Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cotlove, E., Harris, E. K., & Williams, G. Z. (1970) · Clinical Chemistry · doi:10.1093/clinchem/16.12.1028 · Cited by 282
Statistical principles underlying analytic goal-setting in clinical chemistry.
Harris, E. K. (1979) · PubMed · Cited by 178
Gowans, E. M. S., Petersen, P. H., Blaabjerg, O., & Hørder, M. (1988) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365518809088757 · Cited by 162
Self-citationThe application of theoretical goals based on biological variation data in proficiency testing.
Cg, F. (1988) · PubMed · Cited by 119
Biological variation in clinical chemistry. An update: collated data, 1988-1991.
Fraser, C. G. (1992) · PubMed · Cited by 112
Self-citationDesirable standards for laboratory tests if they are to fulfill medical needs
Fraser, C. G., & Petersen, P. H. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.7.1447 · Cited by 109
Self-citationSetting analytical goals for random analytical error in specific clinical monitoring situations
Fraser, C. G., Hyltoft Peterson, P., & Larsen, M. L. (1990) · Clinical Chemistry · doi:10.1093/clinchem/36.9.1625 · Cited by 104
Self-citationWestgard, J. O. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.7.1226 · Cited by 85
A Comparison of Analytical Goals for Haemoglobin A 1c Assays Derived Using Different Strategies
Larsen, M. L., Fraser, C. G., & Petersen, P. H. (1991) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329102800313 · Cited by 68
Self-citationAllowable imprecision for laboratory tests based on clinical and analytical test outcome criteria
Westgard, J. O., Seehafer, J. J., & Barry, P. L. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.10.1909 · Cited by 65
Cited by
Myers, G. L. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.0525144 · Cited by 1,232
Schleicher, R. L., Carroll, M. D., Ford, E. S., & Lacher, D. A. (2009) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2008.27016 · Cited by 504
“This amount of bias is considered clinically acceptable, considering other sources of error in measuring serum vitamin C such as analytic error (CVA = 5–9%), within-individual variation for repeated measurements (CVI = 26%), and variation of the group or population for this analyte (CVG = 31%) (62, 63).”
BackgroundEuropean Urinalysis Guidelines
Kouri, T., Fogazzi, G., Gant, V., Hallander, H., Hofmann, W., & Guder, W. G. (2000) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2000.12056993 · Cited by 384
Automated Blood Cell Counts: State of the Art
Buttarello, M., & Plebani, M. (2008) · American Journal of Clinical Pathology · doi:10.1309/ek3c7ctdknvpxvtn · Cited by 355
Fraser, C. G. (2012) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.733 · Cited by 286
“05) rise depends on CV A and the relationship is not linear: this has important ramifi cations for setting analytical quality specifi cations for CV A and is the basis for the concept that CV A should be a fraction, at most half or less, of CV I (8) .”
BackgroundSelf-citation(2012) · Europe PMC (PubMed Central) · Cited by 267
ASVCP guidelines: allowable total error guidelines for biochemistry
Harr, K. E., Flatland, B., Nabity, M., & Freeman, K. P. (2013) · Veterinary Clinical Pathology · doi:10.1111/vcp.12101 · Cited by 227
Hansen, Å. M., Garde, A. H., & Persson, R. (2008) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510701819127 · Cited by 198
Analytical performance characteristics should be judged against objective quality specifications
Fraser, C. G., & Petersen, P. H. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.3.321 · Cited by 194
Self-citationCeriotti, F., Fernandez-Calle, P., Klee, G. G., Nordin, G., Sandberg, S., Streichert, T., Vives-Corrons, J.-L., & Panteghini, M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0091 · Cited by 181
Biological variation of seminal parameters in healthy subjects
Alvarez, C. (2003) · Human Reproduction · doi:10.1093/humrep/deg430 · Cited by 176
Uncertainty of measurement in quantitative medical testing: a laboratory implementation guide.
(2004) · PubMed Central · Cited by 90
M. Stahl, L. G. M. J. (2001) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655101300133612 · Cited by 79
Application of biological variation - a review
Ricos, C., Perich, C., Minchinela, J., Alvarez, V., Simon, M., Biosca, C., Domenech, M., Fernandez, P., Jimenez, C.-V., Garcia-Lario, J. V., et al. (2009) · Biochemia Medica · doi:10.11613/bm.2009.023 · Cited by 66
Biological variation of neuroendocrine tumor markers chromogranin A and neuron-specific enolase
Braga, F., Ferraro, S., Mozzi, R., Dolci, A., & Panteghini, M. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.09.005 · Cited by 49
“Finally, optimal, desirable, and minimum analytical goals for imprecision, bias and total error for CgA and NSE determination were obtained from BV components [8].”
MethodPre-analytical and analytical aspects affecting clinical reliability of plasma glucose results
Pasqualetti, S., Braga, F., & Panteghini, M. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.03.009 · Cited by 41
Yun, Y.-M., Botelho, J. C., Chandler, D. W., Katayev, A., Roberts, W. L., Stanczyk, F. Z., Vesper, H. W., Nakamoto, J. M., Garibaldi, L., Clarke, N. J., et al. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.186569 · Cited by 36
Biologic variability of C-reactive protein: Is the available information reliable?
Braga, F., & Panteghini, M. (2012) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.04.010 · Cited by 36
Kurutas, E. B., Gumusalan, Y., Cetinkaya, A., & Dogan, E. (2015) · Biological Procedures Online · doi:10.1186/s12575-015-0015-9 · Cited by 23
“Determining the effect of analytical variation relative to biological variation is a straightforward way to develop desirable performance criteria of an assay [8,9].”
BackgroundAnalytical performance specifications in clinical chemistry: the holy grail?
Oosterhuis, W. P. (2017) · Journal of Laboratory and Precision Medicine · doi:10.21037/jlpm.2017.09.02 · Cited by 16
“Fraser (18) adapted this expression, because some measurands are subject to tight homeostatic control (e.”
BackgroundBioVar: an online biological variation analysis tool.
Korkmaz, S., Zarasız, G., Göksülük, D., Senes, M., Sönmez, C., & Yucel, D. (2020) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2019-0437 · Cited by 12
Mairesse, A., Wauthier, L., Courcelles, L., Luyten, U., Burlacu, M., Maisin, D., Favresse, J., van Dievoet, M., & Gruson, D. (2021) · Clinical Endocrinology · doi:10.1111/cen.14356 · Cited by 11
Metadata
- Authors
- Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 1997-01
- Volume
- 34
- Issue
- 1
- Pages
- 8-12
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2028975285
- Cited by
- 370
- References
- 16
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.