Previous observations in normal subjects have suggested that when 5-g glucose pulses (P) were given in the following sequence: before (P1) and 45 min after beginning a 300 mg/min glucose infusion (P2); during the 20th hr (P3) and 1 hr after the infusion was stopped (P4); the insulin responses were consistent with a simple two-pool model. One pool is a readily available small storage pool which is refilled by a second, larger, more slowly responding pool that controls basal and steady-state insulin output. The identical protocol was employed to evaluate the insulin responses in 13 nonobese diabetic subjects. DIABETICS HAD BASAL INSULIN LEVELS INDISTINGUISHABLE FROM NORMALS (DIABETICS: 10.7+/-4; normals: 10.7+/-5, mean +/-SD, muU/ml), but had significantly elevated basal glucose levels (diabetics: 161+/-27; normals: 88+/-7, mg/100 ml, P < 0.05). The mean early insulin response (3-5 min Delta IRI) after a 5 g glucose pulse (P1) was significantly diminished in diabetics (diabetics 6.4+/-9; normals: 32.5+/-14, muU/ml, P < 0.01) consistent with a defective storage pool output. The glucose disappearance rate, K(G), decreased in parallel with the early insulin response and the slope of the regression line between these two variables was virtually identical with that calculated from 16 normal subjects. Similar to normal subjects, during the short glucose infusion, the acute insulin response to P2 was diminished in diabetics (P < 0.02). In normal subjects after 20 hr of infusion, the rapid insulin responses to P3 are restored to the preinfusion P1 values, and 1 hr after the infusion was stopped, the responses to P4 are increased twofold (P < 0.001). Diabetics, however, demonstrated decreased early responses to P3 (P < 0.001) and no increased response to P4. In contrast to the diminished acute insulin responses to glucose pulses, diabetics have steady-state insulin levels after 20 hr of glucose infusion similar to those of normal subjects (diabetics: 25.7+/-13; normals: 32.5+/-14, muU/ml). Thus both basal and steady-state insulin levels of diabetics were comparable with those of normal subjects, which suggest that although the rapid insulin response from the storage pool output is defective in diabetics, the more slowly responding pool is intact.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci106963

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Lerner, R. L., & Porte, D.
Venue
Journal of Clinical Investigation
Published
1972-07-01
Volume
51
Issue
7
Pages
1624-1631
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2118454999
Cited by
77
References
8
FWCI
3.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.