CoChat

Clinical Tests of Ultra-Low Vision Used to Evaluate Rudimentary Visual Perceptions Enabled by the BrainPort Vision Device

Open access
Nau, Amy, Bach, Michael, Fisher, Christopher · 2013 · Translational Vision Science & Technology
Cited by 53

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

PURPOSE: We evaluated whether existing ultra-low vision tests are suitable for measuring outcomes using sensory substitution. The BrainPort is a vision assist device coupling a live video feed with an electrotactile tongue display, allowing a user to gain information about their surroundings. METHODS: = 3 females, average age 43) with healthy ocular status. All subjects performed 11 computer-based psychophysical tests from three programs: Basic Assessment of Light Motion, Basic Assessment of Grating Acuity, and the Freiburg Vision Test as well as a modified Tangent Screen. Assessments were performed at baseline and again using the BrainPort after 15 hours of training. RESULTS: Most tests could be used with the BrainPort. Mean success scores increased for all of our tests except contrast sensitivity. Increases were statistically significant for tests of light perception (8.27 ± 3.95 SE), time resolution (61.4% ± 3.14 SE), light localization (44.57% ± 3.58 SE), grating orientation (70.27% ± 4.64 SE), and white Tumbling E on a black background (2.49 logMAR ± 0.39 SE). Motion tests were limited by BrainPort resolution. CONCLUSIONS: Tactile-based sensory substitution devices are amenable to psychophysical assessments of vision, even though traditional visual pathways are circumvented. TRANSLATIONAL RELEVANCE: This study is one of many that will need to be undertaken to achieve a common outcomes infrastructure for the field of artificial vision.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/tvst.2.3.1

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 18

  1. Resnikoff S, Pascolini D, Etya'ale D, et al. Global data on visual impairment in the year 2002.Bull World Health Organ. 2004;82:844–851.
  2. Humayun MSDJ, Ahuja AK, Caspi A, et al. Preliminary 6 month results from the Argus II epiretinal prosthesis feasibility study.Conf Proc IEEE Eng Med Biol Soc. 2009;2009:4566–4568.
  3. 10.1142/S0219635205000914 · DOI · Paper page
  4. 10.1007/s00221-008-1553-z · DOI · Paper page
  5. 10.1196/annals.1305.006 · DOI · Paper page
  6. 10.1016/j.neubiorev.2007.05.010 · DOI
  7. 10.1097/WNR.0b013e32832104dc · DOI · Paper page
  8. Ptito M, Matteau I, Zhi Wang A, Paulson OB, Siebner HR, Kupers R. Crossmodal recruitment of the ventral visual stream in congenital blindness.Neural Plast. 2012;2012:304045. · DOI · Paper page
  9. 10.1016/S0079-6123(09)17522-2 · DOI · Paper page
  10. 10.1016/j.ajo.2007.01.027 · DOI · Paper page
  11. 10.1097/OPX.0b013e3181b180a6 · DOI
  12. 10.1088/1741-2560/6/3/035003 · doi:10.1088/1741-2560/6/3/035003
  13. 10.1097/00006324-199601000-00008 · doi:10.1097/00006324-199601000-00008 · Paper page
  14. 10.1167/iovs.09-3512 · DOI · Paper page
  15. 10.1007/s00417-006-0474-4 · DOI · Paper page
  16. 10.1097/OPX.0b013e318264e85a · DOI
  17. 10.1097/OPX.0b013e3182271638 · DOI · Paper page
  18. 10.1167/iovs.05-0981 · DOI · Paper page

Cited by

See all 53

Metadata

Authors
Nau, A., Bach, M., & Fisher, C.
Venue
Translational Vision Science & Technology
Published
2013-06
Volume
2
Issue
3
Pages
1
ISSN
2164-2591 (ISSN-L)
OpenAlex
W1965099908
Cited by
53
References
12
FWCI
3.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.