 2012).”
InfluentialBilateral retinal implants for improving visual restoration: a simulated bionic vision study
Rodriguez-Miguez, P., Soria, P. R., & Barriga‐Rivera, A. (2026) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-026-03513-3
“Thus, many aspects of the implants have been previously explored in the laboratory using animal or computational models [41–49].”
Digital Systems for Closed-Loop Neuromodulation Research
Ramesh, R. (2023) · TSpace (University of Toronto)
Reynisson, H., Nguyen, M., Kalloniatis, M., Nivison‐Smith, L., & Shivdasani, M. N. (2026) · Ophthalmology Science · doi:10.1016/j.xops.2026.101174
“…the ipsilateral and contralateral hemispheres, as well as a d-prime (d ′ ) cortical selectivity, defined as the rate of reduction in normalized firing across the cortical array as a function of distance from the best cortical channel (one that had the lowest threshold) 18,24 — 26 were determined.”
Self-citationA Dynamic Virtual Channel Approach to Enhance Retinal Prosthetic Precision
Liu, Z., Guo, T., He, Y., Zheng, S., Song, X., Dai, C., Li, J., Chai, X., Chen, Y., & Li, L. (2026) · Biomimetics · doi:10.3390/biomimetics11050307
The journey of an Australian retinal prosthesis
Abbott, C. J., Nayagam, D. A. X., Petoe, M. A., Ayton, L. N., Barnes, N., Williams, R. A., Luu, C. D., Shivdasani, M. N., Shepherd, R. K., & Allen, P. J. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36643-7.00025-1
Self-citationLiu, Z., Liu, J., Pang, J., Guo, X., Wang, L., Song, X., Li, H., Chai, X., Gan, H., Gong, S., et al. (2026) · Cognitive Neurodynamics · doi:10.1007/s11571-026-10573-6
“Virtual channel (VC) technology generates additional stimulation sites between physical electrodes by adjusting current ratios across electrode pairs (Dumm et al. 2014; Spencer et al. 2018).”
Metadata
- Authors
- Dumm, G., Fallon, J. B., Williams, C. E., & Shivdasani, M. N.
- Affiliations
- Bionics Institute (AU)
- Corresponding author
- Shivdasani, M. N.
- Venue
- Investigative Ophthalmology & Visual Science
- Published
- 2014-10-21
- Volume
- 55
- Issue
- 12
- Pages
- 8077-8085
- ISSN
- 0146-0404 (ISSN-L)
- OpenAlex
- W2312817279
- Cited by
- 63
- References
- 27
- Citations by year
- 2026: 7 · 2025: 3 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 10 · 2020: 6 · 2019: 5 · 2018: 5 · 2017: 7 · 2016: 8 · 2015: 4
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- Investigative Ophthalmology & Visual Science (publishedVersion)
- PubMed (publishedVersion)
- Minerva Access (University of Melbourne) (submittedVersion)
- Funders
- State Government of Victoria
- Medical Research Council
- Australian Research Council
- National Health and Medical Research Council (1063093)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- retinal prosthesis, current steering, virtual electrodes, visual cortex activation, retinal degeneration, vision restoration, cat eye
- MeSH terms
- Animals, Cats, Electric Stimulation, Electrodes, Implanted, Evoked Potentials, Visual, Retina, Retinal Degeneration, Visual Cortex, Visual Perception, Models, Animal, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.